Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC 1128 SECTOR 22 B NEAR AROMA PETROL PUMP CHANDIGARH UT 160022 | CHANDIGARH | CHANDIGARH | 160022 | L1 | Accepted-AOC LOA | |
| 2 | L2₹41.7 L+₹6.2 L (17.6%)Rejected-Finance 11 26 BHAGWANPURA KISHANGARH CHANDIGARH | L2 | Rejected-Finance Highest | |
| 3 | L3₹42.5 L+₹7.0 L (19.7%)Rejected-Finance 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L3 | Rejected-Finance Highest | |
| 4 | L4₹42.7 L+₹7.2 L (20.4%)Rejected-Finance TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | L4 | Rejected-Finance Highest | |
| 5 | L5₹44.7 L+₹9.3 L (26.1%)Rejected-Finance SCO 529 3RD FLOOR KESHO RAM COMPLEX SECTOR 4 C CHANDIGARH 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | L5 | Rejected-Finance Highest |
Tender Value
₹38.0 L
EMD Value
₹76,020
Closing Date
14 Mar 2023, 5:00 pmClosed
RITESH NANDAL
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Construction of Office building for DMER Plot No. IP-1 (P) in MDC, Sec.-6, Panchkula. (Pdg. Fire Alarm System, Public Addressable System and Car Call Hailer System only).
2023_HRY_260202_1
2023D7A25283 6CAA 4AC7 A33F 195D2018E91D663BAR
Open Tender
Civil Works
Works
450 days
Ambala Cantt.
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹76,020
Yes
20 Nov 2024
24 Feb 2023
15 Mar 2023
28 Feb 2023
14 Mar 2023
28 Feb 2023
Amount
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. HSR
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of required loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. The panel should also have IP30 or better protection. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. Make: Morley ZX5SE,Bosch Avenar 2000, Siemens Cereberus. NS
SITC of Analog Addressable type Active Repeater Fire Alarm Panel with Backlit LCD display, having controlls for reset, mute, accept, silence alarms and self test conforming to BS5839 standards with all labour and materials required to complete the job in all respect up to the entire satisfaction fo engineer-in-charge of work. Make : Morley ZX R-A, Bosch FMR, Siemens FT2015 NS
SITC of addressable multisensor smoke detector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements: Drift Compensation feature and Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Morley HM/PTSE/I plus MI/B501AP/IV ,Bosch FAP-425-OT plus MS400B,Siemens OP921 plus DB11E NS
SITC of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector). Make: Morley HM/RHSE/I plus MI/B501AP/IV, Bosch FAH-425-T plus MS400B, Siemens HI921 plus DB11E NS
Supply, installation, testing and commissioning of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make : Morley HM/MCP/Glass, Bosch FMC-210- DM-G-R, Siemens XMS-S. NS
Supply, installation, testing and commissioning of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make : Morley MI/DCMO,Bosch FLM-420-RLV1-E, Siemens XTRT-R NS
Supply, installation, testing and commissioning of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make : (Morley MI DMMI, Bosch FLM-420-O1I1-E,Siemens XTRT-M NS
Supply, installation, testing and commissioning of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. Make: Morley WSO-PR-N05 plus MI/B501AP/IV,Bosch FNM-420, Siemens FDS224R NS
Supply Installation, Testing and Commissioning of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-in-Charge of work. Make Pearl/Giolite/OMEX. NS
SITC of minimum 1000 Mtr. Range Siren generatorprovided at the roof of the building with separate power suppl, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer incharge. Make: National/Kheraj NS
SITC of battery backup for controllers ( 5 KVA UPS on line with 1 hours backup ) Make Libert, Microtek, Eton. NS
SITC of PVC unsheathed copper conductor cable 1.5 sq mm single core copper 1100v grade in existing pipe excluding cost and erection of pipe but including connection etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer – in charge of work. MAKE FINOLEX / POLYCAB / Plaza. NS
SITC of EN-54 Certified IP based EVAC PA controller capable of adding 12 zones in the system and expandable upto 400 zones with 14x 4 Audio matrix with full DSP functionality. 8 audio inputs, 4 audio outputs, 4 channel output matrix. Shall support the following: single line switching or redundant group A/B switching, amplifier redundany, 4 x 100V audio inputs and 12 speaker line outputs. 8000 fault, warning and event conditions log. Built in message manager for 100 emergency/business calls up to 85 minutes. 10 control inputs and 13 control outputs. Impedance measurement and Pilot Tone supervision for speaker line monitoring. Frequency response (ref. 1 kHz) 20 Hz to 20 kHz (-0.5 dB), Signal-to-noise ratio (A-weighted): Line in to line out: 106 dB typical, THD plus N ( 0.05%, Crosstalk (line level) Line in to line out (0 dB gain): ( 100 dB at 1 kHz, Sample rate 48 kHz, DSP processing resolution 24-bit linear A/D and D/A conversion, 48-bit processing. The omneo interface unit is able to send and receive Dante audio to and from other PA Controllers with the transmission of up to 16 digital audio input signals and 16 digital audio output channels with low latency shall be possible.Ethernet connectors (Primary /Secondary)100/1000 Mbit/s, RJ-45,integrated transformer isolationSampling rate 48 kHz. Data format 24 Bit. Audio channels Up to 16 ? 16 at 48 kHz, Audio flows Up to 16 ? 16 simultaneous audio streams,Latency across network 5 ms (typically) Make /BOSCH/ Siemens/Honeywell NS
SITC of Booster amplifier 480 watts Frequency response: 60 Hz to 15 khz ( plus 1/3db), Inputs :XLR and phone jack , Input 1, Input 2-4, Impendence :20kO, Sensitivity : 1 V balanced , S/N ): )85 dB complete in all respect Make /BOSCH/ Siemens/Honeywell NS
SITC of Horn Loudspeaker 15 watts . Max power 22.5 W, Rated power (PHC) 15 W ( 15,7.5,3.75 W) ,Sound pressure Level rated power 103dB ( At 1kHz,Iw,Im), Effective frequency range (-10dB) 500Hz to 5KHz ,Opening angle (at 1 kHz/4kHz,-6 dB), Rated voltage 100V . Rated impedance 667ohm. Ambient temperature range -25 to plus 55 C .Connection 4 wire cable, 50 cm long complete in all respect Make /BOSCH/ Siemens/Honeywell NS
SITC of Cabinet and Ceiling Speaker Max Power - 9 W , Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB, Effective frequency range (-10 dB) - 200-15000 Hz, Opening angle (at 1 kHz/4 kHz, - 6 dB), In degrees - 150/70, Rated voltage - 100 V, Rated impedance - 1667 Make /BOSCH/ Siemens/Honeywell NS
Supply, installation, testing and commissioning of 22 U Standard rack to place all Av equipment Make Valrack, Comrack,Hive Networks. NS
S/I/T/C of insulated copper conductor 2 x 1.5 sqmm 1100 volts grade cables in existing surface/recessed M.S. conduit etc. as complete as required. Make Finolex/Havel/Plaza. NS
Supply and erection of ABC Dry power type fire Extinguishers of 5 kg. capacity duly hang on wall with necessary hook complete in all respect. Make: Safex/Minimax/ Ceasefire NS
Supply and erection of Co2 type fire extinguishers of 4 Kg capacity duly hang on wall with necessary hook complete in all respect. Make: Safex/Minimax/ Ceasefire NS
AVNET Solutions
Insat Techno Services
Prime Computers
Hytek Communications and Networking
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .