| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.3 L+₹69,253 (2.93%)Rejected-AOC MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical EDALAKADU THABORE P O MOOKANNOOR ERNAKULAM DIST KERALA 683 577 | MOOKANNOOR | ERNAKULAM | KERALA | 683577 | - | Rejected-Technical Remarks in WLR is No |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
20 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
REPAIR/REPLACEMENT OF LT DISTRIBUTION SYSTEM AND CONNECTED WORK AT NAD ALWAYE
2023_MES_603554_1
8254/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
ALWAYE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹60,000
Yes
15 Sept 2023
15 Jun 2023
22 Jul 2023
15 Jun 2023
20 Jul 2023
1 Jul 2023
15 Jun 2023 - 30 Jun 2023
Amount
Material & Labour for re-stretching, restraining ACSR Conductor laid over OH LT/HT line on steel/PCC poles after removing the binding from insulators, lowering the ACSR conductor or broken OH Line due to any reason, jointing the broken conductor, re-winding the ACSR with insulators including providing binding wire, jump ring & connecting the existing service cables after re stretching/Re-stringing to OH line & removing unavoidable sag in the lines, Span consisting of 4 ACSR wire and one earth wire conductor of any description complete all as specified and directed. Note: Item will be measured as whole, No single conductor will be paid separately.
Material & Labour for trimming of tree branches, vegetation bushes etc, from below the overhead line with a clearance of 2.5 metre on both sides including removal of cut material to a distance of 50 metre from work site complete all as specified and directed. (Note: Pole to Pole distance approximately 40-50 RM average of each row of LT/HT line shall be measured and paid).
Material and labour for GI Steel wire 4 mm dia for continuous earthing on poles or for guarding cradles hexagonal or rectangular including stringing and connected to earth wire complete all as specified and directed.
Supply and fixing of aluminium conductor steel reinforced (ACSR) of any size/description on LT Poles including stringing, tightening, binding to insulators with aluminium wire and connecting jumpers, connections etc, commissioning and testing old unserviceable complete all as specified and directed.
Supply and fix Shackle type 75mm height and 90 mm dia insulator, porcelain, vitreous, white, brown or green including gavanised mild steel strap 31mm x 3mm, insulator bolts 12mm dia with suitable washers and nut, suitable for working pressure up to and including 1100 volts fixed to LT Poles complete all as specified and directed.
Supply and fix Pin type, porcelain, vitreous, white/brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed.
Material and labour for old burnt jumper connection in binding with HT/LT Lines from position including re-binding the same with new binding wire of size 2 mm aluminium wire complete all as specified and directed.
Supply and fix heat shrinkable jointing kit straight through joint suitable for LT underground cable of size 10/16/25 Sqmm 4 core 1.1 KV outdoor terminations complete all as specified and directed.
Ditto as per item No 8 but for cables of size 50 to 150 Sqmm 3.5 core.
Material and labour for cable route indicator 15 cm dia with CI plate embossing type of cable fix to angle iron of size 40x 40x 6mm and 45 cm long with necessary fixing arrangement in ground complete all as specified and directed.
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth, for foundation, laying of pipes, cables, etc, or for shafts, wells, cesspits, manholes, pier holes, etc, not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out soft/loose soil complete all as specified and directed.
Ditto as per item No 11 but exceeding 1.5 metre but not exceeding 3.0 metre in depth.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed.
Supply and laying fine dry river sand to entire width of trench as cable cushion in trench for cable complete as specified
Supply & lay un reinforced pre cast concrete cable cover class LV type 1 flat size 250mmx150mmx40mm complete all as directed.
Material & Labour for common burnt clay building bricks, sub-class ‘B’ locally available laid flat with width equal to length of brick over LT underground cable in trenches for mechanical protection of size 23 cm x 11.5 cm x 7.5 cm thick complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for erecting of pole, repair of road cuttings etc all as specified and directed by Engineer-in-Charge
Material and Labour for PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate for erecting of pole, repair of road cuttings etc all as specified and directed by Engineer-in-Charge
Material and Labour for (cold bitumen) for filling/repair of road cutting with road patch material ready mix with minimum residual bitumen constant by weight of mix 4.5%, No heating required, No sticking on tyres etc all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade cross-sectional area 10 Sqmm x 4 core including taking out old unserviceable cable complete all as directed.
Ditto all as per Sl Item No 21 above but cross-sectional area 10 Sqmm 2 core.
Ditto all as per Sl Item No 21 above but cross-sectional area 16 Sqmm 4 core.
Ditto all as per Sl Item No 21 above but cross-sectional area 25 Sqmm 4 core.
Ditto all as per Sl Item No 21 above but cross-sectional area 35 Sqmm 3.5 core.
Ditto all as per Sl Item No 21 above but cross-sectional area 50 Sqmm 3.5 core.
Ditto all as per Sl Item No 21 above but cross-sectional area 70 Sqmm 3.5 core.
Ditto all as per Sl Item No 21 above but cross-sectional area 95 Sqmm 3.5 core.
Ditto all as per Sl Item No 21 above but cross-sectional area 120 Sqmm 3.5 core.
Ditto all as per Sl Item No 21 above but cross-sectional area 150 Sqmm 3.5 core.
Ditto all as per Sl Item No 21 above but cross-sectional area 185 Sqmm 3.5 core.
Ditto all as per Sl Item No 21 above but cross-sectional area 240 Sqmm 3.5 core.
Supply,laying,jointing and testing Tubes’ light grade Galvanised steel tubing of size 50mm bore, to be fixed on walls or laid under roads for passing cables complete as specified and as directed
Ditto all as per Sl item 33 above but of size 40mm bore.
Ditto all as per Sl item 33 above but of size 80mm bore.
Supply and erection of Pre-stressed concrete pole 9.0 metres long, having size of 102x172mm at top and 102x279mm at bottom, class 10, confirming to IS 785 (1964), painting with identification Nos including dismantling old one complete all as specified and as directed
Supply and fix steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP -27, 9.0 metre long including painting of poles with two coats of aluminium enameled paint over one coat a coat of red oxide primer (two coat of black bituminous paint on embedded portion of pole) including dismantling old one complete all as specified and as directed by the Engineer-in-charge. (Note:-Excavation, earth work and PCC shall be measured and paid for separately)
Supply and laying synthetic Rubber insulated mats of sizes 2m x 1m, 2 mm thick for voltage up to 3.3 KV for electrical purpose as per IS 15652-2006,(superseding IS 5424) suitable for electrical shock safety complete all as specified and as directed.
Material & Labour for preparation of old painted surface of LT steel tubular electric pole 9 metre (Top to bottom from ground level) by removing all dirt, dust, etc, painting complete surfaces with one coat of aluminium paint of approved colour including connected accessories such as angle Iron channel of distribution lines, (for three phases and street light phases of any description) with and including writing of identification Nos, 30cm strips of alternative layers up to 1.5 metre from ground level with synthetic enamel paint of black and yellow colour etc complete all as directed by Engineer-in-Charge.
Material & Labour for preparation of old painted surface of LT concrete pole 9 metre (Top to bottom from ground level) by removing all dirt, dust, etc, painting complete surfaces with two coats of Cement based white paint with and including writing of identification Nos, 30cm strips of alternative layers up to 1.5 metre from ground level with synthetic enamel paint of black and yellow colour etc complete all as directed by Engineer-in-Charge.
Material & Labour for installation of sign/display board flat boards type outdoor (size not less than 1.2 metre x 0.6 metre) complete mounted on 20mm size MS square tubing 3 mm thick Aluminium composite material (ACM) made by sandwiching a polythene core between the aluminium sheets including flat iron clamps & angle iron support for grouting /fixing on walls complete including computer printing/inject printing of words/diagram/emblems etc all as directed by Engineer-in-Charge . Note: - The matter in each case depending on the installation will be as given and finalised by the Engineer-in-charge. The rate quoted is deemed to include the same.
Material & Labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for LT, 20x15cm size including dismantling old one complete all as specified and as directed.
Comprehensive maintenance to APFC Panel indoor/outdoor including replacement of burnt out bakelite fuse of suitable size or capacitors of various sizes 5/10/20 KVAR and MCBs of any sizes as specified and directed. Note: - All accessories required to be replaced will be measured and paid separately as supply only.
Supply only power capacitor (MPP) in existing capacitor bank of capacity 5 KVAR as specified
Supply only power capacitor (MPP) in existing capacitor bank of capacity 10 KVAR as specified
Supply, install, testing and commissioning of factory made outdoor type floor mounted LT cubical panel board 415 volts, 3 phase 4 wire, 50 Hz, AC supply, dust and vermin proof IP-54 Protection CPRI Approved having suitable size made out of 3.15 mm CRCA steel sheet powder coated as per IEC 61439 with aluminium bus bar of 300 Amps for phases and 200 Amps for Neutral duly laminated with colour coding sleeves, Mounted on MS angle iron frame of size 40x40x4mm grouted in PCC type B2 above ground level including dismantling old existing panel board. The Panel board shall comprise with the following controls. :- (Notes: - MCCB, Meters, Indicating lamps etc shall be included in the quoted rates) (A) INCOMING:- (a) MCCB 100 Amps, 4 pole, 415 Volts, 25 KA breaking capacity with adjustable thermal magnetic release setting - 1 No (b) Digital type volt meter (0 to 500 Volts) 96 x 96 mm - 01 No (c) Digital type Ammeter (0 to 200 Amps) 96 x 96 mm - 01 No (d) Indicator lamp (set of 3) -01set (B) OUTGOING:- (a) MCCB 40 Amps, 4 poles, 415 Volts, 25KA breaking capacity with adjustable thermal magnetic release setting -3 Nos (b) MCB SP, 32 Amps, 220 Volts, 10KA breaking capacity - 02 Nos.
Supply, install, testing and commissioning of factory made outdoor type floor mounted LT cubical panel board 415 volts, 3 phase 4 wire, 50 Hz, AC supply, dust and vermin proof IP-54 Protection CPRI Approved having suitable size made out of 3.15 mm CRCA steel sheet powder coated as per IEC 61439 with aluminium bus bar of 300 Amps for phases and 200 Amps for Neutral duly laminated with colour coding sleeves, Mounted on MS angle iron frame of size 40x40x4mm grouted in PCC type B2 above ground level including dismantling old existing panel board. The Panel board shall comprise with the following controls. :- (Notes: - MCCB, Meters, Indicating lamps etc shall be included in the quoted rates) (A) INCOMING:- (a) MCCB 63 Amps, 4 pole, 415 Volts, 25 KA breaking capacity with adjustable thermal magnetic release setting - 1 No (b) Digital type volt meter (0 to 500 Volts) 96 x 96 mm - 01 No (c) Digital type Ammeter (0 to 200 Amps) 96 x 96 mm - 01 No (d) Indicator lamp (set of 3) -01set (B) OUTGOING:- (a) MCCB 40 Amps, 4 poles, 415 Volts, 25KA breaking capacity with adjustable thermal magnetic release setting -2 Nos (b) MCB SPN, 32 Amps, 220 Volts, 10KA breaking capacity - 02 Nos.
Supply & Fix in repair On load change over switch 400 Amps, 4 pole, 415 Volts, 50 Hz including dismantling old one complete all as specified and as directed.
Ditto all as per Sl item 48 above but of size 100 Amps.
Supply & Fix in repair MCCB 415Volt, 50 Hz, 400 Amps, 4 pole of breaking capacity 36KA with adjustable thermal magnetic release setting including dismantling old one complete all as specified and as directed.
Supply & Fix in repair MCCB 415Volt, 50 Hz, 250 Amps 3 pole of breaking capacity 35 KA with adjustable thermal magnetic release setting including dismantling old one complete all as specified and as directed.
Supply & Fix in repair MCCB 415Volt, 50 Hz, 250 Amps 4 pole of breaking capacity 36 KA with adjustable thermal magnetic release setting including dismantling old one complete all as specified and as directed.
Supply & Fix in repair MCCB 415Volt, 50 Hz, 40/63 Amps, 3 pole, breaking capacity 25 KA with adjustable thermal magnetic release setting including dismantling old one complete all as specified and as directed.
Supply & Fix in repair MCCB 415Volt, 50 Hz, 200 Amps 4 pole of breaking capacity 35 KA with adjustable thermal magnetic release setting including dismantling old one complete all as specified and as directed.
Supply & Fix in repair MCCB 415Volt, 50 Hz, 63 Amps, 4 pole breaking capacity 25 KA with adjustable thermal magnetic release setting including dismantling old one complete all as specified and as directed.
Supply & Fix in repair MCCB 415Volt, 50 Hz, 160 Amps 4 pole of breaking capacity 25 KA with adjustable thermal magnetic release setting including dismantling old one complete all as specified and as directed.
Supply & Fix in repair MCCB 415Volt, 50 Hz,100 Amps 4 pole of breaking capacity 25 KA with adjustable thermal magnetic release setting including dismantling old one complete all as specified and as directed.
Material & Labour for Earthing complete with GI Steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth wire of size 4 mm, dia by means of bolts, nuts, check soldered and riveted to earth plate, Earth wire will be protected by using 40mm dia bore GI pipe light grade, The earthing includes PCC Pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 metres etc complete all as shown in electrical plate No. 3 of SSR Part-I 2009,connected to earthing test point all as specified or indicated including testing on completion.
Ditto as per item No 58 but using galvanised Earth plate of 600 x 600 x 6mm with iron strip 25x4mm as earthing lead.
Material & Labour for preparation of old painted surface of LT Panel/Distribution box installed at E/M Installations under AGE B/R Alwaye area of any size by removing all dirt, dust etc, and painting complete surface including connected accessories such as angle Iron channel etc of any description with one coat of synthetic enamel paint of approved colour including writing of identification complete all as directed by Engineer-in-Charge.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
Kuriako Mathai and company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .