Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.9 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹80.3 L+₹26.8 L (50.2%)Rejected-Finance 11 7 PARMAL COLONY LAKKARPUR RAILWAY CROSSING LAKKARPUR FARIDABAD FARIDABAD HARYANA 121003 UDYAM DL 09 0001967 06AABCI9677H1Z6 R M MSME STATUS AS VERIFIED | FARIDABAD | HARYANA | 121003 | L2 | Rejected-Finance Not L1 Bidder | |
| 3 | L3₹82.1 L+₹28.6 L (53.6%)Rejected-Finance | L3 | Rejected-Finance Not L1 Bidder | |
| 4 | L4₹84.2 L+₹30.7 L (57.4%)Rejected-Finance | L4 | Rejected-Finance Not L1 Bidder | |
| 5 | L5₹99.1 L+₹45.6 L (85.3%)Rejected-Finance 2 KALKAJI INDUSTRIAL AREA KALKAJI KALKAJI SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | L5 | Rejected-Finance Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
17 Jul 2019, 1:00 pmClosed
XEN/MP, DCRTPP, HPGCL, Yamunanagar
XEN/MP, DCRTPP, HPGCL, Yamunanagar
For Insulation and Cladding work in Unit-II (TG-II and BMD-II areas and their auxiliaries areas) of 2x300MW, DCRTPP, HPGCL, Yamuna Nagar during forthcoming capital overhauling of the Unit in 2019-20.
2019_HBC_82900_1
03/MP/Unit-II/INS/168 Dated 26/06/2019
Open Tender
Miscellaneous
Works
60 days
DCRTPP, HPGCL
As per NIT
2 documents required · 2 mandatory
₹1,180
Yes
Sr. AO, DCRTPP, HPGCL, Yamunanagar
₹1.3 L
Yes
9 Jul 2020
26 Jun 2019
17 Jul 2019
26 Jun 2019
17 Jul 2019
26 Jun 2019
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 250mm
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 200mm
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 120mm
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 100mm
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 200mm
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 180mm
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 150mm
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 50mm
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 90mm
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 90mm
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 180mm
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 120mm
Applying Insulation and Cladding, Material /Type of Insulation: Al. Silicate + Rock wool mattress, Thickness of Insulation : 50mm + 120 mm
Applying Insulation and Cladding, Material /Type of Insulation: Rock wool mattress, Thickness of Insulation : 200mm
Applying Cladding only
Applying Cladding only
Repair/Refixing of existing Corrugated/Aluminium sheet
Applying Insulation only Material /Type of Insulation: Rock wool mattress Thickness of Insulation : 250mm
Applying Insulation only Material /Type of Insulation: Rock wool mattress Thickness of Insulation : 200mm
Applying Insulation only Material /Type of Insulation: Rock wool mattress Thickness of Insulation : 150mm
Applying Insulation only Material /Type of Insulation: Rock wool mattress Thickness of Insulation : 120mm
Applying Insulation only Material /Type of Insulation: Rock wool mattress Thickness of Insulation : 100mm
Aluminium Silicate Fibre Block Type Insulation & Plaster (Cover Cylinder) Zone (Pipe length)-1424mm, Zone temp-343 deg Celsius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : 60X3 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster (Cover Cylinder) Zone (Pipe length)-2615mm, Zone temp-482 deg Celsius Celsius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : 60X3 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster (Cover Cylinder) Zone (Pipe length)-1350mm, Zone temp-388 deg Celsius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : 60X3 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster (Base Cylinder) Zone (Pipe length)-1424mm, Zone temp-343 deg Celsius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : 70X3 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster (Base Cylinder) Zone (Pipe length)-2615mm, Zone temp-482 deg Celsius Celsius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : 70X3) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster (Base Cylinder) Zone (Pipe length)-1350mm, Zone temp-388 deg Celsius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : 70X3 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster (Steam Inlet Sleve Cover Cylinder), Zone temp-537 deg Celsius on HIP Turbine & other associated valves and pipelines with turbine . (Thickness of Insulation : 80X2 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster (Steam Inlet Sleve Base Cylinder), Zone temp-537 deg Celsius on HIP Turbine & other associated valves and pipelines with turbine . (Thickness of Insulation : 80X2 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster (Dum ring balance piping, Cover Cyclinder), Zone Length-25400, Zone temp-454 deg Celsius on HIP Turbine & other associated valves and pipelines with turbine . (Thickness of Insulation : 40X2 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster (Dum ring balance piping, Base Cyclinder), Zone Length-25400, Zone temp-454 deg Celsius on HIP Turbine & other associated valves and pipelines with turbine . (Thickness of Insulation : 40X2 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster GV Piping, Cover Cylinder, Zone Length-ø194x50, Zone Temp-537 deg celcius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : ø219x70 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster GV Piping, Base Cylinder, Zone Length-ø194x50, Zone Temp-537 deg celcius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : ø356x50 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster IV & RSV Piping, Cover Cylinder, Zone Length-ø508, Zone Temp-537 deg celcius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : ø508x60 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster IV & RSV Piping, Base Cylinder, Zone Length-ø508, Zone Temp-537 deg celcius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : ø630x80 mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster Cross Over Pipe, Zone Length ø1275x11, Zone Temp-350 degree Celsius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : Inner Layer- 50mm, Outer Layer-40mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster TV & GV valves, Zone Temp-537 degree Celsius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : Inner Layer- 80mm, Outer Layer-80mm) (Detail Drg Enclosed in scope of work)
Aluminium Silicate Fibre Block Type Insulation & Plaster IV & RSV Valves, Zone Temp-537 deg celcius on HIP Turbine & other associated valves and pipelines with turbine . . (Thickness of Insulation : Inner Layer- 80mm, Outer Layer-70mm) (Detail Drg Enclosed in scope of work)
Suny Insulations (India)
Shree Engineers
INDO STAR INSULATION PRIVATE LIMITED
Ms Om Insulation
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .