Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.6 L+₹4,063.05 (0.10%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹42.7 L
EMD Value
₹50,000
Closing Date
23 Nov 2019, 3:30 pmClosed
AEE, LSGD Division, Thiruvannathapuram D P, Pattom
O/o the Executive Engineer, LSGD Division, Thiruvananthapuram D P, Pattom, Tvm - 695003
Please refer tender documents
2019_LSGD_321154_11
e-17/EE/LSGD/2019-20
Open Tender
Civil Works - Buildings
Item Rate
180 days
Pallickal
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,760
Yes
online
₹50,000
Yes
10 Aug 2020
15 Nov 2019
27 Nov 2019
15 Nov 2019
23 Nov 2019
15 Nov 2019
Amount
Finishing
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sectionsas per the architectural drawings and approved shop drawings , the aluminiumquality as per grade 6063 T5 or T6 as per BS 1474,including super durable powdercoating of 60-80 microns conforming to AAMA 2604 of required colour and shadeas approved by the Engineer-in-Charge. ( The item includes cost of material suchas cleats, sleeves, screws etc. necessary for fabrication of extruded aluminiumframe work. Nothing extra shall be paid on this account).
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi(grid) unitized system of structural glazing (with open joints) for linear as well ascurvilinear portions of the building for all heights and all levels, including:a) Structural analysis & design and preparation of shop drawings for the specifieddesign loads conforming to IS 875 part III (the system must passed the proof testat 1.5 times design wind pressure without any failure), including functional designof the aluminum sections for fixing glazing panels of various thicknesses, aluminiumcleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clampsetc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmokeseals, microwave cured EPDM gaskets for water tightness, pressureequalisation & drainage and protection against fire hazard including:b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3Dimentional movement for achieving perfect verticality and fixing structural glazingsystem rigidly to the RCC/ masonry/structural steel framework of building structureusing stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetalliccontacts with nuts and washers etc. of stainless steel grade 316, of the requiredcapacity and in required numbers.c) Providing and filling, two part pump filled, structural silicone sealant and onepart weather silicone sealant compatible with the structural silicone sealant ofrequired bite size in a clean and controlled factory / work shop environment ,including double sided spacer tape, setting blocks and backer rod, all of approvedgrade, brand and manufacture, as per the approved sealant design, within and allaround the perimeter for holding glass.d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thickand of sizes, shapes and profiles, as required as per the site conditions, to seal thegap between the building structure and all its interfaces with curtain glazing tomake it watertight.e) Making provision for drainage of moisture/ water that enters the curtain glazingsystem to make it watertight, by incorporating principles of pressure equalization,providing suitable gutter profiles at bottom (if required), making necessary holesof required sizes and of required numbers etc. complete. This item includes costof all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges includingwastages etc., enabling temporary structures and services, cranes or cradles etc.as described above and as specified. The item includes the cost of getting all thestructural and functional design including shop drawings checked by a structuraldesigner, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of theindividual components for testing in an approved laboratory, field tests on theassembled working structural glazing as specified, cleaning and protection till thehanding over of the building for occupation. In the end, the Contractor shall providea water tight structural glazing having all the performance characteristics etc. allcomplete as required, as per the Architectural drawings, as per item description,as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extrudedaluminium section capping for fixing in the grooves of the curtain glazing andvermin proof stainless steel wire mesh shall be paid for separately under relevantitems under this sub-head. However, for the purpose of payment, only the actualarea of structural glazing (including width of grooves ) on the external face shallbe measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazingsystem if area of structural glazing exceeds 2500 Sqm from the certified laboratoriesaccreditated by NABL(National Accreditation Board for Testing and CalibrationLaboratories), Department of Science & Technologies, India. Cost of testing ispayable separately. The NIT approving authority will decide the necessity of testingon the basis of cost of the work, cost of the test and importance of the work.Performance Testing of Structural glazing systemTests to be conducted in the NBL Certified laboratories1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to+300pa) as perASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testingmethod for a range up to 2000 ml.”3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testingmethod for a range upto 2000 ml”4. Structural Performance Deflection and deformation by static air pressure test(1.5 times desing wind pressure without any failure) as per ASTME-330-10 testingmethod for a range upto 50 mm”5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method forQualitative test” Tests to be conducted on site6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi)upto 2000ml”
25.7 : Designing, fabricating, testing, installing and fixing in position Curtain Wall withAluminium Composite Panel Cladding, with open grooves for linear as well ascurvilinear portions of the building , for all heights and all levels etc. including:a) Structural analysis & design and preparation of shop drawings for pressureequalisation or rain screen principle as required, proper drainage of water to makeit watertight including checking of all the structural and functional design.b) Providing, fabricating and supplying and fixing panels of aluminium compositepanel cladding in pan shape in metalic colour of approved shades made out of4mm thick aluminium composite panel material consisting of 3mm thick FR grademineral core sandwiched between two Alumini um sheets (each0.5mm thick). Thealuminium composite panel cladding sheet shall be coil coated, with Kynar500based PVDF / Lumiflon based fluoropolymer resin coating of approved colourand shade on face # 1 and polymer (Service) coating on face # 2 as specified usingstainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backerrods etc.c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanisedwith serrations and serrated washers to arrest the wind load movement, fasteners,SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators toprevent bi-metallic contacts all complete required to perform as per specificationand drawing The item includes cost of all material & labour component, the cost ofall mock ups at site, cost of all samples of the individual components for testing inan approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wallwith aluminium composite panel cladding till the handing over of the building foroccupation. Base frame work for ACP cladding is payable under the relevantaluminium item.s The Contractor shall provide curtain wall with aluminiumcomposite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per theapproved shop drawings and as directed by the Engineer-in-Charge.However, for the purpose of payment, only the actual area on the external face ofthe curtain wall with Aluminum Composite Panel Cladding (including width ofgroove) shall be measured in sqm. up to two decimal places.
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
od375573/2019_2020 : Supplying and fixing stadium floor mounted fiber chairs premium quality with all fittings like clamps, nut and bolt etc complete.
od375574/2019_2020 : Synthetic rubber mat flooring for indoor stadium with15mm thick 1m x1m interlocking tiles etc complete
50.12.2.4 : Providing & fixing Poly carbonate multi wall plain sheet 6 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12m or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/self tapping screw of size (5.5x55mm) with EPDM seal complete upto any pitch in horizontal/vertical curved surfaces, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.
od377719/2019_2020 : Providing and fixing exhaust air turbo ventilator including all labour charges etc complete
Toilet block
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
od373249/2019_2020 : Dry rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand: 12 graded stone aggregate 20 mm nominal size).
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
50.9.3.1 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood
50.9.4.1 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood
50.9.6.1 : Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood / jack wood 30 mm thick shutters
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
17.2.2 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked black solid plastic seat and lid
17.23 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
17.25.2 : Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:Flat back wash basin of size 550x400 mm
50.17.1.4 : Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
50.18.7.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall
50.18.7.4.2 : Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall
50.18.9.9.2 : Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
od380138/2019_2020 : Supplying and fixing PVC door with all fittings etc complete
16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
od389644/2019_2020 : Supplying and fixing granite name board 75*60 cm size on brick wall with engraving letters as per the direction Dept Enginieers
od389645/2019_2020 : Supplying and fixing information board 75*60 cm size MS sheet 1 mm thick on GI pipe
Ajayakumar T
Bidder Name
Mangalathu builders and contractors
Ajayakumar T
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_443377.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .