Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC NEAR GOVT U P SCHOOL PSARA 10 PADAMUGAL KAKKANAD KOCHI PADAMUGAL | KOCHI | ERNAKULAM | KERALA | 682030 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹19.7 L+₹1.3 L (6.98%)Rejected-AOC NO 9B 18 STREET TANSI NAGAR EXTN VELACHERY CHENNAI TAMILNADU 600042 | CHENNAI | CHENNAI | TAMIL NADU | 600042 | L2 | Rejected-AOC second lowest | |
| 3 | L3₹20.8 L+₹2.4 L (13.0%)Rejected-Finance | L3 | Rejected-Finance third lowest | |
| 4 | L4₹26.2 L+₹7.8 L (42.5%)Rejected-Finance NULL | L4 | Rejected-Finance fourth lowest |
Tender Value
₹23.9 L
EMD Value
₹50,000
Closing Date
12 Oct 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
PWD Roads Division Thiruvananthapuram
Investigation Estimate- Kattakkada Junction Improvement and Ring Road development.
2020_PWD_388715_1
PWD/2020-2021/15317/RdDIVTVM
Open Tender
Civil Works - Roads
Item Rate
150 days
PWD Roads Division Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
online
₹50,000
Yes
17 Nov 2020
30 Sept 2020
14 Oct 2020
30 Sept 2020
12 Oct 2020
30 Sept 2020
60 days
Amount
TOTAL STATION SURVEY
56.12.b : Total station surveying and preparation of site plan for plain built up area with hindrance to line of sight due to buildings/structures.Total station surveying and preparation of site plan for plain built up area with hindrance to line of sight due to buildings/structures.
COLLECTION OF SUB GRADE SOIL
od5667/2020_2021 : Collection of soil samples from subgrade for soil classification tests, Standard Proctor test and CBR test - Collection of sub-grade soil samples at one location as suggested by the engineer - in - charge - carefully by excavating pit of area 1mX0.6m from subgrade of formation area (30cm below original shoulder level) as directed by the engineer in charge for laboratory test and refilling back and compacting the excavated pit to lines and levels with excavated materials as directed by the departmental officers at site.
TESTING OF SOIL - Sieve Analysis (Wet Sieve + Hydrometer), Atterberg Limit (LL,PL,SL,PI), Modified Proctor Compaction, 4 day soaked CBR, Moisture Content/FDD existing
od5668/2020_2021 : Conducting Soil Classification tests, Standard Proctor test and CBR test as per the Indian Standard code specifications - Conducting the test as per IS code guidelines and preparing result of one soil sample
SUB SOIL INVESTIGATION - MACHINE BORING
56.1.a : Mobilization including transportation of all necessary plan and equipment's and materials of boring field testing and sampling and demobilization after completing the work<br>For machine boringMobilization including transportation of all necessary plan and equipment's and materials of boring field testing and sampling and demobilization after completing the workFor machine boring
56.2.a : Setting up boring at each bore hole locations including carrying all necessary plant, equipment and materials of boring and field tests and collection of samples at each bore hole location.<br>For machine boring.Setting up boring at each bore hole locations including carrying all necessary plant, equipment and materials of boring and field tests and collection of samples at each bore hole location.For machine boring.
56.3.a.1 : Boring with rotary power drilling equipment's in all types of soil having N value less than 50 excluding hard rock soft rock, or medium rock for strata upto 10m. Including conducting necessary S.P.T and recovery of un disturbed soil samples at 5m.intervals.<br>For ordinary soil.Boring with rotary power drilling equipment's inall types of soil having N value less than 50 excluding hard rock soft rock, or medium rock for strata upto 10m. Including conducting necessary S.P.T and recovery of un disturbed soil samples at 5m.intervals.For ordinary soil.
56.3.b.1 : Boring with rotary power drilling equipment in all types of soil having N value less than 50 excluding hard rock soft rock, or medium rock for strata for next 10m upto a depth of 20m including conducting necessary S.P.T and recovery of un disturbed soil samples at 5m.intervals.<br>For ordinary soilBoring with rotary power drilling equipment in all types of soil having N value less than 50 excluding hard rock soft rock, or medium rock for strata for next 10m upto a depth of 20m including conducting necessary S.P.T and recovery of un disturbed soil samples at 5m.intervals.For ordinary soil
56.3.c.1 : Boring with rotary power drilling equipment in all types of soil having N value less than 50 excluding hard rock soft rock, or medium rock for strata for next 20m upto 30m depth including conducting necessary S.P.T and recovery of undisturbed soil samples at 5m.intervals.<br>For ordinary soil.Boring with rotary power drilling equipment inall types of soil having N value less than 50 excluding hard rock soft rock, or medium rock for strata for next 20m upto 30m depth including conducting necessary S.P.T and recovery of undisturbed soil samples at 5m.intervals.For ordinary soil.
56.5.a : Boring through all classes of rock excluding hard rocks having ' N' value greater than 50 using tungsten carbide drilling bit.<br>In land.Boring through all classes of rock excluding hard rocks having ' N' value greater than 50 using tungsten carbide drilling bit.In land.
56.4 : Boring through all type of hard rock or similar refusal strata of N value greater than 50 using diamond core drilling bit for in land under and banks of river.Boring through all type of hard rock or similar refusal strata of N value greater than 50 using diamond core drilling bit for in land under and banks of river.
56.6 : Recovering undisturbed soil samples using thin tube sampler of 75mm.to 100mm length internal dia 500mm length conforming to relevant IS Code at any required depth including clearing the bore hole etc complete.Recovering undisturbed soil samples using thin tube sampler of 75mm.to 100mm length internal dia 500mm length conforming to relevant IS Code at any required depth including clearing the bore hole etc complete.
56.7 : Conducting standard penetration test in bore hole at any depth.Conducting standard penetration test in bore hole at any depth.
56.8 : Recovering disturbed samples and preserving the same in air tight sample containers including waxing labelling packing storing including cost of containers as per IS Code.Recovering disturbed samples and preserving the same in air tight sample containers including waxing labelling packing storing including cost of containers as per IS Code.
56.11.a : Compilation of all field data with recommendation for a suitable foundation after conducting necessary lab test (report in triplicate)<br>Machine boring for 5 bore holes.Compilation of all field data with recommendation for a suitable foundation after conducting necessary lab test (report in triplicate)Machine boring for 5 bore holes.
TRAFFIC STUDY
INVENTORY OF ROAD &amp;amp;amp;amp;amp; CD STRUCTURES
od5670/2020_2021 : Data for Inventory survey for upto 12 metre wide road-including Survey work for collecting the details of road inventories and recording in the prescribed format as per IRC based on chainage marking including marking chainage at 50m interval and taking details such as existing carriage way width, shoulder width, type of shoulder, width and location of approach road, details of existing drains,culverts and bridges as given in the prescribed format attached, pavement conditions (details of pot holes, ravelling, fog seal,slurry seal,edge damage etc.) road safety measures(details of road sign,crash barriers,guard stones,delineator post,hazard markers, etc.) and all other existing retaining structures in road,including documentation charges etc. as per the direction of the officers at site.
PAVEMENT COMPOSITION
od5671/2020_2021 : Cutting open pit at the tar edge to get the details of the layers (thickness and type) of pavement composition - at one location as suggested by the engineer - in - charge - carefully - by excavating pit of area 1mX0.6m through overlying bituminous and granular layer ( including BC, DBM/BM, WMM & GSB)at tar edge and refilling back and compacting the excavated pit to lines and levels with excavated materials as directed by the departmental officers at site and reporting the pavement composition with photographs and measurements specifying the type of layer.
VELCITI CONSUTING ENGINEERS PVT LTD
THIXOTROPY DESIGN AND CONSTRUCTION SOLTU P LTD
G S Infrastructure
Bidder Name
G S Infrastructure
VELCITI CONSUTING ENGINEERS PVT LTD
AA AND S CONSTRUCTIONS
THIXOTROPY DESIGN AND CONSTRUCTION SOLTU P LTD
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_552663.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .