Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.0 LAccepted-AOC | 1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | FARADAYS ELECTRIC WORKS L1 |
|---|---|---|---|---|
| 1.00Supply, erection, and commissioning of 20HP C/F stage pump set in First Booster pump house Kossady and allied works | ||||
| 1.00 | OD313258/2023-2024:Design, Supply , erection, testing, Trial run and commissioning of approved brand new CF pump set with the following specification -
1. Pump - Supply, erection, testing and commissioning of KWA pre-qualified reputed make centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable types base plate with coupling, coupling guard, foundation bolts and nuts etc. complete including providing suitable concrete foundation including cost of material etc. complete. as per CEA regulation 2010 and present code of practice for an operating total head of 77 m, discharge 7.81 Lps including cost of all required protection equipment with an efficiency not less than 70%, Suction head – positive suction, (Total head to be ensured by the contractor)
2. Motor - Supply, erection, testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working on 3 phase 50 Hz Ac supply, working voltage 415V/3300 V(select suitable), 1500rpm. The motor shall confirm to Latest IE standards including providing suitable concrete foundation, including cost of materials etc. complete for 3300 V motors digital motor protection. Relay shall be included in starter as per present IE rules. . Flexible coupling shall be used for coupling of pumps and motors
3. Starter - Supply erection testing and commissioning of suitable rating (Fully automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starter to be used) . Here soft starter to be provided. Starter suitable for the above motor with over voltage and under voltage protection, single phase preventor, overload relay with motor protection relay with main contactor and bye pass contactor as per IE rules and code of practice etc complete
4. Panel board - Supply , erection, testing and commissioning of cubical type wall mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity motor protection MCCB as incomer and and No of suitable capacity MCCB as outgoing providing suitable size Aluminium bus bar to interconnect the above MCCBs and fitted with 3 Nos of indicator lamps,1 no. volt meter with selector switch ,1 no. Ammeter with selector switch for measuring current in each phase etc. complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation.
5. Cabling work - Supply, laying testing and commissioning of suitable size XLPE copper cables for the above pump set from panel board to starter and from starter to motor considering energy conservation for a total length of 10 M.
6. Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe /plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.
7. Capacitor - Supply, erection testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. Capacitor should be connected to external contactor, and the capacitor shall confirm to IS 2834
8.Valves and Pressure gauges – Supply, Erection and commissioning of suitable size best quality heavy duty ISI marked CI double flanged Sluice Valve electrical actuator (capable of operating in Fully, Semiautomatic modes and also in manual mode), Non Return Valve and Pressure Gauges with suitable Pressure rating. Fitting of valves shall include proper RCC support. In case of positive suction pipes set sluice valve should be in suction as well as delivery sides for easy repair works.
9. Suction and delivery pipe connection - Supply and fitting of suitable size best quality MS pipe of shell thickness not less than 10 mm for a total of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc complete and connecting the delivery side of thr pump with the valves and suitable specials to connect the pumping main. If the dia of suction pipe is above 80 mm CI pipes and specials shall be provided. Efficiency of pumpset shall not be less than 70 %. The guarantee period is minimum two years with full replacement of above mentioned units . As per the order no. 9710/ae 15/2021/kwa dtd 8-2-2023. | 1 | no | 4,80,835 ₹4,80,835 Lowest |
| 2.00RWSS To Kossady. Supplying and fitting new panel board and meter board and wiring for new light connection at Second Booster pmp house Kossady. | ||||
| 2.00 | OD309974/2023-2024:Disconnecting power supply and dismantling cable connecctions and dismantling damaged meter board from wall and making and fitting new meter board for 25HP C/F pump set (including cost of metal board , fuse unite, ELCB etc...) | 1 | 1 nos | 12,100 ₹12,100 Lowest |
| 2.00 | OD310006/2023-2024:Disconnecting power supply from panel board dismantling incoming and out going cables from panel board and dismantling damaged panel board from wall and fitting new metal board with indicator, volt meter , Ampere meter , selector switch, main switch and starter etc... | 1 | 1 nos | 43,000 ₹43,000 Lowest |
| 2.00 | OD310040/2023-2024:Dismantling damaged panel board from wall and fitting new panel board on wall and wiring and connecting with cables and trial run etc | 1 | 1 nos | 7,900 ₹7,900 Lowest |
Tender Value
₹5.0 L
EMD Value
₹12,417
Closing Date
25 Feb 2025, 5:00 pmClosed
Assistant Executive Engineer
Assistant Executive Engineer PH Sub-Division,Ponkunnam
Others-KWA-DRW-2023 Urgent works to Mitigate water scarcity - Energy Efficiency Improvement -supply , erection and commisioning of CF pump with discharge 7.81 lps and total head 77m stage pump set in first booster pump house kossady
2025_KWA_737235_1
05/AEE/PHSD/PKM/2024-25
Open Tender
Electrical Works
Item Wise
kossady
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,095
Yes
₹12,417
Yes
24 Sept 2025
17 Feb 2025
27 Feb 2025
17 Feb 2025
25 Feb 2025
17 Feb 2025
Amount
Supply, erection, and commissioning of 20HP C/F stage pump set in First Booster pump house Kossady and allied works
RWSS To Kossady. Supplying and fitting new panel board and meter board and wiring for new light connection at Second Booster pmp house Kossady.
OD309974/2023-2024:Disconnecting power supply and dismantling cable connecctions and dismantling damaged meter board from wall and making and fitting new meter board for 25HP C/F pump set (including cost of metal board , fuse unite, ELCB etc...)
OD310040/2023-2024:Dismantling damaged panel board from wall and fitting new panel board on wall and wiring and connecting with cables and trial run etc
Bidder Name
FARADAYS ELECTRIC WORKS
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .