Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAccepted-AOC | ₹2.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹2.3 LRejected-AOC KOLLAM | KOLLAM | KERALA | 689694 | ₹2.3 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | RAMESAN S L1 | Ashokkumar.k L2 |
|---|---|---|---|---|---|
| 1.00vetenary hospital | |||||
| 1.00 | 18.42.2:Boring with 100 mm diameter casing pipe for hand pump/ tube well in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump/tube well is lowered and tested:Beyond 6 m and upto 12 m depth | 56 | metre | 916.64 ₹51,331.84 | 1,017.47 ₹56,978.32 |
| 1.00 | 50.18.9.14.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall | 30 | metre | 348.81 ₹10,464.3 | 387.18 ₹11,615.4 |
| 1.00 | OD361470/2025-2026:Supplying and fitting 0.50HP motor including all charges | 1 | each | 7,360.9 ₹7,360.9 | 8,170.6 ₹8,170.6 |
| 1.00 | 50.18.9.13.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 12 Kgf/ cm2- External work- exposed on wall | 25 | metre | 325.7 ₹8,142.5 | 361.53 ₹9,038.25 |
| 2.00Anganwadi No:106 | |||||
| 2.00 | 18.42.2:Boring with 100 mm diameter casing pipe for hand pump/ tube well in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump/tube well is lowered and tested:Beyond 6 m and upto 12 m depth | 45 | metre | 916.64 ₹41,248.8 | 1,017.47 ₹45,786.15 |
| 2.00 | 50.18.9.14.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall | 30 | metre | 348.81 ₹10,464.3 | 387.18 ₹11,615.4 |
| 2.00 | OD361471/2025-2026:Supplying and fixing 0.5HP motor etc as per instruction of Engineer in charge | 1 | each | 7,360.9 ₹7,360.9 | 8,170.6 ₹8,170.6 |
| 2.00 | 50.18.9.13.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 12 Kgf/ cm2- External work- exposed on wall | 25 | metre | 325.7 ₹8,142.5 | 361.53 ₹9,038.25 |
Tender Value
₹2.1 L
EMD Value
₹5,282
Closing Date
27 Jan 2026, 6:00 pmClosed
ASSISTANT ENGINEER
OFFICE OF THE ASSISTANT ENGINEER LIDEW SECTION THAZHAVA
Annual Plan202526Thazhava Grama Panchayth Tube well for Veterinary Hospital Anganavadikal 106 108 proj no 106
2025_LSGD_818317_6
6/AE/LIDEW/25-26
Open Tender
Civil Works - Others
180 days
Thazhava
Please refer Tender documents.
3 documents required · 3 mandatory
₹555
₹5,282
Yes
16 Apr 2026
20 Jan 2026
30 Jan 2026
20 Jan 2026
27 Jan 2026
20 Jan 2026
vetenary hospital
18.42.2:Boring with 100 mm diameter casing pipe for hand pump/ tube well in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump/tube well is lowered and tested:Beyond 6 m and upto 12 m depth
50.18.9.14.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall
OD361470/2025-2026:Supplying and fitting 0.50HP motor including all charges
50.18.9.13.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 12 Kgf/ cm2- External work- exposed on wall
Anganwadi No:106
18.42.2:Boring with 100 mm diameter casing pipe for hand pump/ tube well in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump/tube well is lowered and tested:Beyond 6 m and upto 12 m depth
50.18.9.14.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall
OD361471/2025-2026:Supplying and fixing 0.5HP motor etc as per instruction of Engineer in charge
50.18.9.13.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 12 Kgf/ cm2- External work- exposed on wall
Anganwadi No.108
18.42.2:Boring with 100 mm diameter casing pipe for hand pump/ tube well in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump/tube well is lowered and tested:Beyond 6 m and upto 12 m depth
50.18.9.14.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall
OD361472/2025-2026:Supplying and fixing 0.5HP motor etc as per instruction of Engineer in charge
50.18.9.13.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1392025.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
viewsbd.pdf
Tender Documents • 1.63 MB
BOQ_1392025.xls
BOQ • 0.30 MB
ten.pdf
Tender Documents • 1.21 MB
Download all tender documents and submit your bid