Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC 103 DIAMOND PLAZA B H NILAM SHOPPING CENTRE DIAMOND STREET BOTAD GUJARAT 364710 | BOTAD | GUJARAT | 364710 | ₹2.9 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹3.1 Cr+₹19.2 L (6.67%)Rejected-Finance | ₹3.1 Cr+₹19.2 L (6.67%) | L2 | Rejected-Finance Second Lowest Bidder |
Tender Value
₹3.3 Cr
EMD Value
₹8.3 L
Closing Date
29 May 2025, 5:30 pmClosed
Registrar
RRU Campus, Lavad, Gandhinagar
Supply, Installation, Testing and Commissioning of Substation at RRU Campus at Lavad Gandhinagar
2025_RRU_861319_1
RRU/CDFM/ SUBSTATION /25-26/05
Open Tender
Electrical Works
Item Rate
RRU Campus, Lavad
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,900
Yes
Registrar, Rashtriya Raksha University
₹8.3 L
Yes
24 Jul 2025
23 May 2025
2 Jun 2025
23 May 2025
29 May 2025
23 May 2025
Amount
NEW SUBSTATION
HYDRAULIC CRANE: Maniar make Hydraulic Access Platform (Skylift) on Tata 1112 CBC BS6 Vehicle of working height of 15 Mtrs. and weight cap. of 140 kgs as per Detail specification.
HT CABLE: Supply, Laying and commissioning of following size 11KV(E) grade XLPE insulated for cables, FR PVC outer sheathed, steel strip/ wire armored aluminum/copper conductor, underground cable. The cable shall conform to IS 7098, Part-II with latest amendments and technical specifications attached with this BOQ. 3C X 300sq.mm, AL. XLPE ARM. CABLE.
HT CABLE TERMINATION: supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 300 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 300 sq. mm
11KV HT PANEL: Providing, erecting, testing commissioning & getting Plan Approval as well as NOC from Electrical Inspector for extensible H.T panel comprising of one 630A. H.T. VCB incoming & Two outgoing 630 A Drawout type VCB confirming as per I.S. for use on 11 KV, 3 phase, 50 c/s. unearthed A.C. supply system having breaking rupturing capacity of 350 MVA complete with spring operated mechanism, mechanically & automatic ON-OFF and spring mechanism charged, discharged indicators, ON-OFF mechanical push button, operation counter necessary auxiliary switches, closing shunt trip, air insulated busbar chamber having heat shrinkable PVC sleeves, mechanical interlocks safety shutters, isolating plugs and a VCB trolley with three vacuum interrupters with epoxy support insulators and self aligning finger type isolating contacts. The breaker shall be Manual cum motorised mechanism & auto spring charge with TNC switch closing with following accessories. 1. flush mounting type digital multifunctional meter with communication facility - Three sets., 2. Power Factor Meter One No, 3. Double core current transformer cast resin type having ratio 200 to 50/1 core for metering & second core for protection having required class of accuracy. - Three Sets , 4. Instantaneous under voltage relay& Temperature rise Tripping Relay, 5. Electrical closing coil & short trip coil operating on 110V. D.C.- Three Sets , 6. Auxiliary relay for anti pumping device, 7. Three phase Three limb Drawout type feeder connected & output of 200 VA cast resin insulated potential transformer having ratio 12000V./110V. and 200 VA Burdon with 0.5 accuracy. - One No., 8. Common Alarm bell operating on 110V A.C.- One No. , 9. Digital KWH Meter - One No. , 10. Cable boxes suitable up to 11 KV 3core 150 sq.mm XLPE cable. - Three Nos., 11. 230V. A.C. to 110V. D.C. power pack for closing & tripping circuit common., 12.Breaker ON-OFF, Auto trip and spring charged indicators. - Three Sets., 13.Phase indicating & panel illumination lamps with plug socket - Three Sets., 14.Numerical Communicable type non directional O/C & E/F Relay with a setting of 5-250% both in O/C & E/F. -Three Set. complete with necessary interconnection with air insulated high grade copper busbar {Breaker Testing scope include Closing Time, Opening Time, VCB Hi-Pot test at Site}{ Relay Testing Scope Include testing of all protection by three phase testing kit at site }(VCB Trolley is to be provided), Following test are to be conducted at site during conmmissioning before charging of vcb panel. 1) IR value, 2) Checking of mechanical and electrical operation and control circuit, 3) Testing of CT and relay with primary injection., 4) Setting of relay as per the site requirement., 5) Testing of transformer auxiliary relays.
Transformer & Accessories.: Providing, erecting, testing & commissioning approved make oil immersed ONAN cooled, double wound, core type indoor / outdoor copper wound 11KV/ 433V step down transformer of following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full temperature rise in oil not exceeding 45 Deg.C.at maximum ambient temp. of 50 Deg. C. complete with necessary radiator first filling of new transformer oil & standard fitting as below complying with IS 1180( Part 1 ):2014 standards with energy efficiency level 2. ON load tap changing range steps +5% to -5% on H.V for variation should be provided. The H.V. shall be connected Delta & Secondary with star connection. The transformer should have cable-end boxes on H.T. side suitable for up to 3 core 150 sq.mm. XLPE cable & on L.T. side suitable for bus duct or cables as per requirement complete with test certificates from manufacturers , 1. Oil conservator with filling Hole & Cap - One No., 2. Thermometer pocket with 6" dial type thermometer switch alarm & trip contacts- Two nos., 3. Silica-gel breather with charge- One No., 4. Plain oil level gauge - One No., 5. Drain / Sampling / Filter valve- One No., 6. Top Filter Valve - One No., 7. Explosion vent with Diaphragm - One No., 8. Rating & Diagram plate - One No., 9. Additional neutral bushing for earthing - One No., 10. Bi directional Roller - Four Nos., 11. Earthing terminals - Two Nos., 12. Lifting lugs - Two Nos., 13. Air release plug. - One No., 14. Double float buchholz relay with Alarm and trip contacts., 15. Control cable as required from Transformer to VCB Panel is to be provided with necessary connection to VCB relays for protection., as per IS 1180 level-1, (c) 750 KVA , Max. allowable loses Shall be as per IS 1180 - Level-1, Following test are to be conducted at site during commissioning before charging of transformer. 1) IR value of transformer (HV-E, LV-E), 2) Turn ratio test on all tap positions, 3) Magnetic balance test., 4) Conformation of vector group., 5) Checking of electrical and mechanical operation OLTC and RTCC and control circuits for local and remote., 6) Testing of transformer oil (BDV test) and filling of oil., 7) Checking of tranformer auxiliary realy, buchlz, wti and oti, mog, osr.(With setting of WTI and OTI), 8) Checking for oil leakage.
Supply Installation Testing Commissioning of Package Substation : 11KV Compact switchgear consisting of 630A one number of Fixed manual SF6 insulated Vacuum circuit breaker. SF6 insulated Vacuum circuit breakers with self- powered relay having Transformer protection, over current and earth fault protection. Interconnection between VCB and transformer shall be by using suitable Copper unarmoured 11KV (UE) 1CX1RX300 sq.mm per phase cable which is in the scope of Bidder. Outdoor type enclosure having modular construction of Galvanized Sheet Steel. The degree of protection for HT & LT switchgear compartment shall be IP55 & degree of protection of transformer compartment of the enclosure shall be minimum IP23. Painting of the enclosure exterior shall be suitable for sea shore conditions. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door-operated switch shall be provided for each compartment. Structure of the substation shall be able to withstand the gross weight of all equipment. It should be possible to transport the equipment along with transformer, RMU & LT Panel from one site to another. Interconnection between HT switchgear & Transformer using XLPE cable & Interconnection between Transformer & LT switchgear using high conductivity Aluminium busbars(E91E) . Internal earthing connections by GI strips. DC supply for PSS shall be through in built 24V power pack. Separate DC supply shall be not provided for auxiliary power requirement purpose. 1) SF6 Insulated VCB shall be 630A - 21KA/3 secs with all Numerical Relays and Indication Meter complete. 2) Transformer :- 3 phase 50 Hz 500KVA , 11KV /433V, DYn11, core type double wound with copper conductor oil immersed ONAN cooled Distribution Transformer hermatically sealed corrugated tank arrangement having a no load voltage ratio of 11KV/433V with top HT & LT Bushings. Tappings +5% to –5% in steps of 1.25% shall be provided at line end of HV winding. Changing of taps shall be carried out by means On load tap changing. Max. allow losses shall be as per IS 1180 : 2014 Part-I (Level-I)., Impedance & Tolerance shall be as per IS 1180 : 2014 Part-I (Level-I), Shall be with WTI, OTI monitoring equipments as per data sheet 3) Busbar : LT Switchgear 433V LT Switchgear with 800A TPN,25KA Aluminium busbars. Interconnection between Transformer and LT Switchgear shall be using Aluminium Busbar. , 4). Switchgear : Incoming : 800A FP 35KA Manually Fixed Type ACB Microprocessor Based release for O/L S/C E/F protection with Digital Multifunction Meter. 4) Enclosure : Outdoor Enclosure Outdoor type enclosure having modular construction of Galvanised Sheet Steel in corrugated type wall design for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. 5). Interconnection LT Cable suitable for 3 nos of 3.5C x 300Sqmm AL XLPE Armoured Cable, bus terminal and required accessories with Angle Support, Rack etc. complete as per Single Line Diagram & Technical Specification.
LT Panels: Supply, Installation, Testing & Commissioning of Main LT Panel as per SLD & Specification. , Incomer : 800Amp, 4P, 50KA Microprocessor based Electrical Draw Out ACB, LSIG Protection : 2 Nos, Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram., Mechanical Electrical Interlocking between Incomers., Busbar Chamber : 1000Amp, 4P, Aluminium Busbar, 50KA., Outgoing : 400Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 4 Nos, 250Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 4 Nos, 125Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 4 Nos, 100Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 4 Nos, 63Amp, 4P, 25KA MCCB - 4 Nos, Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram., 15KVAR Fixed Capacitor Bank for Transformer as per SLD., SPD as per SLD.
Supply, Installation, Testing & Commissioning of Main LT Panel as per SLD & Specification. , Incomer : 1250Amp, 4P, 50KA Microprocessor based Electrical Draw Out ACB, LSIG Protection : 2 Nos, Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram., Mechanical Electrical Interlocking between Incomers., Busbar Chamber : 1500Amp, 4P, Aluminium Busbar, 50KA. Outgoing : 630Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 2 Nos, 400Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 2 Nos, 250Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 4 Nos, 125Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 4 Nos, 100Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 4 Nos, 63Amp, 4P, 25KA MCCB - 4 Nos, Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram., 20KVAR Fixed Capacitor Bank for Transformer as per SLD., SPD as per SLD., Input Terminal for Transformer RTCC Panel.
Design, Supplying, installing, testing of factory fabricated ready made Three phase APFCR Panel Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2 Capacitor Duty Contactor for switching as per following Steps Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection,Copper tinned insulated Busbar,Cubical panel should be indoor type with IP 43 and IK 10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor for each capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor having suitable MCB with Sc, OL, internal earth fault relay,Each stage having Stage Contactor (Capacitor load rating),PF regulator master controller having suitable steps with LCD display, Rs 485 Communication port, Indication LED Lamps for main incomer and ON-OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as per site situation,Cooling fans for panel 210 KVAR Capacitor Panel as per SLD & Specification. (100 KVAR - 1 Nos + 50 KVAR - 2 Nos + 25 KVAR - 2 Nos + 10 KVAR - 1 Nos) as per SLD & Specification.
Design, Supplying, installing, testing of factory fabricated ready made Three phase APFCR Panel Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2 Capacitor Duty Contactor for switching as per following Steps Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection,Copper tinned insulated Busbar,Cubical panel should be indoor type with IP 43 and IK 10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor for each capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor having suitable MCB with Sc, OL, internal earth fault relay,Each stage having Stage Contactor (Capacitor load rating),PF regulator master controller having suitable steps with LCD display, Rs 485 Communication port, Indication LED Lamps for main incomer and ON-OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as per site situation,Cooling fans for panel 210 KVAR Capacitor Panel as per SLD & Specification. (100 KVAR - 1 Nos + 50 KVAR - 2 Nos + 25 KVAR - 4 Nos + 10 KVAR - 1 Nos) as per SLD & Specification.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.: 25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board ofsheet steel, dust protected, duly powder painted, inclusive of200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 900 mm width X 75 mm depth X 2.0 mm thickness
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover.(approved make OEM has to submit test certificate including value of earth resistane of installation.)independent Earthing located in other than normal soil i.e. Soft Rock, Marshy Soil etc..-Length of Pipe : 3 Mtrs. -Back filling Compound :2 nos Bags of 25 Kg.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 50 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (B) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core)
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
(I) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core)
(J) 3 1/2 core 300 Sq.mm ( 150 Sq. mm 1/2 core)
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (A) 4 core 16 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (G) 12 core 2.5 sq.mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (A) 4 core 10 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (B) 4 core 16 Sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 240 sq. mm (62mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm (70mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 12 core 2.5 sq.mm
Supplying & erecting approved make low noise decorative exhaust fan having square frame ABS body with inbuilt lowers & square frame.250mm with 1350 RPM Cat.II
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan box.
Providing Fan clamp of 30 x 5 mm flat of required length & 10 mm M.S. Bolt & Nuts erected with necessary hook of 10 mm M.S. Round Bar.
Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the RCC bars up to 50mm length each side and pierced through a 16 Gauge M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with necessary finishing.
Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50" diagonally size.
Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply.
Supplying rubber matting of following thickness as per IS:15652/IEC 61111 (c)12mm
Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)
Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and Red out side with FIRE mark, filled with dry-sand and kept on existing stand provided or hung on wall hook.
Supplying and erecting floor mounting stand for keeping four nos. of FIRE buckets comprising 1500 mm in length, 900 mm height frame made out of 30mm X30 mm X 4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of approved enamelled silver paint.
Wall hook 22 to 25 cms. projection for keeping fire buckets made out of 15 mm dia. M.S rod grouted in wall to a depth of minimum 15 cms.
Supplying & erecting D.C.P. type fire extinguisher for following capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets confirming to IS 2171 1985 and complete erected with necessary clamps made from 50 x 6 mm M S Flat with nuts and bolts grouted in wall complete. [A] For 5 Kg Capacity
Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete. [B] For 5.5 / 6.5 KG Capacity
Supplying & erecting ABC powder type 'Ceasefire' type Fire extinguisher as per IS 13849 or 1 Kg capacity with necessary clamp for erection on wall
Supplying & Fixing SMC Chequered plate having 12 mm thickness, made out of SMC Confirming to IS 13410 & by Hot press Compression Moulding technique Suitable cut & fixed with MS Angle Frame to Fit Trench Widths as per site requirement approved .by engineer incharge
Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth for laying any size of cable or locating the fault all over the run and back filling the same and making the surface as normal ground.
Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cm. layer of sand above & below cable (16 bricks per meter)
Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original. (C) 300 mm dia
Supply and installtion of expanding firestop foam equivalent to Hilti CP 620 on both sides of wall, with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814, for horizontal openings in floors or slabs made of concrete/ masonry or Gypsum after passing service lines like cable trays or cables/cable bundles. The expanding foam expands seven times its volume to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after dispensing. The product shall be age tested as per Dafstb and DIBT standards. The product shall provide water tightness when tested for W rating as per UL standards and shall carry test certificate for sound insualtion of 50 db when tested in accordance with ASTM E 90. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1.3 g/l as per LEED 2009. The product shall be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The system shall be UL listed & classified. The system shall be UL & FM approved.
Supply and installation of Fire stop mortar system equivalent to Hilti CP 636 , with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814 standards, for horizontal openings in floors or slabs after passing service lines like cables/cable bundles, cable trays etc. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be age tested as per Dafstb and DIBT standards.The system shall be UL listed. The gaps around inaccessible or complicated openings shall be sealed with exapnding firestop foam.
Supply and installatio of Acrylic Firestop Sealant equivalent to Hilti CP 606 in gaps between wall and slab made of concrete/masonary/gypsum on both sides of wall to provide minimum 2 hours fire rating when subject to the test conditions of UL 2079 standards. The product shall be age tested as per DafStb guidelines. The product shall be age tested as per Dafstb and DIBT standards.Sealant should provide sufficient MAF, water and gas tight seal. Sealant shall also provide airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation. Sealant shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4.
kWh LCD meter Cl 1 with RS485
DIN type 1P Energy Meter with RS 485 Port
DIN type 3P Energy Meter with RS 485 Port
SmartComm EMS 150 meters
1 /port RS485 Serial to Modbus TCP/IP Communication Gateway
Ethernet Switch 8 Port
Meter Installation Charges
SmartComm EMS Installation & Integration Charges
Shielded data cable, copper with low impedance, 0.5mm capable to transmit the data of energy meter's serial port RS485
CAT - 6 Data Cable (Patch cord)
WebView (Web Browser Based Monitoring)
Three Year 25,000 SMS Package
Rate Only Items
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2 way 5/6A Switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 4 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 8 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 12 Module
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 600 mm width X 50 mm depth X 2.0 mm thickness
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (A) 4 core 10 Sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 sq. mm (28mm)
Supplying & erecting D.C.P. type fire extinguisher for following capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets confirming to IS 2171 1985 and complete erected with necessary clamps made from 50 x 6 mm M S Flat with nuts and bolts grouted in wall complete. [B] For 10 KG Capacity
Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete. [A] For 4.5 Kg Capacity
Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original. (A) 450 mm dia
Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original. (B) 400 mm dia
Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original. (D) 250 mm dia
Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original. (E)150 mm dia
Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original. (F) 100 mm dia.
BUYBACK ITEM: Buyback of Existing installed 3 way HT Breaker Panel as per Site. one 630A. H.T. VCB incoming & Two outgoing 630 A Drawout type VCB complete with dismantelling the same from site.
M/S PATEL NAVINCHANDRA MAGANBHAI (BID ID -3221498)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .