Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC | ₹22.1 L Quoted ₹22.2 L | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER |
| 2 | L2₹22.2 LRejected-AOC | ₹22.2 L | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 3 | L3₹23.8 LRejected-AOC 1 259 CHUKKUWALA DEHRADUN UK | DEHRADUN | DEHRADUN | UTTARAKHAND | ₹23.8 L | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 4 | L4₹24.7 LRejected-AOC H NO 02 BALLUPUR ROAD DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹24.7 L | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 5 | L5₹26.1 LRejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹26.1 L | L5 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| Sl No | Description | Qty | Unit | KISHORE ENTERPRISES L1 | M/S VIJAY TRADERS L4 | M/S Anil kumar L5 | Sharda Enterprises L3 | M/s Gupta Associates L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation n.exc (not exceeding ) 30 cm deep and averegeing 15 cm deep getting out in any type of soil l etc complete all as specified and directed. | 19.2 | Sqm | 20 ₹384 | 45 ₹864 | 55 ₹1,056 | 20 ₹384 | 40 ₹768 |
| 2.00 | Excavating in trenches, in any type soil not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out complete all as specified and directed. | 63 | Cum | 150 ₹9,450 | 350 ₹22,050 | 250 ₹15,750 | 490 ₹30,870 | 270 ₹17,010 |
| 3.00 | Excavating over areas, n exc 1.5 m deep and getting out in any type of soil complete as specified and directed. | 28.8 | Cum | 150 ₹4,320 | 240 ₹6,912 | 280 ₹8,064 | 500 ₹14,400 | 200 ₹5,760 |
| 4.00 | Excavating over areas, exc 1.5 m deep and and not exc 3.00 m deep and getting out in any type of soil complete as specified and directed. | 28.8 | Cum | 500 ₹14,400 | 275 ₹7,920 | 300 ₹8,640 | 500 ₹14,400 | 250 ₹7,200 |
| 5.00 | Excavating over areas, exc 3.00 m deep and and not exc4.50 m deep and getting out in any type of soil complete as specified and directed. | 14.4 | Cum | 300 ₹4,320 | 350 ₹5,040 | 320 ₹4,608 | 600 ₹8,640 | 310 ₹4,464 |
| 6.00 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distanc n exc 50 m and making good surface inany type of soil complete all as specified and directed. | 4 | Each | 200 ₹800 | 200 ₹800 | 150 ₹600 | 300 ₹1,200 | 200 ₹800 |
| 7.00 | Returning filling in, including spreading, levelling, watering and well ramming in layers n. exc. 25 cm in soft/loose soil complete all as specified and directed. | 60.3 | Cum | 100 ₹6,030 | 60 ₹3,618 | 98 ₹5,909.40 | 100 ₹6,030 | 100 ₹6,030 |
| 8.00 | Removing excavated material soil exc 250m but not exceeding 500m & depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. | 95 | Cum | 300 ₹28,500 | 100 ₹9,500 | 150 ₹14,250 | 100 ₹9,500 | 330 ₹31,350 |
| 9.00 | M&L for loose filling with aggregates of broken bricks, half brunt of gauge 40 to 80 mm as in Rain water harvesting pits, soakage pits, soakage wells etc complete all as specified and directed. | 14.5 | Cum | 800 ₹11,600 | 2,200 ₹31,900 | 2,800 ₹40,600 | 2,200 ₹31,900 | 700 ₹10,150 |
| 10.00 | M&L for loose filling with aggregates of broken stone or boulders, of gauge 40 mm as in Rain water harvesting pits, soakage pits, soakage wells etc complete all as specified and directed. | 1 | Cum | 1,100 ₹1,100 | 2,600 ₹2,600 | 3,000 ₹3,000 | 3,200 ₹3,200 | 1,060 ₹1,060 |
Updated dates
Tender Value
₹33.7 L
EMD Value
₹68,000
Closing Date
6 Dec 2025, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR/ MAINTENANCE OF RESIDENTIAL / OFFICE COMPLEX AT OAQA, RAIPUR UNDER GE (I) RND DEHRADUN
2025_MES_740008_1
GE(I)RND/9518/E8/25-26
Open Tender
Civil Works
180 days
Dehradun
Class D Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I RND DEHRADUN
₹68,000
Yes
23 Dec 2025
15 Nov 2025
8 Dec 2025
15 Nov 2025
6 Dec 2025
22 Nov 2025
15 Nov 2025 - 22 Nov 2025
Amount
Surface excavation n.exc (not exceeding ) 30 cm deep and averegeing 15 cm deep getting out in any type of soil l etc complete all as specified and directed.
Excavating in trenches, in any type soil not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in any type of soil complete as specified and directed.
Excavating over areas, exc 1.5 m deep and and not exc 3.00 m deep and getting out in any type of soil complete as specified and directed.
Excavating over areas, exc 3.00 m deep and and not exc4.50 m deep and getting out in any type of soil complete as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distanc n exc 50 m and making good surface inany type of soil complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers n. exc. 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material soil exc 250m but not exceeding 500m & depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
M&L for loose filling with aggregates of broken bricks, half brunt of gauge 40 to 80 mm as in Rain water harvesting pits, soakage pits, soakage wells etc complete all as specified and directed.
M&L for loose filling with aggregates of broken stone or boulders, of gauge 40 mm as in Rain water harvesting pits, soakage pits, soakage wells etc complete all as specified and directed.
M&L for Pea Shingle filling, laid in layers n exc. 15 cm thick, spread, levelled as in Rain water harvesting pits, etc complete all as specified and directed.
M&L for Sand filling as in Rain water harvesting pits etc complete all as specified and directed.
M&L for cement concrete 1:4:8 Type D-2 using 40 mm graded crushed stone aggregate in foundation filling sub base and mass concrete complete all as specified and directed.
M&L Plain cement concrete 1:5:10 type E-2 (using 40mm graded stone aggregate as in foundation filling & Mass concrete , sub base complete all as specified and directed.
M&L for RCC M-25 design mix using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M-25 design mix using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintles over 1.5 m span complete all as specified and directed.
M&L for RCC M-25 design mix using 20 mm graded stone aggregate as in slab supported on walls, beams, and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for reinforced precast cement concrete(1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in landing, cover slab (for manholes, shelves), chullah hoods, chajjas, water troughs,mangers, shelves an similar articles with plain faces incluing necessary form work, & set in cement mortar (1:4) including demolition of old RCC covers of any description complete all as specified an directed. Note:-Reinforcement shall be measured and paid for separately in respective items
M&L for plain cement concrete(1:2:4) type B-1using 20 mm graded crushed stone aggregate as , in RCC lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed and the like with and including use and waste of form work complete all as specified an directed. Note:-Reinforcement shall be measured and paid for separately in respective items
M&L for PCC 1:3:6, type C-1 (using 20mm graded stone aggregate) as in surface channel and drain incluing necessary form work complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitred/stopped ends etc.
Supply only Liquid water proofing compound ISI Marked (used 200 ml per bag of cement) complete all as specified and directed.
M&L for Walling of random, rubble, stone masonary except stone brought upto courses, well bonded bedded and soilidly hearted and built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in 1:4 cement mortar complete all as specified and directed complete all as specified and directed.
M & L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., work in rough finished flat surfaces of concrete complete all as specified and directed.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M & L for used and waste for form work to edges of concrete flats, treads breaks of floor, openings in concrete wall, floor and roof, exc 10cm but n.exc 20cm wide and sides of bands in walls, horizontal or sloping for rough finished concrete surface complete all as specified and directed.
M&L for Use and waste of formwork as in foundation, footings, padestals and in PBs complete complete all as specified and directed.
Taking down shutters of any description exc 1 sqm & n. exc 2 sqm each complete all as specified and directed
Taking down Chowkats or frames with shutter (without taking off shutters from the frame) exc. 1.50 sqm and n. exc. 4.00 sqm each including removing from site complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
Taking down and re-fixing the same existing Aluminium door (each shutter area n. exc 4sqm) after carrying out repairs as required, removing the existing beading and fixing new rubber beading of suitable size with adhesive, overhauling of floor springs including greasing and oiling complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 150 mm long and fixed complete all as specified and directed.
S&F 100 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F aluminium handles, cast type, anodised 150 mm size complete all as specified and directed.
S&F floor door stopper double leg of aluminium alloy body of 70 mm length with aluminium base plate of size 50 mm x 40mm complete all as specified & directed.
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified and directed.
S&F in repair aluminium die cast body door closer hydrau lically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg complete all as specified and directed.
M & L for mild steel TMT bars of 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
M&L for providing and fixing 3 mm thick ACP (aluminium composit panel) sheet of approved colour as in signage board, supply and fixing to MS frame of channel/ angle or other sections at 2.5 m to 6.00 m height including drilling holes and fixing with bolts and nuts of suitable size complete all as specified and directed.
M&L for digital Vinyel printing of letters of figures (Black, roman, Indina along with installation on board size not less then 1.50m x 1.20m) as भारत सरकार रक्षा मंत्रालय अपर महानिदेशक का कार्यालय (उत्तर एवं मध्य अंचल) वैमानिक गुणवत्ता आश्वासन महानिदेशालय लखनऊ-226016 GOVERNMENT OF INDIA MINISTRY OF DEFENCE OFFICE OF THE ADDITIONAL DIRECTOR GENERAL NORTH & CENTRAL ZONE DIRECTORATE GENERAL OF AERONAUTICAL QUALITY ASSURANCE LUCKNOW-226016 with logo design complete all as specified and directed.
M&L for digital Vinyel printing of logo on exsiting board/ gate DIRECTORATE GENERAL OF AERONAUTICAL QUALITY ASSURANCE as directed by E-in-Charge.
S&F M S Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment & similar work conforming to Fe 410W (Gde E-250 quality-A) complete all as specified and directed.
S&F mild steel tubular work as in Roof trusses (framed) posts purlins, crane gantries, rails and fastenings and heavy brackets framing including special shaped washers etc, complete using ERW or induction butt welded tubes conforming to relevant IS code,grade st 240. complete all as specified and directed.
M&L for S&F stainless steel framed work such as in grills, gratings, etc. with end of bars shouldered and/or riveted , or forged in to spikes, framed guard bars, barred iron doors, ladders, framed blusters, walk ways, railings, frame work of water tanks and similar work complete all as specified and directed.
S & F M.S Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
M&L for suspended false ceiling system using chicago metallic (E grid)exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture with and including Dismantling of wall and ceiling boards any thickness including cover filletes complete all as specified and directed.
M&L for 12mm thick POP/gypsum board ceilng with concealed metal grid system comprising of 80 x 26 x 0.55mm as ceiling section 20 x 27 x 30 x 0.55mm as perimetar channel & 15 x 45 x 15 x 0.9mm as inter mediate channel complete. Frame structure suspend fram roof by ceiling angle of size 25 x 10 x 0.55mm with and including dismantling of wall and ceiling boards any thickness including cover fillets complete all as specified and directed.
M&L for 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking plat forms and like bedded in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admix ture of pigment to match with shade of granite, with and including dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L vitrified coloured tiles 10 mm thick darkt shade (square/rectangular) as in floors etc set and jointed in neat cement slurry area of each tiles exceeding 0.42 sqm but not exceeding 0.1.00 sqm and pointed in white or coloured cement to match including 15 mm thick cement screed bed in cement mortar 1:6 for laying floor finishes with complete all as specified and directed.
M&L for non skid Ceramic tiles,first quality( of approved class , colour and design/ shade) square/ rectangular) area of tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor surface etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles over and including 15 mm thick Screed bed in Cement mortar 1: 6, with and including dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L for glazed coloured ceramic tile, first quality( of approved class, colour and design/ shade) of size 300 x 450 / 350x450 / 350x250 thick in vertical surfaces, as in dado/skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with coloured tiles, over and including 10 mm thick rendering in cement mortar (1:4), rough finish to receive the tiles with and including dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone agg as in plinth protection laid in alterrnate panels and finish even and fair complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc with and including removing of debrish taking down plaster out side M.D land complete all as specified and directed.
M & L for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces with cement mortar 1:4finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete/brick surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for seprately as supply only under respective item of sch A/BOQ.
Material & Labourpreparing of new plastered surface on wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over 2 mm in two coat of water proof wall care putty including preparation of external surfaces of wall complete all as specified and directed.
M & L for preparation of newly plastered surface of wall and applying two coat of cement base paint complete all as specified and directed
M&L for complete removal of existing treatement by scraping, washing, rubbing down or stopping distempered or painted surfaces etc of walls plastered or un-plastered & removing all vegetation growth, cleaning & applying of Birla/JK white wall putty approx 1 mm thick as per manufacturer's instruction on existing prepared surface and make the surface smooth by rubbing with sand papers etc and applying two coats of oil emulsion distemper over a coat of water proof primer complete all as specified and directed.
M&L for preparing old surfaces of walls plastered or un-plastered by brooming down with steel or wire brush and scraping down smoke soot, moulds moss & efflorescent salt and trading oil and greasy spots , washing rubbing down and stopping of distempered and painted surface & removing all vegetation growth, nails and making good holes,cracks etc complete by necessary putty and make the surface smooth by rubbing with sand papers etc and applying one coat of distemper oil emulsion on old prepared surfaces of walls complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of ceiling, cornices etc by brooming down or steel wire brushing down scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coats of oil bound distemper complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/metal frames glazed with putty or fixed with beads including punching or drilling out old glazing pins/spring clips etc complete all as specified and directed.
M&L for 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
M & L preparation of new steel surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparing of old painted steel surfaces over 10cm width or girth and applying one coat of synthetic enamel paint on old prepared surfaces of steel complete all as specified and directed.
M&L for preparing of old painted wooden surfaces or wood based materials over 10cm width or girth with sand papers etc and applying one coat of synthetic enamel paint on old prepared surfaces of wooden complete all as specified and directed.
S & F in repair PVC (SWR) junction, with access door, single (single T) equal or unequal, for 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) pipes 150 mm,single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends any radius for 150 mm bore of pipe complete all as specified and directed.
S&F in repair25mm bore stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle chromium plated fancy type long shank and cup(concealed type), screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repair 20 mm bore dia of pipe gun metal globe of gate valves with iron wheel head screwed both endds for iron pipe and dixed complete all as specified and directed.
S&F for laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repair Waste coupling to WHB/ kitchen and laboratory sink of 32/40 mm dia complete all as specified and directed.
S&F in repair PVC Waste pipe to WHB/ kitchen sink of 32 mm dia complete all as specified and directed.
S&F bib cock long body with flange , fancy type, brass,chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest (excluding flushing cistern and flush pipe) & including CI trap & connecting fitting as required set in plain cement concrete (1:3:6) type C-1 and connecting to flusing cistern and trap & connecting fittings as required and making good to floor, complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm with & including one waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement ,with PVC coupling, PVC waste pipe 40mm bore 750mm long complete all as specified and directed. Make as approved by GE.
S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including bracket and PVC flush pipe 32 mm bore complete all as specified and directed.
S&F in repair vitreous china wash hand basin (flat back) of size 550x400mm including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector, MS brackets 2 numbers including cutting for and pinning in ends of brackets complete all as specified and directed.
S&F in repair bib cock long body with flange , fancy type, brass,chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed. Make as approved by GE.
S&F in repair fancy type angle cock with flange, 15 mm nominal bore, brass, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed. Make as approved by GE.
S&F in repair fancy type, stop cock regular body 15 mm nominal bore with flange, brass, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfllly handles, screwed both ends for iron pipe or for brass ferrule or to GI socket complete all as specified and directed. Make as approved by GE.
S&F in repair pillar taps, brass, with capston heads, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed. Make as approved by GE.
S&F in repair 125 mm size chromium plated brass shower rose with swivel joints and swivel arms for fixing with 15 mm pipe complete all as specified and directed.
S&F in repair towel rail ,D type, brass, chromium plated,, fancy type, 60 cm long between flanges fixed with and including CP brass screws, rawl plug etc complete all as specified and directed.
M&L for Cleaning of septic tank exc 50 users and n.exc 100 users by removing sluge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 KM but n. exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed .
M&L for Dewatering of soak well or sewage of any dia and depth manully or by using pumps and rremoval of sludge if any to a distance exc1.5km but not exc 2Km out of MOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for cleaning with suitable chemical of P/S trap of EWC/IWC etc by removing all blockage of any description in any situation in the system and removal of sludge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out ofMOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for cleaning of Nahani/floor trap of Bath/kitchen/urinal/ wash basin incluing Ist gully trap etc by removing all blockage of any description in any situation in the system and removal of sludge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out of MOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed .
M&L for cleaning of Sewage pipe line from gully trap to ISt manhole an then upto the final drop into the septic tank an soak well /cess pool (except intermediate manholes ) by removing all blockage of any description in any situation in the system complete any ia of pipe an epth by rodding ,manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out of MOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for cleaning of manholes any type-size and any depth by removing of sludge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out ofMOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description as in ground floors and pavings not exceeding 15cm thickness (above or below ground floors) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing with and including removing Debris out sideMOD Land at contractor is own arrangement complete all as specified and directed.
Supply and fxing UPVC perforated pipes (SCH-40) of 150 mm dia complete as specified and directed.
S&F perforated earthen pots of 250 mm dia complete as specified and directed.
M&L Trial bore of 250 mm dia upto 200 meter depth below ground level in any kind of soil strata including hard stone/boulder etc. complete all as specified and directed.
Taking down carefully existing points wiring on surface conduit/concealed conduit for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etc and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch.
All as per Sl item No 100 above herein before but one socket out let 5 pins 5 Amp on the independent board complete all as specified and directed.
All as per Sl item No 100 above herein before but one socket out let 5 pins 5 Amp on the same board but with other switches complete all as specified and directed.
All as per item No.100 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLS copper earth wire for modular switch socket combination 3 pin 15 amps on independent board
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module suitable for 15 Amp plug top Multipurpose 230 V complete,all as specified & directed.
S & F Modular Socket, 6A - 2/3 pin combined 2 module, 230 V complete,all as specified & directed.
S & F Modular Switch Piano flush type 6 amp single Pole one way 230 V complete,all as specified & directed.
S & F Modular switch 1 way 16A, 1 module flush type single Pole one way 230 V complete,all as specified & directed.
S & F Ceiling rose surface bakelite surface 65 x 50mm, 3 terminals complete,all as specified & directed.
S & F modular Switch Bell push 5 amp single Pole 230 V complete,all as specified & directed.
S & F Bell ding dong type, AC 230 volts complete,all as specified & directed.
S & F Lamp holder insulated body with back plate batten/angle type for batten fittings complete all as specified and directed.
S & F LED bulb 7 W complete all as specfied and directed
S&F in replacement of UNSV bulkhead fitting with integrated LED bulk head fitting 10W 600 lumens, 6000 K comprises of pressure die cast housing, acrylic diffuser and frame IP 65 protection, IK-07 etc including connection complete all as specified and directed. Make- C&G or equivalent in Havells/Phillips as approved.
Supply & Fixing LED light fitting 10 W batten (Mirror light) for Retro LED Energy saving tube light , high efficiency PMMA diffuser gives soft glare free light environmental friendly, energy efficient ready to use pack complete,all as specified & directed.
Supply & Fixing LED light fitting 20 W batten for Retro LED Energy saving tube light, high efficiency PMMA diffuser gives soft glare free light environmental friendly, energy efficient ready to use pack complete,all as specified & directed.
Supply & fixing in repair security Light of 60 watts of ENDURA CITYLITE PLATINUM PLUS New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with acrylic cover and accessories including housing suitable bracket, nuts & bolts, GI pipe complete all as specified and directed.
Taking down of ceiling fan 1200/1400 mm of any make & capacity from any height and removing its blades and refixing the same including material and labour for rewinding, with super enamelled copper conductor of suitable size, meet to original specification & speed including varnishing, heating etc including taking out old copper wire and painting of ceiling fans (Motor and blades etc) of existing colour or approved by GE with super enamelled paint one coat all as specified and directed.
Taking down of exhaust fan200/250/275/300 mm of any make & capacity from any height and removing its blades and refixing the same including material and labour for rewinding, with super enamelled copper conductor of suitable size, meet to original specification & speed including varnishing, heating etc including taking out old copper wire and painting of ceiling fans (Motor and blades etc) of existing colour or approved by GE with super enamelled paint one coat all as specified and directed.
Supplying, laying & jointing 50 mm bore GI water tubing, , light grade as in sleeving etc laid in trenches / ducts etc. complete all as specified and directed by Engineer-in-Charge.(MAKE : TATA/JINDAL/TT SWASTIK) 50 mm bore
Supplying, Laying, testing and commissioning in replacement 50Sqmm 4 core. XLPE insulated,IS 7098 (Part-I)-1988 marked screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 1100V grade cross section area of 50Sqmm 4 core size of cables laid in trenches/fixed on pole/wall / passed through pipe including making necessary connection, with busbar/MCCB/DB's & testing complete, all as specified and directed by Engineer-in-Charge. Make:Havells/CCI/ICL/GLOSTER/Incab/Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately )
Supplying, Laying, testing and commissioning in replacement 10Sqmm 2 core. XLPE insulated,IS 7098 (Part-I)-1988 marked screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 1100V grade cross section area of the 10Sqmm 2 core.size of cables laid in trenches/fixed on pole/wall / passed through pipe including making necessary connection, with busbar/MCCB/DB's & testing complete, all as specified and directed by Engineer-in-Charge. Make:Havells/CCI/ICL/GLOSTER/Incab/Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately )
Supply , Install and testing in replacement of unserviceable HT 11kV vertical swing triple pole gang operated air break switch (GOD) consisting of twelve insulator (3 insulators in each phase and one each for DO fuse). Mounted over the MS channel frame, operating mechanism, operating handle GI medium grade 25 mm bore, 5 mtr long with locking arrangement system connected with operating handle and 7 leaver lock of Godrej, moving and fixed jaws, copper jumpher strip etc suitable for 11000 volt 200 Amp current rating all as specified and directed at site.
Supply, fixing & testing in replacement of UNSV150W LED Flood light (Orange, White & Green) colour full IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing 16 mtrs High Mast/11 mtrs pole /9 mtrs poleor Bldg MS framewith and including GI pipe bracket including connecting the fitting complete all as specified and directed. Make- Crompton/Havells/C& S/Bajaj/Shakti
Supplying & fixing, testing in replacement UNSV of surface mounted in built , LED36watts, 2'x2' LED ceiling light fitting with slim line extruded aluminium/ CRCA body, opel acrylic diffuser, electronic driver etc and all accessories pre-wired including connecting to source complete all as specified and directed. Make- Crompton cat pt No- LCTLSNE36-FO-CDL or equivalent model of Havells / Philips as approved .
Supply and fixing in replacement intercom telephone 20 pair cable complete all as specified and directed
S & F modular electronic ceiling fan regulator stepped type 2 module 120 W heavy duty suitable to work on 230 volts complete all as specified.
M & L for Sub main wiring with 2 single core PVC insulated unsheathed cable, 1100v grade with FRLS PVC 6 sq mm copper cable multi stranded conductor drawn through in and including PVC rigid non metallic concealed conduit 20 mm dia, medium duty, ISI Marked to be terminated in DB box as per IS including of 6 sqmm dia FRLS PVC Copper cable green colour as earth wire connected to earth complete,all as specified & directed.
S & F MCB single pole, 240 volts, 6 Amps to 32 Amp breaking capacity 10KA(type 'C') complete,all as specified & directed.
Supply & Fixing MCB SPN, 240 Volts, 32 Amps breaking capacity 10 KA (type C curve) complete,all as specified & directed.
Supply and fixed in replacement of UNSV MCB 4 pole, 50/ 63 Amps 415 volts, 50 Hz 'C' Curve having breaking capacity 10 KA , with thermal magnetic protection unit and testing Complete all as specified and directed. Make- IndoAsian or equivalent in seimens / Schinder as approved by GE.
S & F sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified and directed.
All as per item No 130 above but SPN, 240 volts, 4 ways complete all as specified and directed by GE Make: Legrand/ Havells/ C&S/Indoasian.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 5 of 2009 (Part-I) including taking out old existing earthing complete all as specified & directed.
M&L for Un-reinforced precast concrete cable cover class LV type I, flat, size 250mm x 150mm x 40mm as proteciton to under ground cable laid dry flat adjoining each other complete all as specified and directed
10 KVA to 140 KVA, 3 phase 50 HZ, Make: CUMMINS/Kirloskar
Supply only lubrication oil SAE-40 ( 20 W- 40 grade) suitable for Engine of DG set any capacity drained out / filling under Sch `A` item No 134 here in above complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor, complete, all as specified and directed.
M/s Gupta Associates (BID ID -3485518)
Sharda Enterprises (BID ID -3491093)
M/S VIJAY TRADERS (BID ID -3485960)
M/S Anil kumar (BID ID -3489372)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Genpage9518.pdf
Tender Documents • 0.98 MB
BOQ_828609.xls
BOQ • 1.29 MB
Download all tender documents and submit your bid