Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC AT PO MAIN ROAD SAYAL DISTT RAMGARH JHARKHAND | MAIN ROAD SAYAL | RAMGARH | JHARKHAND | L1 | Accepted-AOC as per wo | |
| 2 | Rejected-Technical AT RIVER SIDE BHURKUNDA DIST RAMGARH | BHURKUNDA | RAMGARH | - | Rejected-Technical complied | |
| 3 | Rejected-Technical AT SAYAL SAYAL DISTT RAMGARH JH | NA | NA | 825101 | - | Rejected-Technical complied |
Tender Value
₹9.5 L
EMD Value
₹11,900
Closing Date
21 Feb 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PE(EnM) Officer Birsa Project
PE(EnM) Office Birsa Project
Erection and dismantling of 3.3 KV OH Line at Birsa Project
2025_CCL_328681_1
PE(EnM)/Birsa/eTender/24-25/11
Open Tender
Electrical and Maintenance Works
Item Wise
21 days
Birsa Project
please refer Tender document
2 documents required · 2 mandatory
₹11,900
21 Apr 2025
11 Feb 2025
22 Feb 2025
12 Feb 2025
21 Feb 2025
12 Feb 2025
12 Feb 2025 - 15 Feb 2025
Amount
Erection of metallic pole of above 10.0 metre and up to12.0 metre length in cement concrete 1:3:6 (1cement:3coarse sand : 6graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc.as required.
Erection of AAA (Dog conductor) of 7/3.35 mm to7/4.00 diameter and above including binding etc. as required 22 Span x3 wire x 50Mtr.=3300 Mtr.3.3KMx344Kg/km=1135.20 Kg
Erection of G.I. Wire No.8S WG including binding etc as required. 22 spanx50Mtr. =1100Mtr.(1.1 K.M. x131Kg/Km=144.10Kg)
Supplying and erection of galvanized stay setfor11 KV overhead lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turnbuckle (20mmX600mm),7/4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size ) foundation including excavation and refilling etc. as required
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over headline conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required
Supplying of channel iron 75mm X40mm X6mm (7.14kgper metre)V shape cross arm for two11KV overhead line conductors complete with 50mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc(as per drawing)and painting with primer and finish paint as required.
Erection of pole top/straight two wire/V shape two wire, angleiron/channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6mm (7.14 kg per metre) double pole cross arm for three wire11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing)and painting with primer and finish paint as required
Supplying and erection of a set of cross bracing FRL Same work for 11KV over headline double pole structure having four members fabricated out of 50mm X50mmX 6 mm angle ironto form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing)and painting with primer and finish paint as required
Erection of double pole 3 wire cross arm for 11KV/22KV/33 KV over headlines as required.
Supplying & Erection of 11KV pin insulator complete with Large steel head G.I.pin, nuts, washers etc as required
Supplying and erection of 11 KV disc insulator for 11 KV overhead lines with galvanised insulator fittings, ball and socket type and complete with galvanized strain clamps, bolts, nuts, Washers etc. as required.
Dismantling of over head line scomprising of copper/aluminium overhead conductor, G.l. wire, cross arms, insulators etc. as required.
Supplying & Erection of 11KV pin insulator complete with Large steel head G.I.pin, nuts, washers etc as required
Supplying and erection of 11 KV disc insulator for 11 KV overhead lines with galvanised insulator fittings, ball and socket type and complete with galvanized strain clamps, bolts, nuts, Washers etc. as required.
Dismantling of over head line scomprising of copper/aluminium overhead conductor, G.l. wire, cross arms, insulators etc. as required.
Supplying of G.I. Wire No.8S WG forcontinuous earthing. 144 Kg for Earth wire & 97 Kg for cradle guard
Loading, Transporting and Unloading of copper/aluminium overhead conductor,G.l. wire, cross arms, insulators etc. as required.
Loading, Transporting and Unloading of Poles 41 Nos (28 Nos Erection & 13 Nos Dismantling) from Work shop to working site
Total impact of GST for the purpose of CTC
technical_340686.pdf
PDF • 0.21 MB
techsummary_340686.pdf
PDF • 0.64 MB
finance_340686.pdf
PDF • 0.20 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_340686.pdf
PDF • 1.55 MB
2.pdf
PDF • 0.70 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .