Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | L1 | Accepted-AOC single lowest bid |
| Sl No | Description | Qty | Unit | PRADEEP KUMAR.V.K L1 |
|---|---|---|---|---|
| 1.00Footpath Lighting | ||||
| 1.00 | OD262591/2025-2026:Supply installation testing commissioning of Decorative Pole 3.2/3 meter height
above the
ground level made out of GI, tubular pole having two section section, bottom section
of
minimum 900/1000mm with base dia of 114mm and upper section of minimum
2300/2000mm
with minimum dia of 60mm. The pole shaft shall be as per IS 1161. The pole shall
have base plate of
dimension 200x200x12mm/round minimum 200mm including minimum16mm
diameter 4 numbers foundation bolts of
450mm bolt length, 200mm pitch circle diameter manufactured from special steel
along with
nuts, washers, The pole shall be with inbuilt control gear tray at bottom section. The
control
gear tray is prewired with 1.5 Sq.mm cable, 6A SP MCB and 32A stud type 4 way
terminal block for loop-in / loop-out arrangement, 6 A 2 Way terminal connector and
provision
for earthing.The pole shall be suitable for wind loadings as per IS 875 part 3 1987.
Design
comply EN40 standard and basic wind speed 169kmph. Pole should hot dip
galvanized to 65
microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with
two coats
of epoxy primer and above that it should be given marine coating. The complete
system should
be hot dipped Galvanised. (Crompton Deco/K lite COLOMBIA/Kesslec ECO). | 50 | each | 13,332 ₹6,66,600 Lowest |
| 1.00 | OD262586/2025-2026:SITC of LED Decorative Classic luminaire of system wattage 50W, with minimum
dimension
315mm width and 545mm height, BIS certified with a body
and frame of high pressure die cast aluminium, a frosted PMMA protector (IK06)
fixed on tothe optical unit
, separate optical and control gear compartment accessed by opening four
screws at the top of the luminaire, a vent pressure equalization unit and pre-cabled as
required. The luminaire shall have ingress protection of IP66. Highly efficient
temperature
resistant lenses for light distribution with several optical options providing excellent
photometry to optimally cater to different applications. Overall system efficiency of
120lm/W at correlated colour temperature (CCT) 3000K, colour rendering index
(CRI) >70
and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac,
Power
Factor > 0.95, with BIS certified potted driver having internal surge protection of 4
kV and
an additional surge protection device (SPD) of 10 kV . ( Klite DYNASTY MIDI 50W
WW/
KESSLEC RILA 50W WW) | 50 | each | 12,536 ₹6,26,800 Lowest |
| 1.00 | OD326545/2025-2026:Supply ,conveyance ,installation testing and commissioning of 1200 mm 1x20 W LED tube light fitting housing made of extruded thermal polycarbonate with 6500K , color temperature with duly wired up for use on 230V AC . The light fittings shall be fixed directly on wall or ceiling with and giving connection with required length of 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. | 10 | each | 378 ₹3,780 Lowest |
| 1.00 | OD326557/2025-2026:Supply Conveyance, installation, testing and commissioning of 20W LED Flood light output greater than 120lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 2 | each | 1,268 ₹2,536 Lowest |
| 1.00 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 5 | cum | 414 ₹2,070 Lowest |
| 1.01 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). | 5 | cum | 9,985 ₹49,925 Lowest |
| 1.01 | OD262588/2025-2026:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more. | 250 | kg | 71 ₹17,750 Lowest |
| 1.01 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels | 3 | sqm | 376 ₹1,128 Lowest |
| 1.01 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | 165 | metre | 83 ₹13,695 Lowest |
Tender Value
Refer Docs
EMD Value
₹46,166
Closing Date
16 Mar 2026, 1:00 pmClosed
Executive Engineer PWD Electrical Division Kannur
PWD Electrical Division, Kannur
Development of Various Town and Junction of Eachur and Kudikkimotta with its beautification by providing drainage and footpath fixing of handrails-SITC of decorative Lights-General Electrical Work
2026_PWD_838083_2
PWD/BLDG/TR/23800/2025_6_1_1/1
Open Tender
Electrical Works
Item Rate
120 days
Kannur
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹46,166
2 Jun 2026
10 Mar 2026
18 Mar 2026
10 Mar 2026
16 Mar 2026
10 Mar 2026
Footpath Lighting
OD262591/2025-2026:Supply installation testing commissioning of Decorative Pole 3.2/3 meter height above the ground level made out of GI, tubular pole having two section section, bottom section of minimum 900/1000mm with base dia of 114mm and upper section of minimum 2300/2000mm with minimum dia of 60mm. The pole shaft shall be as per IS 1161. The pole shall have base plate of dimension 200x200x12mm/round minimum 200mm including minimum16mm diameter 4 numbers foundation bolts of 450mm bolt length, 200mm pitch circle diameter manufactured from special steel along with nuts, washers, The pole shall be with inbuilt control gear tray at bottom section. The control gear tray is prewired with 1.5 Sq.mm cable, 6A SP MCB and 32A stud type 4 way terminal block for loop-in / loop-out arrangement, 6 A 2 Way terminal connector and provision for earthing.The pole shall be suitable for wind loadings as per IS 875 part 3 1987. Design comply EN40 standard and basic wind speed 169kmph. Pole should hot dip galvanized to 65 microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with two coats of epoxy primer and above that it should be given marine coating. The complete system should be hot dipped Galvanised. (Crompton Deco/K lite COLOMBIA/Kesslec ECO).
OD262586/2025-2026:SITC of LED Decorative Classic luminaire of system wattage 50W, with minimum dimension 315mm width and 545mm height, BIS certified with a body and frame of high pressure die cast aluminium, a frosted PMMA protector (IK06) fixed on tothe optical unit , separate optical and control gear compartment accessed by opening four screws at the top of the luminaire, a vent pressure equalization unit and pre-cabled as required. The luminaire shall have ingress protection of IP66. Highly efficient temperature resistant lenses for light distribution with several optical options providing excellent photometry to optimally cater to different applications. Overall system efficiency of 120lm/W at correlated colour temperature (CCT) 3000K, colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor > 0.95, with BIS certified potted driver having internal surge protection of 4 kV and an additional surge protection device (SPD) of 10 kV . ( Klite DYNASTY MIDI 50W WW/ KESSLEC RILA 50W WW)
OD326545/2025-2026:Supply ,conveyance ,installation testing and commissioning of 1200 mm 1x20 W LED tube light fitting housing made of extruded thermal polycarbonate with 6500K , color temperature with duly wired up for use on 230V AC . The light fittings shall be fixed directly on wall or ceiling with and giving connection with required length of 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
OD326557/2025-2026:Supply Conveyance, installation, testing and commissioning of 20W LED Flood light output greater than 120lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD262588/2025-2026:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)
OD262581/2025-2026:Hire and Labour charges for Concreate/Tar road cutting as required.
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
OD262585/2025-2026:Supply and fixing 25A AC3, MNX 25, 2 Pole power contactor (L/k) conforming to IS/IEC 60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required
OD262590/2025-2026:Supply and fixing Digital Time switch 240V AC DIN/BASE mounting in the existing enclosure and giving connection as required (LK 110-240 V Digital Time Switch)
OD262587/2025-2026:Supply and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meter board
OD262582/2025-2026:Supply and fixing of Neutral link 32A, 2 way neutral links mounted on DMC/SMC base.
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD262589/2025-2026:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm GI strip
OD262592/2025-2026:Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25 mm X 3 mm G.I. strip
OD262583/2025-2026:Supply and fixing 32mm dia 6Kgff/cm2 PVC Pipe including fixing the pipe with clamp/clips at 60cm spacing. etc. as required (for service pipe)
OD282858/2025-2026:Supply and Fixing Syntex junction box GSJB 2520 With Provision for fixing 2pole isolator/DP MCB/TP MCB
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1428786.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewnit.pdf
Tender Documents • 0.02 MB
viewsbd.pdf
Tender Documents • 1.66 MB
BOQ_1428786.xls
BOQ • 0.33 MB
mom.pdf
Other Document • 0.27 MB
specificcondition.pdf
Additional Documents • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .