Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC | ₹5.1 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹5.1 LRejected-AOC 25 P NO 310 | ₹5.1 L | L2 | Rejected-AOC Rejected |
| 3 | L3₹5.1 LRejected-AOC AYILLYAM H AYIKKARAPADI PO CHERUKAU PIN 673637 | MALAPPURAM | KERALA | 673637 | ₹5.1 L | L3 | Rejected-AOC Rejected |
| 4 | L4₹5.4 LRejected-AOC | ₹5.4 L | L4 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | ANIL KUMAR O L3 | SHAJI P L2 | MOHANAN T L1 | N K RAMADASAN L4 |
|---|---|---|---|---|---|---|---|
| 1.00Providing additional Electrification for the Installation for A/C units in Various sections in Administrative Block at GHMC,KKD | |||||||
| 1.00 | OD281744/2025-2026:Supply and providing Ready to use Sub Main Distribution Board with IP 43 protection complying to IEC 61439-2 with copper bus bar 250 A , neutral link, earth bus, Metering extension box with voltmeter with selector switch & 3 Nos ammeters and RYB indicators at top, Side cable box both left and right, Bottom cable box, Corner box 4 nos etc suitable for providing 4 pole MCCBs as incoming and 4 nos 3pole MCCB's are outgoing fixed directly on wall using necessary anchor bolts including drilling hole on the wall , making good the damages, colour washing etc. as required . All the DB enclosure and including side, top, bottom and corner boxes are original company make. Neatly cable tie in the cable chamber. cable bending shall be as per standard and providing without stress and strain. MCCB Load Bank L&T ENERSYS-s 250A O/G , 100A 4way outgoings. or equivalent | 1 | each | 88,750 ₹88,750 | 88,724.37 ₹88,724.37 | 88,700 ₹88,700 | 88,900 ₹88,900 |
| 1.00 | 90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) | 1 | each | 7,683.36 ₹7,683.36 | 7,683.36 ₹7,683.36 | 7,600 ₹7,600 | 7,700 ₹7,700 |
| 1.00 | 90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) | 1 | each | 2,871.34 ₹2,871.34 | 2,871.34 ₹2,871.34 | 2,800 ₹2,800 | 2,900 ₹2,900 |
| 1.00 | 90.14.10.14:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC | 1 | no | 26,707.09 ₹26,707.09 | 26,707.09 ₹26,707.09 | 26,700 ₹26,700 | 27,000 ₹27,000 |
| 1.00 | 90.14.10.11:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC | 1 | no | 17,759.38 ₹17,759.38 | 17,759.38 ₹17,759.38 | 17,700 ₹17,700 | 18,000 ₹18,000 |
| 1.01 | 90.14.10.1:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL | 4 | no | 3,829.12 ₹15,316.48 | 3,829.12 ₹15,316.48 | 3,800 ₹15,200 | 3,900 ₹15,600 |
| 1.01 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | 1 | each | 1,093.28 ₹1,093.28 | 1,093.28 ₹1,093.28 | 1,090 ₹1,090 | 1,093 ₹1,093 |
| 1.01 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415
volts, residual current circuit breaker (RCCB), having a sensitivity current 30
milli Amperes in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
63 amps | 1 | each | 3,037.88 ₹3,037.88 | 3,037.88 ₹3,037.88 | 3,030 ₹3,030 | 3,030 ₹3,030 |
| 1.01 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | 12 | each | 270.65 ₹3,247.80 | 270.65 ₹3,247.80 | 270 ₹3,240 | 280 ₹3,360 |
Tender Value
Refer Docs
EMD Value
₹12,711
Closing Date
10 Feb 2026, 4:00 pmClosed
AEE
PWD ESD KOZHIKODE
DEPOSIT-Airconditioning of Senior AO Room Store -Bill section room CA Room Fair copy section Providing additional Electrification for the Installation for A/C units-General Electrical Work
2026_PWD_833104_1
PWD/BLDG/TR/7098/2024
Open Tender
Electrical Works
90 days
GMC Kozhikode
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,125
₹12,711
18 Apr 2026
3 Feb 2026
12 Feb 2026
3 Feb 2026
10 Feb 2026
3 Feb 2026
Providing additional Electrification for the Installation for A/C units in Various sections in Administrative Block at GHMC,KKD
90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.14.10.14:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.11:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.1:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
90.12.7.33:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm
90.16.1.9:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.64 mm GI conductor (12 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.23:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
1.17.27:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 4 sq. mm
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
OD281750/2025-2026:supply and fixing Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia.
OD281751/2025-2026:Supply and Providing Blue Colour LED Indicator
OD281752/2025-2026:Supply and Providing 3Phase Voltmeter accuracy class 1
OD281757/2025-2026:Supply and fixing single Phase Ammeter accuracy class 1
OD281761/2025-2026:Supply, providing and fixing 250/5 A, 5 VA, accuracy class 1, Tape wound Metering CT
OD283073/2025-2026:Supply and Fixing of Spreader terminals adaptors kit (8pic) for MCCB 200A
OD283074/2025-2026:Supply and Fixing of Spreader terminals adaptors kit (8pic) for MCCB 125A
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.26:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
OD291897/2025-2026:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.5 cm, 4 cm, 5 cm height
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1400815.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.03 MB
nitaoroom.pdf
Tender Documents • 0.02 MB
sbdaoroom.pdf
Tender Documents • 1.92 MB
MLAO.pdf
Tender Documents • 0.18 MB
BOQ_1400815.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid