| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.4 LAccepted-AOC CHENGALA AYSHA MANZIL BERKA CHERKALA PIN 671541 | KASARAGOD | KERALA | 671541 | ₹77.4 L | L1 | Accepted-AOC L1 bidder |
| Sl No | Description | Qty | Unit | MUBEEN M A L1 |
|---|---|---|---|---|
| 1.00Ground development Works-Mud Multi purpose court | ||||
| 1.01 | 2.28.1Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil | 3,770.69 | sqm | 38.82 ₹1.5 L |
| 1.02 | OD105506/2025-2026Filling with contractor's own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering and rolling every 3rd and top most layer with power roller of minimum 8 tonnes, for all leads including all lifts involved as per the direction of site Engineer- in-charge. (MR rate based on the Order No. CE/R&B/ALP/769/2016 dated 22.05.2017, Based on DSR Item No. 50.2.26.1 and 2.2.1) | 377.07 | cum | 932.91 ₹3.5 L |
| 1.03 | OD164923/2025-2026Supplying and stacking sieved red earth at site for measurement including royalty and carriage upto 5 k.m. lead, all labour charges for stacking, loading, unloading, etc. complete. (Based on CPWD 30.2.2 & 30.2.4.3) | 603.31 | cum | 1,511.81 ₹9.1 L |
| 1.04 | OD170120/2025-2026Supplying and stacking sieved Sand at site for measurement including cost of sand, carriage upto 5 km lead, all labour charges for stacking, loading, unloading etc complete. (Based on CPWD 30.2.2 & 30.2.4.3) | 150.83 | cum | 3,324.34 ₹5.0 L |
| 1.05 | OD170119/2025-2026Mixing Departmentally supplied seived red earth and seived sand in the required proportion specified or directed by the officer-in-charge including all cost of labour charges, hire charges of machineries etc complete. (Based on CPWD 30.2.9) | 754.14 | cum | 59.52 ₹44,887.05 |
| 1.06 | OD170118/2025-2026 Spreading of mixed Departmentally supplied seived red earth and seived sand in the required thickness as per direction of officer-in-charge including all cost of labour charges, hire charges of machineries etc compete. (Based on CPWD 30.2.8) | 754.14 | cum | 85.36 ₹64,373.22 |
| 1.07 | OD105503/2025-2026Consolidation of sub grade with power road roller of 8 to 12 tonne capacity with road roller including making good the undulations etc. including all cost of labour, hire charges, fuel, oil, etc. complete.( Based on CPWD 16.1) | 3,770.69 | per sqm | 3.89 ₹14,683.07 |
| 1.08 | OD105504/2025-2026Supply and installation of fixed type 7's Football Goal Post( 3.65 m x 1.8 m x
1.2 m) made of pipe 10 cm
dia GI pipe with nylon net as per direction of Engineer in charge | 1 | pair | 27,500 ₹27,500 |
| 1.09 | OD170751/2025-2026Supply of Fixed 3.5 inch Volleyball post set with net including all necessary fitting, labor, transportation charges etc complete | 1 | set | 25,472.18 ₹25,472.18 |
Tender Value
₹76.1 L
EMD Value
₹50,000
Closing Date
24 Feb 2026, 3:00 pmClosed
The Chief Engineer, Sports Kerala Foundation
Jimmy George Indoor Stadium, Vellayambalam, Thiruvananthapuram
Ground development Works-Mud Multi purpose court, DR Retaining Wall, Fencing and Inauguration Stone, RR Step Gallery and Electrification Work
2025_SKF_820330_3
353/SKF/CE/2025-26
Open Tender
Civil Works - Others
180 days
Alappuzha
Please refer tender document
7 documents required · 7 mandatory
₹2,950
₹50,000
21 Mar 2026
16 Feb 2026
26 Feb 2026
16 Feb 2026
24 Feb 2026
16 Feb 2026
Ground development Works-Mud Multi purpose court
2.28.1Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil
OD105506/2025-2026Filling with contractor's own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering and rolling every 3rd and top most layer with power roller of minimum 8 tonnes, for all leads including all lifts involved as per the direction of site Engineer- in-charge. (MR rate based on the Order No. CE/R&B/ALP/769/2016 dated 22.05.2017, Based on DSR Item No. 50.2.26.1 and 2.2.1)
OD164923/2025-2026Supplying and stacking sieved red earth at site for measurement including royalty and carriage upto 5 k.m. lead, all labour charges for stacking, loading, unloading, etc. complete. (Based on CPWD 30.2.2 & 30.2.4.3)
OD170120/2025-2026Supplying and stacking sieved Sand at site for measurement including cost of sand, carriage upto 5 km lead, all labour charges for stacking, loading, unloading etc complete. (Based on CPWD 30.2.2 & 30.2.4.3)
OD170119/2025-2026Mixing Departmentally supplied seived red earth and seived sand in the required proportion specified or directed by the officer-in-charge including all cost of labour charges, hire charges of machineries etc complete. (Based on CPWD 30.2.9)
OD170118/2025-2026 Spreading of mixed Departmentally supplied seived red earth and seived sand in the required thickness as per direction of officer-in-charge including all cost of labour charges, hire charges of machineries etc compete. (Based on CPWD 30.2.8)
OD105503/2025-2026Consolidation of sub grade with power road roller of 8 to 12 tonne capacity with road roller including making good the undulations etc. including all cost of labour, hire charges, fuel, oil, etc. complete.( Based on CPWD 16.1)
OD105504/2025-2026Supply and installation of fixed type 7's Football Goal Post( 3.65 m x 1.8 m x 1.2 m) made of pipe 10 cm dia GI pipe with nylon net as per direction of Engineer in charge
OD170751/2025-2026Supply of Fixed 3.5 inch Volleyball post set with net including all necessary fitting, labor, transportation charges etc complete
OD170752/2025-2026Supply and installation of heavy-duty badminton post in aluminum and steel uprights option with built in weights and floor protection pads. Base, uprights and back supports can be detached. Rate also includes wheels for easy movement, steel uprights (comes in a pair), badminton net etc. Approval shall be taken prior to supply of item.
DR Retaining Wall
2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
60.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
5.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.2.1Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Fencing and Inauguration Stone
2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm
5.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
4.1.3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
4.3.1Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
OD105508/2025-2026Steel work for fencing with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete(Rate based on CPWD 50.10.2)
16.70.1Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm
OD105510/2025-2026Supply and Installation of approved quality 2mm thick UV Stabilized Nylon net of Mesh size not greater than 50mm in existing GI poles including all charges as per the
10.25.2Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.71Lettering with black Japan pint of approved brand and manufacture
OD105509/2025-2026Providing and fixing 18 mm thick gang saw cut, mirror polished, pre-moulded and prepolished, machine cut for inauguration granite stone of required size, approved shade, colour and texturelaid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) joint treated with white cement,mixed with matching pigment, epoxy touchups including rubbing, curing etc. complete at all levels. Area ofslab over 0.50 sqm (Based on Item 8.2.2.2 of DSR)
16.21Engraving letters in hard stone
RR Step Gallery
2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
60.7.1DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
7.1.1Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.1Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.7.2 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
13.48.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
10.26.3 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Electrification Work
90.15.4.11Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD105495/2025-2026Supply, installation, testing, and commissioning of outdoor duty (IP 54) pedestal mounted type weatherproof, double door type KSEB metering panel, suitable for accomodating KSEB energy meter. (supply of energy meter is under KSEB scope) and consisting of 200/5A, Cl 1, 15VA cast resin CT-1 no , 3 nos. of 200A HRC Fuse base with HRC fuses and providing necessary supports made from the same gauge CRCA sheet to fix energy meters, etc . and to be fabricated out of 16 SWG MS sheet with lockable door having glass window, sealing facility for KSEB, top cover and necessary overhang, undergone seven tank process, powder-coated finish, and all mounting accessories as required complete with civil foundation. The panel shall be with all accessories as per specification
OD105499/2025-2026Supply and fixing SINTEX Box (150mmx150mmx100mm) including connector, MCB Rail and neutral links for giving connections including all accessories complete as required
OD105498/2025-2026SKF OD: Supply, installation, testing and commissioning of Outdoor Type Floor Mounting KSEB metering panel, suitable for accommodating 3 Phase Energy meter and consisting of 3 nos. of 40 A/63A cutout with HRC fuse( or as per KSEB) , neutral link in separate chamber, inter connections, provision for CT chamber, 63 A SFU-1 no and separate cabin shall be provided in outdoor panel to accommodate VDB/DB(Min. 6Way) as per the requirement etc. as required, and including necessary supports of floor or wall mounting as required, and the panel fabricated out of 14 SWG CRCA sheet with lockable door with sealing facility having glass window for energy meter, sealing facility for KSEB, top canopy and necessary overhang, undergone seven tank process ,powder coated finish and all mounting accessories as required, The firm should have CPRI Certification.
90.11.1.11Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.12.10.2Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.10.4Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size
90.12.5.40Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.5.42Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm
90.12.7.39Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
90.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.42Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured
90.6.5.12Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.12.5.39Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
90.12.5.16Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 25 sq mm
9.1.2Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.34Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
2.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
90.16.1.2Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
5.1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
OD105497/2025-2026SKF OD : Earthing with G.I. earth pipe 2.5 meter long, 40 mm dia including accessories, with providing masonry enclosure with cover plate / FRP Earth Pit Chamber. ( but without charcoal/ coke and salt ) etc as required
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1408370.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tenderdoc.pdf
Tender Documents • 1.37 MB
BOQ_1408370.xls
BOQ • 0.32 MB
DWG.pdf
Other Document • 1.11 MB
Download all tender documents and submit your bid