Loading…
Loading…
Tender Value
₹1.1 Cr
EMD Value
₹1.1 L
Closing Date
14 Jul 2026, 6:00 pm
Similar tender results from the same govt authority in the past 3 years.
EXECUTIVE ENGINEER’S OFFICE, SURAT (R&B) DIVISION NO.1, SURAT
Repairing of Samras Boy’s Hostel at Surat, Dist: Surat. (Repairing outside polymer plaster, bathroom plumbing, toilet repairing, door-window, motor and other misc.work)
316389
3-4 of 2026-27
Open
Civil Works
Surat
7 documents required · 7 mandatory
₹3,600
Executive Engineer, Surat (R&B) Division 1, Surat
₹1.1 L
22 Jun 2026
22 Jun 2026
22 Jun 2026
14 Jul 2026
22 Jun 2026
Name of work :-
Repairing of Samras Boy's Hostel at Surat, Dist: Surat. (Repairing outside polymer plaster, bathroom
plumbing, toilet repairing, door-window, motor and other misc.work)
Bill of Quantities
(A) Percentage Rate Tender (Up to INR 50 Cr. )
m Item of work Quantity Unit Amount
1 Dismentaling tiled of stone floors laid in mortar including stacking of 1197.00 Sqmt 50.11
serviceable materilas and disposal of unserviceable materials with all
2 Demolition and disposal of unserviceable materials with all lead and 5.00 Cumt 639.72
lift.(i) Cement concrete.
3 Dismantling santtary fittings like wash basin, W.C.Pan Indian and 80.00 Nos. 425.93
European type, flushing tank etc. including stacking the materials with
all lead and lift.
4 Dismentling C.I. pipes G.S.W.pipes abd A.C. rain water pipes with 5310.00 Rmt. 78.51
fittings and clamps including stacking the materials with all lead and
lift ( for any dia, of pipe)
5 Dismentling doors, windows, ventilators etc. (wood or steel) shutters 82.00 Nos. 197.09
including chowkhats architraves, holdfasts and other attachment etc.
complete and stacking them within all lead and lift.(i) Not exceeding
6 Removing the scrapping of old detoriated plaster of any thickness 692.30 Sqmt 20.55
from wall/Rcc member including stacking of servicable material and
disposal of unservicable material from site of work with all lead and
7 Providing and laying water proofing treatment by conventional 44.00 Sqmt 950.41
method including cleaning the slab surface by wire brush as directed
including provding first layer of C.M. 1:4 of 40 mm thickness mixed
with water proofing compound at rate prescribed by manufacturer,
including putting of brick bats of average thickness 40 mm Well
immerssed in water laid uniformly on first layer of mortar including
applying cement slurry @ rate of 0.08 bag/sqm. on fixed layer of brick
bats including maintaining necessary slope, in second layer 40 mm
thick C.M 1:4 mixed with water proofing compound as directed,
including finishing smooth with cement slurry as directed complete.
8 Providing And filling with good quality sinder(steam coal) as directed 14.00 Cumt 454.50
by engineer in charge in sunks in layers of 15 cm thick,including
watering,placing ,ramming well etc as directed, for all floor.
9 Providing 20 mm thick Water proof cement plaster for sunk in single 256.00 Sqmt 482.78
coat on brick / conctrete wall for interor plastering up to floor two
level finished even and smooth (ii) cement mortar 1:3 (1- cement,
sand) and mixing waterproofing materials of approved brand and
manufacture in cement mortar in proportion recommended by the
manufacture for All floor.
10 P & L 30x30 cm. Matt Finished Ceramic Tiles 6 mm thick in flooring 110.00 Sqmt 960.42
treads of steps and landing laid on a bed of 12 mm thick cement
mortar 1:3(1-cement:3-coarse sand)finishing with flush pointing in
colour cement slurry etc. complete. Colour and Shade approved by
Engineer-In-Charge
11 Providing and laying coloured glazed tiles of the size 300 mm x 200 565.00 Sqmt 1513.28
mm x 8 mm / 300 mm x 450 mm x 8 mm in skirting, risers of steps and
dedo on 10 mm. thick cement plaster 1:3 (1 cement : 3 coarse sand) &
jointed with white cement slurry.
12 Providing erecting and fixing double coated Syntex PVC. (ISI) water 5000.00 Lit 3.95
tank of required capacity each with all necessary fittings and
connection etc. complete on terrace.
13 Providing laying and jointing in true line and level 15mm dia. U.P.V.C. 1670.00 Rmt. 72.65
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concealed as directed
including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost
of all materials.
14 Providing laying and jointing in true line and level 25mm dia. U.P.V.C. 1670.00 Rmt. 91.84
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concealed as directed
including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost
of all materials.
15 Providing laying and jointing in true line and level 40mm dia. U.P.V.C. 430.00 Rmt. 148.12
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concealed as directed
including necessary fittings etc. including testing of pipe
and joints and fixing the same with adhesive solvent, including cost of
16 Providing laying and jointing in true line and level 50mm dia. U.P.V.C. 630.00 Rmt. 195.67
Pipe ( SCH- 40) for cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost of all
17 Providing and fixing concealed center point to wall ceiling & floor 720.00 Rmt. 170.36
CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF)
seal for potable water of following dia. nominal bore tube fittings and
clamps including making good the wall, ceiling and floor etc.
complete.[A] 15 mm.
18 Providing and fixing concealed center point to wall ceiling & floor 720.00 Rmt. 253.82
CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF)
seal for potable water of following dia. nominal bore tube fittings and
clamps including making good the wall, ceiling and floor etc.
complete. [C] 25 mm.
19 Providing and fixing concealed center point to wall ceiling & floor 400.00 Rmt. 447.72
CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF)
seal for potable water of following dia. nominal bore tube fittings and
clamps including making good the wall, ceiling and floor etc.
complete. [C] 40 mm.
20 Providing and fixing ball cock of approved. quality as directed.(A) 8.00 Nos 189.84
Copper Metal (ii) 50mm dia.
21 Providing, laying and jointing in true line and level 160 diametre 200.00 Rmt. 834.38
U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and
other end socketed with rubber ring, & fittings conforming to ISI
14735-1999 of approved make for drainage system pipe line, pipe
shall be jointed with each other with rubber lubricant, pipe shall be
fixed on wall using of PVC clamp of the size 160 mm diametre x
mm length x 196 mm heigh at every 2000 mm center to center or shall
be concealed in walls as directed including necessary fittings such as
bends, shoes etc. including testing of pipes and joints and jointed with
adhesive solvent cement including cost of all materials.
22 Providing laying (to level or slopes) and jointing reinforced concrete 150.00 Rmt. 678.02
Light duty non-pressure pipes I.S. class NP2 of the following internal
diameter with collars and butt ends prepared for collar joints
including testing of joints complete.(D) 300mm
23 Providing, laying and jointing in true line and level 75 mm dia. UPVC 480.00 Rmt. 740.33
SWRType B pipe conforming to IS 13592-1992 with one end plain and
other end socketed with rubbering and fitting conforming to ISI 14735-
1999 of approved make for drainage system pipe line, pipe shall be
jointed with each other with rubber lubricant, pipe shall be fixed on
wall using of PVC clamp at every 2000 mm c/c or shall be conceled in
walss as directed including necessary fittings such as bends, shoes etc.
including testing of pipes and joints and jointed with adhesive solvent
cement including cost of all materials.
24 Providing, laying and jointing in true line and level 110 diametre 480.00 Rmt. 878.57
U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and
other end socketed with rubber ring, & fittings conforming to ISI
14735-1999 of approved make for drainage system pipe line, pipe
shall be jointed with each other with rubber lubricant, pipe shall be
fixed on wall using of PVC clamp of the size 110 mm diametre x
mm length x 145 mm heigh at every 2000 mm center to center or shall
be concealed in walls as directed including necessary fittings such as
bends, shoes etc. including testing of pipes and joints and jointed with
adhesive solvent cement including cost of all materials.
25 Providing and fixing in PVC SWR cowel went 75mm dia to pipes.(B) 8.00 Nos 15.66
26 Providing and fixing in PVC SWR cowel went 110mm dia to pipes.(B) 8.00 Nos 28.79
27 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm 308.00 Nos 599.64
diameter with jali of the following nominal diameter of self cleansing
design with C.I scread down or hinged grating including the cost of
cutting and making good the walls.
28 Providing and fixing screw down bib taps of following size.(B) Brass 706.00 Nos. 186.83
chromium plated screws down Bib Tap. (i) 15mm dia.
29 Providing and fixing brass screw down stop tap.(A) 15mm dia. 456.00 Nos 205.83
30 Providing and fixing pillar tap, capstan head, screw down high 406.00 Nos 308.73
pressure with screws, shanks and back nuts. (i) 15mm dia.
31 Providing and fixing wsh down water closet (European type, W.C. Pan) 40.00 Nos 1356.81
with integral P or S trap including jointing the trap with soil pipe in
Cement Mortar 1:1 (1-Cement : 1-fine sand) (Seal and cover to be
measured and paid for separately (A) vitreous China Pattern :(i) in
32 Providing and fixing 12.5 Litres low level flushing cistern with a pair, of 262.00 Nos 2370.39
C.I. or Mild brackets, complete with fittings such as lead valve less
syphon, 15mm nom.nal size brass ball valve with polythene float, C.P
brass handle unions and couplings for connections, with inlet, outlet
and overflow pipes, 40mm dia. porcelain enamelled flush bend
including cutting holes in walls and making good the same connecting
the flush bend with cistern and
closet (overflow pipe to be measured and paid for separately)(A)
Vitreous China (I) In white colour
33 Providing and fixing plastic seat and cover for wash down water closer 262.00 Nos 291.33
with C.P. brass hinges and rubber buffers. (B) Plastic seal and cover.
34 Provision and fixing water closet squatting orissa type W.C. pan size 1.00 Nos 1647.31
580mm integral footrest and 100 mm P or S trap and in cluding
mm dia CP brass flush valve and GI inlet connection etc. comp. (A)
Vitreous china long pattern white or colour
35 Providing and fixing chromium plated brass half trun flush cock of 262.00 Nos 263.77
approved quality including fixing in pipe line etc. complete.(ii) 25mm
36 Providing and fixing Jet spray heavy duty with S.S. Braided hose 60 cm 262.00 Nos 355.52
long with wall hook and other accessories etc. completed
37 Providing and fixing G.I. inlet connection for flush pipe with W.C. Pan 262.00 Nos 46.44
38 Providing and fixing wash basin with single hole for pillar tap with C.I. 40.00 Nos 1988.71
Or M.S. brackers painted white including cutting holes and making
good the same including pillar tap, Brass waste, stop cack , bottle
trap and M I fisher union fittings :(ii) Flat back wash basin 500mm x
400mm size including all necessary fittings etc complete shade and
pattern as approved by Engineer in charge.
39 Providing and fixing West Pipe for Wash basin including all necessary 406.00 Nos 50.50
fittings etc complete
40 Providing and fixing S.W. gully trap with C.I. grating brick masonry 2.00 Nos 1246.92
chamber and water tight C.I. cover with frame of 300mm x 300mm
size (inside) with standard weight (i) Square mouth traps (B) 150mm x
100mm size P or R type
41 Constructing brick masonry chamber for underground C.I. Inspection 5.00 Nos 3208.77
chamber and bends with briocks having croshing strength not less
than 35Kg. Cm2 in C.M. 1:5 precast RCC cover 455mm x 610mm
intenal dimensions with frame (R.C.C. top slabe with 1:2:4 mix (1-
cement :2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with cement
mortar 1:3 finished smooth with a floating coat of neat cement on
walls and bed concrete etc. complete (i) Inside dimensions 455mmx
610mm and 450mm deep for single pipe line.
42 Constructing brick masonry chamber for underground C.I. Inspection 5.00 Nos 3916.78
chamber and bends with briocks having croshing strength not less
than 35Kg. Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x
610mm intenal dimensions total weight of cover with frame to be not
less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C.
top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete 1:5:10 inside plaster
15mm thick with cement mortar 1:3 finished smooth with a floating
coat of neat cement on walls and bed concrete etc. complete.(i) Inside
dimensions 500mmx 700mm and 450mm deep for single pipe line.
43 Extra over items for every additional depth of 0.1M. of part thereof 5.00 Nos 242.39
beyond 450mm depth for Brick masonry chamber.(i) for 455mm x
44 Extra over items for every additional depth of 0.1M. of part thereof 5.00 Nos 264.86
beyond 450mm depth for Brick masonry chamber.(i) for 500mm x
45 Providing 15mm thick cement plaster in single coat on Rough (Similar) 497.00 Sqmt 287.85
side of single or half birck walls / concrete wall for interior plastering
and finished even and smooth in C M 1:4 (1 cement : 4 coarse sand)
finish etc. comp. For All floor
46 Providing average 20 mm thick single coat polymer plaster by 2657.00 Sqmt 541.36
removing detoriated plaster over RCC member, like column, beam,
slab etc. exposing existing reinforcement including scraping by wire
brush, applying rust removing chemical, rust convertor and zinc rich
primer on existing reinforcement, applying polymer bonding agent on
existing concrete surface including plastering in CM 1: 3 in single coat
including standard quality (Dr, fixit or any equivalent brand) curing
compound agent and finishing with floating coat of neat cement slurry
adding Polyalk Fix Prime polymer chemical as per directed by Engineer
- in - charge for all floors.
47 Providing and fixing 90 cm high Stainless steel railing made from 54.00 Sqmt 4053.13
anticorrocive 304 grade S S pipe of 50 mm dia (16Gauge) as hand rail
with S S 304 grade Baluster of 38 mm dia (16Gauge) as a vertical
support fixed in RCC slab at 0.50m c/c including three horizontal S S
pipes of 16 mm dia (16Gauge) at eqal distance fixed including The
Provisions in Nation Building Code 2016, part,Annex:B-6.2 with
baluster ,accesies as per detailed drawing as directed etc. complete.
48 Painting Two coats (excluding priming coat) on previously painted 54.00 Sqmt 90.37
steel and other metal surface with enamel paint, brushing to give an
even shade including cleaning the surface of all dirt, dust and other
foreign matter.
49 Wall painting (two coats) with plastic emulsion paint of approved 8663.00 Sqmt 83.36
brand and manufacture on undecorated wall surface to give an even
shade including throughly brushing the surface free from mortar
droppings and other foreign matter and sand papered smooth.
50 Wall painting (two coats) with plastic emulsion paint of approved 2729.00 Sqmt 89.04
brand and manufacture on undecorated ceiling surface to give an
even shade including throughly brushing the surface free from mortar
droppings and other foreign matter and sand papered smooth.
51 Removing, Repairing and Refixing Old existing wooden door shutter 100.00 No 1808.91
including repairing the shutter/frame using Randha machine and
replacing old fixture and fastening with new SS 304 grade fixtures
like 3 Hinges, 1 Stoppers, 1 Aldrop , 2 Handle & 1 lock etc. and as
directed by engineer in charge etc comp.
52 Removing and Refixing Old existing FRP Door Aldrop, Stoppers, Hinges 280.00 No 635.29
& Handle etc. including Labour Charge and fixture and fastening as
directed by engineer in charge etc comp.
53 Removing, Repairing and Refixing Old existing Main wooden door 5.00 No 7830.53
shutter including fixing New Pivot and Floor Spring repairing the
shutter/frame using Randha machine and replacing old fixture and
fastening with new SS 304 grade fixtures like 6 Hinges, 2 Stoppers,
Aldrop , 2 Nos. 30cm Handle & 1 lock etc. and as directed by engineer
in charge etc comp.
54 Removing, Repairing and Refixing existing Alluminium window frame 100.00 No 808.00
with glass of all size shutter/frame, replacing all old Mosquite Net
fixtures with & New Mosquite Net with new locks, screws etc.
including repairing the shutter/frame with Rates includes all labour
charges for removing, repairing & refixing the window, all materials,
transport cost, taxes etc.and as directed by engineer in charge etc
55 Removing, Repairing and Refixing existing Alluminium fix ventilation 140.00 No 439.35
frame with glass of all size shutter/frame, replacing all old Mosquite
Net , fixtures & New Mosquite Net with new locks, screws etc.
including repairing the shutter/frame with Rates includes all labour
charges for removing, repairing & refixing the Ventilation, all
materials, transport cost, taxes etc.and as directed by engineer in
charge etc complete.
56 Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in 453.60 Sqmt 1092.37
flooring treads of steps and landing laid on a bed of 12mm thick
cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush
pointing in white cement.
57 Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in 68.10 Sqmt 1135.80
skrting risers of steps and dedo on 10mm thick cement plaster 1:3 (1-
cement : 3-coarse sand) and jointed with white cement slurry
58 Providing and fixing 35 mm thick flush door Single shutter, solid core 112.00 Sqmt 3157.26
with Shutter of Factory made & Stamped I.S 12823 Grade one ,Type
one ,melamine faced three layred resin Flushed Door Having
Decorative Lamination on both sides & 12 mm T.W.Beading Around
the Door,FROM HOLDING LICENCE FOR MINIMUM 5 YEARS .and
stainless steel handle and necessary Locking system of Godrej, zinc
coated hinges ,fixtures & fastenings etc directed by engineer in
59 Providing and fixing FRP frame size 100 x 50 mm and 35 mm thick FRP 53.00 Sqmt 2547.22
depress panel Single shutter having extra reinforcement on sides &
edges in Gel coat finish.The core of the shutter & frame is to be filed
up with injected fire retradat grade polyurethene foam done in situ
along with embeded wooden pieces for stiffening & also taking hinges
& fintures.The whole FRP frame & shutter is to be waterproof,
weatherproof ,termite proof & resistance to mild acid/alkali.Rates are
to be inclusive of S.S hinges with necessary screws & alluminum
fixtures & fastenings & fartener sleeve.Colour and Shade approved by
Engineer-In-Charge. D4
60 Providing and fixing polished 18 mm thick Granite stone in Single 171.00 Sqmt 2379.56
piece with full round edge and polished of approved quality in clading
on Cill & Jambs and around the doors/ windows/ ventilation with
mm thick cement motor CM (1:4) and fixing with cement slurry &
adhesive including moulding of exposed edges as directed by
engineering in charge etc. complete.
61 Constructing brick masonry Grease chamber for underground C.I. 1.00 Nos 4740.94
Inspection chamber and bends with briocks having croshing strength
not less than 35Kg. Cm2 in C.M. 1:5 Two C.I. cover with frame (Light
duty) 980mm x 660mm intenal dimensions total weight of cover with
frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame
15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-
graded stone aggregate 20mm size) foundation concrete 1:2:4 inside
plaster 15mm thick with cement mortar 1:4 finished smooth with a
floating coat of neat cement on walls and bed concrete etc.
complete.(i) Inside dimensions 910mmx 610mm and 450mm deep for
Three pipe line. as per directed by Engineer-in-charge.
62 Providing & erecting open well horizontal mono block pump set with 1.00 Nos 18498.15
cast iron body, complete for three phase submersible motor having
[C] For 3 HP 3 phase open well horizontal mono block pump set
suitable for 85 LPM to 270 LPM @ 11 mtr to 33 mtr head suitable for
50/65 mm dia delivery pipe Cat.II
63 Supplying submersible pump set suitable for bore of 100 mm. dia. or 3.00 Nos 21997.80
more having three phase motor capacity not more than 5 H.P. with
following capacity ..(B) (16 stage) 140 to 180 LPM discharge at 96 to
69 mtrs. head respectively suitable for 50mm dia. delivery pipe Cat.II
64 Providing & erecting open well horizontal mono block pump set with 2.00 Nos 56060.05
cast iron body, complete for three phase submersible motor having
[I] For 20 HP 3 phase open well horizontal mono block pump set
suitable for 1750 LPM to 1150 LPM @ 33 to 51 MTR head suitable for
65 /80 mm dia delivery pipe Cat.II
65 Supplying & erecting approved make motor control cubical panel 6.00 Nos 13182.52
[Star delta] made from 16G CRCA sheet duly epoxy powder painted
inside and outside with hinged doors and locking with suitable size of
ON - OFF isolator (AC 3 / 23 duty) main fuses. Digital volt and current
meter (in a single unit) with micro controller based control unit and
current sensing single phasing preventer electronic overload
protection, over voltage (Programmable) protection and under
voltage (Programmable) protection, prod less dry run protection
programming facility for setting of all parameter like overload current,
high voltage limit, low voltage limit, dry run limit with digital
indication on seven segment LED display for any fault like over load,
high voltage, low voltage, dry running single crimped, electronic star
delta timer, feather touch start / stop push buttons to be erected on
angle iron frame. Grouted on wall the contactors will be of L& T,
Siemens , BCH make only) (A) S/D up to 7.5 H.P.
66 Providing and laying cement concrete 1:2:4 (1- Cement : 2- Coarse 1.00 Cumt 3741.69
sand : 4- graded stone aggregates 20 mm nominal size) and curing
complete excluding cost of formwork in (A) Foundation and Plinth
67 Providing and fixing of Ridge flashing for roof panel shall be made out 12.00 Sqmt 867.39
of 0.5 mm thick pre coated GI sheet . The Precoated sheet shall be of
minimum 240 mpa steel grade confirming to IS 14246:1995 and shall
have zinc coating of minimum 120 gsm as per IS:277:1992 , 5-7
microns epoxy primer on both side of the sheet and polyester top
coat 15-18 micron. The PPGI Sheet shall have plastic protective guard
film of minimum 25 microns to avoid scratches during transportation.
The ridge shall be fixed to the steel members by pop rivet or self
drilling/self stitching fastners @ maximum 450 mm c/c along length of
capping/flashing etc complete .
68 Steel work, welded in built up sections framed work including cutting, 300.00 Kg 91.08
hoisting, fixing in position and applying a priming coat of read lead
paint & two coat oil paint. (A)In beams and joists, channels angles
Tees, flats, with connecting plates or angle cleats as in main and cross
beams. Hip and jack rafters, purlins conneted to common rafters and
69 Supply, installing, testing and commissioning of Normax make CI 1.00 No 6161.00
heavy duty ball type foot valve with flanges, nut bolts, gaskets etc.
with necessary complete accessories. 100 mm dia.
70 Supply, installing, testing and commissioning of Normax make CI 1.00 No 3535.00
heavy duty ball type foot valve with flanges, nut bolts, gaskets etc.
with necessary complete accessories. 50mm dia.
71 Drilling in soil with lowering of pipes concrete sealing including gravel 80.00 Rmt. 545.40
packing clay breaking and development of bore with air compressor
by required capacity vertical test etc. complete including the cost of
benimeter 250mm dia.
72 Supplying slotted PVC pipes of approved quality at site of work 30.00 Rmt. 555.50
confirming to IS. 1239/1974 180mm dia.
73 Supplying PVC plain pipes of approved quality at site of work 50.00 Rmt. 494.90
confirming to IS. 1239/1974 180mm dia.
74 Providing and erecting ISI marked PVC insulated PVC Sheathed Flat 130.00 Rmt. 121.20
flexible Submersible copper cable approved make of following Size.
(B) 3 Core x 2.5 Sq. mm.
75 Supplying submersible pump set suitable for bore of 150 mm. dia. or 1.00 No 32996.70
more having three phase motor capacity not more than 7.5 H.P. with
following capacity .. (B) ( 8 stage) 390 to 350 LPM discharge at 62 to
70 mtrs. head respectively suitable for 50mm dia. delivery pipe Cat.III
76 Lowering of submersible motor pump set at the depth of following 1.00 Per 3030.00
,complete with required. Nos. and size of casing pipes erected by job
means of proper chain pulley block & pipe wrenches after checking of
threads of each pipe with coupling to take the load of the pump set
and pipe assembly filled up with water (B)Above 60 mtrs. and Up to
77 Providing and fixing to wall ceiling and floor HDP pipes tubes (medium 80.00 Rmt. 90.90
grade) of the 50mm nominal bore, tube, fittings and clamps include.
Making good the wall ceiling and floor.(F) 50mm dia.
78 Providing and fixing gun metal cock of non return full way wheel 1.00 No 959.50
valve.(F) 50mm dia
Rupees One Crore Five Lakh(s) Fifty Thousand Two Hundred Twenty And Paise Twenty Six Only
I/We am /are willing to carry out the work at…………% above/below percent (should be written in figures and words) at the
estimated rates mentioned above amount of my/your tender works out as under.
*Estimated Amount *Estimated Amount
put to Tender Rs. 10550220.26 put to Tender Rs.
Deduction …………….. % below………………… Add ………… % above Rs. …………….
1 The Credit Value of Dismentalled Materials of Amount Rs.82226.00 (Rupees Eighty Two Thousand Two Hundred
Twenty Six Only) shall be recovered from the 1st Running Bill of the Contractor.
2 The Contractor shall be exhibit board as per government circular No.BDG/3277/1657 N dated 26/01/1997 S (M.GUJ)
with detailed specification and details of work and amount Involved at site without any payment as directed by
Engineer-In-Charge.
3 All work shall be carried out as per public work department hand book and other specifications of Division or as
4 All columns in the Schedule should be filled in ink & the total of the entries in the last column should be struck by
Contractor under his sign.
5 Rates quoted include clearance of site (Prior commencement of work and its close) in all respects and hold good for
work under all condition, site, moisture/ weather etc.
6 The Boards stating the detailed specification & detailes of Work shal be provided by the contractor as per
Government Resolution T.No.1890-240- Dtd.18/11/1990 and directed by contractor at his own cost immediately on
recommanding the work order.
7 Testing of Material Shall be done as per the statement attached with specification,The material IS Tested in GERI by
Executive Engineer Surat and Bill for the testing charges shall be paid by Executive Engineer,1% of the Amount put to
8 1% of the Construction Cost Shall be deducted from the bill Amount of the contract as per the Buildig and other
Construction works walfare cess at 1996(Labour and Employment Department Letter No CWA-2004-1831-M(3)Dated
9/12/2005 notification Of Labour & Employment department dt.03/01/2005 & Labou & Employment Department
Letter no GWA/2004-841M(B) Dt 14/12/2005 & Dt.30/1/2006.
9 In Case of RCC items Where there is a change in Grade of Mix or Change as per Actual Mix design the cost of
difference of Cement Difference shall be deducted from the rate of original item at the rate of star rate mentioned in
10 Contractor are advised to visit site before loading tender rate.
11 Necessary wiring point and drainage point are installed at Site however any modification in electrical installation and
drainage & water supply connection and minor correction to perform experienced in Lab shall be done by contractor
at his risk and cost.
12 The Rates are inclusive of all the taxes (Excluding GST),Transport Charges,Octroi duty and storage Charges up to date.
13 The materials Covered for wiring should be got approved from the Engineer Incharge of the work.
14 GST and Income tax TDS will be deducted at a source while making payments of bills.
15 GST will be paid extra as per Govt. amendment.
16 The Materials on the work shall have to be used and carried out as specified in technical note.
I/We hereby Declare that I/we have Visited the site and fully Exquisite myself/ourselves with the local situation
(A) regarding materials,Labour and other factors pertaininfg to work before submitting tender.
I/We hereby Declare that I/we have carefully Studied the condition of Contracts,Detailed Specification and other
(B) tender Document of this work and agree to execute the same accordingly.
Deputy Executive Engineer
Surat (R&B) Sub-Division No.
Signature of Bidder
Executive Engineer
Surat (R&B) Division No.1
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD-Smras Boys_compressed.pdf
3 BOQ.pdf
4 Specification Samras Boys Hostel Repairing (2 Side).pdf
7 GR 1-133 Pg Final 2 side-1-60.pdf
7 GR 1-133 Pg Final 2 side-61-133.pdf
8 Building-Specification Booklet (2 side).pdf
Performance Security GR.pdf
Download all tender documents and submit your bid