| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹16.2 L+₹23,184 (1.45%)Rejected-Finance | L2 | Rejected-Finance Second lowest | |
| 3 | L3₹17.0 L+₹99,366.50 (6.22%)Rejected-Finance | L3 | Rejected-Finance Third lowest | |
| 4 | L4₹17.1 L+₹1.2 L (7.23%)Rejected-Finance | L4 | Rejected-Finance Fourth lowest | |
| 5 | L5₹17.3 L+₹1.3 L (8.25%)Rejected-Finance | L5 | Rejected-Finance Fifth lowest |
Tender Value
Refer Docs
EMD Value
₹38,100
Closing Date
4 Nov 2020, 6:00 pmClosed
GE Palampur
Holta Camp Palampur Kangra (H.P) 176061
SPECIAL REPAIR OF WALL CEILING AND ROOF OF BLDG NO C-3 OF KV AT ALHILAL MIL STN
2020_MES_385192_1
GEP- /2020-21
Open Tender
Civil Works
Item Rate
180 days
Alhilal
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹38,100
Yes
26 Dec 2020
10 Oct 2020
6 Nov 2020
10 Oct 2020
4 Nov 2020
19 Oct 2020
Amount
SCHEDULE 'A' PART-I:- Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering etc. complete all as specified and directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, facia and fixed with self tapping screws complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.5 Cum , getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layer n.exc 25 cm, watering, and removing surplus soil to a distance n.exc 50 mtr and making good surfaces in soft/loose soil complete all as specified and directed.
M&L for PCC C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified.
S&F mild steel roof trusses (framed), trussed, purlins, crane gantries. rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-410-W (Grade E-250) complete all as specified and directed.
S&F steel work in tubular trusses including special shapedwasher etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St.-240 complete all as specified and directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes,without any attachment complete all as specified and directed.
M&L for preparing of new surfaces of steel of any description, over 10 cm width or girth not other wise described and appliying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed.
Dismantling of wall & celling boards (fiber pulp insulation etc) or insulation boards/slabs/blankets of any thickness, including cover fillets.
S&F anodised aluminium snap grid frame work for false ceiling including hangers 6mm dia GI adjusting level fixed to roof slab by means of ceiling cleats made out of G.I. Flat 40 X 3 mm size 60mm long and expansion hold fasterns 12.5mm dia 40mm long complete all as specified and directed.
M&L for 8 mm thick exposed metal frame ceiling with Calcium silicate board of liceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid Both side laminate complete all as specified and directed. Note:- Frame work for ceiling shall be measured and paid separately
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
M&L for RCC Nominal mix type B-1 1:2:4 (using 40mm graded crushed stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs etc complete all as specified and directed.
M&L TMT steel bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia as in reinforcement complete all as specified and directed.
M&L TMT bar 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for column, hooking end and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
Formwork to sides and soffit of floor or roof beams beam haunching ,girders,lintels,cantilever,shelves incl supports ,overhangs etc complete all as specified and as directed.
Demolition of brick work or stone /boulder masonry, built in CM, incl all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:6 complete all as specified and directed.
M&L for walling of random rubble stone masonry uncoursed, with best quality locally available harder stones such as granite, trap, basalt stone etc, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L 15 mm thick rendering on stone masonry surfaces or surface other than fair faces of brick work in CM 1:4 mixed with water proofing compound as per manufacturer's instructions finished even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound of approved quality, complete all as specified and directed.
M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 to be finished even and smooth with out using extra cement, complete all as specified and directed.
M&L three coats of white wash on newly plastered walls surfaces including preparation of surfaces
M&L for preparation of New plastered or un plastered surfeces of walls soffits, facia roof and applying, Two coats of exterior emulsion(Apex ultima protect of make "Asian" or equivalent in makes mentioned in Appendic 'C') over a coat of primer of same brand/ make as of exterior emulsion complete all as specified and directed.
M&L 15 mm thick rendering on stone masonry surfaces or surface other than fair faces of brick work in CM 1:6 mixed with WPC as per manufacturer's instructions, finished even and smooth with out using extra cement, complete all as specified and directed.
M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6, finished even and smooth with out using extra cement, complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of Oil bond distemper, white or tinted,over a coat of wall care putty 2 to 3 mm complete all as specified and directed.
Taking down chowkats or frames incl shutters (without taking off shutters from the frames) n.exc. 1.50 sqm each, and removing from site, complete all as specified and directed.
Taking down chowkats or frames incl shutters (w/o taking off shutters from the frames) exc. 1.50 sqm but n.exc. 4 sqm each and removing from site, complete all as specified and directed.
S&F Powder coated Anodised aluminium door shutters (minmium thickness of powder coating 50 micron), aluminium section of bottom rail 114.50x44.45mm, middle and top rail 85x44.45mm, style 85x44.45 mm and thickness of section not less than 1.80mm , weight of glazing clip not less than 0.124 Kg/m including necessary joining cleats, glazing clips, rubber neoprane packing two number of alumium handle 150mm long for each shutter, one aluminium door stopper, hinges type B-21,100mm long,anodised aluminium snap beading,screws, anodised aluminium fittings complete all as specified and directed.
S&F Powder coated Anodised aluminium window and ventilator shutters (minmium thickness of powder coating 50 micron), weight of aluminium section not less than 0.914 kg/m for style and rail, weight of glazing clip not less than 0.124 Kg/m including necessary joining cleats, glazing clips, rubber neoprane packing,anodised aluminium snap beading,screws,anodised aluminium fittings such as peg stays one number,hinges type B-21, 100 mm long two numbers,suitable handle one number on each shutter complete all as specified and directed.
S&F anodised aluminium frame for doors, windows, ventilators with minimum thickness of powder coating 50 micron with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F Pre-laminated Particle board exterior grade 9 mm thick with decorative choice both side lamination fixed with aluminium frame work complete all as specified
S&F galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
S&F mild steel framed work such as grills gratings etc with ends of bars shouldered and / or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walkways railings framework of water tanks and similar work conforming to Fe 290 Grade E-165.
Dismantling floor, hearth or wall tiling including cement mortar bedding and backing coat, and removing unserviceable materials,debris and rubbish to distance not exceeding 100m complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring and pavings not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed.
M&L for mat finish/ glossy premium quality Joint free (edge cut) coloured/printed ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile 600 x 600 /1200 mm as in floors etc. set and jointed in neat cement slurry and including 15 mm thick bedding layer in cement mortar 1:6 including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed.
M&L for mat finish/ glossy premium quality Joint free (edge cut) coloured/printed ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile 600 x 600 /1200 mm as in skirting/dado over and including 10mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/dado, window cills , door cills laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete, including 15 mm thick screed bed or bedding layer layer in cement mortor 1:6 necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed.
M&L for rounding to edges of Granite/ Kota stone slabs one edge, such as in steps cooking plateform, and other similar situation.
M&L for cement concrete type B-0, 1:2:4 (12.5 mm graded crushed stone aggregate) 25mm thick as in leveling course of flooring & roof complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in mass concrete complete all as specified and directed.
M&L Plain cement concrete, M-10 (Nominal Mix) type C-1 1:3:6 (using 20 mm graded crushed stone aggregates) as in surface channels or drains etc, complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed.(inner girth only measured)
M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straight or curved) complete all as specified & directed.
M&L 75 mm thick PCC type C-2 1:3:6 ( 40mm graded crushed stone aggregate) as in sub base of paver block/chequred tiles complete all as specified and directed.
M&L out door heavy duty full body vitrified tiles of any shade (as approved by GE) 600x600x15mm fixed with spacers over 6mm thick high polymer modified grey cement based tiles adhesive and grouted epoxy grout over and including 15mm screed in cement mortar 1:4, complete all as specified and directed.
M&L 60 mm thick rubber moulded coloured machine pressed precast concrete interlocking paver block any shape and size (shape as approved bt GE) laid in path,porch,hard standing or flooring etc conforming to IS-15658-2006, M-35 grade over and including 25 mm thick layer of sand cushioning, complete all as specified and directed .
M&L 75 mm thick PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate laid in alternative bays area not exc 2 sqm each as in plinth protection laid to slope of 1 in 12 including finishing the surface even & fair & filling the joints (6 mm wide) with mastic filling i.e one part of bitumen 85/25 or VG-30 and 3 parts of sand by weight complete all as specified & directed.
Taking down old drapery rod of any type with end brackets complete all as specified and directed.
S&F 25 mm drapery rod stainless steel and with fixing brackets complete all as specified and directed.
S&F end bracket of drapery rod both side complete all as specified and directed.
SCHEDULE 'A' PART-II:- Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Point wiring for one light point controlled by one way switch with cable of size 1.5 sqmm copper conductor cable multi strand PVC insulated FR-LSH (unsheathed) concealed type, drawing in and including PVC conduit 25mm dia having wall thickness not less than 2mm with sunk cast iron/pressed steel terminal boxes made out of 1.2mm thick sheet including one coat of red oxide primer on internal and external surface including cover plate for required module for mounting switches, sockets, regulators etc controlled by one, one way switch, including 1.5 sqmm PVC insulated FR-LSH copper conductor continuous earth wire complete all as specified and directed. Note - (i) Wiring shall be done using colour code.
All as per the description of serial item No 60 above but for one fan point/Exhaust fan controlled by one, one way switch and regulator complete all as specified and directed.
All as per the description of serial item No 60 above but for 5 pin switch socket outlet 5 Amp on same board with other switches, complete all as specified and directed.
All as per the description of serial item No 60 above but for 3 pin socket outlet 5 amp independent board complete all as specified and directed.
All as per the description of serial item No 60 above but for one bell point controlled by one, one bell push complete all as specified and directed.
All as per the description of serial item No 60 above but with 2.5 Sqmm PVC (FR-LSH) insulated copper conductor cable and 1.5 Sqmm PVC (FRLS) insulated copper conductor as earth wire for one 3 Pin 15 Amp socket out let on the independent board complete all as specified and directed.
S&F switch piano flush button, 5 Amps, 240 volts, single pole one way complete all as specified and directed.
Supply and fix socket out let 2 in 1, 3 Pin 5 Amps flush type all as specified and directed.
Supply and fix switch socket combination out let 2 in 1, 5/6 Pin, 5 and 15 Amps flush type all as specified and directed.
S&F bell push piano flush type single pole one way 5 amp 240 volts far electric bell complete all as specfied and directed .
S&F musical door bell AC 230 Volts single phase complete all as specfied and directed .
S&F Lamp holder, insulated body, with back plate for batten fitting with LED Lamp 3 W, complete all as specified.
S&F LED batten T-8, 1x18 W including LED tube Rod 18 W complete with provn of flexible cable 3 core, 23/.0076 from ceiling rose to connector complete all as specified and directed.
Taking down old burnt out bulk head fitting any type and installaton LED Bulk Head 10W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP54 complete all as specified and directed.
S&F ceiling rose surface type bakelite 50x65 mm two to three terminalscomplete all as specified and directed.
S&F recess mounting LED 2X2 fittings 36 W including provn of flexible cable 3 core, 23/.0076 from ceiling rose to connector complete all as specified and directed.
Material and labour for sub main wiring with two single core PVC insulated, FR-LSH unsheathed multi stranded copper conductor cable confirming to IS 694-1990 of size 6 Sqmm (nominal area) and draw in & including Steel conduit all fittings such as Tee, connector pieces, L-junction etc on joints, not less than 2 mm thick and continuous PVC insulated FR-LSH, single core copper conductor multi stranded unsheathed 6 Sqmm as earth wire and making good the disturbed surfaces, complete all as specified and as directed. Note:- Two single core cable and one number earth wire shall be measured together as one length.
Taking down ceiling/exhaust fan any type/size and refixing at same or other location after cleaning, greasing, oiling & servicing complete all as specified and directed.
Supply and fix distribution board iron clad, vertical DB double door with IP-43 protection suitable for MCB TPN as incommer and MCB as outgoing 415 Volts 3 phase 50 Hz 4 way, complete with appropriate size copper busbar and neutral link complete with one MCB TPN 415 Volts 63 Amps rating, 16 KA breaking capcity of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site and including taking down old unserviceable existing DB any type/size complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated DB for fixing of MCBs, SPN 8 ways double door, IP-42 protection with 200 Amp rated bus bar, 240 Volts including taking out of old MCB DB of any type/size and removing from site to MES store for reuse if serviceable or for credit complete all as specified and directed.
Supply and fix isolator TPN 63 Amp 415 volts, 10kA, 50 Hz of complete all as specified and directed.
Supply and fix MCB SPN 240 volts, 10kA, 50 Hz of capacity 40-63 Amps 'C' series complete all as specified and directed.
S&F MCB SP, 240 V, 6-40 Amp 10 KA complete all as specified and directed.
Taking down old unserviceable exhaust fans any type/size, supply & fixing exhaust fan (steel body) AC single phase 230V of size 300 mm, 1400 RPM with louvers shutter including making/repairing hole in brick/stone wall as per site reqmt and making good disturbed surfaces, complete all as specified and directed. Note:- Old unserviceable exhaust fan to be deposited in MES store yard.
supply and fixing celling fan 1200 mm sweep power 53 W RPM 380 Air delivery 220CMM with downrod, complete all as specified and directed.
Supply & fixing temper proof electronic meter (with Backlit LCD Display) accuracy class 1.0 (ISI Marked), three phase, 3 wire, 240 volts (+) 20%, (-) 40% of capacity 10 to 60 Amps (Measures & Displays kWh, V, I, KW, six months history of Energy & MD in kW), 50 Hzs, anti temper proof features as specified including necessary sealings and connection with suitable size of PVC insulated copper cable multistrand with appropriate size of copper lugs at no extra cost including carefully, complete all as specified and directed. Note:- Old unserviceable energy meters to be deposited in MES store yard.
Earthing with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to 4mm dia galvanized iron wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 15mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including char coal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthing test point all as specified or indicated, including testing on completion, complete all as specified and directed. NOTE: The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
Supply, laying and testing cable XLPE insulated screend PVC bedded, galvanised steel strip or wire armoured electric power cables (Heavy duty) 1100 V grade with stranded aluminium conductor of size 16 sqmm x 4 Core, laid in trenches or passing through pipe including taking down of existing cable/service connection of any type or size and removing from site to MES store for reuse if serviceable or for credit complete all as specified and directed.
Excavation in trenches in any type of soil not exc. 1.5m wide and not exc. 1.5m deep for laying cables, foundation of poles, stays etc and getting out, complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layers n.exc 25cm thick, complete all as specified and directed.
Removal of excavated material to be distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified and directed.
M&L for sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
M&L for sub class 'B' brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to length of the brick complete all as specified and directed.
S&F 40mm dia bore GI tubing (light grade) with all fitting laid in trenches or along pole/bldg or under road crossing and protection pipe or fixed alongwith wall/pole with necessary clamp nut bolt and washer, complete all as specified and directed.
M/S Bharmouri Construction
M/S THAKUR ENTERPRISES
VIVEKA ENTERPRISES
S K MAHAJAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .