| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L1 | Accepted-AOC M/S Solanki General Suppliers is the Lowest Bidder, hence accepted | |
| 2 | L2₹16.8 L+₹79,923 (5.00%)Rejected-Finance 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹17.9 L+₹2.0 L (12.2%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹18.5 L+₹2.5 L (15.7%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 5 | L5₹18.9 L+₹2.9 L (18.3%)Rejected-Finance 190 B VIJAY BHAWAN SUBHASH CHOWK RATANADA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 Oct 2024, 6:00 pmClosed
Sh Nitish Pathak,EE
GE (AF) Phalodi
REPAIR REPLACEMENT OF UNSERVICEABLE INTERNAL ELECTRIFICATION WORKS AT TECH AREA AT AF STN PHALODI
2024_MES_670995_1
8619/A/E8
Open Tender
Civil Works
Item Rate
240 days
Air Force Station Phalodi
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹40,000
Yes
8 Nov 2024
3 Sept 2024
8 Oct 2024
3 Sept 2024
1 Oct 2024
18 Sept 2024
Amount
Taking down carefully old unserviceable existing copper/aluminium point wiring (light, fan, socket or power) complete including teak wood battens or from existing conduits with all fittings, such as switches, ceiling rose, pendants, sockets, lamp holder, fan regulators, sketch/brackets, light fittings (except tube light fitting) etc but excluding ceiling fan and removal of old material from site and making good disturbed surfaces of walls, floors ceiling etc to match with existing surfaces complete all as specified and directed.
M&L for point wiring for one light point /ceiling fan point controlled by one switch with 1.5 Sqmm PVC insulated, sheathed multi strand copper conductor cable FRLSH 1100 volts in existing concealed/surface conduit for one light point, fan point , controlled by one switch on the same board with other switch or independent including PVC insulated sheathed 1.5 Sqmm multi stranded copper conductor cable FRLSH 1100 volts connected to common earth dolly including 1.25mm thick sunken pressed steel terminal boxes/Modular metal flux box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover complete all as specified and directed. Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A'.
All as per srl item No. 2.00 (here-in-before) but for one 3 pin socket out let 5 Amp on same board.
All as per srl item No. 2.00 (here-in-before) but for one 3 pin socket out let 5 Amp on independent board.
All as per srl item No. 2.00 (here-in-before) but for call bell point.
All as per srl item No. 2.00 (here-in-before) but for but one light point controlled by two switches two way.
All as per srl item No. 2.00 (here-in-before) but for 15 Amp socket out let by using 2.5 Sqmm PVC insulated sheathed copper conductor cable FRLSH multi strand on independent board including provn of 2.5 Sqmm unsheathed, multi stranded copper conductor cable FRLSH continues as earth wire connected to earth dolly etc complete all as specified and directed.
M&L point wiring for one light point /ceiling fan point controlled by one switch with 1.5 Sqmm PVC insulated, sheathed multi strand copper conductor cable FRLSH cable 1100 volts into concealed PVC conduit 20 mm dia, medium duty, ISI marked including all fittings and fixture accessories including 1.25mm thick sunken pressed steel terminal boxes/Modular metal flux box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for one light point, fan point , controlled by one switch on the same board with other switch or independent including PVC insulated sheathed 1.5 Sqmm multi stranded copper conductor cable FRLSH 1100 volts connected to common earth dolly for fixing of modular switch,sockets etc complete all as specified and directed. Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A'.
All as per srl item No. 8.00 (here-in-before) but for one 3 pin socket out let 5 Amp on same board.
All as per srl item No. 8.00 (here-in-before) but for one 3 pin socket out let 5 Amp on independent board.
All as per srl item No. 8.00 (here-in-before) but for call bell point.
All as per srl item No. 8.00 (here-in-before) but for 15 Amp socket out let by using 2.5 Sqmm PVC insulated sheathed copper conductor cable FRLSH multi strand on independent board including provn of 2.5 Sqmm unsheathed, multi stranded copper conductor cable FRLSH continues as earth wire connected to earth dolly etc complete all as specified and directed.
M&L for point wiring for one light point /ceiling fan point controlled by one switch with 1.5 Sqmm PVC insulated, sheathed multi strand copper conductor cable FR-LSH 1100 volts including PVC casing caping size 20/25mm including suitable size PVC box with cover plate for fixing switch/socket flush to surface for one light point, fan point , controlled by one switch on the same board with other switch or independent including PVC insulated sheathed 1.5 Sqmm multi stranded copper conductor cable FR-LSH 1100 volts connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A'.
All as per srl item No. 13.00 (here-in-before) but for one 3 pin socket out let 5 Amp on same board.
All as per srl item No. 13.00 (here-in-before) but for one socket point outlet 3 Pin, 5 Amp 230 Volt on independent board.
All as per srl item No. 13.00 (here-in-before) but for call bell point.
All as per srl item No. 13.00 (here-in-before) but for 15 Amp socket out let by using 2.5 Sqmm PVC insulated sheathed copper conductor cable FRLSH multi strand on independent board including provn of 2.5 Sqmm unsheathed, multi stranded copper conductor cable FRLSH continues as earth wire connected to earth dolly etc complete all as specified and directed.
S&F switch piano flush type, 6 Amp 240 Volt, AC one way etc complete all as specified and directed.
S&F switch piano flush type, 16 Amp 240 Volt, AC one way etc complete all as specified and directed.
S&F socket outlet flush type 5 pin 16 Amp, 230 volts AC complete all as specified and directed.
S&F flush type socket outlet 5 Pin 6 Amp, 230 volts AC complete all as specified and directed.
S&F switch socket combination 2 in 1, 5 pin , 6 Amp, flush type complete all as specified and directed.
S&F switch socket combination 5 pin 16 Amp, flush type complete all as specified and directed.
S&F Ceiling fan regulator flush type electronic step socket type , 230V complete all as specified and directed.
S&F bell push, flush type 6 Amp, 230 V complete all as specified and directed.
S&F switch piano flush type, 6 Amp 240 Volt, AC two way etc complete all as specified and directed.
S&F ceiling rose surface polycarbonate 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F batten holder 2 Amp 240 volt AC with skrit ISI marked top line series , PVC /polycarbonet cased body of brass with back plate suitable for abtten fittings with LED bulb 9/10 Watt B22 base 6000K complete all as specified and directed.
S&F in renewal call bell ding dong type, AC, 230 V etc complete all as specified and directed.
S&F in renewal LED batton fitting 1 x20/22 Watt, 220 V decorative box type with driver 4" complete fitting connection with 3 core flexible copper cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed.
S&F in renewal LED light fitting 9/10 Watt 2 feet mirror light luminarire with poly carbonate cover complete with all acessories and driver including connections with with 3 core copper wire of suitable size complete all as specified and directed.
S&F in renewal LED light fitting, 1X25 watt, complete with tuff net glass protection IP:66, fixed to walls with GI bracket made out of suitable size of light grade pipe 32 mm dia tubing upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of 25x3 mm MS flat iron with suitable bolt and nuts and testing etc complete all as specified and directed.
S&F in renewal LED Ceiling light square recessed mounted LED flat panel complete 600mm x 600mm, 230 volts 35/36 Watt LED light fixing on Surface/ceiling and connecting with 3 core copper conductor FR-LSH cable etc complete all as specified and directed.
S&F in renewal LED Ceiling light circular recessed mounted/ Surface mounted LED flat panel complete, 230 volts 12 Watt LED light fixing on wall/ceiling and connecting with twin core copper conductor FR-LSH cable etc complete all as specified and directed.
S&F in renewal LED flameproof light Flame proof 1X16 Watt, 4' long with die cast alluminium housing with heat resistance toughten glass with LED tube light fixture driver, holder, connector etc prewired including connecting up with 3 core copper cable in steel flexible pipe complete all as specified and directed.
S&F in replacement of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board single pole & neutral 240 volts 2 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete including taking down old complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board single pole & neutral 240 volts 4 way with IP-43 IK-09 protection double door complete with minimum capacity 200 Amp bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification including taking down old complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification including taking down old complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification including taking down old complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board triple pole & neutral 415 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification. including taking down old complete all as specified and directed.
S&F in renewal Isolator FP 125 Amps C curve MCB repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal Isolator TPN 100 Amps C curve MCB, 240 V repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB TPN 63 Amps C curve MCB, 240 V repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB TPN 40 Amps C curve MCB, 240 V repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB SPN 63 amp C curve MCB, 240 V repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB SPN 40 amp C curve MCB, 240 V repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB 6 Amp to 32 Amp SP capacities 'C' series, 240 V, 10KA rupturing capacaity complete all as specified and directed.
M&L for Sub main wiring with 2 runs of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through existing surface/recessed steel/PVC conduit on wall/roof and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through existing surface/recessed steel/PVC conduit on wall/roof and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through existing surface/recessed steel/PVC conduit on wall/roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 25mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 25mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 25mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 4 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 32mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Four runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC conduit of 32mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 4 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 32mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Four runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit of 32mm dia shall be measured and paid as one unit length.
S&F modular type switch piano type, 6 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed.
S&F modular type switch piano type, 16 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed.
S&F modular type switch piano type, 6 Amp 240 Volt, AC (ISI Marked) two way etc complete all as specified and directed.
S&F modular type bell push switch , 6 Amp 240 Volt, AC (ISI Marked) two way etc complete all as specified and directed.
S&F modular one socket outlet 5 Pin 5 Amp 230 volts AC complete all as specified and directed.
S&F modular one socket outlet multipurpose 3 Pin 5 Amp and 6 Pin 15 Amp 230 volts AC complete all as specified and directed.
S&F modular Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed.
S&F in renewal modular white cover plate with frame, 2 module complete all as specified and directed.
S&F in renewal modular white cover plate with frame, 3 module complete all as specified and directed.
S&F in renewal modular white cover plate with frame, 4 module complete all as specified and directed.
S&F in renewal modular white cover plate with frame, 6 module complete all as specified and directed.
S&F in renewal modular white cover plate with frame, 8 module complete all as specified and directed.
S&F in renewal switch piano flush type, 6 Amp 240 Volt, AC one way etc complete all as specified and directed.
S&F in renewal switch piano flush type, 16 Amp 240 Volt, AC one way etc complete all as specified and directed.
S&F in renewal socket outlet flush type 5 pin 16 Amp, 230 volts AC complete all as specified and directed.
S&F in renewal flush type socket outlet 5 Pin 5 Amp, 230 volts AC complete all as specified and directed.
S&F in renewal switch socket combination 2 in 1, 5 pin, 5 Amp, flush type complete all as specified and directed.
S&F in renewal switch socket combination 5 pin 16 Amp, flush type complete all as specified and directed.
S&F in renewal Ceiling fan regulator flush type electronic step type , 230V complete all as specified and directed.
S&F in renewal switch piano flush type, 6 Amp 240 Volt, AC two way etc complete all as specified and directed.
S&F in renewal bell push, flush type 5 Amp, 230 V complete all as specified and directed.
S&F in renewal ceiling rose surface polycarbonate 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F in renewal Lamp holder of PVC / Polycarbonate type for batten fittings surface all as specified and directed.
S&F in renewal call bell ding dong type, AC, 230 V etc complete all as specified and directed.
S&F in replacement of unserviceable/broken Bakelite hylum sheet of size (8"X10") with suitable screw etc complete all as specified and directed.
S&F in replacement of unserviceable/broken Bakelite hylum sheet of size (7"X4"). with suitable screwetc complete all as specified and directed.
S&F in replacement of unserviceable/broken Bakelite hylum sheet of size (10"X12") with suitable screw etc complete all as specified and directed.
S&F in replacement of unserviceable/broken Bakelite hylum sheet of size (4"X4") with suitable screw etc complete all as specified and directed.
S&F in replacement of unserviceable 25 mm width heavy duty double lock press type casing & caping ISI marked fixed to wall /ceiling using screws of suitable size including removing the existing for replacement complete all as specified and as directed.
S&F in replacement of unserviceable 40 mm width heavy duty double lock press type casing & caping ISI marked fixed to wall /ceiling using screws of suitable size including removing the existing for replacement complete all as specified and as directed.
S&F in replacement of unserviceable 6 Sqmm aluminium service wire 2 core fixed to wall/ceiling using clamps of suitable size including removing the existing for replacement complete all as specified and as directed.
S&F in replacement of unserviceable 4 Sqmm aluminium service wire 2 core fixed to wall/ceiling using clamps of suitable size including removing the existing for replacement complete all as specified and as directed.
S&F in replacement 3 pin 15 Amps Plug Top 250 Volts heavy duty complete all as specified and as directed.
S&F in replacement 3 pin 5 Amps Plug Top 250 Volts heavy duty complete all as specified and as directed.
S&F in renewal PVC Rectangular box with 5A flush type 2 in 1 switch socket combination complete all as specified and directed.
S&F in renewal PVC Rectangular box with 15A flush type 2 in 1 switch socket combination 240 V complete all as specified and directed.
S&F in replacement of unserviceable aviation obstruction light die-cast aluminium alloy housing,red coloured polycarbonate dome and accessories complte all as specified and directed.
S&F in replacement LED inverter batton fitting 1 x18/20 Watt, 220 V decorative box type with driver 4" complete fitting connection with 3 core flexible copper cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed.
S&F earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burred in ground vertically earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of GI nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate upto 5 mtr and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 using 20mm stone aggregates for earthing pit, 10mm thick cast iron cover with angle iron frame and shown in electrical plate No 3 of SSR Part-I and testing on complete including dismantling old earthing all as specified and directed. Note: (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item. (ii) The unit rate includes for protection pipe and GI wire 4mm from top of earth plate up to 7.5 meter above ground level.
M&L for Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6.3 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized GI strip 25X4mm by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion including dismantling of old earth plate complete all as specified and directed. Note: (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item. (ii) The unit rate includes for protection pipe and GI strip 25 x 4mm from top of earth plate up to 7.5 meter above ground level.
M&L for chemical earthing complete with copper earth plate 600 mmx600 mm x3.15 mm thick buried directly in ground earth plate not less than 3.0 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including copper strip 20x3mm by means of bolts, nuts, check nuts and washers of copper/brass including providing of alternate layer from bottom edge to 30cm above top edge of earth plate by chemical fill compound, ground enhancing material, earth powderand after that 1 m back of layer of charcoal dust and common salt including PCC pit in PCC (1:2:4) type B-1using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle including excavation and earth work in any type of soil and medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 40mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion including dismantling of old earth plate complete all as specified and directed. Note: (i) Excavation, earthwork, charcoal, PCC pit is covered under this item. (ii) Contractor shall be produced the result of earth below 1 Ohm othrewise earthing will not be acceptable.
S&F in repair Adjustable thermal & Adjuatable magnetic setting MCCB four pole 160 Amps, 36 KA rating, 415 volts AC complete all as specified and directed.
S&F in repair Adjustable thermal & Adjuatable magnetic setting MCCB four pole 63 Amps, 16 KA rating,Ics=75% Icu ,415 volts AC complete all as specified and directed. Note for Ser Item No 1.00 to 99.00:- (a) Contractor either himself or his accredited agent shall collect the day to day complaint slip from concern JE in the morning daily and deposit the same after complaince duly signed by user's/complainant. (b) Contractor will provide suitable transportation for attanding daily basis complaint on site like Cycle/Motorcycle etc to each Electrician/helper with proper driving licence/halmet etc and keep permission of vehicle for inside premises by comptent authority. (c) Contractor will resposible forsaftey of the tradesman employ by them. (d) Contractor will provide equipment like tester, test lamp, Multi metre, cutting plier, screw driver, plier, electric hammer, drill machine, electrical wall cutting machine, wiring steel wire etc on his own arrangement for rectifying the complaint and also screw, nut, bolt, insulation tape as per site requirement and extra payment shall be made on this account. (e) Contractor fails to attend the complaints of normal nature within 24 Hrs and urgent nature within 2 hrs he shall be lavied penalty of Rs 500/- per complaint per day. (f) Nature of complaints either urgent or normal shall be decided by the Engineer-in-charge. (f)
Mahaveer Traders (BID ID -3122680)
KRISHNA CONSTRUCTION COMPANY (BID ID -3102967)
star electricals (BID ID -3124151)
M/S Balkishan Panwar Construction (BID ID -3122957)
YOG INFRA (BID ID -3102192)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .