Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹40.0 L+₹1.9 L (5.06%)Rejected-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹41.0 L+₹2.8 L (7.47%)Rejected-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹42.4 L+₹4.3 L (11.3%)Rejected-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-AOC REJECTED | |
| 5 | Rejected-Technical | - | Rejected-Technical REF TECHNICAL EVALUATION DOCUMENTSr |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
1 Oct 2022, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
REPAIR MAINT/REPLACEMENT OF INTERNAL AND EXTERNAL ELECTRIC SUPPLY WATER SUPPLY DG SETS AND OTHER MISC ITEMS AT ICGRA DHARAMPUR AND ICGAE PORBANDAR UNDER GE I CG PORBANDAR
2022_MES_551219_1
8768
Open Tender
Civil Works
Item Rate
Porbandar
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE I CG PORBANDAR
₹77,000
Yes
25 Oct 2022
10 Sept 2022
3 Oct 2022
10 Sept 2022
1 Oct 2022
26 Sept 2022
Amount
SCHEDULE 'A'
Material and labour for painting of the tranformer 250 KVA to 630 KVA, RMU, VCB and CSS Body complete by removing old paint by scrapping and providing spray painting with epoxy paint of approved (suitable for existing colour) make duly marking/writing MES/SM No. all as directed by Engr-in-Charge.
Taking out UNSV HT UG cables of any sizes from trenches all as spd.
Supply, Laying, connecting, testing and commissioning and jointing,HT under ground cable of size 120 sqmm 3 core, 11000 volts grade, XLPE insulated screened PVC bedded, armoured with galvanised round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminium conductor, laid in renches, ducts, fixed on poles/walls with proper size saddles and clamp laid under roads/ path/drain/ culverts or encased in GI pipe fixed & testing and commissioning complete all as specified and as directed. Make : Polycab/Havells/ RR Kabel
Supply, Laying, connecting, testing and commissioning and jointing,HT under ground cable of size 185 sqmm 3 core, 11000 volts grade, XLPE insulated screened PVC bedded, armoured with galvanised round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminium conductor, laid in renches, ducts, fixed on poles/walls with proper size saddles and clamp laid under roads/ path/drain/ culverts or encased in GI pipe fixed & testing and commissioning complete all as specified and as directed. Make: Polycab/Havells/ RR Kabel
Supply & fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed. Make-Denson/Raychem/3M
Supply & fix Cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 Sqmm complete all as specified and directed. Make-Denson/Raychem/3M
Supply & fix Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 Sqmm complete all as specified and directed. Make-Denson/Raychem/3M
M&L for Dehydration/Filteration of tranformer oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS-355. Break down voltage should not be less than 50 KV complete all as specified and as directed by Engr-in-Charge.
M&L Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement all as specified and as directed by Engr-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand) Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
Supply and Fixing in replacement air break switch triple pole, 11KV, mechanically operated mounted on insulators and steel frame, with operating mechanism worked from ground level, for current rating up to 200 amps complete with including insulators horizontal /vertical rod and operating pipe of suitable size and length including taking down the old unserviceble air break switch, jumper connections and reconnecting of suitable size and length and making connection to new AB switch gang operated complete all as specified and as directed by the Engineer - in - Charge. Make: Jaipuria/ Atlas/Pactil
S & F in replacement HT 11 KV drop out fuse assembly with insulator and base including fuse tube, fuse carrier top connectors incomming and out going connectors as specified and as directed by EIC. (Note: Rate include taking down existing unserviceble/ Faulty DO fuse assembly and fix the new one and make the incomming and out going connections and switch on the supply through the new DO fuse assembly all as directed by EIC) Make: Jaipuria/ Atlas/Pactil
Attending any breakdown immiediately power transformer/RMU/CSS of following capacity by OEM service engineer to check and repair /replace any spares related break down and make the power transformer serviceable with in 24 Hours complete all as specified and directed at site. Locations ICGAE/ICGRA D. Pur Note :-(i) Spares will be paid separately under relative items. (ii) Checking of all electrical connection for its proper tightness. (iii) Proper care shall be taken to isolate the supply and it shall be ensured that repairs are carried out on No LIVE switch gears. (iv) Each switch gear/Load break switch/breaker shall be counted as a separate unit for the purpose of measurement.
250 to 630 KVA
RMU/CSS
M & L for Maintenance/Over hauling of RMU (1 No incoming, 2 No’s outgoing) of outdoor type no extensible 11 KV, SF6 insulated compact ring main unit (RMU) with short circuit peak making current 50 KA and short circuit breaking current 20 KA fully arc proof metal enclosed free standing floor mounting manually operated fixed type SF6 insulated, 2 Nos. Load break switches 400 Amps (as incoming) and 1 No SF6 circuit breaker 200 Amps (as outgoing), by using air blower, tightening the control circuit, Checking the all fuses, to ensure the smooth functioning of HT RMU by employing the Skilled trades man and helper all as directed by Engineer -In - Charge. Note: Rate Include following:- (i) Replacement of Mechanical indication in the front in the mimic for open & close breaker/isolator/ earth switch and Manual push button for emergency trip. etc., all as specified and as directed.. (ii) Disconnect the Ht cables in Test position, Check the megger value of RMU terminals with body by suitable HT megger of range 5000 Volt and check the serviceability of earthing connection by Earth megger note down the readings.
M & L for Maintenance/Over hauling of Compact Substation outdoor type (CSS), 630 kVA Transformer, 11kV Ring Main Unit consisting of 2 Nos (01 No In Cmg & 02 Nos Out Going) & 630A at 11kV fault making load breaking switch with one no SF6 insulated Vacuum Circuit Breaker & with LT Panel comprising of 1000 Amp ACB as secondary side, by using air blower, tightening the control circuit, Checking the all fuses, to ensure the smooth functioning of HT RMU by employing the Skilled trades man and helper all as directed by Engineer -In - Charge. Note: Rate Include following . (i) Replacement of Mechanical indication in the front in the mimic for open & close breaker/isolator/ earth switch and Manual push button for emergency trip. etc., all as specified and as directed. (ii) Replacement of Digital volt meter, Amp Meter , Power factor meter and CT of Ratio 1000/5 for RYB Phase in LT Panel
M & L for Maintenance/Over hauling of HT VCB 11 KV (1 No incoming, 3 Nos outgoing) by taking shunt down with prior intimation and cleaning of HT VCB by using air blower, tightning the control circuit, Checking the all fuses, to ensure the smooth functioning of HT VCB by employing the Skilled trades man and helper all as directed by Engineer -In - Charge. Note: Rate Include following (i) Replacement of small piece of wire of sq area up to 1.5 sqmm Control Ckt cable) of Max length 5 Mtrs and replacement of unseviceble indicator lamps asper colour code allas specified and as directed. (ii) Rack out /Down the HT VCB kept in Test position , Check the megger value of VCB terminals with body by suitable HT megger of range 5000 Volt and check the servicebility of earthing connection by Earth megger note down the readings.
Supply and fix in replacement of closing coil 24 Volt DC suitable for 11 KV VCB 400 Amps as per existing make and model and directed at site.
Supply and fix in replacement of vaccum bottle suitable for 11 KV VCB, 400 Amps as per existing make and model and directed at site.
Supply and Fixing in replacement of indiaction LED lights for each phase of 230 Volt complete all as specified and as directed.
Supply and Fixing in replacement of Multifunction Meters (MFM) suitable for 11 KV VCB 400 Amps as per existing make and model and directed at site.
S & F in replacement Silica Gel (Moisture absorbent chemical ) for breather of transformer 11 KV /433 Volt of any make / rating complete all as specified and as directed by engineer-in charge. Locations ICGAE/ICGRA D.Pur
S & F in replacement oil temperature indicator gauge suitble for transformer of capacity 11KV/433 Volt complete all as specified and as directed
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick , complete all as specified and directed by Engr-in-Charge.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point , complete all as specified and directed by Engr-in-Charge.
Re-Laying only un-reinforced precast concrete cable cover class HVP, type-I, flat size 300mmx l80mm x 40mm all as specified and directed. Note :- old cable cover shall be talking ont and stacked properly for re-laying.
M&L for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:2:4; including removal of surplase soil complete all as specified and directed.
Servicing of DG set ('C' Check) of Cap 50/62.5 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lub oil filter. (b) Lubrication oil. Make of DG set: Greaves, cotton, kirloskar Note: Defective parts if any other than listed at (a) to (b) above will be measured and paid separately
Supply only parts/ Items of DG set 50/62.5 KVA (Make : Greaves Cotton & Kirloskar)
Oil Filter
Fuel Filter cum water seperator
Air Filter Safety
Air Filter Primary
Coolant
Engine Oil
Fuel strainer
Materials and labour for scraping removing and cleaning old rusty paint from enclosure of DG set 50/62.5 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint as specified and directed at site by Engr-in Charge.
Comprehensive maintenance and repair of APFC panel by replacement of worn out spare parts and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories to maintain PF not less than 0.99 by adjusting/ calibrating the APFC relay of any type, complete all as specified and directed by Engr-in-Charge. Note: Defective parts if any will be measured and paid seprately.
Supply and fix in replacement of heavy duty gas filled Capacitor 5 KVAR, 440V, 3 phase, 50 Hz. all as directed by Engr-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply and fix in replacement of heavy duty gas filled Capacitor 10 KVAR, 440V, 3 phase, 50 Hz. all as directed by Engr-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply and fix in replacement of heavy duty gas filled Capacitor 15 KVAR, 440V, 3 phase, 50 Hz. all as directed by Engr-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply and fix in replacement of heavy duty gas filled Capacitor 20 KVAR, 440V, 3 phase, 50 Hz. all as directed by Engr-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply and fix in replacement of heavy duty gas filled Capacitor 25 KVAR, 440V, 3 phase, 50 Hz. all as directed by Engr-in-Charge. Make: L&T/Epcos/Schneider/C&S
Supply and fix in replacement of 6 Steps APFC Relay, microprocessor based and connected items all as directed by Engr-in-Charge. Make: L&T/Epcos/Schneider/C&S
M&L for applying two coats of epoxy paint on LT Panels of any size, including preparation of rusted surface of panel by means of sand paper/scrubing of dust etc and apply one coat of epoxy based primer before painting complete all as specified and directed, Note: Minor repair/ replacement of hinges suitable for screw fastners and fixed in original position deemed to be included in unit rate.
Supply and fix in replacement Digital time switches (SST 15 min) for street light 215 V single Phase complete all as specified. Make :L&T/Havells
M&L for preparation of old painted surfaces of Steel Tubular pole upto 9 Mtr long by scarping old paint and applying Single coat of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and Blue stripes each 30 cm (5 Strips) apart up to 1.5 Mtr height and including one coat white distempering for pole foundation above ground level shall deemed to be included in the quoted rate etc. complete all as directed by Engineer in Charge.
Dismantling and taking down the existing defective street light fitting of any type and any capacity LED street light from steel tubular pole, opening the street light fitting, checking the serviceability, remove the cable carbon and replacement of 3 Core 1.5 Sq mm size multistranded copper conductor including taking down old unsv 3 Core 1.5 Sq mm size copper conductor complete all as directed by Engr-in-Charge. Note:- 1.5 Sq mm 3 core size multistranded copper conductor etc will be measured and paid separately.
Supply & fix in Replacement street light fitting LED type 70 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and including driver unit etc and taking down old unsv any size/watt of security light including suitable electric connectio complete all as specified and directed by Engineer in charge all conforming to Cat No - LR13-781-XXX-57-XX of Wipro or equivalent from Bajaj/Philips
Supply and fix in replacement of Multi standard Copper Conductor cable of size 1.5 Sq mm 3 Core, inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box to street light fitting etc. all as specified directed. Make :- Polycab/Plaza/Havells/ RR Kabel
Material & Labour Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of following sizes-Make-Denson/Raychem/3M, complete all as specified and directed by Engr-in-Charge.
25 sqmm to 50 sq mm
70 sqmm to 120 sqmm
150 sq mm to 185 sqmm
240 sqmm to 300 sqmm
Taking out UNSV LT UG cables of any sizes from trenches all as spd.
Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area. complete all as specified and directed by Engr-in-Charge. Make: Polycab/ Havells/RR Kabel
16 Sqmm 4 Core
25 Sqmm 4 Core
35 Sqmm 3.5 Core
50 Sqmm 3.5 Core
95 Sqmm 3.5 Core
150 Sqmm 3.5 Core
185 Sqmm 3.5 Core
Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables of following sizes, complete with coupler and connected accessories all as specified and directed by Engr-in-Charge. Note: Cutting of floor/ road and making good with PCC deemed to be included in item rate. Make: Rex/Poly/Geminie
Supply and fix in replacement MCB/MCCB FP, 415 V fixed type, including taking down of old unsv panel after disconnecting Existing cables and reconnecting the cabes with proper lugs and glands complete all as specified and directed of following:- Make: Havells/ L&T / ABB /Schneider
MCCB 63/100 Amp FP, 415 V breaking capacity 27 KA
MCCB 200 Amp FP, 415 V breaking capacity 25 KA
MCCB 250 Amp FP, 415 V breaking capacity 36 KA
MCCB 320 Amp FP, 415 V breaking capacity 36 KA
MCCB 400 Amp FP, 415 V breaking capacity 36 KA
MCCB 630 Amp FP, 415 V breaking capacity 50 KA
MCB 40 Amps FP, 415 V breaking capacity 10 KA
MCB 63 Amps FP, 415 V breaking capacity 10 KA
MCB 6 TO 32 Amps SP, 240 V breaking capacity 10 KA
Comprehensive repair/ maintenance, servicing and testing of Split type air conditioners of capacity 1.5 ton/2.0 tr of any make complete by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing , oiling, greasing of blower motor, checking and removing any vibration and leakage ensure cutting of compressor / heater in case of failure of blower motor, Gas charging and testing after fixing at site, complete all as specified and directed by Engr-in-Charge. Note:(a) Cost of any minor nature repair / items such as nuts ,bolts, washers, screws, rubber mounting pads of compressor etc and labour required for removing / refixing including transportation of equipment and repair of PCB is deemed to be included in the unit rate of this items.
Supply and fix in repair u/s hermetic sealed rotary compressor with new compressor capacity not less than 19000 BTU/hr single phase, including gas charging in the system, complete all as specified and directed by Engr-in-Charge. Make : Tecumseh/Toshiba
Supply and fix in repair u/s hermetic sealed rotary compressor with new compressor capacity not less than 24000 BTU/hr single phase, including gas charging in the system, complete all as specified and directed by Engr-in-Charge Make : Tecumseh/Toshiba
M&L for rewinding of blower motor or condenser fan motor, replacement of wornout bushes, complete of split type air conditioner complete all as specified and directed by Engr-in-Charge. Note: Cutting of wornout wiring deemed to be included in unit rate
Supply and fix hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler , complete all as specified and directed by Engr-in-Charge. Make : Copeland/Tecumseh. Note : Cost of cutting of existing worn out compressor will be deemed to be included in unit rate.
Taking out burnt unserviceable condenser fan motor, rewinding electric motor, single phase 230 Volts of water cooler 40 ltrs/Hrs with super enameled copper wire of same gauge, complete all as specified and directed by Engr-in-Charge.
Supply and fix relay for water cooler of capacity 40/80 ltr/hrs, complete all as specified and directed by Engr-in-Charge. Make Renetor/ Shriram /Dunfoss.
Supply and fix Thermostat for water cooler capacity 40/80 ltr/hrs, complete all as specified and directed by Engr-in-Charge. Make:Renetor/shriram/Godraj/Danfoss
Supply and fix PVC Float valve with epoxy coated aluminium arm , with PVC polythene ball suitable for water coolers, complete all as specified and directed by Engr-in-Charge.
Taking down carefully burnt out aluminium/copper circuit wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, etc to be measured and paid for seprately) making good to the disturbed surfaces of walls ceilings and floors etc , complete all as specified and directed by Engr-in-Charge.
M&L Point wiring complete with 1.5 Sqmm single core PVC Insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volt grade down through and including non metallic rigid PVC heavy duty concealed conduit/on wall casing capping,min 20mm external dia/25mm x 16mm,, but shall be increased to suitable size, as per requirement in accordance with clause 19.125 of SSR Part I, ISI marked, including conduit accessories like bends,tees,junction box etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm earth wire, single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including Modular metal flush box of suitable size for the following:- Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make for cable : Havells/RR CABLES/Polycab/Anchor
One light/fan point controlled by one, one way switch
One bell point controlled by push button on the same board with other switch.
One 5 pin socket outlet 5/6 amps on the same board.
One 5 pin socket oulet 5/6 amps on independent board..
M&L Point wiring complete with 2.5 Sqmm single core PVC Insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volt grade down through and including non metallic rigid PVC heavy duty concealed conduit, on wall casing capping, min 20 mm external dia/ 25mm x 16mm.,, but shall be increased to suitable size, as per requirement in accordance with clause 19.125 of SSR Part I, ISI marked, including conduit accessories like bends,tees,junction box etc fixed concealed/recessed in wall or ceiling etc including 2.5 Sqmm earth wire, single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including Modular metal flush box of suitable size for the following:- (a) one 3 pin 15 or 16 Amps socket on the independent board with the required modules. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make for cable : Havells/RR CABLES/Polycab/Anchor
M&L Sub main wiring with two runs of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through and including PVC concealed/on wall conduit heavy duty / PVC casing capping, ISI marked conduit size of 25mm dia (external)/ casing capping size of 25mm x 16mm including accessories like bends, tees, junction boxes etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ Finolex/ RR Kable/ KEI
M&L Sub main wiring with two runs of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through and including PVC concealed/on wall conduit heavy duty / PVC casing capping, ISI marked conduit size of 25mm dia (external)/ casing capping size of 25mm x 16mm including accessories like bends, tees, junction boxes etc including 4 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ Finolex/ RR Kable/ KEI
S&F in replacement PVC Casing and caping size 25mmX16mm , complete all as specified and directed by Engr-in-Charge.
S&F in replacement uPVC conduit of bore 25mm, FRLS complete all as specified and directed by Engr-in-Charge.
S&F in replacement corrugated flexible pipe size 25mm complete all as specified and directed by Engr-in-Charge.
Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ , complete all as specified and directed by Engr-in-Charge. Note- worn out parts shall be measured as separately.
Supply & Fixing spare parts for Geyser
Heating element 1.5 KW with rubber gasket . Make-bajaj Model Caldia
Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked.
Hot/Cold water connection pipe 450 mm length.
Geyser assembly as per sample suitable for 25 ltr capacity Make: Bajaj Model : Cladia
Indication lamp red and green suitable for geyser as required
Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ, complete all as specified and directed by Engr-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately.
Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge..
Dismantling of Exhaust fan 250/300mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge.
S & F in repair of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed. Make Wipro - CAT PT No- LL20-111-XXX-65NE3* or equivalent to Bajaj/Philips
S & F in repair of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed. Make Wipro - LL20-221-XXX-65NE3** or equivalent to Bajaj/Philips
Supply and fix in replacement following items for maintenance of Internal Electrification , complete all as specified and directed by Engr-in-Charge.
Piano switch, flush type 5 Amps, 1 way.
Piano switch, flush type 5 Amps, 2 way.
Bell push, flush type 5 Amp.
Electric bell Ding Dong type , 230 Volts Single pole.
Socket Outlet 2 in 1, 3 pin, 6A
Switch socket combination, 6 Amps flush type.
Switch socket combination, 16 Amps flush type.
2.5 mfd Capacitor
Stepped type electronic fan regulator
S&F Modular switch 6/10 A, 1 way, 1 Module (ISI Marked) complete all as specified and directed. Make: Legrand/ Schneider/Anchor
S&F Modular switch 16 A, 1 way, 1 Module (ISI Marked) complete all as specified and directed. Make: Legrand/ Schneider/Anchor
S&F Modular socket 6/16 A, 2/3 pin combined , 2 Module (ISI Marked) complete all as specified and directed. Make: Legrand/ Schneider/Anchor
S&F Modular socket 6 A, 2/3 pin combined , 2 Module (ISI Marked) complete all as specified and directed. Make: Legrand/ Schneider/Anchor
S&F Modular Fan regulator 120W, 2 module (ISI Marked) complete all as specified and directed. Make: Legrand/ Schneider/Anchor
S&F in repair metal box 3 module including frame and plate and all as spd and directed.
S&F in repair metal box 6 module including frame and plate and all as spd and directed.
Taking up/down CI/DI pipes with connection from trenches incl connected fittings/accessories complete of 150 mm bore size and removing the pipes and reused to site complete all as spd and directed.
Taking up/down CI/DI pipes with connection from trenches incl connected fittings/accessories complete of 80/100 mm bore size and removing the pipes and reused to site complete all as spd and directed.
All as per Item Sl No.76.00 here in before but of size 100 mm bore GI pipe
All as per Item Sl No.76.00 here in before but of size 80/50 mm bore Pipe PP-R Pipe
Supply, laying and replacement of jointing in trenches DI pipes class K 9 of standard length spigot and socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating an external surface with bituminious paint of size 150 mm dia ISI complete all as specified and directed.
Supply, laying and replacement of jointing in trenches DI pipes class K7 of standard length spigot and socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating an external surface with bituminious paint of size 100 mm dia ISI all as spd and directed.
Supply, laying and replacement of jointing and testing of Class LA Cast iron pipes 80 mm dia ISI marked with standard length spigot and socket ends centrifugally cast, push type joint with run lead joint, in any length, laid in trenches complete all as specified and as directed.
Supply and lay and jointing tubing medium grade galvanised iron pipes of size 80 mm, ISI marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc and laid in trenches all as specified.
Supply and fix in replacement of size 50 mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, complete all as specified and directed.
Supply and fix in repair of size 50 m dia, PP-R Ball valves (brass insert) as per requirement of the site for complete all as specified and directed.
Material and labour in replacement of ISI marked ductile iron socketed fittings supplied as per IS: 9523/2000 of class K-12, PN-10 for pressurized water delivery with inside Cement Mortar lining and outside zinc followed by black bitumen coating for size 80 mm dia to 150 mm dia such as bends, Tapers tale pieces, Tee pieces (single branch) Y junction double branch,cross collars, caps and plug set including rubber ring push on joints complete as specified and directed.
Material and labour for rubber gasket (Tyton) joints suitable for 150 mm bore CI/DI pipe and fittings including jointing material complete all as specified and directed by Engineer-in-Charge.
Material and labour for rubber gasket (Tyton) joints suitable for 100 mm bore CI/DI pipe and fittings including jointing material complete all as specified and directed by Engineer-in-Charge.
Material and labour for rubber gasket (Tyton) joints suitable for 80 mm bore CI/DI pipe and fittings including jointing material complete all as specified and directed by Engineer-in-Charge.
Dismantling monoblock pump set centrifugal type of cap 25 HP, AC, 3 phase, 415 volts from site after disconnecting of electric connection, suction and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, dismantling pump set for overhauling, replacing u/s shaft sleeve, gland packing, bush, water seal, applying grease etc and reassembling the complete pump after repairs and replacement of parts as required, refixing the same at site incl. electric and piping connections complete, checking for satisfactory working all as directed by Enginner-in-charge. (Note : Cost of dismantling and refixing deemed to be included in quoted rate)
Dismantling open well type monoblock pump set of cap 10 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge refixing the same at site including . electric and piping connections complete, checking for satisfactory working all as directed by Enginner-in-charge. (Note : Cost of dismantling and refixing deemed to be included in quoted rate)
Dismantling open well type monoblock pump set of cap 5 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge refixing the same at site including . electric and piping connections complete, checking for satisfactory working all as directed by Enginner-in-charge. (Note : Cost of dismantling and refixing deemed to be included in quoted rate)
Dismantling/taking down bore well submersible pump set of cap 4/5 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enameled copper wire as per existing gauge re-fixing the same at site including . Electric and piping connections complete, checking for satisfactory working all as directed by Enginner-in-charge. (Note : Cost of dismantling/taking down of bore well pump and re-fixing deemed to be included in quoted rate)
OM ENGINEERING
SURESH ELECTRICALS
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .