Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹95,530Accepted-Finance | L1 | Accepted-Finance Accepted for L1 | |
| 2 | L2₹1.1 L+₹17,795 (18.6%)Rejected-Finance | L2 | Rejected-Finance Higher from L1 | |
| 3 | L3₹1.2 L+₹27,715 (29.0%)Rejected-Finance VILL JHANDUTTA SOAM P O TEH JHANDUTTA DISTT BILASPUR H P | BILASPUR | HIMACHAL PRADESH | 174001 | L3 | Rejected-Finance Higher from L1 | |
| 4 | L4₹1.3 L+₹39,380 (41.2%)Rejected-Finance | L4 | Rejected-Finance Higher from L1 | |
| 5 | L5₹1.4 L+₹42,290 (44.3%)Rejected-Finance R O VILL GATROL PO DABLA TEH GHUMARWIN BILASPUR 174021 | BILASPUR | HIMACHAL PRADESH | 174021 | L5 | Rejected-Finance Higher from L1 |
Tender Value
₹1.3 L
EMD Value
₹2,700
Closing Date
5 Sept 2024, 10:30 amClosed
CEO HPAFMS Bilaspur HP
Directorate of Fisheries Matasya Bhawan Bilaspur HP
Repair and maintenance of electrical work in FO Office building and complex at fisheries Complex Dehra Distt Kangra HP
2024_HAFMS_92125_1
2024_HPAFMS_1825_1
Open Tender
Civil Works
Item Rate
30 days
Dehra Distt. Kangra HP
Please refer Tender documents.
5 documents required · 5 mandatory
₹350
CEO HPAFMS Bilaspur
₹2,700
12 Sept 2024
22 Aug 2024
5 Sept 2024
22 Aug 2024
5 Sept 2024
22 Aug 2024
Amount
Repair and maintenance of electrical work in FO Office building and complex at fisheries Complex Dehra , Distt Kangra (HP)
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required Group-C within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Supplying and fixing G.I. Modular box 3 Module with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connections etc. as required.within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Supplying and fixing G.I. Modular box of size 3 Module with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make: Legrand(Myrius),L&T(entice),Anchor(Roma Plus). 5 amp switch within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make: Legrand(Myrius),L&T(entice),Anchor(Roma Plus). 5amp Socket within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make: Legrand(Myrius),L&T(entice),Anchor(Roma Plus). Bell Push Modular within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x1.5 Sq. mm + 1X1.5 sq.mm within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x4 Sq. mm + 1X4 sq.mm within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 4x4 Sq. mm.+ 2X4 sq.mm within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x10Sq. mm.+ 1X6 sq.mm within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Providing, installation testing and commissioning of ceiling fan with regulator including wiring the down rods of standard length (up to 30cm) and 16/0.20mm twin twisted flexible cotten braided copper cable including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc as required including carriage of material within all leads and lifts. ( Usha technics,Crompten,Havells H S Velocity make or its equivalent. ) or as approved by the Engineer-in-Charge.1200 mm sweep within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Providing and installation exhaust fan of300mm (Metal body) size in the existing opening,including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: Make:- Usha,Bajaj,Crompton or its equivalent within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Supplying and Fixing LED Battan 36 watt High quility aluminium extruded with decorative end caps of superior quality ( Wipro Make ) as per item code LL22-511-XXX-65-G1 as required. Complete in all respect and as approved by the Engineer-in -Charge.Make-Wipro,Jaquar,Philips or its equivalent. within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:- within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Supplying and fixing bakelite batten/angle holder including connections etc. as required:- within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Supplying and fixing 5 amps to 32 amps , 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.)Make L&T, Hager,ABB or its equivalent as per best satisfaction of Engineer-in -charge. Single pole within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Supplying and erection of 40/50/63 amps, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of pole Double pole in the existing MCB DB complete with connections etc. as required:-Make L&T, Hager,ABB or its equivalent within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar,din bar,interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator).Make L&T ,Legrand, Hager or its equivalent as approved by Engineer-In-Charge MCBDB 12 WAY within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Providing and installation of LED Street light 30W with bracket power coated pressure die cast aluminium high power led with heat resistant toughened glass with lens ,electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. as required.:Make ,wipro(LR26-371-XXX-65-XX),Panasonioc Philips or its equivalent as a pproved by Engineer-in -charge.( Five year warranty) within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Supplying and fixing electrical switch board, having 3 No. of 5 amp. switches and socket on suitable size of metal box of 12 modules on surface or in recess with suitable size phenolic laminated sheet cover in the front i/c providing and fixing 3 No. 5 pin 5/6 amp socket outlet and 5/6 amp modular type switch, connection, painting etc.as req.(For Computer board) within all leads and lifts as per the direction of the Engineer-in-charge and other incidentals
Vikas soni
AVNEESH SINGH
RAHUL GAUTAM
Ravinder Nath
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .