Loading…
Loading…
Tender Value
₹41.6 L
EMD Value
₹83,270
Closing Date
8 Aug 2026, 11:00 pm
Karnataka Power Corporation Limited
VENKATESH G
8277502863
Routine, Breakdown and preventive Illumination maintenance at CHP area for a period of one year
KPCL/2026-27/PS/WORK_INDENT4499
KPCL/2026-27/PS/WORK_INDENT4499
Open
Power stations
Two Tender Document System(Two Cover)
KPCL Executive Engineer CHPE1 Office RTPS Raichur
8 documents required · 4 mandatory · 4 optional
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
Proposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)
Intending Bidder should have satisfactorily completed as a prime contractor, at least one similar work such as in the field of supply, installation of electrical accessories & electrification work including maintenance works of power supply equipment/ Maintenance of Illumination system of value not less than Rs.24.57 lakhs in the last five years (2021-22, 2022-23, 2023-24, 2024-25 and 2025-26) in any Thermal power stations. As a proof of this the bidder shall upload single work order and corresponding work done certificate issued by the competent authority. (Work done of previous years shall be given weightage of 10% per year to bring them to the present price level of the financial year).
Intending Bidder shall be Class-I or above electrical contractor. As a proof of this, valid Electrical license issued by competent authority of Govt. of Karnataka shall be furnished.
The intending bidder in his name should have achieved an average annual financial turnover of Rs. 49.13 lakhs in any two financial years during the last five years (2021-22, 2022-23, 2023-24, 2024-25 and 2025-26). As a proof of this, the bidder shall upload the certified copy of profit & loss or turnover certificate duly certified by chartered accountant. (Financial turnover of previous years will be given weightage of 10% per year to bring them to the present price level of the financial year).
₹1,050
₹83,270
25 Jul 2026
25 Jul 2026
10 Aug 2026
4 Aug 2026
6 Aug 2026
Routine, Breakdown and preventive Illumination maintenance at CHP area for a period of one year
Heat shrinkable straight through joint (LT UG cable) -2.5 to 25 sqmm
Heat shrinkable straight through joint (LT UG cable) - 35 to 95 sqmm
Heat shrinkable straight through joint (LT UG cable) - 120 to 240sqmm
Heat shrinkable straight through joint (LT UG cable) - 300 to 400 sqmm
Laying of cable in Existing trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.
-2.5 to 25 sq.mm.
Laying of cable in Existing trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. -35 to 95 Sqmm
Laying of cable in Existing trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. -120 to 240 sq.mm
Laying of cable in Existing trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.-300 to 400 sq.mm
Fixing of …….Amps TPST/change over switch /contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST
Fixing of …….Amps TPST/change over switch /contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling. 100A to 250A TPST
Erection of single phase preventer / ammeters / including fixing selector switch / voltmeter / current operated earth leakage circuit breakers / voltage operated circuit breaker / above 100A fuse chan...
Fixing a ceiling/wall mounting fan of all capacities and all types to the existing "s" hook with fan regulator to the existing board together with supplying and fixing 5 Amps ceiling rose, necessary l...
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.
Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, r...
Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wi...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Releasing the existing FTL fitting of all capacities, checking, testing and installing at same place.
Releasing the existing fan checking, testing and installation at the same place.
Releasing the existing fan checking, testing and installation at the New place.
Supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade, copper conductor flexible multistrand FRLS PVC insulated , 2 X1.5Sqmm cable confirming to the GTP, w...
Supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade, copper conductor flexible multistrand FRLS PVC insulated , 2 X1.5Sqmm cable confirming to the GTP, w...
Supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade, copper conductor flexible multistrand FRLS PVC insulated , 2 X1.5Sqmm cable confirming to the GTP, w...
Supplying heavy gauge PVC conduit pipe . dia .mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling ...
Supplying heavy gauge PVC conduit pipe . dia .mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling ...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module
Supplying 2 to 4 way plastic gang box and fixing using necessary wooden/ rawl/phill plugs and screws.
Supplying 6 to 10 way plastic gang box and fixing using necessary wooden/ rawl/phill plugs and screws.
Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 8" x 6"...
Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 10" x 8...
Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall us...
Rewinding a 1200 mm ceiling fan/after using necessary gauge annealed and insulated copper wire with necessary insulating, separators vibration arresting shellac, etc including replacement of bearings ...
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights...
Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior F...
Releasing of 70/125/150 Watts HPMV/SV/MH, LED tube, round/square recess/surface mounted LED and 40/45/50/65/70/80/100 LED Lamps, cleaning, checking, Repairing, testing and installing at same place/new...
Releasing of 400/250 Watts HPMV/SV/MH Lamps, 150/200W LED Flood lights, street/pole lights and 1000/500W Halogen lamps, cleaning, checking, Repairing, testing and installing at same place/new place.
Releasing of 80/100/120/150/200/240/250 Watts LED flood light/high bay Lamps of Structural High mast and polygon lighting mast and high bay, cleaning, checking, Repairing, testing and installing at sa...
Replacement, termination and dressing of flexible copper/Aluminium armoured cable of Structural Light Mast.
Replacement, termination and dressing of flexible copper cable of Polygonal Light Mast.
Servicing of Main lighting Distribution Boards as directed by the departmental staff.
Servicing of lighting equipments, Lighting Panels and street light poles in CHP 1&2 as directed by the departmental staff.
Servicing of Three phase Rewireable Switch Fuse Unit/Flame proof Industrial type welding supply points and Change over switches.
Servicing of Structural Light Mast and Polygonal Light Mast
Overhauling or replacement of Polygonal Light Mast motors
Fuse of calls- to attend the emergencies (at night/other than working hours)
Supervision of the complete work "Routine, Breakdown and preventive Illumination maintenance at CHP area"
Rewinding a 300/400 mm wall mounting fan/single phase exhaust fan/ after using necessary gauge annealed and insulated copper wire with necessary insulating, separators vibration arresting shellac, etc...
Fixing of MS/Die cast aluminium Junction box with Terminal strip, DIN mounting rail, fasteners and allied accessories. Fixing angle iron frame work fabricated out of M.S. angle iron and M.S. Flat with...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
TENDER DOCUMENT 2026-27.pdf
Tender Document • 0.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].