Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | WEST BENGAL | 711113 | ₹8.9 L | L1 | Accepted-AOC AOC |
| 2 | L2₹9.6 LRejected-Finance 103 1A RAJA DINENDRA STREET KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | ₹9.6 L | L2 | Rejected-Finance L2 |
| 3 | L3₹10.2 LRejected-Finance | ₹10.2 L | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹20,718
Closing Date
19 Jan 2026, 11:00 amClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
Urgent Electrical Works for renovation by upgradation of two rooms i.e. Vidyasagar Sava Ghar at 4th Floor and another room at 3rd Floor in APC Bhawan, Salt lake, Kol-91---SITC of AC Work
2025_WBPWD_979909_1
WBPWD/EE/BED/e-NIQ-89/2025-26 2nd call
Open Tender
ELECTRICAL WORKS ORG
30 days
APC Bhawan
Please refer Tender documents.
5 documents required · 5 mandatory
₹20,718
13 Feb 2026
26 Dec 2025
21 Jan 2026
5 Jan 2026
19 Jan 2026
5 Jan 2026
Supply and delivery of Cassette Air Conditioner fitted with Rotary / Scroll Compressor: Cooling capacity nominal (K.Cal/Hr): 12000; Cooling Cap(Min) Guaranteed (K.Cal/Hr):10500 ; Min Room Discharge Air Flow (Cu.m/h): 1600. (4 TR) Make: Mitsubishi Heavy / O.General / Daikin as per EIC.
Supply and delivery of Cassette Air Conditioner fitted with Rotary Compressor: Cooling capacity nominal (K.Cal/Hr): 5800; Cooling Cap(Min) Guaranteed (K.Cal/Hr): 5500; Min Room Discharge Air Flow (Cu.m/h): 800; R410a / R-32 Gas Without Installation Kit of 12 fts not included. (2TR) Make: Mitsubishi Heavy / O.General / Daikin as per EIC.
Supply, Installation, Testing & Commissioning for Split Type AC Machines including making proper arrangements to grout the indoor unit with the ceiling with fass-bolts, Iron Rods & accessories.
Installation, testing and commissioning Charges for Cassette type A.C machines including making proper arrangements to grout the indoor unit with the ceiling with fass-bolts, Iron Rods & accessories. For 2TR & 4TR Cassette AC
Supply & fixing of pre-fabricated heavy duty MS angle for fixing of Cassette Outdoor unit. For 2TR & 4TR Cassette AC
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping forpackage/VRV/VRF/RAC system, complete with fittings, with adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE class -O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. 5/8" (15.88 mm) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl.19mm thick insulation.
3/8" (9 mm) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl.19mm thick insulation.
1/4" (6.4 mm) dia (Soft drawn) Cu. Pipes (As per standard 85864 or ANSIB 16.22) incl. 19 mm thick insulation.
Supply and laying of 1.1 kV grade copper unarmoured round cable of 3 core 2.5 sq. mm from IDU Unit to ODU Unit for the above mentioned AC Unit.[Make:- Polycab/Havells/Gloster/Finolex/KEI/RR Kabel/As per choice of EIC]
Supply and laying of 1.1 kV grade copper unarmoured round cable of 6 core 4 sq. mm from IDU Unit to ODU Unit for the above mentioned AC Unit.[Make:- Polycab/Havells/Gloster/Finolex/KEI/RR Kabel/As per choice of EIC]
Supply and laying PVC Drain Pipe 25mm dia with 6 mm thick Nitrile Rubber Insulation. [Make:- Suprime/Oriplast]
Dismantling of existing old model both indoor & outdoor units for Split ton A.C machines with own tools & tackles as per direction of EIC.
FRAME WORK: Supply, fabrication and installation of MS base frame for Split type Air conditioner outdoor units.:- Supplying, fabrication & fixings MS U-channel of 6 mm thick of size (75mm x 40mm x 40mm) for making Base Frame/ platform for installation of outdoor unit of above mentioned AC machines incl drilling 2 nos holes in each channel, cutting holes into the wall & grouting the same with C.C. (1:1.5:3) etc. fabricated with horizontal angle of 25mm x 25mm x 6mm and supporting angle of 50mm x 50mm x 6mm in each platform in the outer edge for transmitting the load centrally through 2 nos(50mm x 50mm x 6 mm) angle inserted into the existing wall incl. fibre sheet shade as directed by E.I.C. The entire structure must be safe to carry out maintenance of ODU. for mounting of AC machine outdoor Unit with platform arrangement for proper maintenance at 3rd floor in appropriate way .(4 nos X 86 kg= 344 kg)
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.47 MB
BOQ_2388875.xls
BOQ • 0.32 MB
2911_ii.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid