Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | ₹26.0 L Quoted ₹26.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹29.2 L+₹2.7 L (10.3%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹29.2 L+₹2.7 L (10.3%) | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 3 | L3₹30.7 L+₹4.2 L (16.0%)Rejected-Finance | ₹30.7 L+₹4.2 L (16.0%) | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 4 | L4₹36.1 L+₹9.6 L (36.1%)Rejected-Finance | ₹36.1 L+₹9.6 L (36.1%) | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
2 Apr 2024, 6:00 pmClosed
GE (AF) Chiloda
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
REPAIR/ MAINT OF STREET LIGHTS, INTERNAL ELECTRIFICATION IN MD/ OTM ACCN AT AREA A AND C AT AF STN WADSAR
2024_MES_645552_1
8132/24-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
WADSAR
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹70,000
Yes
8 Jun 2024
7 Mar 2024
4 Apr 2024
7 Mar 2024
2 Apr 2024
21 Mar 2024
7 Mar 2024 - 20 Mar 2024
Amount
M&L including taking down for concealed sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and in existing conduit pipe including one run of 4.0 Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green colour complete all as specified and as directed. Note- (a) Two runs of single core cable with one run of earth continuity cable will be measured and paid as one unit. (b) Make disturbed surface good to wall/floors .
All as per Item No 1.00 here in before but with 6 Sqmm.
All as per Item No 1.00 here in before but with 4 Sqmm and in PVC casing capping with all asscessories.
M&L including taking down for concealed point wiring complete with FRLS PVC insulated /unsheathed stranded copper conductor of wire 1.5 Sqmm , 1100 volt grade , alongwith one single core of same size stranded copper as continuous earth wire to common earth dolly, drawn through in existing conduit pipe fixed in concealed surface of wall/ceilling/false ceilling including cutting /chasing in wall as required with powder coated sheet metal terminal boxes of required sizes and thickness (factory made) sunk in wall only with 3.0mm thick laminated sheet where as required and accessories suitable for One light/fan point controlled by one, one way switch complete all as specified and as directed.
All as per item No. 04 here-in-before but one socket outlet 05 Amps on the same board
All as per item No. 04 here-in-before but one socket outlet 05 Amps on independent board
All as per item No. 04 here-in-before but one bell/buzzer point controlled by on bell push
All as per item No. 04 here-in-before but one light point controlled by two 2- way switches
All as per item No. 04 here-in-before but point wiring with 2.5 Sqmm cable and 2.5 Sqmm earth continuity conductor for 3 pin 15 Amp socket and complete all as specified and as directed.
M&L including taking down for point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) through and including 20X12 mm PVC casing-n- copping and its accessories, cadmium screws and including 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick for housing suitable for one light/fan point controlled by one on way switch complete all as specified and as directed.
All as per item No. 10 here-in-before but one socket outlet 05 Amps on the same board
All as per item No. 10 here-in-before but one socket outlet 05 Amps on independent board
All as per item No. 10 here-in-before but one bell/buzzer point controlled by on bell push
All as per item No. 10 here-in-before but point wiring with 2.5 Sqmm cable and 2.5 Sqmm earth continuity conductor for 3 pin 15 Amp socket and complete all as specified and directed.
M&L including taking down for flame proof point wiring complete using colour code with two run of 1.5 Sqmm single core multi-stranded copper conductor ZHLS PVC insulated and unsheathed multistrandard copper conductor cable 1100 V grade conforming to IS-694 drawn through and including ERW steel conduit 20 mm dia (external flame froof) heavy grade (IS Marked) including necessary all accessories/fixtures , concealed in wall , ceiling including sunken type pressed steel terminal boxes with flame retardant sheet of approved shade 3 mm thick including providing continuous earth wire with one single run of 1.5 sq mm single core mult-stranded copper conductor ZHLS, PVC insulated and unsheathed cable 1100 volts grade conforming to IS 694 for one light point controlled by one way flame proof switch etc , complete all as directed by Engineer-In-Charge. Note : The cost of cutting chases in wall /floor/ceiling wherever required and making good the surface as exists shall be deemed to be included in respective items of schedule.
S&F in repair of LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vaporgroup of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
S&F in repair of Flame proof and weather proof single pole rotary/cam switch on-off with direct entry single pole 16A on-off in AL LM-6, 230V complete all as specified and as directed.
S&F in repair 2 way sheet metal enclosures for flush/surface mounting distribution board Single door, 240 volts without bus bar complete all as specified and as directed.
S&F in repair 4 way sheet metal enclosures for flush/surface mounting distribution board double door, 240 volts factory made and tested complete, suitable for mounting MCBs with 200 Amps rated bus bar, cable lugs complete all as specified and directed.
All as per item No. 19 here-in-before but 8 way
All as per item No. 19 here-in-before but 12 way
All as per item No. 19 here-in-before but 4 way 415 volts TPN DB
M&L including taking down for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick electrode, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to 4 mm dia galvanized earth wire by means of bolts, nuts, check-nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 (duly protected with 15 mm dia light grade GI pipe upto 7.5m from the earth plate) and connected to GI steel earth plate including charcoal, dust, common salt, necessary excavation in soft/loose soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m from the starting point, watering pipe 20 mm bore GI tube of light grade treated with 1 No PGI funnel, pit of PCC 1:2:4 type B-1/ RCC 1:2:4 type B-1, pit cover 75 mm thick reinforced with 6 mm dia bars @ 75 mm c/c both ways and with MS handle 12 mm dia connected to earth test point including testing complete all as specified and directed.
All as per item No. 23 here-in-before but with GI strip 25 x 4 mm size.
S&F in repair of miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP 240V, 10 KA 'C' curve, in the DB Complete with connection testing and commissioning complete all as specified and as directed.
All as per item No. 25 here-in-before but SP 5 To 32 AMP
All as per item No. 25 here-in-before but SPN 32 AMP
All as per item No. 25 here-in-before but SPN 40 to 63 AMP
All as per item No. 25 here-in-before but TPN 40 to 100 AMP capacity ,415 volt.
S&F in repair 40 Amps RCBO A-type (TPN-4M) 240/415 Volt, 50 Hz , 10 KA short circuit capacity and breaking capacity 100 mA complete all as specified and as directed.
Repair/Maint of day to day complaints (light /bell /ceiling fan / exhaust fan / switch and socket any type / geysers point etc.) by using following spare parts to rectify the defects and make serviceable with or without replacing spare parts and all as per the direction of Engr- in - charge. (Contractor shall provide appropriate technician and labour on daily basis. Fixing charges against each item are included with that item.)
S&F in reapir Switch piano, single pole one way 5 Amps 240 volt capacity flush type complete all as specified and as directed.
S&F in repair Switch flush type, 05 Amp single pole, two way complete all as specified and as directed.
S&F in repair 3 pin 5 Amps Socket outlet , flush type complete all as specified and as directed.
S&F in repair bell push piano type, single pole one way 5 Amps 240 volts capacity flush type complete all as specified and as directed.
S&F in repair an electric bell ding dong AC 230 volt single pole complete all as specified and as directed.
S&F in repair 5 pin, 5 Amps switch & socket combination flush type multipurpose 3 pin, 5 Amp flush type universal complete all as specified and as directed.
S&F in repair 3 pin 15 Amps switch socket combination, flush type multi purpose 2 in 1 type (3 pin 5 Amps and 15 Amps) complete all as specified and as directed.
S&F in repair 3 pin 15 Amps switch socket combination, flush type multi purpose 2 in 1 type including PVC mounting box (3 pin 5 Amps and 15 Amps) complete all as specified and as directed.
S&F in repair 5 pin, 5 Amps switch & socket combination flush type multipurpose 3 pin, 5 Amp flush type universal including PVC mounting box complete all as specified and as directed.
S&F in reapir Switch piano, single pole one way 15 Amps 240 volt capacity flush type complete all as specified and as directed.
S&F in repair 6 pin 15 Amps Socket outlet , flush type complete all as specified and as directed.
S&F in repair ceiling rose, 5 Amps surface type 240 volts bakelite three terminal as ordered and directed.
S&F in repair fan regulator electronic step type 230 volts switch type suitable for any type of ceiling fan sweep complete all as specified and as directed.
S&F in repair fan regulator electronic step type 230 volts socket type suitable for any type of ceiling fan sweep complete all as specified and as directed.
S&F in repair modular switch, one way, 6 Amps, 1 module, ISI marked complete all as specified and as directed.
S&F in repair modular socket, 6 Amps - 2/ 3 pin combined 2 module, ISI marked complete all as specified and as directed.
S&F in repair modular socket, 6/ 16 Amps - 2/ 3 pin combined 2 module, ISI marked complete all as specified and as directed.
S&F in repair modular switch, one way, 16/ 20 Amps, 1 module, ISI marked complete all as specified and as directed.
S&F in repair modular switch, two way, 6 Amps, 1 module, ISI marked complete all as specified and as directed.
S&F in repair modular bell push, 6 Amps, 1 module, ISI marked complete all as specified and as directed.
S&F in repair modular fan step regulator, 120 W - 1 module, ISI marked complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 2 module, ISI marked complete all as specified and as directed.
All as per item No. 31.22 here-in-before but, 3 module
All as per item No. 31.22 here-in-before but, 4 module
All as per item No. 31.22 here-in-before but, 6 module
All as per item No. 31.22 here-in-before but, 8 module
All as per item No. 31.22 here-in-before but, 12 module
S&F in repair on wall , Plug and socket in sheet steel enclosure with Songle pole & earth , suitable for 20 Amp with providing MCB SP 20 Amp suitable for single phase AC supply complete all as specified and as directed.
S&F in repair holder brackets/angle suitable for any type of lamp (as per sample ordered) complete all as specified and as directed.
S&F in repair 09 to 12 watt ball type LED lamp complete all as specified and as directed.
S&F in repair Flexible PVC pipe of 25mm bore for passing the cable complete all as specified and as directed.
S&F in repair of LED batten fitting alongwith removable LED Tube 20W, 230 Volt, wall /ceiling mounted with phase and nuetral leads on single side of rod complete all as specified and directed.
S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V complete all as specified and directed.
S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type complete all as specified and directed.
S&F in repair round shape recess mounted cap 10/12 watt 220 volts AC recessed type complete all as specified and as directed.
S&F in repair LED light fitting 1x10W bulkhead luminaires complete all as specified and directed.
S&F in repair Polycarbonate retrofit LED tube rod of 20 W rod with phase and nuetral leads on single side of rod complete all as specified and directed.
Taking down ceiling fan / exhaust fan / wall mounted fan / Exhaust/cabin fan of any sweep and refixing/hanging the fan after repairing/servicing duly cleaned and greased complete all as specified and directed. Note- Replacement of any parts will be measured and paid seperately.
Rewinding of cabin /pedastal fan, wall mounted fan/pvc ventilating fan with new super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton tape sleeves, varnish, reassembling, testing and commencing for satisfactory run, complete all as specified and directed by Engineer in Charge.
All as per item No 39.00 above, but rewinding of 300-450 mm sweep exhaust fan any type.
S&F in repair of fan capacitor/condensor 2.5- 4 MFD, 240 volt of ceiling fan/exhaust fan/wall mounted fan complete all as specified and as directed.
Supply only of ball/bush bearing of original/existing size suitable for any type of fan against item ser no 38.00 above.
S&F in repair flexible cord of 230 volt grade,size 0.50 sqmm two core, multi stranded copper conductor complete all as specified and directed.
S&F in repair of nut and bolt (not less than 2.5 inches) and 0.25 inches dia with suitable size rubber reel for hanging of ceiling fan complete all as specified and directed.
M&L for preparation of old painted surfaces of any type fans ceiling/exhaust/cabin/wall/pedastal fans complete, in-situ with synthetic enamel paint with existing colour by using spraying gun including filling cavities with filler, one coat after cleaning all dust etc. complete against item ser no 38.00 above.
Supply only of blades of ceiling/exhaust/wall/cabin/pedastal fans any type/size made of aluminium/ms or existing metal against item ser no 38.00 above.
S&F in repair of louvers suitable for 300-450mm sweep exhaust fan complete all as specified and as directed.
Supply and fixing in repair (BLDC) ceiling fans complete with blades, down rods with remote control unit with battery 02 Nos and accessories 230 V, 1200 mm sweep Min air delivery 240 cu m/min with service value 6.00 BEE Five star rated with brushless direct current motor complete all as specified and directed.
Taking down and refixing carefully water of storage type water heater of 25/15/35/50 ltrs capacity of any make complate all as specified and directed.
M&L for grouting in walls, making hole, fixing of suitable type of bolts, nuts and washers including installation of water heater of any capacity in suitable places, complete all as specified and directed.
S&F in repair inner tank assembly for any type and capacity of water heater geyser complete all as specified and as directed.
S&F in repair inner tank made out copper for any type and capacity of water heater geyser complete all as specified and as directed.
S&F in repair heating element of existing type/capacity for 50/35/25/15 ltrs cap geyser complete all as specified and as directed.
S&F in repair of thermostat of existing type/capacity for 50/35/25/15 ltrs cap geyser complete all as specified and as directed.
S&F in repair of indicator neon of existing type/capacity for 50/35/25/15 ltrs cap geyser complete all as specified and as directed.
S&F in repair PVC connections of 15 mm dia suitable for hot & cold water 450 mm long with brass nuts and rubber washers complete all as specified and directed.
S&F in repair safety pressure valve of size 15 mm dia, ISI marked for geysers, complete all as specified and as directed by Engineer-in-charge.
M&L for servicing of 100 LPD solar water system (evaculated tube collector type) and maintenance of complete solar water heating system for carrying out minor leakage,cleaning of sintex tank incl dismantling inlet and out let connections and re-fixing the same after cleaning for proper functioning to maintain proper water temperature, complete all as specified and as directed by Engr-in-Charge.
S&F in repair of solar water heater silicon 'O' rings for 100 LPD capacity complete with all accessories as required at site and as directed by Engineer in charge.
S&F in repair of ETC glass Tube 47mm/1500 mm including connected accessories etc complete all as specified and directed by Engineer-in-charge.
S&F in repair heating element for solar heater tank ISI marked complete with rubber gasket including replacing the bolts if any broken during changing the heating elements complete all as directed by Engineer-in-Charge.
S&F in repair PVC wire 1.5 sqmm 3 Core PVC insulated cable copper drawn through PVC conduit from looping box to street light fitting terminal complete all as specified and directed.
S&F in repair 15 mm bore Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair of blocking misting nozzles for air cool flow cooling system complete all as specified and directed.
S&F in repair of water pump for air cool flow cooling system complete all as specified and directed.
Rewinding to pressure pump for misting nozzles suitable gauage of copper winding wire with insulation materials complete all as specified and directed.
Repairing/cleaning of nozzles with suitable cleaning chemical for air cool flow cooling system complete all as specified and directed.
S&F in repair of mist fan motor for air cool flow cooling system complete all as specified and directed.
S&F in repair 15 mm Stop valves, cast copper alloy,screwed down,high pressure,with crutch or butterfly handle,screwed both ends for Hot water/Cold pvc pipe complete all as specified and directed.
S&F in repair of air plug suitable for any type capacity of water heater complete all as specified and directed.
S&F in repair Weather proof flat twin core auminium cable 1.5 sqmm complete all as specified and directed.
S&F in repair Weather proof flat twin core auminium cable 2.5 sqmm complete all as specified and directed.
S&F in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing with IP 65/66 protection complete all as specified and directed.
All as per item No. 73 here-in-before but 70 watt
S&F in repair LED flood light 70 watt 230 V AC outdoor type with high pressure die cast aluminum hosing with IP 65/66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
All as per item No. 75 here-in-before but 100 watt
All as per item No. 75 here-in-before but 120 watt
All as per item No. 75 here-in-before but 170 watt
All as per item No. 75 here-in-before but 210 watt
S&F in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
All as per item No. 80 here-in-before but 40 watt
S&F in repair Copper ballast HPSV/MH 250-400 watts as per existing type and model for street light/gate light/search light complete all as specified and as directed.
S&F in repair Lamp HPSV/MH 250-400 watts as per existing type and model for street light/gate light/search light complete all as specified and as directed.
S&F in repair Igniter electronic 250-400 watts for SV/MH lamp as per existing type and model for street light/gate light/search light complete all as specified and as directed.
S&F in repair porcelain holder for 250 -400 watt as per existing type and model for street light/gate light/search light complete all as specified and as directed.
S&F in repair of mounting bracket forming 'L' shape having an interior angle of 120 degree or existing type and size installed at site made out of GI pipe light grade 50 mm dia for fixing to street light fittings on the poles not less than 1.5 meter long duly painted with aluminium paint two coats complete all as specified and directed.
S&F in repair of contactor ML 1.5, 3 pole, 415 V complete all as specified and as directed.
S&F in repair of looping box (enclosures) of size 280 x 170 x 130 mm made of PVC comprising of 02 Nos aluminium bus bar 100 Amps rating fixed on porcelain insulators, earthing terminal and one MCB SP 6/16 Amp including MS bracket, nut an bolts complete all as specified and directed.
S&F radium sticker of red colour, water proof 80 mm wide on around the poles complete all as specified and as directed.
M&L for preparation of old steel surfaces with one coat of spray painting of feeder pillar (Kiosk) externally with synthetic enamel paint of approved tint complete all as specified and directed.
M&L for painting steel tubular poles 9/11m height including brackets and cross-arms if any and applying one coat of synthetic enamel paint of existing colour Including writing of MES No complete all as specified and directed.
Supply and laying or fixing in repair XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (H/D) earthed cable aluminium conductor, 1100 volts grade with standed complete all as specified and directed for 10 sq. mm, 2 core nominal cross section in service connections complete all as specified and as directed.
All as per item No. 92 here-in-before but of cable size 16 Sqmm , 2core
M&L for excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc. and getting out soft/ loose soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25cm complete all as specified and directed.
Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Supply and laying in repair of DWC HDPE pipe of SN4 category confirming to IS 14930 Part I and II including accessories like HDPE snap fit coupler with neoprene 'O' ring of 38 mm inner dia complete all as specified and as directed.
S&F in repair of driver (circuit) suitable for 25/30/50/72/90 watt LED fittings complete all as specified and as directed. Make:- Havells or equivalent as approved by GE.
S&F in repair of NATURE SWITCH-02 (sensor along with pre-dawn switching off timer, 4-8 hrs) & NS-INDOOR (sensor for Lux level based switching of outdoor/semi-indoor lights) complete all as specified and as directed. Make:- Nature switch/HPL/L&T/EE or equivalent as approved by GE.
S&F in repair of IP-65 aviation obstruction light, die cast aluminium housing, red coloured polycarbonate dome and Power consumption 5.8 Watt operating temperature 10-60 degree C LED type with lamp and connection complete all as specified and directed.
S&F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed.
S&F in repair electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed.
All as per item No. 102 here-in-before but 3 Phase, 415 volt.
S&F in repair errecting of PCC poles with cast iron base plate, finial taper plug, bolts, nuts & screws asspecified type 410 SP-32 (9.0metres long) duly painted internally complete and externally painted with two coats of bituminious paint with two coat of aluminium paint alongwith cap type single arm bracket 1.5 mtr long of size 40 mm dia and providing nuts & bolts incl demolation of old PCC poles complete all as specified and directed. Note: Earth work /excavation / PCC shall be measured and paid separately.
S&F in repair garden light 8 W LED height 30 inches ,suitable for architectural outdoor light with providing PCC 1:3:6 type C1 foundation & earth work complete so as to fix it properly complete all as specified and directed by Engr in charge. Note : Earth work and PCC will be measured and paid separately against BOQ item. Make : Havells, Bajaj ,Philips,Orient or equivalent as approved by GE.
Disconnecting and taking out 3 Phase forward and reverse motor of capacity 1.0/1.5 HP motor from existing highmast tower enclosure including rewinding with super enameled copper wire, replacement of neck rings, sleeves bushing , seal complete all as specified and directed.
Disconnecting and taking out forward and reverse motor of capacity 1.0/1.5 HP motor from existing highmast tower enclosure including Servicing , testing & commissioning at same place complete all as specified and directed.
S&F in repair of Programmable Time Switch 24 Hour (SST - 15 min) outdoor/semi-indoor lights) for high mast tower controller panel same as per the sample in the existing High mast panel complete all as specified and directed. Make:- Nature switch or equivalent as approved by GE.
S&F in repair bus bar chamber of raing 100 Amps TPN factory made dust and vermin proof including bus bar of rectangular cross section of copper strip supported on cast epox insulator at suitable interval heat shrinkable sleeves with powder colour code 01 set of 04 strip of complete with grouting in wall with suitable FI strip bend to shape with PCC work for holding enclouse and complete all as specified and directed. Make: Havells, cat part No IHBB010004, 4 way or equivalent as approved by GE.
M&L for providing PCC 1:4:8, type D-2, using 40 mm graded stone aggregate as in foundation for erection of poles/ stay assembly complete all as specified and as directed by Engineer-in-charge.
M&L for providing PCC 1:3:6, type C-1 using 20 mm graded stone aggregate as in coping to pole etc. including necessary form work complete all as specified and as directed by Engineer-in-charge.
M & L for boring of holes up to 80 mm dia under road pavement, hard standing, etc by trench- less technology using ultra sound technique complete all as directed by Engineer-in- charge. Note:- Pipe for protection of cable shall be measured and paid separately.
Supply and fixing in repair GI pipe Light grade 50 mm bore (ISI marked) laid in trenches/ path /road crossings/ fixed to poles/ceiling/ along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge. (Note:- Necessary excavation and earth work shall be measured and paid for separately)
All as per item No. 113 here-in-before but 80 mm bore.
supplying,installing,testing and commissioning in replacement of indoor type totally enclosed weather ,dust & vermin proof CPRI approved factory made LT wall mounted meter panel board 415 volt, 3 phase, 4 wires,AC,50 Hz fabricated from 2.00 mm thick CRCA sheet steel and epoxy powder coating in RAL 7032 shade with seven tank treatment process,front opening hinged door with a fully transparent cover made of polycarbonate/high grade engineering plastic to permit clear view of display,locking arrangement,copper busbar 20 mm x 5 mm insulated with heat shrinkable sleeves, appropriate space for fixing single phase energy meter 05 Nos upto 40 amps,40 mm x 40 mm x 6 mm size angle iron frame,hold fast/fastener/bolts/copper lugs/spacers/terminal blocks,rubber gasket,locking knobs,phenolic laminated sheets for live isolation ,heat shrinkable sleeves, nuts,bolts,washers,connections from MCCB to busbar,busbar to meter & meter to MCB with single core copper cable of size 10 sqmm connection , R- Y-B LED indications to show 3 phase availability at incomer including the following :- (i) One number MCCB 63 Amps, 415 volts, 4 pole, 16 KA, thermally adjustable between 70 to 100 % all as per legrand cat Ref no-4200 03 or equivalent as approved by GE. (ii) Temper proof electric meters single phase -05 Nos (Refixing the existing) only alongwith sealing, making sticker of Qtr No in suitable size for identification etc all as directed by engr -in charge) (iii) Five numbers MCB DP 32 Amp,10 KA, 'C' series as approved (one number in each outgoing side of meter)
S&F in repair PVC Ventilator Fans of 300mm sweep with louvers and accessories complete all as specified and directed.
ALBA AC AND REF SERVICES
SANVI ASSOCIATES
BABUBHAI BHIMABHAI PANDAVADRA
Bidder Name
ARTI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .