Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 LAccepted-AOC | ₹32.2 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹40.0 L+₹7.8 L (24.2%)Rejected-Finance AIR FORCE ROAD GORAIMARI HALESHWAR TEZPUR SONITPUR ASSAM 784104 | SONITPUR | ASSAM | 784104 | ₹40.0 L+₹7.8 L (24.2%) | L2 | Rejected-Finance NOT L1 |
| 3 | L3₹45.1 L+₹12.9 L (40.1%)Rejected-Finance | ₹45.1 L+₹12.9 L (40.1%) | L3 | Rejected-Finance NOT L1 |
| 4 | L4₹45.4 L+₹13.2 L (41.2%)Rejected-Finance | ₹45.4 L+₹13.2 L (41.2%) | L4 | Rejected-Finance NOT L1 |
| 5 | L5₹45.6 L+₹13.4 L (41.6%)Rejected-Finance VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | ₹45.6 L+₹13.4 L (41.6%) | L5 | Rejected-Finance NOT L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Oct 2024, 6:00 pmClosed
GE (AF) TEZPUR
GE AF TEZPUR TEZPUR PO SALONIBARI DISTRICT SONITPUR ASSAM 784104
REPAIR/REPLACEMENT OF LED LIGHTS AND ELECTRICAL FITTINGS AT AFS TEZPUR UNDER GE (AF) TEZPUR
2024_MES_679270_1
8048/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
TEZPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) TEZPUR
₹80,000
9 Jan 2025
11 Oct 2024
31 Oct 2024
11 Oct 2024
30 Oct 2024
24 Oct 2024
Amount
S & F LED 20 Watt tube light fitting (T8 type) ,single/double side connection type including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt ,LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2200, lumen efficacy of minimum 110 lumens per watt, lamp base of G 13 bi pin, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 4 KV, protection grade IP 20, CRI greater than 80%, beam angle of 30 degree to 120 degree, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.90, aluminium alloy housing with life span of minimum 50000 burning hours with L70 and IP20 including , life span of minimum 50000 working hours Make Wipro/Philips/ CK Birla Group (Orient Electric) as approved by GE complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed
S & F LED mirror/ wall light fittings nominal power 9-10 Watt, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1000, lumen efficacy of minimum 100 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2 KV, protection grade IP 20, CRI greater than 80%, beam angle of 30 degree to 120 degree, THD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.90, aluminium alloy housing with life span of minimum 50000 burning hours with L70 and IP20 including , life span of minimum 50000 working hours Make Wipro/Philips/ CK Birla Group (Orient Electric) as approved by GE complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed
Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 4140, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, beam angle of 30 degree to 120 degree, ITHD below or less than 15%, CW available CCT of 5700K/6500K, power factor of minimum 0.95, CRCA powder coated white after housing, life span of minimum 50000 working hours with L70 and IP20 including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC. Make Wipro/Philips/CK Birla Group (Orient Electric)
Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt surface type of size 600 mm x 600 mm , LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 4140, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, beam angle of 30 degree to 120 degree, ITHD below or less than 15%, CW available CCT of 5700K/6500K, power factor of minimum 0.95, CRCA powder coated white after housing, life span of minimum 50000 working hours with L70 and IP20 including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC.
Supply and fixing LED panel ceiling luminaire 1ft x 4ft, 40/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 4000, lumen efficacy of minimum 110 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, beam angle of 30 degree to 120 degree, ITHD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95, aluminium alloy housing with life span of minimum 50000 working hours with L70 and IP20 including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core including taking down old unserviceable complete all as specified & directed
S & F LED bulkhead light with pressure die-cast housing light fittings nominal power 10/12 watt LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1100, lumen , , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 65, CRI greater than 80%, THD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95 aluminium alloy housing with life span of minimum 50000 working hours with LED life with L70 criteria including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core including taking down old unserviceable complete all as specified & directed..
S & F LED downlight surface mounted round shape nominal power 15 Watt, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1500, lumen efficacy of minimum 100 lumens per watt, LED driver (SMPS based constant current supply) with output short circuit protection, surge voltage protection upto 3 KVs, protection grade IP 20, CRI greater than 70%, beam angle of 30 degree to 120 degree, THD below or less than 15%, CW available CCT of of 4000K/6000K, power factor of minimum 0.95, saluminium alloy housing with life span of minimum 50000 working hours LED life with L70 criteria including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core including taking down old unserviceable complete all as specified & directed..
Supply and fixing Square shape 15 watt 220 volts AC Surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, nominal power 15 Watt, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1500, lumen efficacy of minimum 100 lumens per watt, LED driver (SMPS based constant current supply) with output short circuit protection, surge voltage protection upto 3 KVs, protection grade IP 20, CRI greater than 70%, beam angle of 30 degree to 120 degree, THD below or less than 15%, CW available CCT of 4000K/6000K, power factor of minimum 0.95, saluminium alloy housing with life span of minimum 50000 working hours with LED life with L70 criteria including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core including taking down old unserviceable complete all as specified & directed.
Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, nominal power 12 Watt, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1200, lumen efficacy of minimum 100 lumens per watt, LED driver (SMPS based constant current supply) with output short circuit protection, surge voltage protection upto 3 KVs, protection grade IP 20, CRI greater than 70%, beam angle of 30 degree to 120 degree, THD below or less than 15%, CW available CCT of 4000K/6000K, power factor of minimum 0.95, saluminium alloy housing with life span of minimum 50000 working hours with LED life with L70 criteria including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core including taking down old unserviceable complete all as specified & directed.
Supply and fixing Square shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, nominal power 12 Watt, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1200, lumen efficacy of minimum 100 lumens per watt, LED driver (SMPS based constant current supply) with output short circuit protection, surge voltage protection upto 3 KVs, protection grade IP 20, CRI greater than 70%, beam angle of 30 degree to 120 degree, THD below or less than 15%, CW available CCT of of 4000K/6000K, power factor of minimum 0.95, saluminium alloy housing with life span of minimum 50000 working hours with LED life with L70 criteria including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core including taking down old unserviceable complete all as specified & directed.
Supply and fixing as in repair LED spot light 6 watt 220 volts AC recessed type designed for commercial usage nominal power 6 Watt, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 600, lumen efficacy of minimum 100 lumens per watt, LED driver (SMPS based constant current supply) with output short circuit protection, surge voltage protection upto 3 KVs, protection grade IP 20, CRI greater than 70%, beam angle of 30 degree to 120 degree, THD below or less than 15%, CW available CCT of of 4000K/6000K, power factor of minimum 0.95, saluminium alloy housing with life span of minimum 50000 working hours with LED life with L70 criteria including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core including taking down old unserviceable complete all as specified & directed.
S&F CIMFR certified LED flame proof batten suitable for single T8 tube of 20 Watt , IP 65 protected , tube with single end connection type with LED tube light 20 W, 240 Volt, PF> 0.90 , colour Temp 6500K, System Luminous efficacy> 100Lm/W, Recommended for Gas / Vapour group of IIA & IIB and Zone 1&2, complete including connecting with PVC insulated multi stranded copper flexible cable 0.5 sqmm three core, Make: Crompton FIAMMA II, Cat Part No. EXTN1LT8-16/20 or equivalent in Sudhir / Shyam Switchgears Pvt ltd or equivalent make as catered in PS
S&F CIMFR certified LED flame proof batten suitable for twin T8 tube of 20 Watt , IP 65 protected , tube with single end connection type with LED tube light 20 W, 240 Volt, PF> 0.90 , colour Temp 6500K, System Luminous efficacy> 100Lm/W, Recommended for Gas / Vapour group of IIA & IIB and Zone 1&2, complete including connecting with PVC insulated multi stranded copper flexible cable 0.5 sqmm three core, Make: Crompton FIAMMA II, Cat Part No. EXTN2LT8-16/20 or equivalent in Sudhir / Shyam Switchgears Pvt ltd or equivalent make as catered in PS
Supply and fix Decorative wall light up -down LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1000, lumen efficacy of minimum 100 lumens per watt, LED driver (SMPS based constant current supply) with output short circuit protection, surge voltage protection upto 3 KVs, protection grade IP 20, CRI greater than 70%, beam angle of 30 degree to 120 degree, THD below or less than 15%, CW available CCT of of 4000K/6000K, power factor of minimum 0.95, aluminium alloy housing with , life span of minimum 50000 working hours with LED life with L70 criteria including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core including taking down old unserviceable complete all as specified & directed.
S&F LED tube lamp 18/20 Watt (reterofit type, T8 pattern, single/double side connection) LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen output of minimum 1800, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, beam angle of 30 degree to 120 degree, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours with LED life with L70 criteria complete fitting to be fixed in existing or new batten/ patti including changing the wiring suitable for T8 LED retrofit lamp in existing tube light fitting including taking down old unserviceable complete.
S&F Batten suitable for LED 18/20 Watt tube (T8 type) ,single end connection type including LED retrofit tube lamp 18 W , 240 Volt, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed including taking down old unserviceable complete . . Note : Make of batten and LED tube lamp should be of same make.
S & F LED street lights nominal power 35 Watt, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 4200, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with LED life with L70 criteria and IK 10 including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge including taking down old unserviceable complete . Note : (i) Any T& P required for the work shall be arranged by the contractor.(ii) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the work services. . Make Bajaj/Wipro/Orient electric
Supply and Fix LED post top lantern light fittings 45 watt, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 4500, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with LED life with L70 criteria and IK 10 including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge including taking down old unserviceable complete . the work services. . Make Philips/Wipro/Orient electric
Note for Item No. 1 to 18 :- (i) It is mandatory that contractor shall submit the insurance certificate minimum 10 Lakh sum assured of all staff/employee employed by him for the work services. (ii) At location where light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt. (iv)All LED lights have replacement warranty of 2 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of 2 year replacement warranty certificate. (v) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly. (vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries. (vii) All LED fitting shall be identified by printing or fixing stickers duly mentioned the C.A number and date of completion. (viii) For any change in product or change in catalogue No. etc due to technological upgradation, letter has to be obtained from the lighting company on their letter head signed by an offical of National level. (ix) All T& P required at site for installation of light on Pole / Bldg /Tower or at any location shall be arranged by contractor.(X) If the clamp is not provided by manufacturer,s , it shall be the responsibility of the contractor to provide the same and the cost for the same is deemed to be included in the quoted rate.
S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, including taking down old u/s one complete all as specified and as directed. Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T.
S&F in repair of stepped type electronic fan regulator 100 watt flush type (delux) on the existing hylem laminated sheet etc as required complete all as specified and directed by EIC.
Supply and fix in repair switch socket combination 2 in 1, 3 pin 5 Amp flush type universal complete all as specified and as directed.
Supply and fix in repair switch socket combination 2 in 1, 3 pin 5 and 15 Amp flush type universal complete all as specified and as directed.
Supply and fix as in repair lamp holder, insulated body, angular type with back plate for batten fitting complete all as specified and as directed. Make for lamp holder: Make:Anchor/Legrand/Havells
Supply and Fix metal frame and louvers suitable for exhaust fan,steel body AC single phase,230V of size 300 mm sweep, with and including connected fittings including taking down old unserviceable complete all as specified & directed.
Supply and Fix in repairs,metal frame and louvers suitable for exhaust fan,steel body AC single phase,230V of size 380 mm sweep,with and including connected fittings including taking down old unserviceable complete all as specified & directed.
Supply and Fix in repairs,metal frame and louvers suitable for exhaust fan,steel body AC single phase,230V of size 450 mm sweep,with and including connected fittings including taking down old unserviceable complete all as specified & directed.
General Note: Being mainteaince contract location for fixing of new light fittings and other repairs will be given to contractor on receiving of complaints or as when and on required basis and not in one span. Contractor shall not ask for hand over the complete site at one go and this aspect shall be included in quoated rates.
M/S Kangkans (BID ID -3154217)
M/S SHIVAYA ENGINEERING (BID ID -3153688)
KAILSON (BID ID -3153386)
Singhs Construction (BID ID -3153545)
SRI JAINATH SINGH (BID ID -3153369)
M/S LAKSHMI COOLING CENTRE (BID ID -3152703)
M/S N G CHOWDHURY (BID ID -3153751)
SHRI D. C. BISWAS (BID ID -3153500)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .