Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 CrAccepted-AOC | ₹33.0 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹33.5 CrRejected-Finance 216 C SIVA COLONY MAYO LINK ROAD AJMER RAJASTHAN 305007 | AJMER | RAJASTHAN | 305007 | ₹33.5 Cr | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹33.6 CrRejected-Finance 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹33.6 Cr | L3 | Rejected-Finance Rejected being L3 |
| 4 | L4₹36.7 CrRejected-Finance | ₹36.7 Cr | L4 | Rejected-Finance Rejected being L4 |
| 5 | L5₹36.8 CrRejected-Finance | ₹36.8 Cr | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹34.1 Cr
EMD Value
₹15 L
Closing Date
15 Jul 2020, 6:00 pmClosed
CE NW Kochi
Kattaribagh, Naval Base, 682004
PROVISION OF DEFICIENT MARRIED ACCOMMODATION FOR OFFICERS AT INS DRONACHARYA KOCHI
2020_MES_343985_1
890924
Open Tender
Civil Works
900 days
Fort Kochi
As per NIT
8 documents required · 8 mandatory
₹3,000
GE Fort Kochi
₹15 L
Yes
3 Nov 2020
11 May 2020
18 Jul 2020
12 May 2020
15 Jul 2020
8 Jul 2020
12 May 2020 - 25 May 2020
Amount
LIST OF WORKS
Schedule A Part I( to Part XIII)
Total amount of Sch 'A' Part-I (Buildings & Structures)
Total amount of Sch 'A' Part-II ( Excavation, Earth work and Site clearence)
Total amount of Sch 'A' Part-III (Internal Electric Supply)
Total amount of Sch 'A' Part-IV (Internal Water Supply)
Total amount of Sch 'A' Part-V (Road/Path/Hardstanding)
Total amount of Sch 'A' Part-VI(Sewage Disposal)
Total amount of Sch 'A' part-VII (Area Drainage)
Total amount of Sch 'A' part-VIII (Retaining Wall)
Total amount of Sch 'A' part-IX (External Electric Supply)
Total amount of Sch 'A' part-X (Externall Water Supply)
Total amount of Sch 'A' part-XI ( Lightning Protection)
Total amount of Sch 'A' part-XII(Fire Fighting)
Sch 'A' Part- XIII (MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Boring for cast-in-situ bored piles of 700mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ bored piles of 900mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
RCC with ready mix concrete(RMC) M30 grade in cast in situ bored pile with minimum cement content 400kg/cum of any length/any sections complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV. Note:-(i) Reinforcement will be measured and paid separately under relevant items
RCC with ready mix concrete(RMC) M30 grade in pile cap , grade beam & tie beam complete all as specified and shown on drg. Note:-(i) Reinforcement will be measured and paid separately under relevant items
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for grade beam/tie beams and pile caps of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5mm dia and over up to and including 12mm dia as in stirups for pile caps and grade beams including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
All as per item No 22 above but 5mm dia and over up to & including 12 mm dia as in helicals of pile reinforcement including rings and necessary tack welding to pile reinforcement at all points of contacts.
PCC (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile caps/grade beams and foundation complete all as specified and shown on drgs.
Providing testing equipment & load and testing of 700mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 900mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed..
Providing testing equipment & load and testing of 700mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 900mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep or area not exceeding 10 sqm on plan in soft/loose soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/plinth beams,raft foundation etc all as specified and shown on drawings.
Excavation over areas n exc 1.5m deep in soft / soil complete all as specified and directed.
Excavation over areas exc 1.5m n exc 3m deep in soft / soil complete all as specified and directed.
Returning filling in around pile cap, plinth beams, raft foundation etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus soil to a distance not exceeding 50m deposited whereever dircted at a level not exc 1.5 m above starting point .
Formwork to sides of pile caps , grade beams rough finished surface of concrete flat all as specified .
Conducting standard penetration test(SPT)all as per IS 2131 at levels and locations as directed for bored pile of any dia.
INTERNAL ELECTRIFICATION:
Supply and fix Ceiling fan 1200mm sweep copper wound having minimum Air delivery 210(m3/min)and minimum service value4(m3/min/w) , including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sqmm from ceiling rose/ connector to fan all as specified and as directed by the engineer-in-Charge. (Make :CG/USHA/HAVELLS)
Supply and fix air freshner of size sweep 250mm, speed 1250RPM 230V, 50Hz and Air delivery 720 cubic meter per hour complete with bird proof grills louvers etc of make Crompton Greaves Mod BRISK Air or equivalent in Bajaj/Havells.
Supply and fix LED Tube light 1X22 Watt universal battern type with and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor color of sleeve matching to fitting and connecting frpm ceiling rose to fitting. complete all as specified and as directed by the engineer-in-Charge. Make:- (a) Fitting: Havells Cat Part No REGALBATTERN8UPTOP1X22WWSSBSWH or equivalent make of CG/Philips. (b) Lamp: Havells Cat Part No CRYSTAL1213T8DSTL20LED865SGLASS or equivalent make of CG/Philips.
Supply and fix Sleek LED light 1X10 Watt 2 feet with and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor color of sleeve matching to fitting and connecting frpm ceiling rose to fitting complete all as specified and as directed by the engineer-in-Charge. Make: Fitting WITH LAMP: Havells Cat Part No LUMILINEPLUSBS10WLED865SPCSS or equivalent make of CG/Philips.
Supply and fix Sleek LED mirror light 1X10 Watt with and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor color of sleeve matching to fitting and connecting from ceiling rose to fittingcomplete all as specified and as directed by the engineer-in-Charge. Make:-Fitting WITH LAMP: Havells Cat Part No LUMILINEPLUSNSI0WLED865SPCSS or equivalent make of CG/Philips.
Supply and fix Decorative wall light fitting with and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor color of sleeve matching to fitting and connecting from ceiling rose to fitting copmplete all as specified and directed at site Make: (a) Fitting : Havells Cat Part No LHFHCHEITLIW020 or equivalent make of CG/Philips. (b) Lamp: Havells Cat Part No LHLDEUHEML8R009 or equivalent make of CG/Philips.
Supply and fix Street light new generation energy saving and environmental friendly long life LED street light made of pressure die cast alluminium housing with high power LED as lighting source and lens embded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK 07 complete with and including wall mounted bracket fabricated out of 40mm GI pipe light grade bend to shape1.5 mtr long and two nos wall mounting clamps using 25x4mm thick MS strip bend to shape and welded with pipe to form solid structure and one run of 1.5Sqmm PVC insulated multistranded copper conductor wire conecting pvc terminal/ Ceiling rose up to fitting. (Make Havells 25W LED IP66 security light Model No.ENDURAPEARL25WLED757SASYTOPCor equivalent make of CG/Philips).
Supply and fix Vertical DB RCBO incommer 4 pole 40 Amps 7.5 sensitivity 100 mA module and and MCB SP 24 Way (MCCB 40AP +8+8+8) double door 240 Volts with 200 Ampsrated bus bar complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN 40-63 Amps 10 kA with chareterestic "C" Curve all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN 6-32 Amps 10 kA with chareterestic "C" Curve all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SP 6-32 Amps 10 kA with chareterestic "C" Curve all as specified and as directed by the Engineer-in-Charge.
Supply and fix modular Socket 16 Amps with and including modular mini MCB with and including modular GI terminal box and modular base plate and cover of matching colur with wall and other switches complete of make Crabtree model No ACAKCXW163 for socket outlet 16 Amps, model No DCANCSPA020 for mini MCB 20A, Model No ACAPLCSV08 for modular baseplate and cover and model No ACTXMIIX08 for modular sheet terminal block. Complete all as specified and directed by E-In-Charge for A/C andd geysers
Supply and fix Modular switch 1 way 16 A with indicator, 2 module 230 Volts,50Hz, ISI marked with valid CML No with and inclusive of Modular base plate and its cover and modular terminal box as in master switch for geyser to be fitted outside bath room all as specified and as directed by the Engineer-in-Charge.
Supply and fix Single phase tamper proof KWH meter with and including MS enclosure duly fabricated out of MS sheet 1.2mm thick with glass window to read parameter of KWH meter ISI marked complete all as specified and directed at site.
Supply and fix Exhaust fan heavy duty single phase AC 230V,300mm sweep 6 pole 950RPM 1145 cubic metre per hour air delivery complete with bird proof mesh and louvers of make Crompton model No EXHO300-6-1 or equivalent in Bajaj/Havells/usha .
Supply and fix GI metal flush boxes 2 module of make Legrand cat Part No 689007 all as specified and as directed by the Engineer-in-Charge.
Supply and fix RJ 11 telephone socket 1 module of make Legrand cat part No 675541 with cover plate all as specified and as directed by the Engineer-in-Charge.
Supply and lay concealed non metallic rigid PVC conduit all as specified and as directed by the Engineer-in-Charge.
Supply and fix TV socket 1 module of make Legrand Cat part No 675546 with cover plate all as specified and as directed by the Engineer-in-Charge.
Material and labour for 15cm thick (compacted thickness) WMM,with coarse aggregates of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size),spread ,rolled and consolidated to gradient and camber required using granite,trap or basalt complete all as specified and as directed by the Engineer-in-Charge.
SEWAGE DISPOSAL:-Supply and lay DWCPE (SN8) 180 mm dia pipes laid and jointed complete with collars etc all as specified and as directed by the engineer-in-Charge.
Material and labour for Preparation of new surfaces steel exceeding 10cm width or girth and applying two coats anticorrosive paint over a coat of anti corrosive primer all as specified and as directed by the engineer-in-Charge.
Internal Water Supply :- Supply and fix Stop cock 25mm bore with wall flange ceramic disc cartridge with plain knob complete of make Jaquar cat part No CQT-24081 all as specified and as directed by the Engineer-in-Charge.
Supply and fix Stop cock angular 15mm bore with wall flange complete of make Jaquar Cat part No CQT-23059 all as specified and as directed by the Engineer-in-Charge.
Supply and fix Bip tap with wall flange complete of make Jaquar Cat part No CQT-23047 all as specified and as directed by the Engineer-in-Charge.
Supply and fix Stop cock long body combination of exposed part kit of consealed stop cock with fitting sleave, operating knob, adjustable wall flange and regular body consealed stop cock suitable for 15mm pipe line with protection cap. Complete of make Jaquar cat part No CQT-23082K and ALD083 all as specified and as directed by the Engineer-in-Charge.
Supply and fix Hot water braided pipe 450mm long with two 15mm nuts and rubber washer without nipple, Complete of make Jaquar cat part No ALD805B all as specified and as directed by the Engineer-in-Charge.
Supply and fix Health faucet/ hand shower with 8 mm dia, wall hook and easy flexible tube in crome finish1.5m long with nuts complete of make Jaquar cat part No ALD573 all as specified and as directed by the Engineer-in-Charge.
Supply and fix Over head shower rose 100mm dia round shape single flow ABS body chrome plated wirh grey face plate and Rubi/ cleaning system and shower arm casted120mmlongheavy body round shape for wall mounted shower with wall flange complete of make Jaquar cat part No OHS1989 and SHA-487 all as specified and as directed by the Engineer-in-Charge.
Supply and fix Central hole basin mixer without popup waste system with 450mm long bradied hose with all acessories complete of make jaquar Cat part No CQT 23167B all as specified and as directed by the Engineer-in-Charge.
Supply and fix wall mixer with connecter for hand shower arrangement with connecting legs wall flanges & wall brackets, hand shower with all acessories complete all as specified and as directed by the Engineer-in-Charge.Make Jaquar Cat part No .Wall mixer : CQT 23267 Hand hower: HSH 1717 Flexible pipe : SHA 571
Supply and fix Storage water heater 15ltr capacity vertical type complete of make havells model No Monza EC GHWAMFSWH015 WHITE with and including connecting all fitting and Fixture uch a mounting brackets, vent pipe, inlet and outlets etc complete all as specified and as directed by the Engineer-in-Charge.
External Electric Supply:- Supply, laying , jointing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 400 Sqmm complete with cable glands and cable lugs all as specified and as directed by the Engineer-in-Charge.
All as per Item No 70 herein before but 3.5 core 300 Sqmm.
All as per Item No 70 herein before but 3.5 core 185 Sqmm
All as per Item No 70 herein before but 3.5 core 35 Sqmm
All as per Item No 70 herein before but 4 core 25 Sqmm
All as per Item No 70 herein before but 2 core 16 Sqmm
All as per Item No 70 herein before but 2 core 10 Sqmm
All as per Item No 70 herein before but 2 core 6 Sqmm
Supply, spreading and levelling riddled soil as earth cushioning to UG cable by using IS seive to seperate the composite/roots etc and refilling spreading in trenches as cushioning and rammed down to form a solid bed all as specified and directed at site. Note:- Punned thickness shall be measured and paid.
Supply and fix MCCB 415 Volts, 630 Amp rating, 4 thermal magnetic release (Service Breaking Capacity 50 KA 1 No. with and steel enclosure fabricated out of 2 mm thick CRCA sheet enclosure complete with and including alteration in existing panel for extention of outgoing complete all as specified and as directed by the Engineer-in-Charge.
Supply, install, testing and commissioning of factory made and CPRI approved out door type feeder pllar box suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on alluminium bus bar of rating 1200 Amps for phases and 600 Amps for neutral fixed on epoxy insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and rear centre opening on hinges and multilayer chamber for all switches with adequate space all around accessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved alluminium strips of appropriate size as per standard is practices and comprising of followings acessorties. Note:- Rate is inclusive of necessary PCC foundation for errection of panel
INCOMINGS (a) MCCB 415 Volts, 630 Amp rating, 4 P thermal magnetic release (Service Breaking Capacity 50 KA 1 No.(b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-600 Amps with and including CTs OUTGOING (d) MCCB 415 Volts,300 Amp , rating 4 Pole , Thermal Magnetic release (Service Breaking Capacity 40 KA)- 01 Nos (For propoed building).(e) MCCB 415 Volts,400 Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 36 KA 1 No.) (f) MCCB 415 Volts,160 Amp , rating 4 Pole , Thermal Magnetic release (Service Breaking Capacity 18 KA)- 01 Nos (For up comming STP) (g) MCCB 415 Volts,40 Amp , rating 4 Pole , Thermal Magnetic release (Service Breaking Capacity 18 KA)- 01 Nos (For spare) (h) Internal wiring of panel with stranded copper cable of suitable size (j)Neon phase indicating lamp(Set of three)-01 Set (k)Stenceling of pannel board including marking of distribuitions
Supply, install, testing and commissioning of factory made and CPRI tested out door type feeder pllar box suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on alluminium bus bar of rating 600 Amps for phases and 300 Amps for neutral fixed on Epoxy insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.15mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and rear centre opening on hinge complete with multilayer chamber to accommodate such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessories.Note:- Rate is inclusive of necessary PCC foundation for errection of feeder pillar box.
INCOMINGS:- (a) MCCB 415 Volts,300 Amp rating, 4 Pole Thermal Magnetic release (Service Breaking Capacity 40 KA 1 No.)( b) Digital volt meter 0-500 Volts-01 (c)Digital Ampere meter 0-300 Amps with and including CTs OUTGOING:- (d)MCCB 415 Volts,250 Amp , rating 4 Pole , Thermal Magnetic release (Service Breaking Capacity 25 KA)- 01 Nos (For Fire fighting) (e)MCCB 415 Volts,40 Amp , rating 4 Pole , Thermal Magnetic release (Service Breaking Capacity 18 KA)- 04 Nos (For 2 Nos for lift and 01 No water supply starter panel and street lightl) (f) MCB 415 Volts,20 Amp , rating 4 Pole , Thermal Magnetic release (Service Breaking Capacity 10 KA)- 01 Nos (For terrace pump and spare) (g) MCB 415 Volts,20 Amp , rating 2 Pole , Thermal Magnetic release (Service Breaking Capacity 10 KA)- 03 Nos (For pump house, stair case/ common area light) (h)MCB 415 Volts,16 Amp , rating 2 Pole , Thermal Magnetic release (Service Breaking Capacity 10 KA)- 03 Nos (For aviation light , street light and spare) (j) Internal wiring of panel with stranded copper cable of suitable size(k)Neon phase indicating lamp(Set of three)-01 Set(l)tenceling of pannel board including marking of distribuitions
Supply and fix Analog Time lite 16 A 3 pole /230 volt analog time switch of make Indo asian cat part No TL016ABO all as specified and as directed by the engineer-in-Charge.
Supply, install, testing and commissioning of factory made and CPRI tested in door type feeder pllar box suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on alluminium bus bar of rating 200 Amps for phases and 100 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessories. ( Location LTP No 3 of schematic plan)
INCOMINGS (a)MCCB 415 Volts,40 Amp rating, 4 Pole Thermal Magnetic release (Service Breaking Capacity 18 KA 1 No.)(b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-100 Amps with and including CTs OUTGOING (d) MCB 415 Volts, 32 Amp , rating 4 Pole , Thermal Magnetic release (Service Breaking Capacity 10 KA)- 02 Nos (For starters 15 HP for pumps for water supply) (e) Star delta starter complete with single phase preventing relay and, over load and under load relay for motor protction-02 Nos) (f) Internal wiring of panel with stranded copper cable of suitable size (g) Neon phase indicating lamp(Set of three)-01 Set (h) Internal wiring of panel with stranded copper cable of suitable size (j)Stenceling of pannel board including marking of distribuitions
Supply and fix Prestressed concrete poles of 9 meter long having 152 mm x 152 mm at top and 152 mm x 260 mm at bottom all as specified and as directed by the Engineer-in-Charge.
Supply and fix aesthatically desingned road way luminarie with excelent theramal management LED street light fitting of make crompton greaves at part no LSTP-60-CDL or equivalent of philips/ Bajaj/ havells and connecting it to pole mounting box using one run of 3 core pvc insulated 1.5 sqmm from fitting to MCB in pole mounting SMC Box of size 240x130x110mm througn regid heavy duty PVC conduit duly supported with MS brackets bend to shape using 25 x 4mm thick in two halves (5 pairs) along the pole at equal interval with and including GI pipe 1.5m long bend to shape and two sets of MS flats 50 x 6mm bend to shapes in two halves with sufficient holes for fastening using nuts and bolts and painting two coats of epoxy paint over a coat of zink primer complete all as specified and as directed by the Engineer-in-Charge.
External Water Supply:-Supplying ,laying , jointing, testing and commisioning of DI pipes confirming to IS 8329 with spigot/ socket joints centrifugally cast class K-7 length laid in trenches/ walls including along with one set rubber gasket for joining each length of pipe (EPDM gasket confirming to IS 5382/ 1985) and connecting up of DI pipe size 150mm (6") dia size complete all as specified and as directed by Engr-In-Charge.
Supplying alaying jointing testing and commisioning of DI pipes confirming to IS 8329 with spigot/ socket joints centrifugally cast class K-9 length laid in trenches/ walls including along with one set rubber gasket for joining each length of pipe (EPDM gasket confirming to IS 5382/ 1985) and connecting up of DI pipe size 150mm (6") dia size complete all as specifired and directed by Engr-In-Charge.
Material and labour for connecting to existing CI/DI pipe line by cutting and making necessary provisions for inserting of 150 mm DI Pipeline incl testing complete as directed.
Material and labour for Masonary valve chamber, 100 mm thick foundation using PCC 1: 4: 8 , Type D-2, over 50mm thick hard core, 20 cm thick solid block masonry with blocks casting using PCC 1;3:6, type C-1, set in CM mortar 1:4, 15mm thick plaster to internal surfaces and external surfaces up to 15cm below ground level and to p of floor in in cement and sand mortor 1;4, finished even and smooth without using extra cement, 3mm thick MS sheet cover including 50mm x50mm x 6mm thick MS angle frame fixed in PCC 1;2;4, type B-1 copping with 25mm x 6mm flat angle hold fasts, handle, hinges with locking arrangements, applying two coats of synthetic enamel paint over a coat of red oxide paint and painting to cocrete surfaces and removal of surplus soil to a distance n exc 50m complete allas specified and directed of size 900x900x900 mm complete all as specified and directed
Supply, install, test and commissioning of manufacturer’s factory assembled and tested electric driven Multistage mono block centrifugal pump sets set of capable of delivering 10 LPS at 60 Meter head coupled with three phase 415 volt 3000 RPM complete of cat Part No KDT 1078 Suc. 65mmX Del 50mmof Make Kirloskar Brothers. The work also includes the followings:-
(a)M&L for Lowering of GI suction pipe flanged type heavy grade welded with flange of dia not less than the dia suitble to match the sucttion of pumps from foot valve at suction pit to pumps (b)M&L for of GI delivery pipe flanged type heavy grade welded with flange of dia not less than the dia suitble to match the pumps from Pump butterfly valve and from butterfly valve to NRV. (c) M&L for MS 'C' chanel for clamp made out of MS flat 100x12 mm for lowering/installation of pump set complete- 02 Nos
(d) Supplying, fixing and testing of Brass reflux valve (NRV) of suitable dia flanged joint complete with nuts, bolts and washers complete all as specified. (e) Supply and fixing of slim seal butterfly valve with iron wheel head both ends flanged for iron pipe and fixed complete with nuts, bolts and washers complete all as specified. (f) Pressure gauge diaphragm type up to 50 Kg/Cm2-1 No. (g) M&L for air release valve 15mm
Fire Fighting :- Supply and fix Automatic air release valve 50mm dia suitable with 50mm gun metal stop valve complete all as specified and as directed.
Supply and laying armoured FR cable 2 Core 1.5 Sqmm copper cable ISI marked with proper clamping, supports and terminations through metal conduit all as specified and as directed by the Engineer-in-Charge.
Design, Fabricate, Supply, Installing, Testing and Commissioning of Electricaly control panel of cubical construction, Wall mounting type, fabricated out of 2.0 mm thick CRCA sheet, with hinged lockable doors, inter connection, having switchgears and accessories mounting and internal wiring, earth terminal, numbering etc, complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply, one st of allumminium busbar having 500 A for phases and 300 amps for neurtral complete with colour code insulation mounted on epoxy insulators. (a) 250 Amps 4P MCCB 25 kA wit termal magnetic relay -01 nos (b) MCCB 150 Amps 4 pole 16 kA with termal magnetic release(out going)--02 Nos(main pump and sprinkler) (c) MCB 40 Amps 10 kA-01 No(jockey Pump) (b) Digital panel multifunction meter.-01 Nos (c) Star delta startor with auto/ manual control-02 Nos(Jockey, Main ) (d) Set of 3 phase indicating lamp.-01 Set (e) Automatic opetaion of main pump set(01 No) other than jockey pump set with in 10 seconds while jockey pump is running to meet the required pressure in main line. If the main pump set fails to start with in 10 seconds, run procedure/ program for automatic start operation of Engine driven pump sets to meet the required constant pressure from varring low pressure in main line with in 10 seconds. (f) Digital/ analog display of parameters/ status of engine as under:- (i) Low fuel( The the display should match the corresponing fuel capacityof Engine driven pump set in here in above) (ii) Over Heat. (iii) low oil pressure. etc and all standard features as per mannufacturers guide lines.
Supply and fix staircase sighnage down of make bajaj cat part No 111499 model No DSDWBB 3w double side display for staircase downwards (with 2 hours backup) complete all as specified and directed at site .
Supply and fix staircase sighnage EXITof cat part No of make bajaj cat part No 220208 model No BESL 03 LED SSDWBB Red (with 2 hours backup) complete with all accessories all as specified and directed at site.
Material and labour for SITC of repeater panel with Announciation repeaters, supply of panel with 320 Alpha numeric Characters on LCD display/ Or Touch screen LCD sitting as Network Node on the Main Network Peer-Peer Topology, shall be able to work with all functionality of Main Panel having Reset / Alarm Silence and acknowledgement Buttons. On the Active Repeater over serial inetrface or Network there shall be Announciation Panels as well for all Control station. Indivdual Active Repeater shall be able to take care of upto minimum 16 nos Annuciation LCD Panels complete with all accessories all as specified and directed.Approval Standards: Vds/EN MAKE:SIEMENS/NOTIFIER/ESSER/FIRE FINDER
Supply and fix Electric motor siren conforming to IS 1941 suitable for three phase 415 V supply with motor not exceeding 3.75 KW power and able to deliver 143 DB noise level complete as all accessories all as specified and directed.
Supply and fix DCP(ABC)type Fire Extinguisher ISI marked of 6Kgs capacity with intial charge incl bracket for installation complete as all accessories all as specified and directed.
Supply and fix Fire Extinguisher ISI marked of 4.5Kgs capacity , light weight, sqeeze grip type with intial charge incl bracket for installation complete as all accessories all as specified and directed.
Supply and fix CO2 Mechanical Foam(AFFF)type Fire Extinguisher ISI marked of 9litrs capacity with intial charge incl bracket for installation complete as all accessories all as specified and directed.
Material and labour for Ductile Iron specials for spigot/socket joints such as bends Tees, reducers collars caps etc complete as all accessories all as specified and directed.
AVIATION OBSTRUCTION LIGHT:-Supply and fix aviation obstruction light BGAV302 LED aviation light Bajaj make or equivalent in Philips/Wipro integral inside weatherproof enclosure with astronomical timer switch single module and one 10A MCB SP 230 VOLTS FIXED IN A DOUBLE DOOR WEATHER PROOF ENCLOSURE and incl making necessray connections and setting of time switch to suit local conditions. complete all as specified and directed.
STANDBY DG SET:-Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 125 KVA, water cooled, 415 Volts(AC Three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, Anti-corrosion coated exhaust pipe complete and suitable for conditions prevalent at Kochi. (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation( of suitable size leaving at least 0.6 M all around for ease of movement and 0.5 M height), all features to comply with latest CPCB guidelines and Comprising of followings:-
(i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection ,four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 125 KVA at outdoor atmospheric conditions at Fort Kochi. ,(Taking all derating factor into consideration), , 12/24 Volt(as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with techometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc .
(ii) ALTERNATOR: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 125 KVA Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine.(iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.(iv) AMF CONTROL PANEL: Factory made cubicle type floor mounted LT Panel board, indoor type made out of MS angle not less than 40X40X5 mm, and 2 mm thick MS CRCA sheet , front opening type protection class IP-54 , duly powder coated after seven tank process with electrolytic grace copper bus bar of 400 Amps capacity for four poles, with all standard switchgear and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of followings:-
(v) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002.(vi) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M. (vii) External cubicle Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set. (viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.
No human intervention,rescues during power/system failure with latest IGBT power devices,3D infra red sensor with 169 beams in full length of doors and built in floor announcing system with 03 Nos hand set one each in car, machine room and near ground floor landing door and over load indicator suitable for three phase, 415 Volts,50Hz AC supply for passenger lift including all connected civil works and 2 Nos earthing with & including the following all as specified and directed:- (a)06 Nos LED 03 watt, out of which 03 Nos of light connected to inverter supply and one cabin fan 300mm sweep in lift car (b)Mechanical guide rail in 'T' section with tougue and groove arrangement for smooth operation of car and counter weight. (c)Electric motor AC, 3 phase 415 V, 50HZ of suitable capacity including cabling with FRLS cable including necessary conduits as required.
(d)Type of operation shall be single automatic push button type. (e)Type of control-16 bit micro processor variable voltage and variable frequency (V3F) (f)Type of signal system-Hall button with digital hall position indicator digital car position indicator in acr fixtures in stainless steel face plates.(g)Minimum Size of clear entrance opening of car for passenger lift shall be as per IS with automatic center opening.(h)Minimum Size of car for passenger lift shall be as per IS.(j) Automatic rescue device battery operated to bring the car cage to the nearest floor level and auto opening for evacuvation of passengers in the event of power failure. Capacity of ARD battery should be suitable to perform minimum three rescue operation.(k)Earthing shall be connected with suitable size copper earth wire from earth plate to control panel in machine room.(l) Pit Ladder,(m) Hand rail 50mm dia SS 316 L,14 Guage and Looking mirror 5 mm thick of size 3 ftx3ft (LXB) Make : Saint Gobin/ Atul/MODi or equivalent manufactures listed in list of manufactures.
(l)RCC/PCC foundation all as specified and directed complete with nut and grouting plates etc.(m)Provision of hoist way and governors rope and governor.(n)Provision of new buffer spring as per manufacturers design(o)Provision of battery operated alarm and emergency light through inverter of suitable capacity having power pack up for a period of minimum 30 minutes.(p)Drive-Geared with machine frame fixed in the machine room.(q)Over speed governer monitors the speed and triggers safety gears etc shall be installed in the machine room. Safety Measures:(i) Overload relays (ii) Contactors and fuses.(iii) Electrical terminals high quality (iv) Limit switch with accessories on each doors/cage. (v) Gravity/counter weight limit switches for top most position. (vi) Break motor of suitable size with manned released arrangements.(vii) Phase sequence corrector.(viii) Lift shall match with the standard as specified in IS-14665, (ix) mirror polished 12mm thick black granite facing at entrance of door and at cill and at lintel level, 40cm wide all as specified and as directed. (viii) Provision of shaft wiring for light and sockes for maintenance at each landing.
All as per Item No 103 above but lift of 13 passenger (884 Kg) with a speed of 1.5 Mtr/Sec.
Supply, laying and testing cable fixed on wall/ pipe XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core on walls/floors/roof etc with suitable clamps as directed.
Supply and fix MCCB with thermal /magnetic release of 4 pole 40 Amps, 16 KA in and including sheet steel. The enclosure shall be wall mounted with and including all fixing accessories complete all as specified and directed at site.
Supply and stacking of good earth suitable for grassing free from cods, stones, roots and other unserviceable materials all as specified and as directed by the Engineer-in-Charge.
Supply and stacking of good sand suitable for grassing free from mud, organic impurities and other unserviceable materials all as specified and as directed by the Engineer-in-Charge.
Supply and stacking of organic manure suitable for grassing free from unserviceable materials all as specified and as directed by the Engineer-in-Charge.
Labour only for preparation of land by mixing, spreading and levelling of good earth sand and manure as per ratio 15:4:1 including carriage from mixing yard to place of spreading as on requirement all as specified and as directed by the Engineer-in-Charge.
Supply and planting of Mexican grass (by dibbling method @ 7.5cm apart) over prepared surface with adequately developed root after providing antitermite treatment to the prepared surface including replanting of dead grass, regular maintenance such as watering, de-weeding, mowing, rooting and manuring with organic manure and neem cake and insecticides an fungicides sprayed as and when required till the end of maintenance period of one year all as specified and as directed by the Engineer-in-Charge.
COMPREHENSIVE MAINTENANCE OF LIFT:- Comprehensive maintenance of electrically operated gearless passenger lift through OEM for 884 Kg (01 No) & 544 Kg (01 No) capacity lift- (ie total 02 Lifts ) to serve ground plus ten upper floors all as mentioned in relevent items of this BOQ complete all as specified and as directed for First year after expiry of defects liability period.
All as per Item No.112 here in before but for Second year after expiry of defects liability period.
All as per Item No.112 here in before but for Third year after expiry of defects liability period.
JAIN BUILDER
A2Z ENGINEERS AND PILE FOUNDATIONS
Rabina Enterprises Pvt Ltd
CREATIVE BUILDERS
PUSHPA INFRACON
Kool home builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid