Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC 210 A RASHBEHARI AVENUE KOLKATA 700029 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.2 L+₹49,029 (7.26%)Rejected-Finance 24A RABINDRA SARANI KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L2 | Rejected-Finance L2 | |
| 3 | L3₹8.0 L+₹1.2 L (18.1%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹19,857
Closing Date
19 Mar 2025, 12:00 pmClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
AMC of Electrical Works at VYBK -- Replacement of damaged cable, feeder pillar box, light fittings and allied E.I works Near Gate No 1 of VYBK ---- as and when required
2025_WBPWD_826348_1
WBPWD/EE/BED/e-NIQ-108/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
VYBK
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,857
2 Apr 2025
12 Mar 2025
21 Mar 2025
12 Mar 2025
19 Mar 2025
12 Mar 2025
Amount
Supply of 4 Core 16 Sqmm XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / Mescab / Gloster]
Supply of 4 Core 25 Sqmm XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / Mescab / Gloster]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
S & F of IP66, 100W, LED Floodlight at different Entry Gate (Make: Wipro - Ranger Plus | LF30, Model- LF30-112-60L-57-XX / Equivalent) as per direction of EIC.
S & F of IP66, 80W, LED Floodlight at different Entry Gate (Make: Crompton - ROVER PLUS, Model-TFS-504-80-57-60D-SL-GL-NSG / Equivalent) as per direction of EIC.
S & F of 3 Core 2.5 Sqmm PVC Insulated, PVC Sheathed Annealed Copper Industrial Flexible Cables in 20mm size PVC rigid conduit 'FR' (Precision make) as per direction of EIC.
Finishing the end of 2.5 Sqmm cable XLPE/PVC armoured cables by crimping method as per GS.
Making foundation of size 1250mm x 1000mm x 500mm base with plain concrete cement works (Composition of sand, cement, stone with 1:2:4) including 500mm wide brick work with 1st class bricks in cement morter (1:4) to the outer periphery, Plastering of surface upto 20 mm & 1.5 mm thick Neat cement of the foundation for erection of feeder piller as per direction of EIC.
S & F Trner Control unit for 1 Ph AC machines with 12-way SPN DB Box(Mk.- L & T/Crabtree/ kgrand/Siemens/ABB): i) 12 way SPN DB or Timer DB - 1 no. ii) 40A DP MCB Isolator-1 no. iii) Digital 24 hrs.Time switch- 1 no. iv) 32A, 2-pole power contactor-1no v) Centre off 2-way toggle switch - 1 no. vi) 32A Barrier type Terminal -1 no. vii) LED indicating lamp - 1 no. viii) 2x4+1x2.5 Sq.mm Cu wire(Gloster /KEI/RR Kabel)
S & F 18 SWG SS Box 250x200x105 mm fabricated by 16SWG MS Canopy (200 x 168 mm) for rain water protection with One no. 4 way AC/DC terminals, One no. 6A SPMCB in Din Rail with necessary civil works by manpower & materials including connections of electrical cables & wires incl. mending good the damages to original finish & painting with wall matching colour as per direction of EIC.
S & F 50mm dia medium guage GI pipe ( ISI- M) protection with necy. Fittings and jointing materials as required as to G.S.
S & F CI Cable route marker to be erected on grouting using cement concrete, graded stone chips etc. as reqd. as per direction of EIC.
S & Fixing of 72W LED Street fittings (Make: Philips: BRP333 LED110 CW R5C FG PSU S1 V1 / Equivalent) as per direction of EIC.
Connecting 4 SWG GI wire from the Pole to earth Electrode as required and making connection as to GS.
Supplying & fixing earth busbar including Connecting the equipments of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS.
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS
Extra treatment of soil by using salt & charcoal for pipe electrode as to G.S.
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. 20mm size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. i) 3 x 22/0.3 (1.5 sqmm) Note:- (i) Suitable quantity of Common / Regular EI materials like cables, fittings, wire, conduit etc. should be stored at site by the Agency in advance with his own responsibility to overcome emergency situations. (ii) Works through requisition (i.e, Regular work) should be started within 16 hrs & the emergency breakdown works should be started within 4 hrs with requisite manpower after getting the information either from site or from office. Each individual work must be completed with minimum executing time as per site requirement. (iii) The Agency must submit the details of communicating person in this regard along with his Mobile number & Email id.
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
STANDARD BUILDERS (BID ID -6243349)
ANNAPURNA ELECTRICALS (BID ID -6233830)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .