Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.4 L+₹1.2 L (10.7%)Rejected-Finance NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹12.5 L+₹1.3 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | Badri Electricals L1 | BK CONSTRUCTION L2 | P K SHETH L3 |
|---|---|---|---|---|---|---|
| 1.00 | Disconnecting and taking down High mast light up to 25 Mtr Height including taking down high mast assy by making necessary arrangement viz telescoping ladder alongwith all safety arrangement and re-positioning of the same after repairing all as directed, Note:- Relevent items which reqd for replacement shall be meaured and paid separately under this schedule. | 5 | Each | 1,000 ₹5,000 Lowest | 6,500 ₹32,500 | 5,000 ₹25,000 |
| 2.00 | S & F in repair MS clamp of size 50x3mm fixed with nuts & bolts of size 75x10mm dia with suitable washer of existing size for bracket on pole complete all as directed by Engr-in-Charge. | 80 | Kg | 130 ₹10,400 Lowest | 180 ₹14,400 | 130 ₹10,400 Lowest |
| 3.00 | Taking down existing street light from pole/wall of any type and refixing after repair the same all as specified and directed by Engineer-in-charge. | 139 | Each | 150 ₹20,850 Lowest | 150 ₹20,850 Lowest | 200 ₹27,800 |
| 4.00 | S & F in Repair/Replacement of LED Driver 230 Volt 50 Hz for street light fitting of 40/70/72 watt of Make Bajaj ,CG/Wipro/Philips/Havells. | 25 | Each | 800 ₹20,000 | 450 ₹11,250 Lowest | 900 ₹22,500 |
| 5.00 | S & F in Repair/Replacement of LED Driver 230 Volt 50 Hz for street light fitting of 90/100 watt of Make Bajaj /CG/Wipro/Philips/Havells. | 20 | Each | 1,200 ₹24,000 | 550 ₹11,000 Lowest | 1,300 ₹26,000 |
| 6.00 | Excavation in trenches not exceeding 1.5 meter in wide and not exceeding 1.5 meter in depth for taking out cable/ pipe line not exceeding 10 sq meter on plan and not exceeding 1.5 meter depth and getting out in soft/ loose soil complete all as specified and as directed.
Note:- (i) During the excavation damage of Road, Electric cable, Signal Cable should be rectified by the contractor without any extra cost.Surface should be matched as existing road.
(ii) Excavation shall be carried out by manual means only. | 40 | CUM | 200 ₹8,000 Lowest | 220 ₹8,800 | 275 ₹11,000 |
| 7.00 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all as specified and directed. | 23 | CUM | 72 ₹1,656 Lowest | 90 ₹2,070 | 100 ₹2,300 |
| 8.00 | Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point . | 17 | CUM | 90 ₹1,530 Lowest | 120 ₹2,040 | 100 ₹1,700 |
| 9.00 | Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by Engr –in-charge.
(Note : Measurement shall be taken after punning down.) | 26 | CUM | 800 ₹20,800 Lowest | 950 ₹24,700 | 1,000 ₹26,000 |
| 10.00 | Supply & Lay Brick common burnt clay sub class B old size confirming to IS-4885 etc complete all as specified directed by Engr-in-Charge. | 1.2 | Per 1000 Nos | 6,000 ₹7,200 Lowest | 8,500 ₹10,200 | 7,500 ₹9,000 |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
28 Aug 2025, 6:00 pmClosed
Harikesh Meena EE
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2025_MES_723956_1
8877
Open Tender
Civil Works
Item Rate
180 days
GE ARMY BARODA
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
₹26,000
Yes
29 Sept 2025
1 Aug 2025
29 Aug 2025
1 Aug 2025
28 Aug 2025
16 Aug 2025
1 Aug 2025 - 7 Aug 2025
Amount
Disconnecting and taking down High mast light up to 25 Mtr Height including taking down high mast assy by making necessary arrangement viz telescoping ladder alongwith all safety arrangement and re-positioning of the same after repairing all as directed, Note:- Relevent items which reqd for replacement shall be meaured and paid separately under this schedule.
S & F in repair MS clamp of size 50x3mm fixed with nuts & bolts of size 75x10mm dia with suitable washer of existing size for bracket on pole complete all as directed by Engr-in-Charge.
Taking down existing street light from pole/wall of any type and refixing after repair the same all as specified and directed by Engineer-in-charge.
S & F in Repair/Replacement of LED Driver 230 Volt 50 Hz for street light fitting of 40/70/72 watt of Make Bajaj ,CG/Wipro/Philips/Havells.
S & F in Repair/Replacement of LED Driver 230 Volt 50 Hz for street light fitting of 90/100 watt of Make Bajaj /CG/Wipro/Philips/Havells.
Excavation in trenches not exceeding 1.5 meter in wide and not exceeding 1.5 meter in depth for taking out cable/ pipe line not exceeding 10 sq meter on plan and not exceeding 1.5 meter depth and getting out in soft/ loose soil complete all as specified and as directed. Note:- (i) During the excavation damage of Road, Electric cable, Signal Cable should be rectified by the contractor without any extra cost.Surface should be matched as existing road. (ii) Excavation shall be carried out by manual means only.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point .
Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by Engr –in-charge. (Note : Measurement shall be taken after punning down.)
Supply & Lay Brick common burnt clay sub class B old size confirming to IS-4885 etc complete all as specified directed by Engr-in-Charge.
Taking out existing LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor from tranches/ducts/pipe, on wall, poles of following size and removing unserviceable cable from site to store of size 16 sq mm 4 core.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core Make Polycab/Havells/Gloster or as specified in PS.
M&L for GI tubing light grade fixed on wall/pole laid in trenches/under road of the following sizes 50 mm dia complete all as specified and directed by Engr-in-Charge.
Taking out cable loop after dismantling cable ends from panels, cutting/removing heated cable ends with burnt lugs and inserting new lugs after cutting opening of fresh cable end complete including earth work and relaying cable neatly around loop for cable size 50 to 120 Sqmm.
Supply, laying & testing PVC insulated, PVC sheathed cable electric control cables (Heavy duty) with multy stranded copper conductor of size 1.5 sq mm ,3 core, 1100 Volts grade. Make Polycab/Havells/Gloster or as specified in PS. (Note : Necessary clamps & flexible if reqd shalll should be included in above quoted rate)
Supply and Fix in replacement of 40 watt LED post top lamp New generation IP 65, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source including electric connection with suitable size of cable.Make : CORALGENXPT40WLED757PSYMTOPC of Havells or equivalant to Philips,Bajaj ,Crompton,Wipro,etc.or as specified in PS. Note :- The warranty on light should be minnimum of 2 Years .
Supply & Fix in replacement of 90 Watt LED Street Light fitting New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device ,lumens should be ≥ 120 lm/w ,OEM driver,PF 0.9,CCT 6500K including electric connection with suitable size of cable. Make:ENDURASUNBEAMSL90WLED757SASYTOPCSENSO of Havells or equivalent in Philips,Bajaj or as specified in PS Note :- The warranty on light should be of minnimum 2 Years .
Supply & Fix in replacement of 70 Watt LED Street Light fitting New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device ,lumens should be ≥ 120 lm/w ,OEM driver,PF 0.9,CCT 6500 including electric connection with suitable size of cable. Make: ENDURASUNBEAMSL70WLED757SASYTOPCSENSO of Havells or equivalent in Philips,Bajaj or as specified in PS. Note :- The warranty on light should be of minnimum 2 Years .
M & L for preparation of existing old painted surface of any description such as LT/HT steel tubular electric pole/struts of any height and painted completed including cross arms bracing clamps etc with one coats of aluminium paint and in white/blue alternative strips of 30 cm width each all around the poles up to 1.5 M height form the ground level/top of PCC copping including writing MES, LT/HT feeder No. and Pole No. (in capital letters) stencil cut decorative manner on pole using fluorescent paint as directed.
S & F in replacement LED High Mast Flood Light fitting , 250 W Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium non integral IP66 protectionand impact resistance of IK07 with 10KV Built-in-Surge Protection device, ,lumens should be ≥ 120 lm/w ,OEM driver,PF 0.9,CCT 5700K ,flood light, suitable for high mast application, highlighting architectural facade and general purpose lighting including electric connecton with suitable size of cable. Make-Make-JETAADORNFLS 250W LED 757S SYMTOTGV2 of Havells or equivalent in Phillips/Wipro or as specified in PS. Note :- The warranty on light should be of minnimum 2 Years .
S & F in replacement MCCB three pole of capacity 63 to 100 Amps, 16KA 415 volt thermally and magnetic Adjustable suitable to be houses in existing space including link seperator. Make Havells/Legrand/L&T/Schneider or as specified in PS.
S&F in replacement MCB SP 6 to 32 Amps 240V, 10 KA 'B' curve Complete with connection testing and commissioning. Make Legrand/C&S/Havells or as specified in PS.
S & F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT of size 20x15cm complete all as directed by Engr-in-Charge.
Material and labour PCC (1:2:4) type B-2, using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by Engr - in -charge.
S&F in replacement 40 mm bore GI pipe medium grade fixed as bracket for street light on LT poles/walls, suitable for street light fittings, not less than 1.20m long and bent to shape as required including necessary clamps , nut and bolts complete all as specified and directed by Engr-in-charge.
BK CONSTRUCTION (BID ID -3408630)
P K SHETH (BID ID -3398803)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .