Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC VILL POST BARANACHINA PS DINHATA DIST COOCH BEHAR 736135 | COOCHBEHAR | WEST BENGAL | 736135 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹35.4 L+₹4.1 L (13.1%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹51.3 L+₹20.0 L (63.7%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
25 Feb 2022, 6:00 pmClosed
GE (SOUTH) BINNAGURI
GE (SOUTH) BINNAGURI, PO - BINNAGURI, DISTT - JALPAIGURI, PIN - 735232
REPAIR/MAINT OF INTERNAL WIRING AND LT OH LINES, LT UG CABLE, PANEL BOARD, EARTHING AND ALLIED WORKS AT HASIMARA MIL STATION UNDER GE(S) BINNAGURI
2021_MES_488061_3
8467/E8
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) BINNAGURI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (SOUTH) BINNAGURI
₹64,000
Yes
23 Mar 2022
12 Feb 2022
28 Feb 2022
12 Feb 2022
25 Feb 2022
12 Feb 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M&L point wiring complete with FRLS PVC insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including 20mm dia 'medium grade' PVC concealed conduits and fittings, including cutting chasing in brick wall n.exc 10cm width or girth(excluding ceiling surface), pressed steel concealed terminal switch boxes not less than 1.2mm thick of required size factory made duly painted inside and outside with two coats of black bituminous paint over one coat red oxide primer, 3mm thick plastic laminated sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including making good disturbed surfaces with CM(1:4) with treating the surfaces as per existing finishes complete all as specified and directed.
(a) One light point controlled by one way switch 5/6 amps.
(b) One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps.
(c) One Socket out let 5/6 amps point on the independent board
(d) One socket out let 5/6 amps point on the same board
(e) One bell/buzzer point controlled by one bell push button
All as per item No 2.00 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed.
S&F in repair switch piano flush type 5/6 amps single pole one way complete all as specified and directed.
S&F in repair socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed.
S&F in repair of socket outlet 2 in 1, 5 Pin, 5/15 amp, multipurpose 230 volt flash type complete all as specified and directed by Engr-in-Charge.
S&F in repair switch piano flush type 15/16 amps single pole one way complete all as specified and directed.
S&F in repair bell/buzzer push 5/6 amps flush type white/ivory finish complete all as specified and directed.
S&F in repair of call bell ding dong type AC Single pole 220/240 Volts, surface type complete all as specified and directed.
S&F in repair ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S & F in repair lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed Make : Havells Reo.
S & F in repair deluxe fan electronic regulator 120/180 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and directed.
S&F in repair surface & wall mounted 20 watt LED batten light fittings with extruded Aluminium housing complete with constant current electronc driver all accessories including provision of three core PVC cable of copper conductor and making connection complete all as specified and directed.
S&F (in replacement) LED street light fitting ,system wattage-30 Watt, Complies to IEC 60598 and IS 10322 with deep drawn aluminium Pressure die cast housing ,toughened glass cover with IP-66,CL-I protection,Integral electronic driver,Heat sink,Cast Aluminium pipe mounting attachment complete with LED lights and connecting the street light fitting using 2.5 Sqmm PVC insulated three core copper cable all as specified and directed.
S&F in repair Mirror Light 9/10 Watt LED with constant current electronc driver, all accessories including provision of three core PVC cable of copper conductor and making connection complete all as specified and directed.
S&F in repair Decorative luminiare suitable for wall light fixture of LED lamp 15 watt ( B-22 base) ,made of unbrakeable Polycarbonate with Acrylic decorative diffuser, IP-65 protection, and provision of PVC insulated sheathed round flexible wire with multi stranded copper conductor of size 2.50 Sq mm two core complete all as specified and directed.
S&F in repair 10 watt LED Bulkhead light fittings complete with aluminium Alloy grey powder coated housing, Heat resistant prismatic Glass cover with EPDM rubber linning,constant current electronc driver all accessories including provision of three core PVC cable of copper conductor of size 23/.0076 and making connection complete all as specified and directed.
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete including taking down the old one complete all as specified and directed by Engr-in-Charge.
S&F in repair Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Tripple pole & neutral with 200 amps rated bus bar, IP-20 protection, complete all as specified and directed.
S&F MCB (Isolator), Triple pole & neutral, 40 amps, 415 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed.
S&F MCB (Isolator), Triple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed .
S&F MCB, Single pole & neutral 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge.
S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCCB 100 amps 4 pole adjustable thermal & fixed magmetic setting four pole 415 volt 50 Hz with breaking capacity 10 KA including taking down the old one complete all as specified and directed by Engr-in-Charge.
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed .
M & L Sub main wiring concealed type with two run single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size, making good the disturbed surfaces complete. (NOTE : Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length. .
M & L Sub main wiring casing caping type with two run single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 6.0 Sqmm connected to common earth dolly and drawing into rigid PVC casing caping of size 32 mm medium grade size, making good the disturbed surfaces complete. (NOTE : Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length. .
M&L for street light bracket made out of GI pipe light grade 25 mm dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.2 mtr length by cutting, welding and well finishing including MS clamp of flat iron of size 25 x 5 mm suitable length 2 Nos complete with drilling hole, fixing with runts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 2 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A').
All as per ser item No 34 above but of cross sectional area 16 sqmm 4 core
All as per ser item No 34 above but of cross sectional area 25 sqmm 4 core
All as per ser item No 34 above but of cross sectional area 35 sqmm 3.5 core
All as per ser item No 34 above but of cross sectional area 50 sqmm 3.5 core
All as per ser item No 34 above but of cross sectional area 95 sqmm 3.5 core
All as per ser item No 34 above but of cross sectional area 120 sqmm 3.5 core
Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out for electric cable complete in any type of soil complete all as specified and directed
Returning, filling in, soil obtained from excavation including spreading, levelling and well ramming in layers n.exc 25cm thick complete all as specified and directed
Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point complete all as specified and directed
M & L for sand cushioning with river Sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable punned to a thickness of 18 cm) complete all as specified and directed
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed
Laying only old sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed
M&L (in replacement) for GI tubing 40 mm bore ,light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as specified and directed.
Supply and fix Timer switch 24 hrs, anolog type , for automatic building lights ON / OFF control complete all as specified and directed.
Disconnecting of electric connection from ceiling rose and taking down the ceiling fan any type sweep for carrying out replacement/cleaning greasing, oiling, tight fit the fan blades/ hooks on roof/ fan clamps/ down rod as required for the user with fan hook etc and refixing the same in position after completed the all works incl fixing/ labour only for replacement of unsv parts , greasing, oiling, reset of fan blades etc and replacement/repairs of minor rubber parts, connectors,bolts, nuts etc incl replaccement/reapairs of unsv flexible connection wire etc upto 1 metre length complete all as specified and directed. Note : Rates quoted by the contractor shall deemed to be included for replacement of ceiling fan parts.
Taking out Sheet metal enclosure of 12/8/6/4/2 way Distribution Boards from its original position and refixing after the B/R work /or any directions by engr-in-charge at the same place complete all as specified and as directed.
Geyser Taking down the existing unsv storage type electric water heater (geyser)of any make/ capacity, installed at different location including dis-connecting, taking down opening all parts/accessories for inspection, cleaning, descaling, refixing serviceable parts, replacing unserviceable parts installed at old location and reconnection, testing complete all as directed by Engineer-in-Charge for the follwoing capacity :-
(a) 25 Ltr capacity
(a) 35 Ltr capacity
(a) 50 Ltr capacity
Note :-The rates quoted above deemed to have been included fixing charges of new parts to be given as supply only here in below. Removing unseviceable materials out of site and depositing serviceable materials to MES store.
Supply only heating element round type of geysers including rubber washer for the 1500 Watt capacity mplete all as specified and as directed.
Supply only heating element round type of geysers including rubber washer for the 2000 Watt capacity mplete all as specified and as directed.
Supply only PVC connection pipe with brass unions at both ends, 450mm long 15mm bore (for incoming cold water) all as specified and as directed.
Supply only chromium plated copper connection pipe 450mm long with two brass adopters washers and connecting up complete all as specified and directed.
Supply only apparatus plate suitable for 25 ltrs capacity geyser complete all as specified and as directed.
Supply only apparatus plate suitable for 35 ltrs capacity geyser complete all as specified and as directed.
Supply only apparatus plate suitable for 50 ltrs capacity geyser complete all as specified and as directed.
Supply only thermostat (ISI Marked) for 25/35/50 Liters capacity Geyser complete all as specified and as directed.
Supply only thermostat (ISI Marked) for 25/50 Liters capacity Geyser for Racold geysers complete all as specified and as directed.
Supply only steel tanks 25 liters and refixing after testing the leakage complete incl replacement of insulating material (Glass wool) for 25 Liters capacity Geysers and replacement of rubber packaging ring heat resistsnt type all as directed.
Supply only steel tanks 35 liters and refixing after testing the leakage complete incl replacement of insulating material (Glass wool) for 35 Liters capacity Geysers and replacement of rubber packaging ring heat resistsnt type all as directed .
Supply only steel tanks 50 liters and refixing after testing the leakage complete incl replacement of insulating material (Glass wool) for 50 Liters capacity Geysers and replacement of rubber packaging ring heat resistsnt type complete all as specified and as directed.
S&F in replacement safety nut for pressure release valve (As per sample) complete all as specified.
S&F in replacement hole fastener 10 mm dia, 100 mm long including nut and washer complete all as specified.
S&F non return valve complete all as specified and directed
S&F in replacement rubber gas Kit suitable for 50/25 ltrs capacity geyser (as per sample) complete all as specified.
M&L for fixing of new/old geysers at new place with hole fastener and cement work including connection with existing pipes complete all as specified and as directed.
Ceiling and Exhust fans Disconnecting of electric connection from ceiling rose and taking down the ceiling/exhaust fan any type sweep for carrying out repairs / rewinding/ replacement/cleaning etc and refixing the same in position after repairs incl fixing/ labour only for replacement of unsv parts , greasing, oiling etc and replacement of minor rubber parts, connectors,bolts, nuts etc incl replacent of unsv flexible connection wire etc upto 1 metre length complete all as specified. Note :-The rates quoted above deemed to have been included fixing charges of new parts to be given as supply only here in below. Removing unseviceable materials out of site and depositing serviceable materials to MES store.
M & L for rewinding of coils of ceiling fan of any make and sweep by following ways .(i) Taking out complete coils from the rotor of ceiling fan (ii) Rewinding of ceiling fans of any sweep by using super enamelled copper wire and turns as per existing gauge and approved quality including insulation paper ,varnishing, drying and refitting the ceiling fan and testing the speed complete all as directed as per Engr in charge
M & L for rewinding of coils of exhaust fan of any make and sweep by following ways .(i) Taking out complete coils from the rotor of ceiling fan (ii) Rewinding of ceiling fans of any sweep by using super enamelled copper wire and turns as per existing gauge and approved quality including insulation paper ,varnishing, drying and refitting the ceiling fan and testing the speed complete all as directed as per Engr in charge
Supply only parts/components of ceiling fan as per existing make and size complete all as specified and as directed.
(a) Gun metal bush bearing
(b) Ball bearing
(c) Capacitor 2.5 MFD
(d) Capacitor 3.0 MFD
(e) Connector bakelite two terminals each end complete all as specified.
(f) Rubber bush with MS Bolt and Nut complete all as specified.
(g) PVC canopy for ceiling fan
(h) Capacitor 4 MFD
Digging out incoming and outgoing cables of any sizes from loops near junction box/ feeder pilar box in trenches, cutting burnt out uninsulated portion of cable and relaying /refixing in trenches & returning, refilling the excavated soil and connecting the cables with bus bars including provision of suitable size of aluminium lugs complete all as specified and as directed.
Relaying in trenches or passing through pipe, 1100 volts grade, LT electric power UG cables, of any type/Size with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed.
Supply and fixing of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 63 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
Supply and fixing of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 100 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
Supply and fixing of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 160 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
Supply and fixing of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 200 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
Supply and fixing of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 250 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
M&L for Heat shrinakable straight through joint for 3.5 / 4 core cable 25sqmm to 50 sqmm complete all as specified and as directed.
M&L for Heat shrinakable straight through joint for 3.5 / 4 core cable 70 sqmm to 120sqmm complete all as specified and as directed.
M & L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A'.
M&L for 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
M&L 80 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
S & F inreplacement of factory made sheet metal box made out of 2 mm thick MS sheet of size 450 X 300 X 200 mm Bus bar box 3 phase one Neutral 415 Volts with copper busbar of 25X3 mm capacity mounted on hydrograpic PVC insulator with single door hinged shutter and locking arrangement and grouting on wall incl painting with two coated of powder coated paint after necessary preparation of surface complete all as specified & directed.
S&F aluminium bus bar of size 400 mm X 40 mm X 6mm wrapped with PVC sleeves with maintaining the colour code and provision of holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends including taking out old unserviceable bus bar complete all as specified and directed.
S&F aluminium bus bar of size 600 mm X 20 mm X 6mm wrapped with PVC sleeves with maintaining the colour code and provision of holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends including taking out old unserviceable bus bar complete all as specified and directed.
S & F in replacement of factory made sheet metal box made out of 2 mm thick MS sheet of size 350(B) X 400(H) X 200(D) mm with single door hinged shutter and locking arrangement for fixing MCCB flashed / grouting on wall incl painting with two coated of powder coated paint after necessary preparation of surface complete all as specified & directed
Dismantling of old U/S LT feeder pilla box/LT junction box including foundation after disconnecting of all elecrical connection complete.
Supply ,fabrication, installation and testing of LT out door type factory made CPRI Approved , junction box of size 900mmX600mmX400mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 25X25X5mm vertical frame and legs with mild steel flat iron 25X5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed. (a) Copper bus bar of size 600 Amp wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos. (b) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, factory made (CPRI approved) water and vermin proof protection pedestal type feeder pilar box of minimum size 1200 mm x 800 mm x 500 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including provisio of cable looping box of size 900 x 450 x 400 mm . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be complete painted with Powder Coated paint of approved shade. "U" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size "F" class insulators.
The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shall be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including comprising of the following accessories : -Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement. (a) Incomming Copper busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (b) Outgoing Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos (c) MCCB 4 pole, 415 volts, 16 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 200 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos)
M&L for preparation of the old decorated existing external steel surface of feeder pillar boxes/LT panels /JBs of any size and description in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopponf required and applying two coats of Asian aspa paint by using spray painting machine on old prepared surface including marking of Sub Stn No, Feeder No and feeding area/Bldg with applying synthetic enamel paint (1st grade) complete all as specified.
Supply & fixing in repairs LED indicating RED lamp, including necessary connection complete all as specified and directed.
Supply & fixing in repairs LED indicating YELLOW lamp, including necessary connection complete all as specified and directed.
Supply & fixing in repairs LED indicating BLUE lamp, including necessary connection complete all as specified and directed.
Supply & fixing in repairs CT coil 100/5 Amps including necessary connection complete all as specified and directed.
Supply & fixing in repairs danger notice board / plate of size 20 cm x 15 cm, made out of 1.6 mm thickness mild sheet, vitreous enamelled white letters, figure and conventional skull and bones in Red colour and fixed with nuts and bolts for 1100 volts current complete all as specified and directed.
Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Permises around pole, around panel board along boundaries fencing, removing runnish material from work site and depositing where directed not exc. 100 meter from the starting point complete all as directed. Note : The item shall be operated maximum 2 (Two) times in the entire period of the Contract period and measurement will be taken every time independently for payment.
Supply and fixing aluminium strip of size 25x3.15 mm for earth continuity conductor fixed on PCC block complete all as specified as directed complete all as specified and as directed.
Supply and fixing Copper strip of size 20x3.15 mm for earth continuity conductor fixed on PCC block complete all as specified as directed complete all as specified and as directed.
Dismantling of existing unsv loose/disturbed Aluminum strip/GI Strip/Termination rod of any sizes on roof/down conductor fixed on wooden guities /directly on roof including screws etc complete.
Supply & fixing in repairs for 32 x 6 mm galvanised iron strip,earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or fixed to poles or roof with saddel and screw current complete all as specified and directed.
Supply and fixing porcelain insulator of size 65x31 mm and height 30mm with three nos hole including GI bolts and nuts of required size and two nos washer on PCC, fixing strip complete all as specified and as directed.
Supply and fixing air termination single pointed aluminium rod 12mm dia and 300 mm dia complete all as specified and as directed.
Disconnecting electric connection and Taking down of all UG cable from LT Panel/JB of any capacity and model removing of unserviceable spares / accessories for repair/replacement of the same including reconnection of all UG Cable connection with suitable lugs ,nuts & bolts etc. to existing LT Panel/JB and testing complete all as directed. The unit Rate shall be deemed to be included for the following nature of work:(i) Contractor shall provide one Electrician and two helper along with tools. (ii) Spares/Parts for reapir will be measured and paid saperatly as supply only under relevent item of this schedule.
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I 2009 connected to pole/LT Panel all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade, for protection of earth strip complete all as specified and directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate.
M/S P K AGARWALA
SHRI D P AGARWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .