Executive Engineer, Electric (R&B) Division, Rajkot
Providing and Erecting E.I. and Necessary Switchgear iteams in Registrar Rooms, Stenographers Rooms, Branches and Staff Rooms in Court Building of Rajkot, Jamkandorana , Padadhari , Upleta , Bhayavadar , Vinchiya , Jasdan , Dhoraji , Jetpur & Gondal ..
327013
05 of 2026-27
Open
Electrical Works
Works
Rajkot
7 documents required · 7 mandatory
₹1,500
Executive Engineer, Electric (R&B) Division, Rajkot.
₹30,000
23 Jul 2026
23 Jul 2026
23 Jul 2026
6 Aug 2026
23 Jul 2026
Name of work: Providing and Erecting E.I. and Necessary Switchgear iteams in Registrar Rooms, Stenographers
Rooms, Branches and Staff Rooms in Court Building of Rajkot, Jamkandorana , Padadhari , Upleta
Bhayavadar , Vinchiya , Jasdan , Dhoraji , Jetpur & Gondal .
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Point wiring for Individual Plug with & earth wire of
sq.mm (Green) both are of ISI marked 1.1 kV grade FRLS
PVC insulated multi strand copper wires up to 10 mtr length,
in below type of pipe erected complete with Modular type
switch & 5 pin Plug erected on PVC / Metallic/Wooden box
1 230 Pt covered with appropriate front plate modules erected on / in 853.45
wall / ceiling as per pipe erected with following type of
accessories.[II] For 16A Plug and 16 amp switch with 2-2.5
sq.mm Cu. Wire from mcb db board.(a) with medium class
Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete Cat. III
providing and erecting Mains with 1.1 kV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected in / on wall / ceiling with
2.5 sq. mm copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of following size (A)
with medium class Rigid PVC pipe and accessories (i) 4 wire
(use earth wire of 4 sq.mm )
Providing & erecting 240 V MCB double pole switch for
motor & inductive load (C Curve) having 10 KA breaking
capacity & confirms to IS : 8828 in existing box having
following capacity (A) 6 to 32 Amp. Cat.III
Providing and erecting Sheet Steel powder coated MCB
distribution board - flush / surface mounted fitted with busbar,
neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
3, IEC 61439-1 & 3 without MCB to house appropriate nos. of
4 17 Ea MCBs.(The DBs should be used of same company of MCB to 2913.85
be used) suitable for (B) three phase incoming and single
phase horizontal type outgoing Per phase isolation type (PPI)
(b) sheet steel double door (ii)6 way
(B) three phase incoming and single phase horizontal type
outgoing Per phase isolation type (PPI) (iii)8 way
(A) single phase incoming and horizontal single phase
5 Ea outgoing (b) sheet steel double door (IP-43) (b) sheet steel 1492.78
double door (IP-43)
Plastic enclosure fitted with DIN rail suitable for incorporating
One / Two nos. MCB
Providing & erecting 415 V MCB Four Pole for Motor &
Inductive Load (C Curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following capacity
(c)63 Amp. Cat.III
providing and erecting Approved make RCCBs conforming to
IS: 12640 and having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for operation on
7 96 Ea single phase 240 V,50Hz. having characteristic of quick action 2458.34
& tripping with all advance feature & do not incorporate any
electronic component. for following Max. rating erected as
directed (ii) 40Amps. DP Cat. III
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Providing and erecting FRLS-XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for 1.1 kV.
8 600 Mtr to be laid on wall with necessary clamps or in existing trench 1689.73
/ pipe of following size of cables (J) 3 1/2 core 300 Sq.mm (
150 Sq. mm 1/2 core)
Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 50 KA
and above at 415 V having Normal current rating 400A. with
9 1 Ea variable Thermal & magnetic release suitable to work on 27751.77
A.C.supply 50 Hz. With all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 50 KA
and above at 415 V having Normal current rating 400A. with
variable Thermal & magnetic release suitable to work on
A.C.supply 50 c/s. With all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III with
Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 35 KA.
and above at 415 V . having normal current rating 250A. with
variable thermal & magnetic release suitable to work on
A.C.supply 50 Hz. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III
2 Ea With Enclouser 25345.243
Supplying and erecting triple pole & neutral 440V / 500V
panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than 1.6 Amp.
/ sq.mm (Rated current / cross section area) duly wrapped with
12 1 Rn.Mtr colour insulating tape for phase sequence of following current 7319.47
carrying capacity, erected with necessary bus bar supports
/insulators, main cable socket to each bar, erected in existing
cubical panel with necessary connections.(D) Suitable for
2 Rn.Mtr (C) Suitable for 300 Amp. capacity 4909.61
Providing & erecting weather proof, dust & vermin proof,
floor mounted front operated indoor type cubical panel board
necessary IP-42 and above protection as per approval from
engineer incharge made from 14 SWG thick CRC M.S. sheet
for outer body & doors, 16 SWG thick CRC M.S.sheet for
internal partitions with necessary accesories , supporting
angles/ flats channel including cutting, bending, drilling,
welding, riveting with internal partitions & cable alley as per
requirements & instruction of engineer-in-charge with erection
supplied switch gears, BUSBARS, suitable size of inter
connecting PVC copper wire / copper-aluminium strips, rubber
grommets, rib, bakelite control fuses/MCB for measuring
instruments, earth bus & earth bolts, foundation flange - bolts-
base Plates, sufficient nos. of hinged doors, handles with
locking arrangement and rubber gasket,heavy duty end
terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be painted
with epoxy powder coating.
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
(The rates excludes the cost of switchgears, bus bars, inter
connecting mains & Copper Aluminium strips, meters, Fuses
etc. The dimension shall be measured excluding base beams)
2.707 Sq.mtr The panel shall be supplied with following approved 14902.55
manufacturers with following size. (B) The standard
companies switch gear shall be used and only manufacturers at
CPRI approved factory (i) with 350mm depth
Supplying & erecting earth pit of minimum bore dia.150mm
size approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm having 80-
200 Micron galvanising, Inner pipe dia of 25 mm having 200-
250 Micron galvanising, connection terminal dia of 12mm
with constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for following
type of applications with chamber and heavy duty cover.
(A)(approved make OEM has to submit test certificate
including value of earth resistance of installation duly stamped
and signed by agency and officer Incharge has to ensure the
value of earthing resistane mentioned in test Certificate) &
having back filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency. (a) For
Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Providing and, fixing heavy duty flange type brass double
compression type cable gland with rubber ring for PVC
15 6 Ea insulated armoured cable complete with out going tails, 280.78
insulating tape etc for following size of cables. (I) 3 & 1/2
core 300 Sq. mm
Solder less crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with high
16 24 Ea pressure tool & connected to switchgear terminals with 98.98
brass/cadmium plated nut bolts in an approved manner. (K)
Making trench in Hard Murrum / Tar Road of suitable width of
90 cm or required depth for laying any size of cable or
locating the fault all over the run and back filling the same
and making the surface as normal ground.
(B) If additional machinery like hammer driller or JCB use
Providing & laying approved make Double walled corrugated
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required
depth in existing trench for laying of cable. below ground /
road surface for enclosing cable (C))90 mm outer dia
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Supplying and erecting approved make panel mounting type
Digital Voltmeter having 3 digits LED display, 0 to 750 AC
19 3 Ea Volts range erected on existing panel board with all 1275.63
connection, wiring etc .with manufacturers calibration
Supplying and erecting approved make panel mounting type
Digital Ammeter having 3 digits LED display, external CT
operated, calibrated for 0 to 1000 Amps suitable to operate on
500 Volt AC , erected on existing panel board with all
connection, wiring etc .with manufacturers calibration
Supplying and erecting Ammeter / Voltmeter selector switch
21 6 Ea for 3 phase AC Supply 500 V on existing panel board with 317.14
necessary connections.
Providing & erecting L.T. Current Transformer with bar
primary 50/5 to 1000/5 ratio 15 VA burden erected in existing
CRCA box duly secured with insulating materials connected to
Supplying and erecting approved make suitable panel indicator
23 9 Ea LED type lamp, lens cover, complete erected with necessary 43.43
providing and erecting Mains with ISI marked, 1.5KV grade
electrolyte multi stranded, annealed copper conductor with
heat resistant PVC insulated conforms to IS 694, IEC -
24 12 Mtr erected in existing pipe of following size (Specifically for 1473.59
control panel, relays, power switchgears, motor starters &
control wiring) with required size of copper lugs, nuts and
bolts if required.. (m) One wire 120.00 sq. mm
112 Mtr (g) One wire 16.00 sq. mm 177.76
Note:- The Credit of dismentalled materials for Rs.00.00 shall be recovered from the First R.A. bill payable to the contrator
and there after the dismentalled materials shall be the property of the contractor.
I/We am/are willing to carry out the work at__________________% above/below (in
figures)_____________________________________percent Above / below (in words) the estimated rates mentioned above amount
of my\our tender works out as under :-
Estimated amount put to Tender Rs. _________
Deduct________% below Rs. _________
Net Amount Rs. _________
Estimated amount put to Tender Rs. _________
Net Amount Rs. _________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local
situation regarding material,labour and other factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications
and other tender documents of this work and agree to execute the same accordingly.
C Any Excess in Tender Item/Extra Item if Needs to be Execute. Contractors has to carry out work on the
instruction of Competant Authority on Tender Submitted rate,No Excuse will be Accepted.Hence Contractor
are Requested to quote the rate considering this condition.
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
D Contractor are requested to quote the Tender by considering that payment will be made after availibility of
grant.Contractor has to start the work immediately after issue of Work Order and as per instruction of Engineer-
in-Charge irrespective of availibility of grant.
E "This estimate has been prepared on the new SOR wich is exclusive of GST hence GST additional will be paid
to the agency as per existing guidelines."
(Signature of the Contractor)
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ONLINE_NOTICE(R-2)(dn) RJT.pdf
SCH-B.pdf
MAKE FOR ELECTRICAL ITEM(upadatemake list).pdf
SPECIAL CONDITION (2).pdf
SBD.docx
DOCX
Contractor_Registration_Paripatra__1_.pdf
EMD GR.pdf
GR for Extra Item.pdf
GR for single Tender.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].