Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC SCF 15 HUDA COMPLEX 184 NEW IDC 124001 | ROHTAK | HARYANA | 124001 | ₹2.0 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹2.4 Cr+₹41.2 L (20.8%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹2.4 Cr+₹41.2 L (20.8%) | L2 | Rejected-Finance Highest |
| 3 | L3₹3.0 Cr+₹1.0 Cr (52.8%)Rejected-Finance VISHAVKARMA CHOWK NARWANA VISHAVKARMA CHOWK NARWANA 126116 | NARWANA | JIND | HARYANA | 126116 | ₹3.0 Cr+₹1.0 Cr (52.8%) | L3 | Rejected-Finance Highest |
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
16 May 2023, 5:00 pmClosed
RITESH NANDAL
ED - Ambala
Construction of MCH Block and Service Block in the campus of Civil Hospital, Sec.-6, Panchkula. (Pdg. Sub Station and DG Set Only)
2023_HRY_276034_1
2023307DCBE6 485C 40D2 A211 E2BC68079D4E663BAR
Open Tender
Electrical Works
Works
380 days
Panchkula
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹5.0 L
Yes
14 Dec 2023
25 Apr 2023
17 May 2023
25 Apr 2023
16 May 2023
25 Apr 2023
Amount
[20.86]Supply, erection, testing and commissioning of G.O. Switch two poles, with blade, pin 6 insulators operating handle with GI pipe 25 mm class B complete in all respects.
[20.89.10]`Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Diesel Engine b) Alternator c) Battery 24 V. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT`s) h) Metering set 60/5A/110V (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No. j) Battery Charger 24V DC k)Copper bus bar of suitable size l) KWH meter 96 sqmm size m) Starting fuse button and key switch9on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, Dc control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge` 10. 250 KVA
[23.23.6.4]MISCELLANEOUS 6.4. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 600 X 50 X 2 mm
[23.23.7.4]MISCELLANEOUS 7.4. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 600 X 50 X 2 mm
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
[24.2.7.7]LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core
[24.2.8.15]LT CABLE 8.15. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 400 sqmm
[24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm
[24.3.4.1]HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm
[24.5.2.6]MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 145/123 mm outer dia/ inner dia
Supply and erection of lighting arrestor model ISI Marked suitable for 11KV 3 Phase 50 HZ ground neutral system comprising of spare gape type queen gap type in series with non linger resistar element house in Horizontally scale poreclam bushing with line and ground terminal along with mounting clamps conforming to ISS 3070 (Part-I) of 1985 with latest amendment with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.
Supply and Erection MS bucket stand which including cost of 6 nos. buckets of 9 liter capacity with sand filling including cost of welding and painting of complete stand and buckets with one coat of red oxide and two coats of approved paint of red colour with all labour and petty material to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work.
Supply, Erection , testing and commissioning of 11 KV outdoor type HT Metering panel complete with CTs, PTs cubical, and electronics Meter with accuracy class 0.2 as per requirement / approved by UHBVN. Panchkula Electrical Supply consists of following : i) Cubical panel free-standing floor mounting type made of sheet steel 14 G SWG CRCA sheet with channel iron base frame spray-painted with strong synthetic grey channel paint as per size and design approved by UHBVN. PANCHKULA Electrical Supply.Outdoor Type with outer canopy. ii) 3 nos. 11 KV CTs of 0.2 S accuracy (rating as per requirement given by UHBVN Panchkula). iii) 1 no. 11 KV PTs 11000/110 volts 10 VA burden 0.2 accuracy suitable for indoor installation of approved make of UHBVN Panchkula Electrical Supply. iv) Digital electronics meter 3 Phase 4 wire 11000 / 110 volts 10 VA burden 0.2 accuracy for recording reading of KWH of make and rating approved by UHBVN Panchkula Electrical Supply with push-button display operating system for different kind of readings. v) Foundation of Suitable Size 300mm above ground level made of CC having the suitable size to hold the metering panel vi) Outer housing fab by 2mm thick CRCA sheet to cover the HT Metering Panel from rainwater alongwith agnle iron frame. vii) The cubical panel will be complete in all respect including interconnections, internal wiring with PVC copper cable its testing/approval of all items by UHBVN Panchkula Electrical Supply with a guarantee of one year from the date of commissioning including the cost of all labour and material required to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work.
Supply , Erection , testing and comissioning of Stey Set for GO Switch complete in all respect i/cost of Disc insulator etc. upto the entire satisfaction of Engineer -in Charge of work.
Supply, Erection, testing and commissioning of GI Fancing 7.5 Feet High From Finish Floor Level supported with GI Angle/ Channel complete in all repect upto the entire satisfaction of Engineer -in Charge of work.
Supply, Installation, Testing and Commissioning of 11kV Package Substation totally factory assembled, suitable for Outdoor installation with natural cooling with Non - extensible RMU consisting of 2 Nos. feeder with manual operated fixed type load break switch and 1 No. feeder with motorized operated fixed-type VCB 630A, 1 No. 11kV/433V, 1000kVA Oil/Dry Cooled Transformer, 1 set of LT device, FRTU for data integration, all in a common GI enclosure, factory built ready for connection type, internal GI earthling provided complete with other associated equipment etc. and including foundation as per required size and load to complete as required conforming to IEC 62271-202 for Internal Arc Compliance (IAC AB 21kA/1-sec) and relevant IS specifications, as per details given below- Make ABB / Schneider / LandT / Siemens. The 11kV Outdoor Unitized Sub-Station shall be consisting of following:- A) HT Switchgear 11kV, 21kA for 3 sec. Non-Extensible Compact switchgear (Type 2 LBS plus 1 VCB) consisting of 2Nos. Fixed manual Operated 630A Load Break Isolator plus 1 No. Fixed manual operated 630A fixed- type Vacuum Circuit Breaker in SF6 insulated gas-refillable non-magnetic stainless steel enclosure, and Line Metering arrangement along with below mentioned items. Interconnection between HT switchgear and transformer shall be using Al. unarmorured XLPE Cable. i) Each Fixed-Type VCB Feeder consists of following: Manual spring charging arrangement with integrated spring-charging drive and handle and close and open push buttons, ON / OFF indication Self powered O/C and E/F relay with single protection core cast resin type CT with 2.5VA,CL-5P10. Manual operated 630A vacuum-interrupter scheme with built-in series disconnector-cum earth switch having full making capacity. Mechanical position indicator. Switch ON/OFF/EARTHED. Aux. contacts for indication to BMS. Live Cable Indication with SCADA contact Cable compartment cover interlocked with earth switch. Site-replaceable Cable termination bushings suitable for 3 no. 1CX300mm2 XLPE cable. Cable termination cover boots (Push on type) ii) Each Load Break Switch consists of : Manual operated 630A load breaker switch with built-in earth switch having full making capacity. Mechanical position indicator. Switch ON/OFF/EARTHED. Aux. contacts for indication to BMS. Live Cable Indication with SCADA contact Cable compartment cover interlocked with earth switch. Site-replaceable Cable termination bushings suitable for 3 no. 1CX300mm2 XLPE cable. Cable termination cover boots (Push on type) iii) BUS Metering Module arrangement containing : metering class CTs (Acc.Cl.1.0) of suitable ratio, metering class PTs (Acc.Cl.1.0) of suitable ratio, Static Under Voltage Relay Multifunction Meter (Acc.Cl.1.0) for measurement of various parameters such as kV, kVA, kW, kWh, pF, Hz etc of the Transformer feeder only. The meter shall be communicable on ModBus via RS- 485 port. iv) Wiring/Accessories for BMS integration inclusive: Various NO/NC aux. contacts with associated wiring upto suitable TB strip for further take-off to BMS Integration unit Various Aux. Relays to receive remote command, wired upto suitable TB strip for further take-off to SCADA Integration unit Suitable isolation MCB and terminals to receive 24VDC aux. supply from Aux. Supply Unit v) Interconnection between HT Switchgear/Metering-Box and primary of transformer shall be done through 1C x 3R x 150 sq.mm Al. Unarmoured XLPE cable B) 01 No. TRANSFORMER with associated HT/LT link arrangement, Neutral/Body earthing connections, associated fixed-mounting structure with safety interlocked door access having following rating 1000KVA 11KV/433V DYn11 Oil filled hermatically sealed transformer with corrugated wall,without conservator type of design and Top Bushings for HT and LT with Off load tap switch of rating plus 5% to -5% @2.5%. Temp Rise - Oil/Winding 45/50 Deg cel. Losses and Impedance as per IS-1180, Energy Efficiency Level 02. Oil and Winding Temperature Indicator with LCD display and RS-485 port for ModBus communication via BMS integration unit. Various NO/NC aux. contacts and associated wiring upto suitable TB strip for further take-off to SCADA Integration unit C) LT Switchgear 433V LT switchgear with 1000A AL busbars. Interconnection between Transformer and LT Switchgear shall be using AL Busbar. Incomer: 1 No’s 800A, 4P, 50KA Fixed, Manual operated Fixed type MCCB with Microprocessor Based protection release with O/C and S/C protection.( Make: ABB/Schneider/Siemens) and 1 No’s 400A, 4P, 36KA MCCB with Microprocessor Based protection release with O/C and S/C protection.( Make: ABB/Schneider/Siemens) Multifunction Meter (Acc.Cl.1.0) for measurement of various parameters such as kV, kVA, kW, kWh, pF, Hz etc of the Transformer mains, the meter shall be communicable on ModBus via RS-485 port. Various Aux. Relays to receive remote command, wired upto suitable TB strip for further take-off to SCADA Integration unit (refer below) Suitable isolation MCB and terminals to receive 24VDC aux. supply from Aux. Supply Unit D) BMS Integration Scheme Field Remote Terminal Unit shall be provided and installed at a suitable location inside the Compact Substation to receive following feedbacks: (Make:- as per CSS manufacturer recommendation) HT Side - Isolator ON/OFF, VCB ON/OFF, VCB Trip on Fault, Line-Earth On, Line-Earth Off, Incoming Feeder Live, Gas-Pressure Low, MFM Data (ModBus-RTU) Transformer - Door Open/BrEach, OTI/WTI Data (ModBus-RTU) LT Side - ACB ON/OFF/Trip-on-Fault, Draw-Out, MFM Data (ModBus-RTU) Others - BMS connection in Local/Remote, AC Supply Fail Following commands can be executed from BMS (when connection is on Remote) HT - VCB ON/OFF, LT - ACB ON/OFF LED Indication - communication link healthy, System on Local/Remote Other wiring and accessories complete inclusive Local/Remote Switch Isolation MCBs and junction TBs to interface FRTU with CSS Light Interface Unit, Patch cords etc. to interface FRTU with external armoured Fibre Optic cable 24VDC, 30AH Battery plus Charging arrangement with dual charging input (i.e. facility to receive 230VAC i/p from either of the two Transformers with suitable auto-changeover scheme). The batteries shall have sufficient capacity to provide atleast 4-hours of aux. supply to the connected HT/LT Switchgear and FRTU Unit for BMS integration purposes. E) Outdoor Enclosure Outdoor type enclosure having modular construction of Galvanised Sheet Steel in design for natural heat disipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT and LT switchgear compartment and IP23 degree of protection for Transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint ( colour RAL 7032 ). Each compartment will be provided with the door and pad locking arrangement. The enclosure design shall be suitably type-tested for Internal Arc compliance (IAC AB 21kA/1-sec as per IEC 62271-202) The Compartment illumination lamp with door operated switch shall be provided for Each compartment. F) Interconnection and Earthing Interconnection Between HT switchgear and Transformer using Al. Armoured XLPE Single core cable and Interconnection between Transformer and LT switchgear using Busbars. Internal earthing connections by 50 x 6mm Cu strips to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply, Installation, Testing and Commissioning of 11kV Package Substation totally factory assembled, suitable for Outdoor installation with natural cooling with Non - extensible RMU consisting of 2 Nos. feeder with manual operated fixed type load break switch and 1 No. feeder with manual operated fixed-type VCB 630A, 1 No. 11kV/433V, 1600kVA Oil Cooled Transformer, 1 set of LT device, FRTU for data integration, all in a common GI enclosure, factory built ready for connection type, internal GI earthling provided complete with other associated equipment etc. and including foundation as per required size and load complete as required conforming to IEC 62271-202 for Internal Arc Compliance (IAC AB 21kA/1-sec) and relevant IS specifications, as per details given below- Make ABB / Schneider / LandT / Siemens The 11kV Outdoor Unitized Sub-Station shall be consisting of following A) HT Switchgear 11kV, 21kA for 3 sec. Non-Extensible Compact switchgear (Type 2 LBS plus 1 VCB) consisting of 2Nos. Fixed Operated 630A Load Break Isolator plus 1 No. Fixed operated 630A fixed- type Vacuum Circuit Breaker in SF6 insulated gas-refillable non-magnetic stainless-steel enclosure, and Line Metering arrangement along with below mentioned items. Interconnection between HT switchgear and transformer shall be using Al. unarmorured XLPE Cable. i) Each Fixed-Type VCB Feeder consists of following: Manual spring charging arrangement with integrated spring-charging drive and handle and close and open push buttons, ON / OFF indication Self powered O/C and E/F relay with single protection core cast resin type CT with 2.5VA,CL-5P10. Manual operated 630A vacuum-interrupter scheme with built-in series disconnector-cum earth switch having full making capacity. Mechanical position indicator. Switch ON/OFF/EARTHED. Aux. contacts for indication to BMS. Live Cable Indication with SCADA contact Cable compartment cover interlocked with earth switch. Site-replaceable Cable termination bushings suitable for 3 no. 1CX300mm2 XLPE cable. Cable termination cover boots (Push on type) ii) Each Load Break Switch consists of : Manual operated 630A load breaker switch with built-in earth switch having full making capacity. Mechanical position indicator. Switch ON/OFF/EARTHED. Aux. contacts for indication to BMS. Live Cable Indication with SCADA contact Cable compartment cover interlocked with earth switch. Site-replaceable Cable termination bushings suitable for 3 no. 1CX300mm2 XLPE cable. Cable termination cover boots (Push on type) iii) BUS Metering Module arrangement containing: metering class CTs (Acc.Cl.1.0) of suitable ratio, metering class PTs (Acc.Cl.1.0) of suitable ratio, Static Under Voltage Relay Multifunction Meter (Acc.Cl.1.0) for measurement of various parameters such as kV, kVA, kW, kWh, pF, Hz etc of the Transformer feeder only. The meter shall be communicable on ModBus via RS- 485 port. iv) Wiring/Accessories for BMS integration inclusive.: Various NO/NC aux. contacts with associated wiring upto suitable TB strip for further take-off to BMS Integration unit Various Aux. Relays to receive remote command, wired upto suitable TB strip for further take-off to SCADA Integration unit Suitable isolation MCB and terminals to receive 24VDC aux. supply from Aux. Supply Unit v) Interconnection between HT Switchgear/Metering-Box and primary of transformer shall be done through 1C x 3R x 150 sq.mm Al. Unarmoured XLPE cable B) 01 No. TRANSFORMER with associated HT/LT link arrangement, Neutral/Body earthing connections, associated fixed-mounting structure with safety interlocked door access having following rating 1600KVA 11KV/433V DYn11 Oil filled hermatically sealed transformer with corrugated wall,without conservator type of design and Top Bushings for HT and LT with Off load tap switch of rating plus 5% to -5% @2.5%. Temp Rise - Oil/Winding 45/50 Deg cel. Losses and Impedance as per IS-1180, Energy Efficiency Level 02. Oil and Winding Temperature Indicator with LCD display and RS-485 port for ModBus communication via BMS integration unit. Various NO/NC aux. contacts and associated wiring upto suitable TB strip for further take-off to SCADA Integration unit C) LT Switchgear 433V LT switchgear with 1600A AL busbars. Interconnection between Transformer and LT Switchgear shall be using AL Busbar. Incomer: 1 No’s 2000A, 4P, 50KA Motorized, Electrically operated drawout type Air Circuit Breaker with Microprocessor Based protection release with O/C,E/F and S/C protection.( Make: ABB/Schneider/Siemens) Multifunction Meter (Acc.Cl.1.0) for measurement of various parameters such as kV, kVA, kW, kWh, pF, Hz etc of the Transformer mains, the meter shall be communicable on ModBus via RS-485 port. Various Aux. Relays to receive remote command, wired upto suitable TB strip for further take-off to SCADA Integration unit (refer below) Suitable isolation MCB and terminals to receive 24VDC aux. supply from Aux. Supply Unit D) BMS Integration Scheme Field Remote Terminal Unit shall be provided and installed at a suitable location inside the Compact Substation to receive following feedbacks: (Make:- as per CSS manufacturer recommendation) HT Side - Isolator ON/OFF, VCB ON/OFF, VCB Trip on Fault, Line-Earth On, Line-Earth Off, Incoming Feeder Live, Gas-Pressure Low, MFM Data (ModBus-RTU) Transformer - Door Open/BrEach, OTI/WTI Data (ModBus-RTU) LT Side - ACB ON/OFF/Trip-on-Fault, Draw-Out, MFM Data (ModBus-RTU) Others - BMS connection in Local/Remote, AC Supply Fail Following commands can be executed from BMS (when connection is on Remote) HT - VCB ON/OFF, LT - ACB ON/OFF LED Indication - communication link healthy, System on Local/Remote Other wiring and accessories complete inclusive. Local/Remote Switch Isolation MCBs and junction TBs to interface FRTU with CSS Light Interface Unit, Patch cords etc. to interface FRTU with external armoured Fibre Optic cable 24VDC, 30AH Battery plus Charging arrangement with dual charging input (i.e. facility to receive 230VAC i/p from either of the two Transformers with suitable auto-changeover scheme). The batteries shall have sufficient capacity to provide atleast 4-hours of aux. supply to the connected HT/LT Switchgear and FRTU Unit for BMS integration purposes. E) Outdoor Enclosure Outdoor type enclosure having modular construction of Galvanised Sheet Steel in design for natural heat disipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT and LT switchgear compartment and IP23 degree of protection for Transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint ( colour RAL 7032 ). Each compartment will be provided with the door and pad locking arrangement. The enclosure design shall be suitably type-tested for Internal Arc compliance (IAC AB 21kA/1-sec as per IEC 62271-202) The Compartment illumination lamp with door operated switch shall be provided for Each compartment. F) Interconnection and Earthing Interconnection Between HT switchgear and Transformer using Al. Armoured XLPE Single core cable and Interconnection between Transformer and LT switchgear using Busbars. Internal earthing connections by 50 x 6mm Cu strips.
Supply and Erection of PVC insulated aluminium armoured HT cable 95 Sqmm x 3 Core 1100 Volts grade to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and Erection of PVC insulated aluminium armoured LT cable 400 Sqmm x 3.5 Core 1100 Volts grade to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work.
Supply and Erection of prestressed cement concrete pole 11 Mtr. long 152 mm x 203 mm at top and 152 mm x 368 mm at the bottom with working load of 360 Kg. burried 2.20 m in ground with all satisfication of EIC of work. Make as per approved list.
Supply and erection of MS channel 100mm x 50mm x 6mm / MS Flat 50mm x 50mm x 6mm / MS Angle iron 50mm x 50mm x 6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge.
Supply and erection of 65mm GI Pipe complete in all respect upto the entire satisfaction of Engineer-in-charge.
M/s JSB Enterprises
LOHAN ELECTRICAL WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .