Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC VILLAGE SATOJ TEHSIL SUNAM DISTT SANGRUR | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹20.7 L+₹1.8 L (9.60%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹21.0 L+₹2.1 L (11.3%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLAGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹23.7 L+₹4.8 L (25.2%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
Refer Docs
EMD Value
₹47,400
Closing Date
9 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PHALODI
Military Engineer Services Garrison Engineer (AF) Near Kundal Village, Phalodi (Rajasthan)-342 301
PROVN OF CERTAIN SANCTIONED MINOR, REVENUE AND LBW WORKS (B/R-II) AND INCLUDING SOME WORKS OF E/M IN DOMESTIC AREA AF STN PHALODI
2020_MES_393773_1
8288/A/E8
Open Tender
Civil Works
Item Rate
180 days
PHALODI
All contractors enlisted with MES in Class E and above and category a (i) subject to the remarks wrt performance in respect of Wks in hand reflected in Workload return (WLR) Circulated by competent engineer authority
7 documents required · 7 mandatory
₹500
GE (AF) PHALODI
₹47,400
Yes
30 Dec 2020
9 Nov 2020
12 Dec 2020
9 Nov 2020
9 Dec 2020
23 Nov 2020
9 Nov 2020 - 19 Nov 2020
60 days
Amount
B/R Works :- Surface excavation n.exc 30cm deep and averaging 24cm deep and getting out in soft/loose soil, complete all as specified and directed.
Surface dressing n.exc 15 cm deep and getting out in soft/ loose soil complete all as specified and directed. Note :- Watering and removing surplus soil to a distance n exc 50m and making good surface deemed to be included in quoted rate.
Excavating in post holes (or similar holes) in soft/loose soil, each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm around foundation concrete as ordered, watering and removing surplus soil to a distance not exceeding 50 m and making good surface, complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in soft/loose soil, complete all as specified & directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in any type of soil, complete all as specified & directed.
Excavation over areas n. exc 1.5 mtr deep and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material to a distance n.exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified & directed.
Demolition of stone slabs/ cement concrete (reinforced) as in platform, etc., (reinforcement cut as required to facilitate demolition) of any thickness, jointed in any mortar and removal all rubbish material to a distance n.exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified & directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar complete all as specified & directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed.
Demolition of brick work or stone/ boulder/PCC solid block masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material complete all as specified directed.
Taking down wooden/steel chowkats or frame with shutters (without taking off shutters) from the frame exc.1.50 Sqm but not exc. 4.00 Sqm each & including hardware/iron mongery complete all as specified and directed.
Formation rolling and consolidating surfaces in cutting with power road roller 8 to 12 Tonne complete all as specified & directed.
M & L for broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M & L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in pathway or sub base of floors, finished the surfaces even and fair complete all as specified and directed.
M & L for 75mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in flooring, finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in flooring, finished the surfaces even and smooth without using extra cement and including making impressions of expanded metal, whilst the concrete is green complete all as specified and directed.
M & L for 75mm thick PCC 1:3:6, type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 2 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed.
M & L for 60mm thick machine pressed precast interlocking paving blocks factory casted using grey cement and no pigment, casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, confirming to IS-15658-2006 and of shape haxagon/ triangular/ zigzag/ I-shaped etc. as directed having compressive strength not less than 350 Kg/ Sqcm (M-35 Grade) laid over and including 25 to 30mm thick layer of sand cushioning including filling the interstices with & including sand complete all as specified and directed.
M & L for 80mm thick machine pressed precast interlocking paving blocks factory casted using grey cement and pigment, casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, confirming to IS-15658-2006 and of shape haxagon/ triangular/ zigzag/ I-shaped etc. as directed having compressive strength not less than 400 Kg/ Sqcm (M-40 Grade) laid over and including 25 to 30mm thick layer of sand cushioning including filling the interstices with & including sand complete all as specified and directed.
M & L for providing cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating & including use and waste of formwork (straight or curved) all exposed surface of concrete finished fair complete all as specified and directed.
M & L for providing cement concrete 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in surface channels and drains and benching & including finishing the top of benching even and smooth using extra cement complete all as specified and directed. Note :- Forming fair finished channel shall be measured and paid separately under respective item of the BOQ.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement & including forms, moulds mitred/stopped ends etc complete all as directed. Note :- Measurment shall be taken only for inner girth.
M & L for soft/loose earth filling under floors and including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick each and consolidation complete all as directed. Note:- Earth obtained from item No. 04 (here-in-before) shall be used.
M & L for anti-termite treatment to the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M & L for anti-termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M & L for 40mm thick cement concrete 1:2:4 Type B-0 (12.5 mm graded crushed stone aggregate) as in Damp proof course to horizontal or vertical surfaces & including necessary formwork complete all as specified and directed.
M & L for PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate as in padding and levelling course on roof and terrace laid to a minimum consolidated thickness of 30mm, finished even & fair, laid and compacted in slope complete all as specified & directed.
Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.5 Kg/Sqm of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd or Hydrostop water proofing memdrane manufactured by M/S TIKIDAN as approved by GE, black finish reinforced with non-woven polyester matt (weighing not less than 150 gm/Sqm), with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd} at the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing with a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, over and including screed bed or bedding layer of mortar, 10 mm thick, in cement mortar 1:3, for laying floor finishes complete all as specified and as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, applied @1.20 Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 60cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen. (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M & L for TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M & L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M & L for plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections and similar work con- forming to Fe.410W.Gde-E-250 quality B, complete all as specified and directed.
M & L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) & including distance pieces, cleats etc. con- forming to Fe.410W.Gde-E-250 quality A, complete all as specified and directed.
S & F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instructions complete all as specified and directed.
Cutting upto a depth of 5 cm into with or without reinforcement concrete slab/walls and trimming surfaces as required, girth exc. 30cm complete all as specified and directed.
M & L for running welding not exc 2.5 cm in length, thickness of metal to be welded exc 6mm but not exc 9mm complete all as specifed and directed. Note :- The rates include for cleaning and preparing the surfaces to be welded together, holding the members in true position while welding and bevelling of edges, as required, in the case of metal exc 3mm thick.
M & L for reinforced cement concrete Design Mix M-25 as in foundations, including rafts, footings, foundations beams, plinth beams, bases for columns etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in columns, pillars piers, posts & struts etc complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in beams, cantilevers, bressummers and lintels over 1.5m span complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in Chajjas complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade and the like complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
Use and waste of flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to sides of pillars (square, rectangular or polygonal), posts, struts, piers, columns and stanchions for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to fins, louvers, fascia for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to chullah hoods, chajjas, troughs and similar items including edges for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for fair finished surfaces of concrete complete all as specified and directed.
S & F for anodised aluminium snap grid frame work of size of grid 605mm x 605mm for false ceiling complete all as specified and directed.
M & L for providing and fixing 12mm thick perforated particle board/tiles for insula-tion and accoustic purposes, 600mm x 600mm in size, fixed with nails to timber frame work or with staples on snap grid as per Manufacturer's Instructions complete all as specified and directed.
S & F of Gl frame size of grid 605mm x 605mm work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
M & L for providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturer's instructions complete all as specified and directed.
M & L for providing and fixing Gypsum Board 12mm thick in wall fixed with screw as per manufacturer's instructions complete all as specified and directed.
M & L for precast cement concrete 1:5:8 using crushed stone aggregate block masonry with solid blocks exc 10cm in width and setting in cement and sand mortar 1:6 complete all as specified and directed.
M & L for plastering 5mm thick on concrete surface of ceiling in CM 1:3, finished even and smooth without using extra cement and including provision of sagol finish of plastered surface complete all as specified and directed.
M & L for plastering 5mm thick on concrete surface of ceiling in CM 1:3, finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work, PCC block masonary or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M & L for rendering 15 mm thick in two layers on stone masonry surfaces or on other than fair faces of brick/PCC block masonry first layer 10mm thick in cement mortar 1:6 and second layer 5mm thick in CM 1:4 mixed with WPC 3% by wt of cement and finished even and smooth without using extra cement complete all as specified and directed. Note :- Supply only WPC shall be measured and paid separately under respective item of the BOQ.
M & L for rendering 15 mm thick in two layers on fair faces of brick/PCC block masonry of walls, first layer 10mm thick in cement mortar 1:6 and second layer 5mm thick in CM 1:4 mixed with WPC 3% by wt of cement and finished even and smooth without using extra cement complete all as specified and directed. Note :- Supply only WPC shall be measured and paid separately under respective item of the BOQ.
Supply only integral water proofing compound ISI marked as approved complete all as specified and directed.
M & L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work, PCC block masonary or concrete surfaces of walls, mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing compound shall be measured and paid separately under respective item of BOQ.
S & F powder coated (thickness of powder coating not less than 50 micron) anodised aluminium frame for doors, windows, ventilators, partions with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S & F for powder coated (thickness of powder coating not less than 50 micron) aluminium door shutters, aluminium section weighing not less than 0.55 Kg/m & including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door of 150mm, tower bolts 2 Nos in each door of 150mm, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. Note :- (i) Supply only Glass shall be measured and paid for sepparately under respective item of the BOQ. (ii) Fixing of Glass and other filling material in panel deemed to be included in quoted rate of this item.
S & F powder coated (thickness of powder coating not less than 50 micron) aluminium window and ventilator shutters, fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete all as specified and directed. Note :- Supply only Glass shall be measured and paid for sepparately. Fixing of Glass and other filling materia in panel deemed to be included in quoted rate of this item.
Supply only 6.3mm thick tinted sheet glass and glazing with aluminium bedding (beading included with shutter) & rubber gasket fixed in aluminium doors, windows & ventilators etc, of any size as per site requirement complete all specified and as directed.
Supply only 5.5mm thick sheet glass, ordinary quality and glazing with aluminium bedding (beading included with shutter) & rubber gasket fixed in aluminium doors, windows & ventilators etc, of any size as per site requirement complete all specified and as directed.
Supply only 5.5mm thick sheet glass, ordinary quality frosted one side and glazing with aluminium bedding (beading included with shutter) & rubber gasket fixed in aluminium doors, windows & ventilators etc, of any size as per site requirement complete all specified and as directed.
Supply only 4.0mm thick sheet glass, ordinary quality and glazing with aluminium bedding (beading included with shutter) & rubber gasket fixed in aluminium doors, windows & ventilators etc, of any size as per site requirement complete all specified and as directed.
M & L for 9mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination fixed with screws to frame work complete all specified and as directed.
S & F of cast brass fanlight pivot with plate size 25mm x 65mm and suitable for shutter of 30mm thickness and fixed complete all specified and as directed.
S & F for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in floor complete all as directed.
S & F of 150mm (overall length of cover plate), floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as directed.
S & F for brass mortice lock, vertical type, size 100mm, 4 Levers with escutcheon plates & two keys fixed in alumnium frame complete all as directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) confirming to IS-13755 of grade B11 (a), area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, for laying floor finishes complete all as specified and as directed.
M & L for 300x200x7-8 mm thick glazed ceramic coloured tiles confirming to IS-13712 of grade B11 (b), as on vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles and including 10mm thick rendering in CM 1:4 on stone/PCC block masonry surfaces or on other than fair faces of brick masonry surfaces of walls to recive wall tiles, finished even and fair, complete all as specified and directed.
M & L for 20-25mm thick machine cut Kota stone slab flooring laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 20 mm thick screed bed in CM 1:4 & including rubbing and mirror polishing complete all as specified and directed.
M & L for 20-25mm thick machine cut Kota stone slab as in risers of steps, skirting, dado and pillar laid over and including 10 mm thick rendering in CM 1:3 and jointed with grey cement slurry & mixed with pigment to match the shade of the slab & including rubbing and mirror polishing complete all as specified and directed.
M & L for 20mm thick Granite (of any type) work (table rubbed and polished), machine cut, as in cooking platform and similar works, as in single piece, laid and jointed with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including cutting and polishing (half mirror polish i.e. half granite polish as per local trade practice), over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
M & L for 20mm thick Granite (of any type) work (table rubbed and polished), machine cut, as in risers & treads of steps, jambs, pillars, wndow cills and similar works, as in single piece, laid and jointed with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including cutting and polishing (half mirror polish i.e. half granite polish as per local trade practice), over and including 15 mm thick screed bed/rendering in CM 1:4 complete all as specified and directed.
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M & L for preparing newly plastered surfaces and applying three coats of white wash on ceiling/soffits of chajjas complete all as specified and directed.
M & L for preparing newly or previously untreated false ceiling surfaces and applying two coats of oil bound distemper (OBD) over and including one coat of chalk whiting preparatory to distempering complete all as specified and directed.
M & L for preparing newly plastered walls surfaces and applying two coats of oil bound distemper (OBD) over and including one coat of chalk whiting preparatory to distempering complete all as specified and directed.
M & L for preparing newly plastered walls surfaces and applying two coats of cement base paint over and including one coat of alkali-resistant priming paint complete all as specified and directed.
M & L for preparing old plastered walls surfaces and applying one coat of oil emulsion distemper complete all as specified and directed.
M & L for preparing old plastered surfaces of walls and applying one coat of white wash complete all as specified and directed.
M & L for preparing old surfaces plastered or unplastered surfaces of ceilings and applying one coat of white wash complete all as specified and directed.
M & L for preparing old decorative plastered surfaces of walls and applying one coat of cement base paint of first grade quality, complete all as specified and directed.
M & L for preparation of old painted wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint of 1st grade quality complete all as specified and directed.
M & L for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint of 1st grade quality complete all as specified and directed.
M & L for preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of 1st grade quality over and including a coat of red oxide primer complete all as specified and directed.
Taking down existing cast iron soil/waste pipe of any length fixed on wall/laid in floor with fittings & including cutting of holes and making good surface to match with existing complete all as specified and directed.
S & F of 75 mm outlet cast iron nahani traps with grating & including jointing to vent/waste pipe fixed in cement concrete type B1 (1:2:4) fixed to wall complete all as specified and directed.
S & F of 100 mm dia stainless steel grating fixed to nahani trap complete all as specified and directed.
S & F of cast iron, spun pipe, 75mm bore, soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed.
S & F of cast iron, spun pipe, 75mm bore, soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
S & F of 75mm bore cast iron cowls complete all as specified and directed.
S & F of 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified & directed.
S & F of 75mm bore cast iron branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified & directed.
S & F of 75mm bore cast iron sockets (double) collars complete all as specified & directed.
S & F of PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S & F of kitchen sink or laboratory made of stainless steel 1.0 mm thick with plug washer and waste coupling & including bedding in cement mortar on to dwarf wall or including and fixing cantilever brackets and connecting union pipe, including 40mm dia waste coupling, overall size 495mm x 420mm & bowl size 410 x 330 x 160 mm complete all as specified and directed.
S & F in renewal of kitchen sink or laboratory made of stainless steel 1.0 mm thick with plug washer and waste coupling & including bedding in cement mortar on to dwarf wall or including and fixing cantilever brackets and connecting union pipe, including 40mm dia waste coupling, overall size 915mm x 460mm & bowl size 410 x 330 x 160 mm complete all as specified and directed.
S & F of 32mm dia bore low density polyethylene (LDPE) pipes of pressure rating 6 Kgf/Sqcm complete all as specified and directed.
Taking up or down existing steel tubing and connections & including cleaning serviceable pipe internally/externally for stacking properly in safe custody and removing unserviceable pipe from site complete, all as specified and directed for following bore pipes:-
15 mm bore dia pipe
20 mm bore dia pipe
25 mm bore dia pipe
S & F of unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed to walls, ceilings or in floors etc., and including fittings complete, all as specified and directed for following bore pipes:-
15 mm bore dia pipe
20 mm bore dia pipe
25 mm bore dia pipe
S & F for 20 mm bore gun metal, globe or gate valves cast copper, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked, complete all as specified and directed.
S & F for 25 mm bore gun metal, globe or gate valves cast copper, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked, complete all as specified and directed.
Taking down existing brass bib taps/stop cock complete all as specified and directed.
S & F of bib taps 15mm bore dia, cast copper alloy, chromium plated fancy type, long body with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule etc., complete all as specified and directed.
S & F of brass CP mixer 15 mm bore dia for mixing hot & cold water screwed down for iron pipe or UPVC pipe line as in sink complete all as specified and directed.
S & F of 15 mm bore dia stop valve, fancy type, chromium plated, brass, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle ,screwed both ends for iron/UPVC pipe or for union and fixed complete all as specified and directed.
S & F of PVC connection 15mm dia 600mm long with PTMT check nut and washer etc, ISI marked complete all as specified and directed.
E/M ITEMS :- M & L for point wiring for one light point / bell point controlled by one, 1 way switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FR-LSH in and including non metallic rigid PVC heavy duty concealed conduit not less than 20 mm dia, ISI marked, including new steel terminal sunken pressed type boxes with 3mm thick plastic laminated bakelite (Hylam) sheet top cover for mounting switches, sockets, regulators, bell push etc, for one light point, fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable FR-LSH connected to common earth dolly complete including cutting, chasing the surface and then making good the same in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed. Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items here-in-after of BOQ (Sch 'A' ). Make of wire :- Anchor/Havells/Polycab/Finolex. Make of conduit :-Polycab/Plaza/kalinga/precision.
S & F modular switch, one way, 1 module, 6 Amp 240 Volt, AC (ISI Marked) complete all as specified and directed.
S & F Switch socket combination 2 in 1, 3 pin, 5 and 15/16 Amps, flush type, universal, 230 volts, ISI marked complete all as specified & directed. Note:- Switch and socket shall be of same make.
S & F ceiling rose surface bakelite 65 x 50mm size, two to three phase terminals with back plate, ISI marked complete all as specified and directed.
S & F of PVC rectangular block (Gang Box) for mounting, 15 Amps switches & sockets etc. with 3 mm thick plastic laminated bakelite hylum sheet cover of size 4 module, ISI marked complete all as specified and directed.
S & F sub main wiring with two single core PVC unsheathed insulated copper cable of 2.5 Sqmm size, multi stranded (FR-LSH) conductor 1100 volts grade drawn-through and including UPVC conduit, heavy duty of size not less than 20mm dia, including accessories such as tee, bend elbow etc, ISI marked with & including one run of 2.5 Sqmm copper conductor unsheathed multi stranded FR-LSH earth wire earth continuty and connected to common earth dolly complete all as specified and directed. Note :- Two run of 2.5 Sqmm copper cable and one run of 2.5 Sqmm copper wire earth continuty conductor and UPVC conduit of size not less than 20mm dia with accessories shall be measured as one length. Cable & conduit shall be of ISI marked.
S & F stepped type, electronic fan regulator, flush type, on the existing phenolic laminated sheet etc. as reqd, ISI marked, complete all as specified and directed.
S & F of LED trimline high performance batten 10 Watt LED luminaire comprises of extruded channel in thermally conductive material, high translucent serrated milky white diffuser is used to get glare free and smooth light distribution, efficiency : 100 lumen/watt complete fitting fixing on wall/ ceiling and including connecting with two core copper conductor FR-LSH flexible cable 23/0.00076 complete all as specified and directed. Make :- Cat part No LDL-10-WW of Crompton or equivalent Make to Havells/ Bajaj/Philips/Wipro.
S & F ceiling fan, 1200mm sweep, 5 star rating, suitable for 230 Volts, 50 Hz, AC supply with down rod & canopy and including provision of fan hook in ceiling for fixing of ceiling fan & including necessary electric connection with 1 Sqmm, three core, flexible copper multistranded conductor cable FRLSH complete all as specified & directed.
Supply, fixing, testing and commissioning (maximum energy efficient type) (Five star rated) suitable for 8 bar pressure, water heater (Geyser) storage type 25 liters capacity, 230 Volts, 50 Hz, vertical type, outer ABS rust free body, glass lined inner stainless steel walled tank, grouting of studs in wall in cement mortar (1:3) including clamps, nuts, bolts, washers and incl provision of two numbers flesible PVC connection heavy duty 450mm long with brass nuts, complete all as specified and directed.
Supplying, laying, jointing, testing and commisioning of cross sectional area 3.5 core 25 Sqmm LT under ground cable, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade, laid in trenches / ducts / encased in GI pipe / fixed to pole/wall complete all as specified and directed Note :- Exacavation and earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid seprately under respective items of the BOQ.
M & L for dry tibba sand free from clay for cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover to cable all as per standard schedule rates Part-I (2009) complete all as specified and directed. Note:- Thickness after punning shall be considered for payment.
Supplying and laying of un-reinforced precast cement concrete cable cover, Class LV, Type-I, flat, size 250 mm x 150mm x 40mm laid dry and abuting each other with gap between adjecent cover not exceeding 10mm over UG cable for protection complete all as specified and directed.
Supply, laying and fixing GI pipe 50 mm bore light grade for protection of cable as in trenches/along pole / wall / laid under the road / laid under the floor etc., including clamps complete all as specified and directed. Note :- Excavation & earth work shall be measured & paid for separately under respective item of this BOQ.
Aggarwal brothers and company
M/S HARIOM CONSTRUCTION COMPANY
M/S BAKSARAM AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .