| 1 | L1₹9.7 LAccepted-AOC E 8 14 BHUMI INDUSTRIAL PARK NEAR KALYAN BHIWANDI JUNCTION BHIWANDI THANE MAHARASHTRA 421311 | THANE | MAHARASHTRA | 421311 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹30.1 L+₹20.2 L (202.9%)Rejected-AOC NO 001 7TH FLOOR TOWER II SAKTHI TOWERS 766 ANNA SALAI CHENNAI TAMIL NADU 600002 | CHENNAI | TAMIL NADU | 600002 | L2 | Rejected-AOC second lowest | |
| 3 | Rejected-Technical 11 OKHLA INDUSTRIAL ESTATE PHASE 4 NEW DELHI 110020 | NEW DELHI | NEW DELHI | DELHI | 110020 | - | Rejected-Technical Not meeting the tender condition |
Tender Value
₹11.6 L
EMD Value
₹17,350
Closing Date
3 Aug 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer
SCADA Sub Division Poringalkuthu
Supply erection and commissioning of new vibration monitoring system for 1 x 16 MW Generator at PLBE Power house Poringalkuthu
2021_KSEB_428557_1
E/02/2021-22/AEE/SCADA/PGL
Open Tender
Electrical Works
Item Wise
60 days
Poringalkuthu
Please refer Tender documents.
9 documents required · 9 mandatory
₹5,900
₹17,350
19 Sept 2022
2 Jul 2021
5 Aug 2021
3 Jul 2021
3 Aug 2021
17 Jul 2021
180 days
Supply, erection and commissioning of new Vibration monitoring system for 1x16MW Generator at PLBE Power house Poringalkuthu - The Vibration monitoring system consists of the following items:
Sensor Mounting Bracket ('L' type) Mild Steel Blackodized for Eddy Current Probes, 2 Nos for UGB, 2 Nos for LGB, 2 Nos for TGB. Total 6 per Hydel Alternator. Tapped Hole: M10 Dimensions: Base Length: 100 mm; Base Width: 50 mm; Arm Height: 160 mm
8mm PRO Proximity Probe, Case Thread: M10x1 no armor; No Thread Length: 0 mm; Case Length: 60 mm; Total Length: 1.0 meter; Connector: mini coax; Regulatory Approval: CE Certified. 2 Nos for UGB, 2 Nos for LGB, 2 Nos for TGB. 6 per Hydel Alternator.
PRO Proximity Probe Extension Cable; System Length: 9.0m; Total Length of Extension Cable: 8.0m; Armor: No, 2 Nos for UGB, 2 Nos for LGB, 2 Nos for TGB. Total 6 per Hydel Alternator.
PRO Proximity Probe Driver for Eddy Current Probe, 8mm, dynamic vibration output, Driver Assembly, Calibrated to 4140 Steel; System Length: 9.0m; Mounting Type: DIN; Regulatory Approval: CE Certified 2 Nos for UGB, 2 Nos for LGB, 2 Nos for TGB. 6 per Hydel Alternator.
Sensor Mounting Pad MS Blackodized for Accelerometer (40x40x16mm) with M6 thread tapped. 2 per Hydel Alternator.
Stud, HS-AS024, Mounting/Grub Screws, 1/4"-28UNF Male, M6 Male 2 per Hydel Alternator.
Industrial Vibration Sensor, 4mV/mm /s, 2 Pin MS, 1/4"-28UNF Female 2 per Hydel Alternator.
Cable Assembly, Teflon 3.5mm dia, SS Conduit 5mm ID, 10m, 2 Pin MS, Shielded SKU : M60101 2 per Hydel Alternator. Temperature withstand capability less than 260 deg C Connection: 2 Pin MS at sensor end and Spade Lugs at other end
Junction Box - Al Di-cast Powder Coated, IP65, 230x200x110 mm 1No for UGB, 1 No for LGB, 1 No for TGB, 1 No fro TGB velocity sensor. 4 per Hydel Alternator.
Cable Bulk, 12 twisted pair, 0.5 Sq. mm, tinned copper, individual shielded and overall shield, PVC, FRLS, Armoured 75 meter per run. 4 runs of cables
Cabinet/Panel, Dimension: 2200 (H) x 600 (W) x 800 (D) in mm, IP32, accommodates max of 3 x 19" Rack Combined Quantity for 1 Hydel Alternators
19" Rack, 7 Position, 5U for holding various vibration modules. Combined Quantity for 1 Hydel Alternators
Relative Shaft Vibration Module, 2Ch Eddy current Probe Input and 1Ch Key Phasor Input, API Standard 670 Compliant 3 per Hydel Alternator. Accepts Input from Eddy Current Probe Drivers. Provides Power to Eddy Current Probe Drivers. Boasts the following features: 1. Programmable via front panel 2. Push buttons for programming 3. Alphanumeric and Bargraph Display 4. Full Scale, Measuring Units, Sensor Sensitivity, Alarm and Trip Set Points and several other things can be programmed 5. 4-20 mA output, Alarm and Trip relays per Channel, redundant MODBUS RTU and TCP/IP output, Start-Up Protection, Buffered Output.
Casing Vibration Module, 2Ch Vibration Input and 1Ch Key Phasor Input, API Standard 670 Compliant 1 per Hydel Alternator. It shall be able to measure vibration amplitude in terms of Displacement, Velocity and shall be able to display readings in pk, pk-pk or RMS. 1. Programmable via front panel 2. Push buttons for programming 3. Alphanumeric and Bargraph Display 4. Full Scale, Measuring Units, Sensor Sensitivity, Alarm and Trip Set Points and several other things can be programmed 5. 4-20 mA output, Alarm and Trip relays per Channel, redundant MODBUS RTU and TCP/IP output, Start-Up Protection, Buffered Output.
Dual channel Redundant Power Supply Unit, Input - 230 V AC 50/60 Hz, Output - 2 X 300 V DC Combined Quantity for 1 Hydel Alternators Dual channel Redundant power supply, Conforms to API 670
Blank Panel for unsused Rack Slot. Indicates Space for Future Expansion
Supervision of Erection and Commissioning of System 1 Manday per Hydel Alternator
IRD Mechanalysis Limited
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .