Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹4.3 L+₹21,855 (5.31%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹4.8 L+₹65,125 (15.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹4.8 L+₹72,290 (17.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹5.1 L+₹1.0 L (25.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
27 Dec 2024, 6:00 pmClosed
AGE (I) Dharamshala
AGE (I) Dharamshala PIN-176216
Repair, replacement of existing unserviceable distribution boards with MCBs, DB Box, sub main wiring, services connections and other connected works Tirah line at Mil Stn Dharamshala
2024_MES_686222_1
AGE (I)/DSL-45/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
MIL STN Dharamshala
As per NIT
8 documents required · 8 mandatory
₹500
AGE (I) Dharamshala
₹19,000
Yes
10 Mar 2025
29 Nov 2024
30 Dec 2024
29 Nov 2024
27 Dec 2024
13 Dec 2024
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheating FRLS electric cable 1100 volts cable in and including PVC casing and caping of suitable size (as per conductor run) with all fittings such as bend/corners/ accessories and including PVC insulated electric cable 1100 volts 1.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly in existing CI/wooden/pvc box covered with 3 mm thick plastic laminated sheet for one light point/ fan/exhaust fan point/ bell point etc controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge. Note :- (i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 2 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
M&L for switch socket combination 2 in 1, 5 Amp and 15 Amp flush type all as specified and directed.
M&L for Switch socket combination 2 in 1, 5 A flush type all as specified and directed.
Material and labour for Bell push Switch flush button single pole one way 5 Amps complete
M&L for Sub main wiring in PVC casing caping/conduit with 2 Nos single core PVC insulated copper conductor cable flame proof size 6.0 sqmm multistrand and 4.0 sqmm PVC insulated flame proof earth wire using suitable size of copper thimble all as directed
M&L for Sub main wiring in PVC casing caping/conduit with 2 Nos single core PVC insulated copper conductor cable flame proof size 4 sqmm multistrand and 2.5 sqmm PVC insulated flame proof earth wire using suitable size of copper thimble all as directed
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 4 way double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of current carrying capacity SP 5 to 32 Amp MCB complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of current carrying capacity SPN 32 Amp MCB complete with connection testing and commissioning.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with DB’s suitable for MCBs of triple pole and neutral 4 way, 415 volt, double door type with 200 amp rated bus bar double door type with one incoming and 12 outgoing Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job.
Supply and fix in replacement of MCB TPN 63 Amp all as specified and directed. Make: Havells Cat Part No :DHMGCTNF040
Supply and fixing (in repair/replacement) decorative wall mounting fixture, in durable plastic body & designer mesh in gold finish suitbale for 9 W lamps, three core flexible copper conductor cable, 9 W LED buld all as specified and as directed. Make- HPL, Bajaj, Havells, CG etc.
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge. Make : Plaza /SSK/Cona/Havells
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 10sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apartincluding4mm suspension wire, one twin core cable flat or circular
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I & as directed by Engr-in-Charge
Material and labour for sheet metal enclosure (DB Box) of size 750x600x300mm or as per site requirement, made out of 2mm thick MS sheet suitable for fixing the MCB DB & meters, single door type with locking arrangement and reconnecting commissioning including 2 coats of synthetic enamel paint over a coat of red oxide primer to internal and external surfaces with machine spray, necessary cutting, PCC work, disturbed surfaces match to existing surface complete included in the job complete all as specified and directed by Engr-in-Charge
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
Supply and fixing LED tube rod/ultra bright tubelight 20 Watts (single side connection) with very high efficacy and best suited for installation in existing tubelight luminaire with any type of existing lamp holders to give the glare free light with lamp holder as per site requirement and as directed.
Supply and fix electronic meters single phase temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with Prameters to show data, time, current reading, load, PF, voltage and KWH including removal old unsv energy meter any type and make all as specified and directed by Engr-in-Charge. Note : Old unsv energy meter to be deposited to MES store.
Supply and fix electronic meters three phase temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWHincluding removal old unsv energy meter any type and make all as specified and directed by Engr-in-Charge. Note : Old unsv energy meter to be deposited to MES store.
KONARK ENTERPRISES (BID ID -3194247)
Him Builders (BID ID -3193635)
JAI DURGA CONSTRUCTION CO (BID ID -3200216)
M/S MALHI CONSTRUCTIONS (BID ID -3200142)
smc engineering company (BID ID -3200029)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .