Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.1 L+₹97,994 (5.11%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹22.1 L+₹3.0 L (15.6%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹23.6 L+₹4.4 L (23.2%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance Not being L1 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
12 Sept 2024, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361 150
Repair/ Replacement and maintenance of Internal Electric Supply and rewiring to certain Md and OTM Accn of Zone A area under GE (I) Navy Jamnagar
2024_MES_665904_1
8772/VAL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE (I) Navy Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹66,000
Yes
23 Sept 2024
13 Jul 2024
14 Sept 2024
13 Jul 2024
12 Sept 2024
29 Jul 2024
Amount
Notes applicable to all items of BOQ :- (i) The contractor shall check the fittings / fixtures and wiring as per the complaint given by the Engineer-in-Charge / concerned JE. Spares being replaced shall be intimated by JE and the replaced spares shall be measured and paid under respective items of BOQ and no extra payment will be done for the same. (ii) It is the responsibility of the Contractor to ensure that day to day complaints slips are collected every morning before distributing labours from JE from MES service centre and attend & complete the complaints the same day irrespective of any number of complaints and return back the complaint slip duly signed by the User to JE the same evening as a token of complaint rectified as such contractor to make all arrangements including supply of materials required for attending complaints without any delay, the quoted rate against various items shall deemed to be inclusive of above aspects.
Taking down existing batten type light fitting of any description & fixed in any position and S&F new clear white 20 Watt wall mounted 4 ft LED batten type decorative light fitting, minimum CCT 5700K, 230 Volts, 50 Hz, extruded aluminium housing & polycarbonate diffuser, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
Taking down existing batten type light fitting of any description & fixed in any position and S&F new clear white 10 Watt wall mounted 2 ft LED batten type decorative light fitting, minimum CCT 5700K, 230 Volts, 50 Hz, extruded aluminium housing & polycarbonate diffuser, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
S&F in repairs 9 Watt LED Bulb (Non-dimmable) warm white fixed at site and testing after completion complete all as specified and as directed.
Taking down existing street/ security light fitting of any type & fixed in any position and S&F new 45 Watt LED street/ security light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixed on walls or steel/concrete pole at any height including making connection from ceiling rose/ Junction Box to light fitting with and including three core 1.5 Sqmm cable multistranded copper conductor PVC insulated & PVC sheathed, 1100 V grade of required length fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion, fixed over & including mounting bracket made of 32mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, complete all as specified and as directed.
Taking down existing Recess/ Pendent mounted light fitting of any type & fixed in any position and S&F new clear white 45 Watt LED light fitting, decorative, energy efficient, Recess/ Pendent mounted 2ft x 2ft decorative panel with white powder coated CRCA housing and full mounted acrylic diffuser, flicker free driver, minimum CCT 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.90, 230 Volts, 50 Hz, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
Taking down existing Recess/ Pendent mounted light fitting of any type & fixed in any position and S&F new clear white 36/40 Watt LED light fitting, decorative, energy efficient, Recess/ Pendent mounted 2ft x 2ft decorative panel with white powder coated CRCA housing and full mounted acrylic diffuser, flicker free driver, minimum CCT 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.90, 230 Volts, 50 Hz, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
Taking down existing Recess/ Pendent mounted light fitting of any type & fixed in any position and S&F new clear white 33/36 Watt Ultra Slim LED light fitting, decorative, energy efficient, Recess/ Pendent mounted 1ft x 4ft decorative panel with white powder coated CRCA housing and full mounted acrylic diffuser, flicker free driver, minimum CCT 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.90, 230 Volts, 50 Hz, including suspended accessories etc, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
Taking down existing light fitting of any type & fixed in any position and S&F new clear white 36/40 Watt LED panel light fitting, recess/ pendant mounted for POP False Ceiling 2ft x 2ft panel with white powder coated CRCA housing and full mounted acrylic diffuser, flicker free driver, minimum CCT 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.90, 230 Volts, 50 Hz, including necessary clips/accessories for fixing, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
Taking down existing spot/down light fitting of any type & fixed in any position and S&F new 12/15 Watt wall/ ceiling mounted deep recessed spotlight COB down light with die cast aluminium housing, clear PMMA/polycarbonate/toughened glass diffuser, minimum CCT 3000K, decorative fixture, fixed in any position on wall/ ceiling by Screw/ nut bolt properly as per site requirement with all accessories and making necessary electrical connections and testing on completion complete all as directed. Make : Crompton Cat No. CDR-212-12-30/40-SL-NWH, Bajaj Cat No. BRDCSL 15W LED WH, Surya Cat No. SLE DLR 12W STELLAR PRIME XX, Jaquar Cat No. LERS02R015XW or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs ceiling rose surface bakelite White/ Ivory/ Urea finish 50mm dia three terminals including PVC square mounting block & electric wiring connection complete all as specified and as directed.
S&F in repairs switch piano, flush type, single pole, one way 5/ 6 Amp, complete all as specified and as directed.
S&F in repairs switch socket combination 2 in 1, 3 pin, 6 Amp, flush type, 240 Volt, complete all as specified and as directed.
S&F in repairs switch socket combination 5 in 1, 6 and 16 Amp, flush type, 240 Volt, complete all as specified and as directed.
S&F in repairs bell push, piano flush type, single pole, 6 Amp, complete all as specified and as directed.
S&F in repairs Bell, Ding Dong type, 230 Volt AC supply, Single Pole, complete all as specified and as directed.
S&F in repairs modular bell push, 6A, 1 module with all accessories complete all as specified and as directed. Make: Legrand Cat No 6755 04 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs modular switch, one way, 6 Amp, 1 module with all accessories complete all as specified and as directed. Make: Legrand Cat No. 6755 01 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs modular switch, one way, 16 Amp, 1 module with all accessories complete all as specified and as directed. Make: Legrand Cat No. 6755 11 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs molular Socket, 6 Amp, 2/3 pin combined, 2 module with all accessories complete all as specified and as directed. Make: Legrand Cat No. 6755 52 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs modular Socket multipurpose 6 / 16 Amp - 2/3 pin combined, 2 module with all accessories complete all as specified and as directed. Make: Legrand Cat No. 6755 55 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair step type fan regulator 100 W, 2 module, AC, 230V, electronic complete all as specified and as directed. Make: Legrand Cat No. 6755 30 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair step type fan regulator, AC, 230V, electronic on the existing phenolic laminated sheet etc complete all as specified and as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, VTPN, TPN, Vertical, 4 Way, flush mounted & surface mounting, suitable for fixing 3 Pole / 4 Pole MCCBs & MCBs, 415 Volts with 200 Amps rated bus bar, DB fitted with bus bar neutral links blank plates, fitted with and including MCCB, 4 Pole, 160 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with Thermal Magnetic Protection - 01 No., complete all as specified and as directed. Make of DB :- Legrand Cat No. 5077 50 or equivalent in makes mentioned in Appendix 'B' here-in-after. Make of MCCB :- Legrand Cat No. 4200 97 or equivalent in makes mentioned in Appendix 'B' here-in-after. Note : (i) Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) Quoted rates shall be inclusive of DB & MCCB as above. (iii) DB & MCCB of same make shall be provided.
S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 12 way with 200 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 8 way with 200 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 4 way with 200 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 2 way without bus bar, single door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, TPN, 4 way with 200 Amps rated bus bar, double door, 415 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete 240 V with one Single Pole MCB 20 Amps, 10 kA, 'C' Curve complete all as specified and as directed.
S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.
S&F in repairs MCB SPN 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.
S&F in repairs MCB SPN 40 to 63 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.
S&F in repairs MCB TPN 32 Amp, 415 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.
S&F in repairs MCB TPN 63 Amp, 415 V, 50 Hz, AC supply, 10kA, 'C' Curve, complete all as specified and as directed.
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including heavy duty PVC casing and capping double lock type (minimum 25 mm wide, ISI marked) with accessories or non-metallic rigid PVC conduit (heavy duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc, fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws all as per IS, terminated in & including new sheet metal box, terminal plates with all accessories, concealed MS box/ PVC modular box with cover suitable for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving, sinking for boxes and making good in CM 1:4 and applying suitable matching painting as required shall deemed to be included in quoted rate of this item.
All as per serial item No. 36 here-in-before but for one 3 pin 5/6 Amp modular switch socket on same board with other switches.
All as per serial item No. 36 here-in-before but for one 3 pin 5/6 Amp modular switch socket on independent board.
All as per serial item No. 36 here-in-before but for one 16 Amp and 6 Amp (3 pin) combined, modular switch socket on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sheet metal box, terminal plates with all accessories, concealed MS box/ PVC modular box with cover suitable for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 and applying suitable matching painting as required shall deemed to be included in quoted rate of this item.
All as per serial item No. 40 here-in-before but for one 3 pin 5/6 Amp modular switch socket on same board with other switches.
All as per serial item No. 40 here-in-before but for one 3 pin 5/6 Amp modular switch socket on independent board.
All as per serial item No. 40 here-in-before but for one 16 Amp and 6 Amp (3 pin) combined, modular switch socket on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
Taking down carefully existing serviceable copper/ aluminium point wiring (light, fan, socket or power) complete, fittings such as switches, ceiling roses, pendants, regulators, socket etc and re-fixing the all item on same or different location including necessary electrical connection and testing after completion, complete all as specified and as directed. Note : Where replacement of any unserviceable accessory is required at site, same shall be measured and paid for separately under relevant item of this Schedule.
Taking down carefully existing serviceable DB/ Meter of any capacity & any type and re-fixing the same after repair work including necessary electrical connection and testing after completion, complete all as specified and as directed. Note : Where replacement of any unserviceable accessory is required at site, same shall be measured and paid for separately under relevant item of this Schedule.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor cable, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade (ISI marked) cables, drawn through & including suitable size of heavy duty PVC casing and capping double lock type (ISI marked) with accessories or heavy duty non-metallic rigid PVC conduit (ISI marked) & conduit fittings/accessories, fixed on wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Note :- 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable and casing and capping/ conduit with accessories shall be measured as one run length for payment purpose.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor cable, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade (ISI marked) cables, drawn through & including suitable size of heavy duty PVC casing and capping double lock type (ISI marked) with accessories or heavy duty non-metallic rigid PVC conduit (ISI marked) & conduit fittings/accessories, fixed on wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Note :- 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable and casing and capping/ conduit with accessories shall be measured as one run length for payment purpose.
M&L for sub main wiring with 04 runs of 6 sqmm (nominal area) size main cable & 02 runs of 6 sqmm size earth continuity conductor cable, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade (ISI marked) cables, drawn through & including suitable size of heavy duty PVC casing and capping double lock type (ISI marked) with accessories or heavy duty non-metallic rigid PVC conduit (ISI marked) & conduit fittings/accessories, fixed on wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Note :- 04 runs of 6 sqmm size main cable, 02 runs of 6 sqmm size earth continuity conductor cable and casing and capping/ conduit with accessories shall be measured as one run length for payment purpose.
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with copper stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 core (ISI marked) fixed on wall/ pole or laid in trenches/ floor etc including dismantling & taking out old unserviceable cable complete all as specified & as directed.
S&F in repairs heavy duty PVC casing and capping, minimum 25 mm wide, double lock type (ISI marked) with accessories for existing wiring of light point, fan point, bell point, PVC boards, with & including necessary screws, bolts, nuts, drilling etc. and making good disturbed surfaces complete all as directed.
M&L for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking out existing aluminium strip complete all as specified & as directed.
M&L for galvanised iron strip 32 x 6mm buried in ground / fixed on wall including taking out existing GI strip complete all as specified and as directed.
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
S&F in repair 4mm dia galvanised iron or steel wire earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed.
M&L for Air termination, single pointed aluminium rod 12mm dia and 300mm long fix to aluminium strip, nut, bolts and washers including taking down existing air termination complete all as specified & as directed.
S&F in repair porcelain insulator of overall minimum size 72mm x 32mm x 34mm (single pole bus bar support insulator) suitable for fixing aluminium/GI strip roof/down conductors, fixed in PCC blocks/walls/pole/pipe with two Nos hexagonal head GI screws 40mm long, one No. hexagonal head GI bolt 30mm long & 5-6mm dia with one No. square shaped GI washer of size 25x25mm & 0.6-0.8mm thickness & one No. GI nut for fixing/running the roof/down conductors, conforming to the sample kept in GE’s office, complete all as specified & as directed. Note : Cost of screws, bolt, washer & nut is included in quoted rates.
S&F in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screws, enclosed in suitable PVC box, complete all as specified & as directed.
S&F in repairs PVC square block of size 100 X 100mm and 50mm deep with & including laminated sheet top cover fixed with cadmium plated screws for mounting switches, sockets, fan regulator etc. complete all as directed.
S&F in repairs PVC rectangular block of size 175 X 100mm and 50mm deep with & including laminated sheet top cover fixed with cadmium plated screws for mounting switches, sockets, fan regulator etc. complete all as directed.
S&F in repairs PVC rectangular block of size 200 X 150mm and 50mm deep with & including laminated sheet top cover fixed with cadmium plated screws for mounting switches, sockets, fan regulator etc. complete all as directed.
S&F in repairs PVC square box of size not less than 70 X 70mm fixed with suitable size screws to wall/ceiling etc to fix batten type light fittings over it complete all as directed.
S&F in repairs electronic driver suitable for LED security light fittings of 25 to 45 Watt 240V AC rating complete all as directed. Make: Philips/ Osram/ Jaquar/ C&S/ Bajaj/ GE / existing make as approved by GE.
S&F in repairs electronic driver suitable for LED 2x2 ft Panel light fitting of 36/ 40W 240V AC rating complete all as directed. Make: Philips/ Osram/ Jaquar/ C&S/ Bajaj/ GE / existing make as approved by GE.
S&F in repairs electronic driver suitable for LED 1x4 ft Panel light fitting of 42/ 45 W 240V AC rating complete all as directed. Make: Philips/ Osram/ Jaquar/ C&S/ Bajaj/ GE / existing make as approved by GE.
S&F in repairs suitable size PVC/ Fiber electric meter box with viewing window/ glass for meter reading for equiped existing electric meter single phase including all required mounting arrangement on wall/ panel complete all as directed by Engineer-in-Charge.
fakhrie apostrical (BID ID -3081292)
J J ENTERPRISE (BID ID -3084703)
BHAVNA IMPERIAL ENTERPRISE (BID ID -3085333)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .