Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹44.3 L+₹1.7 L (4.08%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹44.4 L+₹1.9 L (4.35%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
₹50.0 L
EMD Value
₹99,960
Closing Date
29 Jun 2023, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Repair/maint of DG sets Voltage Stabilizers Cranes services of Incinerators Washing Machine Air Compressor and allied items and Repair / maint of Security Light Gate Lights at MH EME WKSP AC Record MD ACCN FAFA MD ACCN BTR VIJAY LINE under GE(N) Ahme
2023_MES_595932_2
8759 / E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Garrison Engineer North Ahmednagar
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer(North) Ahmednagar
₹99,960
Yes
11 Jul 2023
6 Jun 2023
1 Jul 2023
6 Jun 2023
29 Jun 2023
15 Jun 2023
Amount
Comprehensive Maintenance of D.G sets, periodical servicing including first hand repairs, consisting of normal repair such as tightening of nut bolts, greasing, checking/ replacing of battery terminals, levelling of distilled, water, cleaning of main battery charging alternator where ever exists, replacement of defective/ worn out spares such as diesel filters, rubbers hose pipe , fuel pipe and change of oil and cleaning of radiators etc. Note :- (a) The maintenance cost of D. G set for month shall deemed to comprise of cost of labour employed for the purpose. (b) All spares and oil replaced will be measured & paid under relevant items of scheduled 'A'. (c) Fixing charges for the spares and oil etc, are deemed to be included in quoted rates.
(ii) 160 KVA
(iii) 100 KVA/110 KVA/125 KVA
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
(ix) 200 KVA
Taking down defective self-starter 12/24 Volt of D. G. set of capacity 100 KVA to 320 KVA D. G set installed at various installations & servicing / overhauling including replacing worn out part like solenoid, bearing, carbon brush, rewinding the starter motor winding etc. & refitting the same after repair for smooth functioning in all respect.
Same as in Sl N. 02 but 15 KVA to 63 KVA
M/L for cleaning the fuel tank both internally & Externally by removing all the dust / sediments etc. in cluding writing of tank capacity, Date of cleaning for followings.
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
Supply Diesel fiiter with 'O' Ring suitable for following capacity of D. G. sets as per sample :-
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
Supply Air fitter element suitable for following capacity of D. G. sets as per sample :-
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 11 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
Supply oil fitter element with 'O' Ring suitable following capacity of D. G. sets as per sample :-
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
Supply set of belts suitable for following capacity of D. G. sets as per existing at site :- note : Each set included dynamo belt,Fan belt and water pump belt
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
Supply set of Rubber Hose for water & Air circuit complete suitable for D. G. sets of following Capacities:-
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
Scrapping / cleaing the existing paint completely and painting with two coats of anti corrosion synthetic enamal paint with spray painting colour as to be followed ). D. G. set (Internal & External), fuel tank etc. Note : Coloue code as per existing colour including removing all stricker/rediam fixing new strickre as per existing
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
M & L for removing the fuel injection pump from D. G set capacity 100 to 320 KVA and carry out servicing & calibration from authorised service workshop including replaceement of injectors, Nozzles etc. and refitting the same for smooth and efficient functioning all as directed by Engr-in-Charge.
As per Item No 11 but for 40 to 63 KVA
As per item No. 11 but for 7.5KVA to 25 KVA
M & L for replacement of stater switch of DG set of capacity 63 to 320 KVA complete all as speciifed and directed
M&L for repair to radiator by disconnecting the radiator from engine frame and servicing / cleaning with acid and brazing where required to stop leaking tubes/joints etc. cleaning fins and re-fixing the same for D.G. set given below.
(i) 100 KVA to 320 KVA
(ii) 40 KVA to 63 KVA
(iii) 7.5 KVA to 25 KVA
M & L for repair of turbo charge by replacing repair kit & fixing same on D. G set 40 KVA to 320 KVA
Taking down the defective water pump fram D. G . Set & replace with new one for D. G. set. Of following capacities complete all as all directed by Engr-in-Charge.
100 KVA to 320 KVA
40 KVA to 63 KVA
7.5 KVA to 25 KVA
Supply Egine Oil, 15W-40 complete all as specified and dierected
Supply Coolant for Engine
Supply Electrolyte of suitable spigravity for lead Acid batterries
Supply only distil water for battery
Supply fuel pipe steel braded with Benzo bolt & washer etc. of lenth 30 c. m
Supply fuel pipe steel braded with Benzo bolt & washer etc. of lenth 60 c. m
Supply fuel pipe steel braded with Benzo bolt & washer etc. of lenth 100 c. m
Taking down the defective coupling at Exhaust mainfold end & fix new flexiable coupling stainlen steel as per sample.
Taking down the existing perished/damaged asbestos rope and supply & replace with new asbestos rope 10 m. m thick on the exhaust pipe including covering with
Supply & fix in replacement of automatic voltage requlator 100 to 320 KVA D. G. set complete all as specified and directed.
Supply & fix in replacement of automatic voltage requlator 20 to 63 KVA D. G. set complete all as specified and directed.
Supply battery leads set, PVC insulated multi stranded cooper 70 sq mm of 1.25 meter long each duly fixed with bran clamps
M & L for replacement of brans battery terminal suitable for lead acid, battery 12 v any AH
Supply & fixing in replacement digital ammeter 0 to 300 Amps
Supply & fixing in replacement digital Voltmeter 0 to 500 Amps
Supply & Fixing Engine Oil pressure gauge meter up to 7 kg complete all as specified and directed
Supply & Fixing in replacement of Engine water temp. meter complete all as specified and directed.
Supply and fix in repairs change over switch existing panel, wall or LT pole of any size and any type on load type, triple pole and neutral, 100 Amps, 415 V, 50 Hz front handle operated, including connecting and testing all as directed. MAKE: L&T / Legrands/Seimens
All as per item No above but off load type, 125A side handle operated,including connected accssories complete all as specified and directed MAKE: Indoasian/ HAVELLS / HPL
All as per item No above but off load type, 200A side handle operated, MAKE: L & T/Havells
M & L For welding / brazing of silencer pipe of of DG Set
M & L for replacement of Door Hinges of various capacity of DG Set
M & L for replacement of Door lock of various capacity of DG Set as per existing at site of any capacity of adg set
S & F Contractor MNX 225 2 No + 2 NC ,3 pole power contractor current rating AC 3 :225 Amp,AC1 :300 Amp or as per existing at site of capacity of DG set 100 to 160 KVA
S & F in replacemt of MCCB 250 Amps, three pole,25 KA complete all asspecified and directed by Enge in charge
S & F in replacement of Indicator lamp of colour (red,yellow,green) of dg set panel of any capacvity of dg set including all connecting circuit
Labour only for perodical maintenance, brake down on call repairs of EOT Crane 2 Ton long travel motor , cross travel motor , gear box , control panel etc. installed at armoured static work shop including dismaintling/replacing the unserviceable spair parts at site complete all as specified and directed. Note:- Rate includes greesing, cleaning, oiling etc.
All as per Item No 47 above but 2.5 Tons
All as Per Item No 47 above but 3.5 Ton
All as per Item No 47 above But 10 Tons
Note For Item No 43 to 48 :- (a) Maintenance of cranes required to be done in every month which includes cleaning, greasing, , oiling, which ever required, checking of all electrical connections and standard maintenance as recommended by manufacturer. (b) Spare Parts replaced, Oil, Lubricants (except Grease ) required will be measured and paid separately. (c) Load test carried out in the presence of Engr-in-Charge and users on every month after periodical maintenance. (d) contractor shuld attend day to day complaint of crane regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates.
Supply only spare parts suitable for EOT Crane of capacity of 2.0 ton to 10 Ton.
(a) Wheel with pin shaft
(b) Ball bearing (Bearing No-6207)
(c) MS Gear for wheel
(d) Steel wire rope multi stranded 10mm, Make Usha Martin
(e ) PVC Coated & PVC Insulated copper conductor multistranded of size 10 sqmm 4 core
(f) HRC fuse link 32 amps as per site requirement
(g) Gear box Oil EP -230
(h) Brake Oil
(j) Brake Shoe of 150mm dia
(k) Magnetic Coil
(l) Limit switch 3 phase 415 volt 50 Hz as per site requirement
(m) Four Pole Contactor Ac Three phase 415volt Amps as per Site requirement
(n) Carbon brushes for clutch for microw movement of EOT Crane
(o) Current collector complete as per existing for EOT Crane of different capacity of EOT Crane
M & L for taking down Gearbox assembly of any capacity of Crane for long travel mechanism , short travel mechanism, updown mechanism , refixing the same after over hauling completely by replacing Gear oil C-600, Gasket set , bushing etc all as directed. Note: Gear Oil is paid separately and gasket set , bushing etc include the quoted rates.
Taking down and Material and labour for rewinding of electric motor 2HP/415,3HP/415volt,and 5HP/415 volt by using SE Copper wire same gauge and same turns incl varnishing heating, balancing etc from short travel/ long travel mechanism and refixing the same by replacing bearing, varnishing etc all as directed by Engr-in-Charge.
Taking down and Mateerial for rewinding of electric motor 10HP/415 volt by using SE Copper wire same gauge and same turns incl varnishing heating, balancing etc from short travel/ long travel mechanism and refixing the same by replacing bearing, varnishing etc all as directed by Engr-in-Charge.
Material for repairing to long travel shaft by replacing pedstal bearing 06 Nos, including machining work replacing nut, bolts ,washers all as directed by Engr-in-Charge. Note:- Pedastal Bearing is measured and paid separately.
Material for repair to brake system completely by replacing brake shoe , rotor , brake liner , spring for long travel, short travel, updown mechanism all as directed by engr-in-charge. Note:- Break shoes is measured and Paid Separately
Repairs to guide wheel 4 Nos for long Travels by replacing gun metal filling , reboring and machine work with in tolerance limit all as specified and directed.
Material for periodical maint of oil fired incinerator of Make : HAAT Model GD-3once in three month which includes the following works. (a) Descalling of Gap between greads (b) Descalling of combution Chamber (c) Descalling of arch chamber (d) Descalling of stack arrester. (e) Overhauling burner nozzel blast tube pump, diffuser etc. (f) Cleaning of Diesel tank and fuel lines.
Note:- (i) Rate Includes for painting on Diesel Tank and writing in White Paint Date of Cleaning and capacity. (ii) contractor shuld attend day day complaint of Incenarator regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates. (iii) Parts are measured and Paid separately.
Supply Only following Parts :-
(a) Ignition electrode, Cat Part No-HTT09/83
(b) Ignition Transformer 200-6000Volt, Cat Part No-HTT09/83
(c ) Diffuser plate, Cat Part No-HTT06/83
(d) Solenoid Valve Cat Part No-VAL 0029/5
(e ) Fuel Pump Assembly Cat Part No-HT001/9
(f) Fuel Suction Filter assembly, Cat Part No-HA2/3
(g) Combution Blower Cat No-HTT 11/83
(h) Solenoid coil for combution blower, Cat Part No-VA-0320/9
(j) Sequence Controller, Cat Part No-HTT 22/G3
M & L for periodical maint of washing Machine and Dryer DER-30 and Dryer Thumbler once in three month which includes the following works. (a) Descalling of drying chamber by descalling solution MAC (b) Oiling, Greasing of bearing of moters and shaft (c ) Laying and tighting of panel wiring with proper thinbles/ PVC Clampr (d) Overhauling of washing machine Chamber.
Note:- (i) Rate Includes for writing in White Paint Date of Cleaning and capacity. (ii) contractor shuld attend day day complaint of Machine regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates. (iII) Parts are measured and Paid separately.
Supply Only following Parts :-
(a) V Belt size A-69
(b) HRC Fuse up to 32 Amps
(c) Hose pipe for Drain 1.2 Mtr Length
(d) Water Solinied Valve 1''
(e) Conatctor 3 Phase 63 Amps for starter of main drive moter
(f) Heating Contactor
(g) Electric heater
(h) Idler Shaft
(j) sequence Controler
(k) ignition Transformer
(l) Air Filter Cum Regulator
(m) Single Phase Prevainter
(n) Drying Thumbler timer
(o) Tension Spring
(p) Breaking contactor
M & L for rewinding of 3 Phase electric motor including varnishing of washing machine main drive 3 HP incl taking down and reinstalling at site incl connecting electric point and commissioning complete al as specified.
M & L for periodical maint of Voltage stabilizer/ UPS of capacity upto 125 KVA once in three month which includes the following works. (i) check SVS working in auto mode (ii) Check battery terminals and clean (iii) Check input and output connection (iv) check Battery voltage (v) Cech control card (vi) Check Driver card (vii) Check IGBT (viii) Check charger card
Supply Only following Parts :-
(a) Control card for voltage stabilizer/ups as per existing at site
(b) Driver card for stabilizer/ups as per existing at site
(c) IGBT for stablizer
(d) Charger card
M & L for periodical maint of Air Compressor once in three month which includes the following works. (03 Nos of Air Compressor) (a) Checking the compressed air pipe for leakage. (b) Checking of V belt and repair and replace it (c)Oil, Greasing of bearing of moters and shaft (d) Checking of pressure valve switch for automatic control of compressor. (e) Checking of non return valve of compressor and if damage repair it. (f) Overhauling of compressor moter. (g) Tighting and cheking of panelwiring with proper thimble. (h) Painting of Air compressor with with synthetic enamel paint , one coat after cleaning scrubing the surfaces incl wrirting by paint the capacity , marking of fuel level indicator etc complete as directed by Engineer in charge.
Note:- (i) Rate Includes for writing in White Paint Date of Cleaning and capacity. (ii) contractor shuld attend day day complaint of Machine regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates. (iii) Parts are measured and Paid separately.
Supply Only following Parts :-
(a) V Belt suitable for Air compressor to motermain drive Pully
(b) Compressed Air Pipe of 10mm Dia of Heavy Duty
(c) Head Gas Ket
(d) Piston Ring
(e) Connecting Rod
(f) Oil Seal
S & F DOL Starter of Air Compressor moter Main Drive 3 HP Incl taking down and reinstalling with new starter 415 volt 50 cycle current rating 8 Amps incl connecting to electric point and commissioning etc complete all as directed.
M & L for repair and replacement of AMF Panel for 160 KVA DG Set make : Greaves
Supply Only for replacement of following Parts :-
(a) AMF Controller
(b) Contactor 4 Pole 415 Volt 225 Amp, Make: L&T/Seimens
(c ) Bty Charger 24 Volt 20 Amp
(d) Digital multifunctional meter for freq, Amp, Voltage, KWH
(f) Voltage Monitoring relay
M & L for periodical maint of car washing point once in three month which includes the following works. (03 Nos of car washer motor) (a) Checking the motor in regular basis. b) winding of motor
Note:- (i) contractor shuld attend day day complaint of Machine regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates.(iII) Parts are measured and Paid separately.
Material and labour for replacement of unserviceable battery 12 V, 92 AH with maintenance free battery 12 Volt initially charged. Make - Exide
Material and labour for replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 Volt initially charged. Make - Exide
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 63 Amps , with breaking capacity 16 KA , fixed type and connecting etc complete all as specified and directed by Engineer-in-Charge MAKE: Legrand or its equvalent.in makes mentioned in list of makes in Appendix `C'
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 100 Amps , with breaking capacity 25 KA , fixed type and connecting etc complete all as specified and directed by Engineer-in-Charge MAKE: Legrand or its equvalent.in makes mentioned in list of makes in Appendix `C'
Material and labour for earthing complete with copper earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to copper strip 20 x 3 mm, by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
Supply & fix in replacement of Copper strip 25 mm x 3.15 mm Complete with saddles and fixing screws on including epoxy Insulater for Fitting the strip.including Taking down existing copper strip complete all as specified and directed.
Shifting of DG set of any capacity from one place to another place within cantt area including dismentalling of existing connection carefully and lifting ,transporting with the help of crane and necessary transport and reassembling at new place including,reconnection same including testing with complete connection complete all as specified and directed etc
Supply and fixing in replacement of Solenoid switch as per existing at site for dg set of capacity 63 KVA to 200 KVA with complete manufacture connection and necessary items required etc all as speified and directed .
Supply and fixing in replacement of LLOP as per existing at site for dg set of capacity 63 KVA to 200 KVA with complete manufacture connection and necessary items required etc all as speified and directed .
Supply & install in replacement of GI strip 32 mm x 6 mm buried ground/floor/surface/roof Complete with saddles and fixing screws on including epoxy Insulater for Fitting the strip, including taking down existing GI Strip complete all as specified and directed
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on any type of soil.
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil.
Supply and Lay HDPE pipe 63 mm dia for laying of LT cables etc complete with all accessores all as specified and directed.
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
Dismantling carefully the existing unserviceable LT overhead line ACSR conductor any size from its position by necessary disconnecting of conductor and removing complete all as specified and as directed.
Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing complete all as specified and as directed
Taking out existing unsv UG cable of any sizes including etc complete all as specified and as directed.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- Note:- Manufacture year of cable should be 2023.
(a) 10 Sqmm 2 Core
(b) 10 Sqmm 4 Core
(c) 16 sqmm 4 Core
Supply and replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire, twin core cable flat or circular with size 4sqmm. Note : Rate of 4 mm GI wire included in quoted rate
All as per Item No 109 above but 10 sqmm 2 Core
All as per Item No 109 above but 16 sqmm 2 Core
Material and labour in replacement of 40mm dia GI Pipe light grade ISI Marked with all fittings laid in trenches , fixed to walls / poles with FI Clamps of size 40x5 mm all as directed.
Material and labour in replacement of 50 mm dia GI Pipe light grade ISI Marked with all fittings laid in trenches , fixed to walls / poles with FI Clamps of size 40x5 mm all as directed.
M & L steel tubular poles, complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 Mtrs Long) including taking down existing pole complete all as specified and directed
M & L for PCC(1:3:6) type C-2 using 40mm grade stone aggregates as foundation of pole and similar work all as specified and directed.
M & L for PCC(1:2:4) type C-2 using 40mm grade stone aggregates for coping including painting of Two coats of cement base paint and similar work all as specified and directed by Engr-In-Charge.
Dismantling and taking down carefully the defective Highmast light fittings from high mast pole by mechanically/ manually and removing the unseviceable light fitting from pole and supply and fixing led flood light 200 watt,lumen 20000 with 10 KV surge protection in built and reassembling the same pole , and refixing at its original location , including reconnections with suitable length and size of capper/Aluminium wire as per existing and testing / commissioning complete all as specified and directed. Make: Crompton Cat part No. TFS-507-200-57-60D-SL-GL-NSG or equivalent.
Lifting the Highmast pole 16 mtr height by crane from its own location with opening the nut boltt and washers , greasing the steel wire rope and fixing with pulley and reassembling and refixing at its orginal location, including reconnections and testing commissioning complete for smooth operations all as specified and directed. Note: (i) Rate for Crane and labours is being to be includes in Quoted rates. (ii) Rate of sundry items like grease, cotton waste, nut , bolt and washers are deemed to be quoted rates.
Supply only three pole contactor coil suitable for L&T contactor,240V,50 Hz cat part No CS94980/CS94105 or as per existing on site. Make: L&T
Supply only three pole contactor L&T contactor,32/40 Amps,240V,50 Hz or as per existing on site. Make: L&T
Supply and fixing isolater 32/40 Amps,240 volt, three pole complete all as specified and
M & L for painting of Street light poles (with hydrolic vehicle / ladder) including cross arms, channel, flat iron clamps etc (SWAN NECK) 9 mtr long in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos (Yellow circle and Number in black) and providing 3 Nos of radium with width 50 mm size band / strap with Red, Yellow, Green colour 300 mm apart from plinth block around the pole etc complete as all as specified and directed in Engr-in- Charge. Note:- Hydrolic Vehicle / Ladder for painting is responsibility of contractor and rate of Hydrolic vehicle and ladder including in quoted rate.
M & L for painting of Street light poles (with hydrolic vehicle / ladder) including cross arms, channel, flat iron clamps etc 9 mtr long in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos (Yellow circle and Number in black) and providing 3 Nos of radium with width 50 mm size band / strap with Red, Yellow, Green colour 300 mm apart from plinth block around the pole etc complete as all as specified and directed in Engr-in- Charge. Note:- Hydrolic Vehicle / Ladder for painting is responsibility of contractor and rate of Hydrolic vehicle and ladder including in quoted rate.
Supply and fix in replacement of MCB TPN, 63 Amps 10 KA breaking / rupturing capacity capacity 415 volt , 50 HZ conforming to IS 60898-1 including necessary connection with suitable size of copper cable complete all as directed. MAKE: Havells/L&T.
Supply and fix in replacement of LED post top lantern 40 Watt, with spun aluminium canopy & die cast aluminium spigot with opal PMMA acrylic diffuser pre wired with all accessories including making necessary connections and make it functional complete all as specified and as directed. Make : Bajaj/Havells/Philips/Wipro
Supply and fix in replacement of timer switch Astronomical type, 240volt, 50/60 Hz 16 amp/250VAC resistive of Make : L & T/ Indoassian and standard.
Supply, fix in replacement of Contactor 3 pole AC -1 40 Amps Main Pole Confugration 2 No 2 NC 415 volt fixing with Existing Box by suitable size of copper cable with suitable size of lugs. Make : L&T / Indoasian and C&J.
S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 200 x 175 x100 mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. including Taking down Unserviceable Pole Box of any description from any Height, complete all as specified and as directed.
S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 310x210x120mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. including Taking down Unserviceable Pole Box of any description from any Height, complete all as specified and as directed.
M & L for replcement of Chain sprocket in Highmast Light all as specified and directed
Supply and fix in replacement of brass batten holder for fixing of gate light. Make Anchor.
Supply and fixing in replacement of Triple pole and Neutral HRC type rewireable Swich fuse unit 100 Amp 415 volt AC 23 A 50 HZ conforming to IS 60947 1 & 3 fixing on Street light Pole with 32x4mm of MS Clamp and suitable size of nut, bolt and washers all as specified and directed. Make : L & T/ Indoasian or Equivalent to C&S/ Standard.
Supply and fix in repairs change over switch existing panel, wall or LT pole of any size and any type on load type, triple pole and neutral, 63 Amps, 415 V, 50 Hz front handle operated, including connecting and testing all as directed. MAKE: Indoasian/L & T/Havells
Supply and fixing with replacement of MCB SP 6 to 32 Amps with PVC Enclouser fixing with pole or wall for individual street light/ security light control with suitable size of clamp nut , bolt and washers.make: C&S/ Indoassian/L&T. Note: Rate of MS Clamp is include in Quoted Rates.
M&L Street Light Fitting Bracket made out from GI Pipe 50 mm Bore (dia), Light Grade, not exc. 1.20 Metre long, bend to required shape and fixing to Poles, etc. with and including Mild Steel Flat Iron Clamps 40x5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc. including Painting with One coat of Red Oxide Zinc Chrome Primer and Two coats of Aluminium Paint to all Mild Steel Works incuding taking down existing complete all as specified and as directed.
Material and labour for street light control board / box of size 0.50 X 0.50 X 0.20 m made out of 1.60 mm thick MS sheet fixed / mounted on pole by means of 2 Nos of FT clamps of size 25 X 3 mm comprising the following enclousers and connecting with suitable size of copper cable all as directed:- a) MCB, TPN, 63 Amps, - 01 No MAKE:L & T/ STANDARD OR equivalent in makes mentioned in list of makes in Appendix `C' b) Timer switch, Astronomical type operating on 110 / 240 / 415 Volts, 50 Hz MAKE: L&T OR equivalent in makes mentioned in list of makes in Appendix `C' c) Contactor ML 2, 32 Amps,415 Volt - 01 No MAKE: CAT No SS90701 OF L&T OR equivalent in makes mentioned in list of makes in Appendix `C' d) All MCB,Contactor should be connected through HRC fuse
S&F High Mast Light control board / box of size 0.50 X 0.50 X 0.20 m made out of 3 mm thick MS sheet fixed / mounted on 50 x 50 x 6 mm angle iron frame having minimum 2 ft ground clearance duly ambedded in and including PCC blocks (1:2:4) type B1 foundation for fixing of panel complete including incoming and outgoing connections with sutaible size of lugs / gland / nuts / bolts complete all as specified and directed:- a) MCCB, TPN, 63 Amps, - 01 Nos. b) Timer switch, Astronomical type operating on 110 / 240 / 415 Volts, 50 Hz. c) Contactor- 63 Amps, 415 Volt - 01 Nos. d) Contactor- 9 Amps, 415 Volt - 02 Nos e) Bypass switch 01 Nos. f) Indicator Lamp RYB. g) Control fuse 6A 01 Nos
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply and fix in replacement of LED Street light Luminaries 70 watt, with inbuilt surge protection 10 KV, Lumans output 6000 with pressure die-cast aluminium housing with toughtened glass & IP 66 protection and impact resistance IK07 fixed with suitable size of GI Bracket of length 1.2 Mtr,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box to streeght light and 4 sqmm 2 core aluminium service cable pvc insulated 2.5 RM per fitting where over head line existing for connection of street light to over head conductor complete all as specified and directed. Make: Crompton Cat part No. TRP-409-70-57-SL-GL-NSG or equivalent.
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply and fix in replacement of LED Street light Luminaries 60 watt, with inbuilt surge protection 10 KV, Lumans output 6000 with pressure die-cast aluminium housing with toughtened glass & IP 66 protection and impact resistance IK07 fixed with suitable size of GI Bracket of length 1.2 Mtr,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 core copper wire from junction box to streeght light and 4 sqmm 2 core aluminium service cable pvc insulated 2.5 RM per fitting where over head line existing for connection of street light to over head conductor complete all as specified and directed. Make: Crompton Cat part No. LST-60-CDL-M or equivalent.
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply and fix in replacement of LED Street light Luminaries 45 watt, with inbuilt surge protection 10 KV, Lumans output 4500 with pressure die-cast aluminium housing with toughtened glass & IP 66 protection and impact resistance IK07 fixed with suitable size of GI Bracket of length 1.2 Mtr,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box to streeght light and 4 sqmm 2 core aluminium service cable pvc insulated 2.5 RM per fitting where over head line existing for connection of street light to over head conductor complete all as specified and directed. Make: Crompton Cat part No. LSTS-45-CDL-M or equivalent.
Supply only in replacemet LED Drivers for 36/45 watt LED Fittings any type and any make as per sample.
Supply only in replacemet LED surg protectors for 36/45 watt LED Fittings any type and any make as per sample.
Supply only in replacemet LED Drivers for 60/65 watt LED Fittings any type and any make as per sample.
Supply only in replacemet LED surg protectors for 45/60 watt LED Fittings any type and any make as per sample.
Supply only in replacemet LED Drivers for 70/75 watt LED Fittings any type and any make as per sample.
Supply only in replacemet LED Drivers for 120 watt LED flood light Fittings any type and any make as per sample.
Supply only in replacemet LED surg protectors for 120 watt LED Fittings any type and any make as per sample.
Supply only in replacemet LED surg protectors for 200 watt LED Fittings any type and any make as per sample.
Supply only in replacemet LED Drivers for 200 watt LED flood light Fittings any type and any make as per sample.
Supply and fixing in replacement of ALL-IN-ONE Solar street light fitting,40 watt led lamp,Range ( 2 days back up) including LED light,MPPT SCC,Mono crystalline SPV Panel ,lithium ferro phosphate battery with inbuilt BMS techonology,high efficiency,LED ,MPPT Solar charge controller and Aluminium Extruded body and is specially pgogrammed to automatically control the dimming and brightness of light which increse the bach up time complete including proving 6 mtr GI tubular pole designed specically for solar light fitting including PCC work and foundation and couping( as per manufacture instruction) ,earth work complete all as specified and directed .Make : Havells cat No SOLAR AIO 40 watt and equivalent.
M & L for LED post top lantern 20 watt in repair made of pure polyster UV resistant powder coated die cast aluminium housing, integral including led lamp 20 watt and base holder as per company manufacture complete all as specified and directed Make : Wipro Cat No. LP07-251-XXX-57-CL or its equivalent.
M & L for repairing of Highmast panel box by replacing of MCB TPN, Timer switch, Contactor and also repairing the Panel box by welding of hinges, replacement of Lock etc all as per specified and directed. Note: (i) MCB TPN, Timerswitch and Contactor are paid separately. (ii) Rate Includes welding,Lock and keys , Painting in two coats of synthetic enamail and one coat of primer red oxide,
Supply and fix in replacement of MS Clamp 25x3mm with nut bolts and washers duely painted in two coats of aluminium paint and one coat of red oxide all as specified and directed by Engr-in -Charge.
M&L for road cutting upto 300mm deep and 200mm wide for crossing GI pipe line through road including making good the disturbed surface by filling mass concrete complete all as specified and directed.Note : Rate of mass concrete included in quated rate.
S&F LT cable route indicator of Cast iron not less than 100 mm dia fixed through welding angle iron supoort of size 25 mm x 25mmx5mm thick ,600mm long including two coats of synthetic enamel paint(yellow in colour) over a coat of red oxide primer planted in a PCC foundation (PCC 1:3:6) , The whole assembly of PCC iron will be planted in ground upto 30 cm complete all as specified and directed.Note : Rate of PCC foundation included in quated rate
Supply and fix in replacement of copper cable 2.5 Sqmm 3 core flexible type unarmoured cable of ISI marked complete all as specified and directed.
Supply and fix in replacement of copper conductor XLPE insulated stranded , unarmoured ,extructed PVC type ST2 sheathed , 650/1100 volt graded as per IS 7098.of size 6 Sqmm 4 Core . Make Polycab cat part No- SISLV4X610693
Supply and fix in replacement of steel wire rope Grade AISI 316, 7/19 with 6mm dia.
Supply and fix in replacement of copper conductor PVC insulated stranded , unarmoured , 650/1100 volt graded as per IS 7098.of size 4 Sqmm 5 Core . Make Polycab
M & L for replcement of Chain sprocket in Highmast Light all as specified and directed
Demolition of U/s Cement concrete in coping all as specified and directed by Engr-In-Charge.
An amount of Rs 72,937.00 shall be deducted from BOQ on account of schedule of credit
Mahindra Electric Stores
Maruti Abhiyantriki
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .