Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.4 L+₹2.8 L (8.33%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹37.3 L+₹3.7 L (11.1%)Rejected-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹38.8 L+₹5.2 L (15.5%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹36.9 L
EMD Value
₹73,880
Closing Date
18 Dec 2023, 6:00 pmClosed
GE (AF) Chiloda
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICTION SERVICES AND WATER SUPPLY INSTALLATIONS AND ALLIED WORKS AT SECTOR-09 GANDHINAGAR AND COMN FLT AHMEDABAD
2023_MES_628616_1
8979/23-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GANDHINAGAR
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹73,880
Yes
15 Feb 2024
21 Nov 2023
20 Dec 2023
21 Nov 2023
18 Dec 2023
5 Dec 2023
21 Nov 2023 - 4 Dec 2023
Amount
Taking down carefully copper/ aluminum point wiring (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder , regulators, sockets light fittings etc , removing material to store for keeping in safe custody or for taking credit , and making good disturbed surface of walls, floors, etc complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm single core PVC insulated unsheathed multi stranded copper conductor FRLS cable 1100V grade drawn through and incl PVC casing in capping /conduit with accessories like bends tees, junction boxes etc fixed recessed in wall or ceiling etc including 1.5 Sqmm single core PVC insulated but unsheathed multistrandard copper conductor FRLS cable 1100V grade as earth continuity wire incl sunken type pressed steel terminal boxes of size with 3mm thick bakelite steel white/coloured top cover for :-
(a) One light point controlled by one switch complete all as specified and directed.
(b) One fan point controlled by one switch complete all as specified and directed.
(c) One 3 pin socket out let 5 Amps on the independent board complete all as specified and directed.
(d) One 3 Pin socket out let 5 Amps on the same board complete all as specified and directed.
(e) One bell point controlled by one switch complete all as specified and directed.
All as per item No. 02 here in before above but with cable of size 2.5 Sq mm PVC insulated on independent board for power plug 15 Amps.
S&F in repair switch piano type 230 volts, 5 Amps, single pole complete all as specified and directed.
S&F in repair Socket out let 2 in 1, 3 pin, 5 Amps flush type 230 volts complete all as specified and directed.
S&F in repair switch socket combination (Box type) universal 2 in 1, 6 pin, 5 and 15 Amps flush type complete all as specified and directed.
S&F in repair switch socket combination (Box type) universal 2 in 1, 3 pin, 5 Amps flush type complete all as specified and directed.
S&F in repair bell push 5 Amps flush type complete all as specified and directed.
S&F in repair Ding dong bell AC 230V complete all as specified and directed.
S&F in repair coard less bell of different music AC 230V complete all as specified and directed.
S&F in repair ceiling rose 3 terminal/ poly carbonate, isolated body complete all as specified and directed.
S&F in repair Lamp holder, insulated body with back plate for battern fitting complete all as specified and directed.
S&F in repair 3 pin plug top 6A, 240 V complete all as specified and directed.
S&F in repair 3 pin plug top 16A, 240 V complete all as specified and directed.
S&F in repair Modular switch one way 6A, 1 Module, complete all as specified and directed.
S&F in repair Modular switch one way 16A, 1 Module, complete all as specified and directed.
S&F in repair Modular bell push 6A, 1 Module, complete all as specified and directed.
S&F in repair Modular socket 6/10A-2/3 pin combined 2 Module complete all as specified and directed.
S&F in repair Modular socket 16/15A-2/3 pin combined 2 Module complete all as specified and directed.
S&F in repair Modular Fan Regulator, 120W, 2 module complete all as specified and directed.
S&F in repair white cover plate with frame, 1 module complete all as specified and directed.
S&F in repair white cover plate with frame, 2 module complete all as specified and directed.
S&F in repair white cover plate with frame, 3 module complete all as specified and directed.
S&F in repair white cover plate with frame, 4 module complete all as specified and directed.
S&F in repair white cover plate with frame, 6 module complete all as specified and directed.
S&F in repair white cover plate with frame, 8 module complete all as specified and directed.
S&F in repair Modular metal flush box, 3 Module complete all as specified and directed.
S&F in repair Modular metal flush box, 4 Module complete all as specified and directed.
S&F in repair Modular metal flush box, 6 Module complete all as specified and directed.
S&F in repair Modular switch socket combination (Box type) 6A, 5 pin 3 Module complete all as specified and directed.
S&F in repair Modular switch socket combination (Box type) 16A, 6 pin 3 Module complete all as specified and directed.
M&L in repair for Sub main wiring complete with two run of 6 Sqmm single core, PVC insulated but unsheathed, multistranded copper conductor FRLS 1100 Volts grade cable drawn through in and including non metallic, rigid, PVC heavy duty surface conduit/casing capping (ISI marked) with wall thickness not less than 1.8mm complete with all accessories like bends, tees, junction boxes fixed on wall, ceiling and including sunken type pressed steel terminal boxes with 3mm thick bakelite white/coloured (as approved) top cover including 6 Sqmm single core PVC insulated but unsheathed multistandard copper conductor FRLS 1100 Volts grade cable as earth continuity wire and connected to earth dolly complete all as specified and directed. Note :- Two run of 6 Sqmm cable incl one run of earth wire and PVC conduit and its accessories shall be measured and paid as one length.
M&L in repair to replacement of sub main wiring complete with PVC insulated cable of single core 04 Sq mm (FRLS) 1100 volts grade with multi stranded copper conductor for drawn through and including PVC casing -capping with accessories incl 2.5 Sq mm unsheathed multi stranded copper conductor as on earth wire complete all as specified and directed. Note :- Two runs of single core cable with one run of earth continuity cable including PVC casing -capping and its accessories will be measured and paid as one unit
S&F in repair PVC insulated insheathed multi stranded copper conductor single core of capacity 1.5 sq mm FRLS cable complete all as specified and directed.
S&F in repair PVC insulated insheathed multi stranded copper conductor single core of capacity 2.5 sq mm FRLS cable complete all as specified and directed.
S&F in repair casing capping patti of size upto 25 mm suitable for 3 core/1.5 Sqmm/2.5 Sqmm wire including Tea, junction, etc as required at site and as directed.
Taking down old unserviceable sheet metal enclosure and Supply and fixing sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links ( without MCB's) 4 ways TPN complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links ( without MCB's) 12 ways SPN complete all as directed by Engineer-in-Charge.
All as per item No. 38 here in before above but 8 way.
All as per item No. 38 here in before above but 4 way.
All as per item No. 38 here in before above but 2 way single door.
Taking down old unserviceable sheet metal enclosure and Supply and fixing factory made single pole and neutral sheet metal enclosure with a two Pin Socket plug and socket with one single pole MCB 240 Volts, 20 Amps, capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB, TPN 240 volts, 63 Amps capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB, TPN 240 volts, 40 Amps capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB, SPN 240 volts, 40 Amps capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB, SPN 240 volts, 5-32 Amps capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB, single pole 240 volts capacity 5 Amps to 32 Amps current rating, 10KA breaking capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair blanking plate any size complete all as specified and directed by Engineer-in-Charge.
S&F in repair residual current circuit breaker (RCCB)/ELCB of DP of capacity 63 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in repair residual current circuit breaker (RCCB)/ELCB of DP of capacity 32 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in repair isoator 4 pole 100 Amps 415 volts 50 Hz complete all as specified and directed.
S&F in repair MCB TP 63 Amps 415 volts 50 Hz complete all as specified and directed.
S&F in repair for LED tube light fittings 1x9Watts, 230 volts 2 feet length, surface and wall mounted LED type and including connection up with twin core twisted flexible copper conductior cable of size 1.5 sqmm complete all as specified and directed.
S&F in repair for LED tube light fittings 1x22Watts, 230 volts surface and wall mounted LED type use and throw type and including connection up with twin core twisted flexible copper conductior cable of size 1.5 sqmm complete all as specified and directed.
S&F in repair for LED batten for T8 LED Retro lamp 20Watts, single side connection 230 volts surface and wall mounted LED type complete with all accessories internally pre wired and including connection up with twin core twisted flexible copper conductior cable of size 1.5 sqmm complete all as specified and directed.
S&F in repair for LED (Tube) T8 LED Retro lamp 20Watts, single side connection 230 volts complete all as specified and directed.
SS&F in repair 36 W LED 2'x2' size new generation, aesthetically designed ultra modern surface mounting luminaire with high brightness SMD LED as light source, suitable Armstrong/Grid ceiling complete with separate electronic driver complete all as specified and directed.
SS&F in repair new generation, IP-65, energy saving, long life aesthetically designed aluminium landscape luminaire for diffuser lighting with high power LED bollard lights 8/9W including fittings and all connection complete all as specified and directed.
SS&F in repair flame proof LED light in hanger, well glass fitting wall/ surface mounted highbay type light with IP 66 protection of capacity 100 Watt complete all as specified. Note: Quoted rate to be included of required T&P for fixing/ repair of light in hanger.
SS&F in repair inverted pyramid tripod type LED bollard lights with soft 360 degree light distribution including fittings and all connection complete all as specified and directed.
S&F in repair recess mounted circular LED slim fit low profile down lighter of capacity 6 watt with all connection complete all as specified and directed.
S&F in repair recess mounted 6 W LED new innova neo swivel spotlight round shaped downlighter low ceiling height cool white Ecco light with all connection complete all as specified and directed.
S&F in repair recess/ surface mounted 15 W LED slim compact aluminium die cast edge lit Octane LED panel round shaped downlighter low ceiling height Ecco light with driver and all connection complete all as specified and directed.
S&F in repair energy saving IP 65 flood light luminaire 120 watt with high power LED as light source complete all as specified and directed.
S&F in repair energy saving IP 65 flood light luminaire 100 watt with high power LED as light source complete all as specified and directed.
S&F in repair energy saving IP 65 flood light luminaire 50 watt with high power LED as light source complete all as specified and directed.
S&F in repair IP-65 15 Watts Post Top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed.
S&F in repair IP-65 70 Watts Post Top,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed.
S&F in repair LED IP-65 35 Watts building security light,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution alongwith iron bracket to be fixed on wall complete all as specified and directed.
S&F in repair tube rod of cap 36 watt suitable for existing fittings complete all as specified and directed.
S&F in repair tube rod of cap 28 watt , T-5 type , 230 volts complete all as specified and directed.
S&F in repair bulb retrofit type 05 watt LED bulb minimum lumens 900, suitable for 180 volt to 280 volt complete all as specified and directed.
S&F in repair bulb retrofit type 15 watt LED bulb minimum lumens 900, suitable for 180 volt to 280 volt complete all as specified and directed.
S&F in repair bulb retrofit type 20 watt LED bulb minimum lumens 600, suitable for 180 volt to 280 volt complete all as specified and directed.
S&F in repair electronic ballast suitable for 1 x 28 watts complete all as specified and directed.
S&F in repair electronic ballast suitable for 1 x 36 watts complete all as specified and directed.
Taking down ceiling fan/cabin fan and dismantling fan blade, dismantling electric connection, removing capacitor, checking of bearings/bushes, cleaning the fan blades with clear water, scrapping the fan blades, placing the bearing, bush, capacitor and painting two coat of synthetic enamel paint incl filling of cavities (capacitor, twin core, flexible cable will be paid under relevant items) reassembling the ceiling fan complete after greasing, oiling, testing the same & making the fan serviceable of any sweep and re-hanging and connecting up to the ceiling rose complete all as specified and directed.
All as per iterm No 77 here in before above, but for exhaust fan 300/380/450mm sweep, any type.
All as per iterm No 77 here in before above, but for wall fan 250/400mm sweep, any type.
Re-winding of ceiling fan motor of any type and size including removing old burnt wire copper wire as per existing gauge & insulated paper, varnishing including cleaning/greasing complete all as specified and directed. Note:- Taking down & refixing of ceiling fan for winding, painting, replacement of bearing, bush, capacitor and alike will be measured & paid separately
Rewinding only of exhaust fan with required guage super enameled wire including varnishing, insulation, taping complete of up to 450mm sweep.
Rewinding only of wall fan with required guage super enameled copper wire including varnishing, insulation, taping complete of 250/350mm sweep.
Supply and fix in repair/replacement exhaust fan of size 250/300 mm sweep silint type in PVC body as required at site complete all as specified and directed by Engr-in-charge.
Supply and fix in repair/replacement wall fan of size 400/450 mm sweep in PVC body as required at site complete all as specified and directed by Engr-in-charge.
S&F in repair capacitor for fan 2.5 MFD complete all as specified and directed.
S&F in repair capacitor for fan 3.15 MFD complete all as specified and directed.
S&F in repair electronic regulator Switch type complete all as specified and directed.
S&F in repair electronic regulator Socket type complete all as specified and directed.
S&F in repair cabin/wall/exhaust fan blade any sweep as per existing complete all as specified and directed.
S&F in repair down rod 12 mm dia made out of high density mild steel 600mm long as per approved sample complete all as specified and directed.
All as per item No 90 here in before above, but 900mm long complete all as specified and directed.
S&F in repair capacitor of cap 50 MFD +- 5%sh, suitable for submersible motor complete all as specified and directed.
S&F in repair for replacement of looping box (enclosures) made of PVC of size 300x200x155mm comprising of 04 Nos aluminium bus bar 100 Amps rating fixed on porcelain insulators, earthing terminal and one MCB SP 6/16 Amp with enclosure complete all as specified . Make:- Sintex or equivalent as approved by GE.
Supply only FR PVC Electrical insulation tape of size18mm x 9.0 mtr x 0.125 complete all as specified and as directed.
S&F in repair MCCB 4 pole, 415V, 100 Amps with breaking capacity 35 KA complete all as specified and directed.
S&F in repair MCCB 4 pole, 415V, 63 Amps with breaking capacity 25 KA complete all as specified and directed.
S&F in repair Thermostat of water heater for 25/50 Ltrs capacity AC 230V complete all as specified and directed. Make:- Theta/Bajaj/Danfoss or equivalent as approved by GE.
S&F in repair Water heater heating element for 25/50 Ltrs capacity 1.5 KW/2.0KW/2.5KW/3KW complete all as specified and directed.
S&F in repair flexible hot water pipe steel cover wire of length not less than 3 fit with washer for hot and cold water for geyser connection complete all as specified and directed.
S&F in repair flexible hot water pipe of length not less than 60 cm with washer for hot and cold water for geyser connection complete all as specified and directed.
S&F in repair Indicator lamp (red, green) including necessary connection in geyser capacity of 25/50 Ltrs complete all as specified and directed by Engr-in-charge. Note:- Rate quoted by tenderer is for each neon lamp.
S&F in repair Geyser Assembly 6 hole/9 hole of water heater for 25 Ltrs capacity AC 230V complete all as specified and directed.
S&F in repair Geyser Assembly 6 hole/9 hole of water heater for 50 Ltrs capacity AC 230V complete all as specified and directed.
S&F in repair Geyser Cover top/bottom of water heater for 25/50 Ltrs capacity AC 230V. Make:- Theta/Bajaj/Danfoss or equivalent as approved by GE complete all as specified and directed by Eng-In-Charge.
S&F in repair Outer Body of water heater for 25 Ltrs capacity AC 230V complete all as specified and directed.
S&F in repair Outer Body of water heater for 50 Ltrs capacity AC 230V complete all as specified and directed.
S&F in repair Lower Body of water heater for 25 Ltrs capacity AC 230V complete all as specified and directed.
S&F in repair Lower Body of water heater for 50 Ltrs capacity AC 230V complete all as specified and directed.
S&F in repair Upper Body of water heater for 25 Ltrs capacity AC 230V complete all as specified and directed.
S&F in repair Upper Body of water heater for 50 Ltrs capacity AC 230V complete all as specified and directed.
S&F in repair acoustic insulation wool of water heater for 25/50 Ltrs capacity AC 230V complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for foundation of pole and laying of UG cable and getting out in any type of soil complete all as specified and directed.
Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting piont complete all as specified and directed.
Returning filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
M&L for cutting of existing steel tubing for alternations or additions of 15 mm dia pipe line complete all as specified and directed by Engr -In-charge.
M&L for cutting of existing steel tubing for alternations or additions of 20 mm dia pipe line complete all as specified and directed by Engr -In-charge.
M&L for cutting of existing steel tubing for alternations or additions of 25 mm dia pipe line complete all as specified and directed by Engr -In-charge.
M&L for cutting of existing steel tubing for alternations or additions of size from 40mm to 80 mm dia pipe line complete all as specified and directed by Engr -In-charge.
Taking up or down from trenches/wall/floor/ceiling, steel tubing and connections, including for re-fixing or removing complete all as specified and directed of the following sizes :-
80 mm bore dia
40 mm bore dia
25 mm bore dia
20 mm bore dia
Supply and laying GI tubing medium grade including GI fittings like sockets, elbows, bends, Tees, unions, short pieces etc. laid in trench complete all as specified and as directed of the following sizes :-
80 mm bore dia
40 mm bore dia
25 mm bore dia
20 mm bore dia
Supply and laying in repair UPVC tubing medium grade including UPVC fittings like sockets, elbows, bends, Tees, unions, short pieces etc. laid in trench complete all as specified and as directed of the following sizes :-
40 mm bore dia
25 mm bore dia
20 mm bore dia
S&F in repair gun metal gate/globe valve heavy duty (ISI marked) with iron wheel head screwed both ends for iron pipe for the following bore of pipe including testing complete all as specified and directed.
15mm dia
20mm dia
25mm dia
40mm dia
M&L for cleaning of UG sump 25,000 gallons by removing sludge/sand/dirt by means of Manual/by sludge removing pump, cleaning the sump with bleaching powder, drying and applying one coat of lime wash internally after washing with sodium hypochlorite solution complete all as specified and directed by Engr-in- Charge. Note:- Date of Cleaning should be marked on sump with suitable stencil.
All as per item No. 123 above here in before but 50,000 gallons capacity sump.
S&F in repair to replacement of sluice valve of 100mm bore class PN-1 type duly ISI marked with iron wheel and head non raising spindle stainless steel confirming to IS 14846 flanged ends including rubber joints & jointing material complete all as required at site.
All as per item No. 125 above here in before but 80 mm dia.
S&F in repair to replacement of Gun metal foot valve 100mm size with all accessary complete all as specified and directed.
S&F in repair of existing old US, single phase preventer and tiimer, 3 phase of type ESP-2, volt 415 complete all as specified and directed.
M&L Construction of 3mm thick MS Sheet cover fixed on 40mmx40mmx6mm thick angle iron frame embedded in PCC coping with locking arrangement and mild steel surface with two coats of red oxide primer etc complete all as specified and directed.
S&F in repair LED bulk head light 10 Watt with IP-65 protection complete all as specified and directed.
M&L for preparation of old painted surface of size upto 100 mm dia iron pipe and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for servicing of pressure pump 1 HP at site including taking down from existing place, checking of NRV, Impeller, pressure switch, rubber diaphram, capacitor and bolt etc and refixing the same position and connecting complete all as specified and directed by Engr-in-Charge.
S&F in repair pressure switch PS-98 range 2.5-9.5 auto suitable to operation on 230V AC supply complete all as specified and directed.
S&F in repair Non return valve suitable size of pressure pump 1HP complete all as specified and directed.
S&F in repair impeller suitable size of pressure pump 1HP complete all as specified and directed.
S&F in repair mechanical seal suitable size of pressure pump 1HP complete all as specified and directed.
S&F in repair capacitor suitable size of pressure pump 1 HP complete all as specified and directed.
S&F in repair 5 way connector suitable size of pressure pump 1 HP complete all as specified and directed.
S&F in repair Non return gun metal valve 15mm brass both side threaded complete all as specified and directed.
Dismantling, cleaning and over hauling centrifugal mono block pump set of the following capacities including rewinding of motor with appropriate super enameled copper wire of existing gauge, replacement of bearing including all connection and testing complete for following capacities :-
(b) 1 HP/2HP
M&L for preparation of old painted surface of mono block pump set of capacity 0.5 to 01 HP and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L to repair in replacement of electric driven motor (mono block) 0.5 HP capacity up to 15.00 meter head single phase 230 V including necessary connection complete with suction/ delivery pipe of 15mm x 15mm bore complete all as specified and directed.
All as per item No. 142 above here in before but above but 1 HP.
Dismantling and repair of centrifugal pump set of 20 HP 42 Mtr head and opening & replacement of following items incl transporting of pump set to work shop all as directed:- 1. Replacement of CI impeller as per existing size. 2. Replacement of EN-8 pump shaft complete with check put key. 3. Replacement of type C-40 pump casing bottom. 4. Replacement of gland packing plate. 5. Replacement of bearing housing CI complete. 6. Replacement of ball bearing Nos 5309. 7. Replacement of planter ring. 8. Replacement of liquid deflector. 9. Replacement of shaft sleeve SS 410. 10. Replacement of set of key. 11. Replacement of lock washer for support foot. 12. Replacement of lock washer for impeller foot. 13. Replacement of grease nipple. 14 .Replacement of oil level sight glass. 15. Replacement of oil seal. 16. Replacement of gasket set. 17. Replacement of plug set. 18. Replacement of fasteners. Assembling of pump set complete and fixing in foundation and connecting with motor coupling and testing on full load complete all as specified and directed by Engr-in-charge
All as per item No 144 above here in before but of capacity 7.5 HP complete.
S&F in repair PVC insulated insheathed multi stranded copper conductor three core flexible type of capacity 2.5 sq mm FRLS cable complete all as specified and directed.
S&F in repair PVC insulated insheathed multi stranded copper conductor three core flexible type of capacity 1.5 sq mm FRLS cable complete all as specified and directed.
S&F in repair of motor starter panel incl replacement of power contactor, timer, wiring and connected accessories as present at site suiable for LT Panel removing the old one and fix serviceable as existing and testing complete all as specified and directed.
M&L for dismentaling and step opening to complete centrifugal motor of cap 20 HP and segrigated all serviceable parts and kept at site for reuse including rewinding with supper enamled wire of suitable gauge complete, and replaceing bushes, bearing check nut, and other required parts and barnishing the same incl painting of motor , making serviceable to the motor complete and servicing, cleaning, greasing, overhauling, re-alingment with lock, key, nut, bolts, washers and reassembling the same with centrifugal pump after testing complete and all as directed by engineer-in-charge. Note :- The contractor will be responsible for maintaining the centrifugal pump in serviceable state for the entire contract period. Since the job involves major overhauling,no additional payment will be made to the contractor if servicing is required more than once.
All as per item No 149 above here in before but of size 15 HP motor .
All as per item No 149 above here in before but of size 7.5 HP motor .
M&L for preparation of old painted surface of centrifugal pump set of capacity 20 HP and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L in repair/ jointing of water Leakge in pipe line of size upto 100 mm dia including removing old rusted line make necessary connection to new pipes complete. Note: Pipe/Tubing required will be paid under relevent itmes.
M&L in repair to submersible pumping set and motor capacity 25 to 30 HP, 440V ,3 Phase discharged 510 LPM at 123 Metre head consisting of following:- Opening of submersible motor and cutting to burnt winding and cleaning to slots by cleaning and repair to damage starter etc, rewinding to submersible motor with suitable size of superior quality copper winding wire insulating materials all as directed by Engineer in charge, Replacement of thrust bearing – 01 No, Replacement of bush – 02 Nos, Re-assembling and transporting to Pump House, lowering pump and testing complete. Dismantling of submersible pump set all as directed and replacement of the following items- (i) Replacement of neck ring – 05 Nos, Replacement of brass bushes– 05 Nos, Replacement of shaft bush- 02 Nos, Replacement of impeller -05 Nos. Note: The contractor will be responsible for maintaining the submersible pump in serviceable state for the entire contract period. Since the job involves major overhauling, no additional payment will be made to the contractor if servicing is required more than once.
All as per Item No 154 above here in before but 5 Hp to 15 Hp submersible/ monoblock pump and consisting of following.
All as per Item No 154 above here in before but 20 HP and consisting of following.
M&L for dismantling of centrifugal pump set 30 HP at 42 Mtr head opening & replacement of following items including transporting of pump set to work shop all as directed. (a) Replacement of CI impeller as per existing size. (b) Replacement of EN-8 pump shaft complete with check put key. (c) Replacement of type C-40 pump casing bottom. (d) Replacement of gland packing plate. (e) Replacement of bearing housing CI complete. (f) Replacement of ball bearing 5309. (g) Replacement of planter ring. (h) Replacement of liquid deflector. (i) Replacement of shaft sleeve SS 410. (j) Replacement of set of key. (k) Replacement of lock washer for support foot. (l) Replacement of lock washer for impeller foot. (m) Replacement of grease nipple. (n) Replacement of oil level sight glass. (o) Replacement of oil seal. (p) Replacement of gas kit set. (q) Replacement of plug set. (r) Replacement of fasteners. (s) Assembling of pump set complete and fixing in foundation and connecting with motor coupling and testing on full load complete all as specified and directed by Engr-in-charge.
M&L calcium hypochlorite 65% to 70% chlorine content in granular form (calcium based granular disinfectant for chlorination of water) in 45 kg packing complete all as specified and directed.
M&L for dismentaling and step opening to complete centrifugal motor of cap 30 HP and segrigated all serviceable parts and kept at site for resue including rewinding with supper enamled wire of suitable gauge complete , and replaceing bushes, bearing check nut, and other required parts and barnishing the same incl painting of motor , making serviceable to the motor complete and servicing, cleaning, greasing, overhauling, re-alingment with lock, key, nut, bolts, washers and reassembling the same with centrifugal pump after testing complete and all as directed by engineer-in-charge. Note: The contractor will be responsible for maintaining the centrifugal pump in serviceable state for the entire contract period. Since the job involves major overhauling, no additional payment will be made to the contractor if servicing is required more than once.
S&F in repair Capacitor suitable for monoblock/ submersible pump of 0.5 Hp to 2 HP complete all as specified and directed.
Lowering & lifting of existing pump set from borewell and repaired pump set with taking out carefully of 18 Nos. column pipe of 80/150 mm size each length of 3 mtr with flange joints repairing/ welding all as required at site to column pipe and including cable proper fixing with pump set and column pipe and making connection with existing starter all as required at site and as directed by Engr-in-charge. Note :- Cost of flange type with jointing material like nut-bolts, gasket sheet etc. shall be included in item rate quoted.
S&F in repairs flat 3 core copper conductor PVC insulated & PVC sheathed cable 1100 Volts grade of size 10 Sqmm including 40 mm dia PVC conduit fixed to wall/ in duct laid in floor/trench etc complete all as specified and directed.
M&L for taking down of old panel and repair in replacement of same with factory made in door type panel made out of 2mm thick CRCA sheet powder coated suitable for up to 30 HP submersible pump embedded on required size brick masonry platform comprising of following:- (a) Star delta starter for 30HP- 01 No (b) MCCB TP 63Amp, 25KA – 01 No (c) Isolator TPN 32Amps – 01 No (d) Amps meter with CT-01 No (e) Volt meter 0-500V- 01 No (f) Single phase preventer – 01 No (g) Indicating lamp – 1 Set (h) Copper bus bar 200 Amp – 1 No Make Havells
M&L for Collection of water sample from borewell & getting then tested from Govt laboratry & furnishing test report, indicating chemical, & bactrological analysis including presrence of floride, TDS, LEAD contents if any complete all as specified and directed by Engr-in-charge.
S&F in repairs MS column pipe 100 mm dia medium grade (heavy duty) flanged type incl necessary fixing MS nut, bolt, washer & gaskets' etc incl groove for cable entry system of 3 mtr in length complete all as specified and directed.
Servicing, repair and testing of fire alarm panel (non comprehensive maintenance) having appx 10 devices & 4 Zone till completion of contract which includes quarterly visit and emergency callout of make honeywell. Note :- (a) Check all connection of control panel. (b) Check correct unobstructed setting of detectors and call points. (c) Test detector and call point in each zone. (d) Test alarm sounders. (e) Correct fuse rating, Secure battey terminal. (f) Cleaning of control Panel. (g) From test 2.1 Check alarm zone/ address/ location reported, stimulate fault isolation in each zone. (h) Contractor will responsible to keep panel in serviceable condition If any dameged electrical, mechanical, electronic part/ element noticed while repair/ Servicing it will be changed in the contract period without any extra cost.
S&F in repair battery 12 Volt, 7.0 Ah rechargeble VRLA type complete all as specified and directed.
S&F in repair hooter cum flasher for fire alarm panel as per existing sample complete all as specified and directed.
S&F in repair smock detector for fire alarm panel as per existing sample complete all as specified and directed.
S&F in repair MCP resettable for fire alarm panel as per existing sample complete all as specified and directed.
S&F in repair PVC insulated insheathed multi stranded copper conductor four core flexible type of capacity 4.0 sq mm FRLS cable complete all as specified and directed.
S&F in replacement of fire alarm panel of existing make and capacity or equivalent as approved by GE complete all as specified and directed.
Comprehensive maintenance and servicing of chlorine dosing equipment self priming, having discharge capacity up to 5 Ltrs/Hour of existing make making the plant fully serviceable at the following locations:- Note:- (i) Spares required for replacement will be inclusive in quoted rate in this item. (ii) The rate quoted by the tenderer includes cost of maint/ Servicing of above said plant in a period of 90 days till the date of completion of work. (iii) Rate inclusive of labour cost replacement of parts during currency of contract as and when directed by Engineer-in-Charge.
(a) Pump house at hanger, Ahmedabad - 02 plant
Note : For item No 1 to 172.01 1. Quoted rate should be included of labour charge contractor has to deploy minimum two electrician on routine basis for day to day internal electric complaint, one plumber for water supply complaint. 2. complaints of day to day internal electrification and water supply should be attended and rectified within 24 hr otherwise a penalty of rupees 500.00 Rs per day per complaint will be recoverd from the contracter.
TECH SERVE SOLUTIONS
Electricals India
Shree Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .