Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 CrAdmitted-Finance | ₹10.1 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | KERALA ELECTRICAL AND ALLIED ENGG CO LTD L1 |
|---|---|---|---|---|
| 1.00Appendix A- Civil works-Slaughter house in Existing building | ||||
| 1.01 | 15.2.1. Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | 44.2 | cum | - |
| 1.02 | 15.2.2Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.
Nominal concrete 1:4:8 leaner mix ( including equivalent design mix) | 7.13 | cum | - |
| 1.03 | 15.3 . Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. | 4.1 | cum | - |
| 1.04 | 15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.
In cement mortar | 81.97 | cum | - |
| 1.05 | 15.18. Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. | 3,000 | kg | - |
| 1.06 | 15.19 Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge. | 541.8 | kg | - |
| 1.07 | 15.28.1 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :
G.S. Sheet | 840 | sqm | - |
| 1.08 | 15.60 Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved | 113.76 | cum | - |
| 1.09 | 15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles 10 mm to 25 mm | 1,098 | sqm | - |
Tender Value
₹9.2 Cr
EMD Value
₹2 L
Closing Date
7 Dec 2019, 5:00 pmClosed
SUPERINTENDING ENGINEER
ThiruvananthapuramCorporation
Proposal on Turn Key Basis is invited from prospective bidders for Detailed Engineering Civil Structural Construction Procurement or Supply and Installation of all equipment related to mechanical electrical piping etc followed by commissioning
2019_LSGD_322948_1
Tvpm Corp E13/1835/19-20
Open Tender
Civil Works - Others
365 days
ThiruvananthapuramCorporation
Please refer Tender documents.
8 documents required · 8 mandatory
₹11,200
Yes
online
₹2 L
Yes
ThiruvananthapuramCorporation
25 Feb 2020
20 Nov 2019
19 Dec 2019
20 Nov 2019
7 Dec 2019
29 Nov 2019
27 Nov 2019
Amount
Appendix A- Civil works-Slaughter house in Existing building
15.2.1. Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
15.2.2Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge. Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
15.3 . Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge. In cement mortar
15.18. Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
15.19 Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge.
15.28.1 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of : G.S. Sheet
15.60 Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
5.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.7. Solid block masonry using pre cast solid blocks (Factory made) of size 40X20x15cm or nearest available size confirming to IS 2185 part of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 (1 cement: 6 coarse sand ) etc complete
50.6.1.8. Solid block masonry using pre cast solid blocks (Factory made) of size 40X20x15cm or nearest available size confirming to IS 2185 part of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 (1 cement: 6 coarse sand ) etc complete
13.1.1- 12mm cement plaster of mix 1:4 (1 cement : 4 fine sand)
14.1.1 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead: With cement mortar 1:4 ( 1 cement : fine sand)
14.2.1 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for hold fasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm, with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground within 50 meters lead: Door chowkhats
14.4.1 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba / rubbish to the nearest municipal dumping ground. For door / window / clerestory window
14.5.1 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty : Float glass panes of thickness 4 mm
22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
od209996/2017-18 Supplying, providing and laying 4mm thick self smoothening epoxy flooring over the existing cement concrete floor. The features should be hardwearing, abrasion resistant, hygienic, easy to clean, non staining, non dusting. The products to be used will be procured from either of the following manufacturers/make FOSROC, ARDEX-ENDURA, RELIEANCE CHEMICALS, ADITYA BIRLA CHEMICAL, ALCHEMIC LTD, DR FIXIT OR STP. The bonding coat will be done from the solvent free epoxy primer and the porduct is to be self leveling epoxy screed. The top coat is to be self smoothening, abrasion resistant, hardwearing, chemical resistant and in the desired colour and shade. The flooring specification and should be classifed as per BS 6319, Any laitance, dust or other contamination of the existing floor are to be cleared by the contractor and any repairing, levelling etc. are alos to be done by the contractor before laying of epoxy. The primer is to be applied on the cleaned surface with the help of the rollers in the single coat and the fine sand will be spreaded to provide the mechanical key for the further coat (top coat). The 3 mm thick self leveling epoxy screed is to be applied as the body coat over the primed surface with the help of the spike rollers and the notch trowel, smoothern out the undulations upto 3mm and preparing a strong substrate to receive the epoxy self levelling top coat. The curing is to be done for 24 hrs, and then apply the top coar of the self smoothening epoxy flooring systems with the help of the notch trowel and spike rollers in the desired thickness of 1mm and colour and shade to give a high gloss, flat and smooth aesthically clean surface including curing for at least 24 hrd complete. The rates are inclusive of the treatment of the expansion and control joints, rectification, levelling and providing slope on existing floor, using epoxy screed etc.
11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm.
8.13.1 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
16.87.1 Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-charge. Area less than 0.50 sqm.
11.36 Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
11.40 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
14.43 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer.
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @2.20 kg/10 sqm)
14.54.1 Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade: One or more coats on old work
21.17 Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ).
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in charge)0.50mm(+0.05%), total coated thickness with zing coating 120 grams. per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: Ridges plain (500-600 mm)
12.52.1 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge. GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending
2.28.1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
16.68 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
11.20.2 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand). Medium shade pigment using 50% white cement 50 % Grey cement
9.135.2 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.50 mm all complete. With 12 mm mild steel U beading
Appendix B- CATTLE LAIRAGE CONSTRUCTION
2.28.1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand)
50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
13.4.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 coarse sand)
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
13.44.1 Finishing walls with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm)
10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in charge)0.50mm(+0.05%), total coated thickness with zing coating 120 grams. per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: Ridges plain (500-600 mm)
11.4 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
13.18 Neat cement punning
16.20 Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete block 45x45x60 cm of mix1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50 cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I stapes on wooden plugs or tied to 6 mm barnibs with G.I binding wire (cost of posts, welded steel wire fabric, painting, earth work in excavation and concrete to be paid for separately):
Appendix C- SHEEP LIRAGE CONSTRUCTION.
2.28.1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand)
50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
13.4.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 coarse sand)
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
13.44.1 Finishing walls with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm)
10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: Ridges plain (500-600 mm)
11.4 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
13.18 Neat cement punning
16.20 Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete block 45x45x60 cm of mix1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50 cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I stapes on wooden plugs or tied to 6 mm barnibs with G.I binding wire (cost of posts, welded steel wire fabric, painting, earth work in excavation and concrete to be paid for separately):
Appendix D- RENDERING PLANT Shed
2.28.1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand)
50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.6.1.1 Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
10.6.1 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
11.4 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
13.18 Neat cement punning
13.4.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 coarse sand)
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
16.20 Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete block 45x45x60 cm of mix1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50 cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I stapes on wooden plugs or tied to 6 mm barnibs with G.I binding wire (cost of posts, welded steel wire fabric, painting, earth work in excavation and concrete to be paid for separately):
Appendix E- LABOUR QUARTERS Construction
2.28.1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand)
50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
4.3.1 Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.1 Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.4.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 coarse sand)
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
10.6.1 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
11.41.3 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 800x 800 mm
11.37 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
11.36 Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
50.9.2.2 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required sized with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer in-charge using Pincoda wood
50.9.1.2 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) using good quality Pincoda wood
12.45.1 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: 12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1
13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Appendix F- EFFLUENT TREATMENT PLANT 50 KLD Construction
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
13.4.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of : i) I course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS: 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) III course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/ sqm.
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
13.50.3 Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
13.52.2 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work
Appendix G- UNDER GROUND WATER TANK 1 lakh LITRE CAPACITY.
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
5.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
13.4.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of : i) I course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS: 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) III course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/ sqm.
Appendix H- COMPOUND WALL WITH GATE
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock
50.6.1.1 Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.1.5 Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
13.4.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
10.6.1 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Appendix I- SEPTIC TANK AND SOAK PIT.
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
50.6.1.4 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.3 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
13.4.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Appendix J- PLUMPING AND SANITARY FITTINGS (Slaughter house).
50.18.8.3.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2
50.18.8.6.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2
50.18.8.9.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
17.2.1 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid
17.9.1 Providing and fixing kitchen sink with C. I brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: White glazed fire clay kitchen sink of size 600x450x250 mm
17.25.1 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings: Flat back wash basin of size 630x450 mm
17.28.1.2 Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete. Semi rigid pipe 40 mm dia
18.15.2 Providing and fixing brass bib cock of approved quality: 20 mm nominal bore
Appendix K- LANDSCAPING WORK.
16.68 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
30.2.33 Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler
Appendix L- ELECTRICAL WORK WITH TRANSFORMER
Appendix M- GST 12% OF CIVIL COST (RS. 1,95,51,428/-)
MECHANICAL TENDER CATTLE SLAUGHTERING MACHINERY (CAPACITY 50 HEADS/DAY)
SINGEL ROTARY HALAL BOX The box will be single rotary type to do slaughtering as per Islamic method. The door movement is provided by pneumatic cylinders and the rotary motion is controlled by electric drive. This box shall be attached with a landing platform for Halal operation. The boxe will be of SS-304 and the frame shall be of MS.Rotary halal box motor 2.2 kw capacity.
LANDING GRATE It is made up of GI pipe and hinges at one end to facilitate the cleaning and maintain hygiene. Further this landing platform covered by MS barrier post from all sides.
LANDING HOIST There will be a brake motor with heavy duty gear box for the movement of animal lifting chain. The capacity will be 2 MT. 2 kw motor
BLEEDING GRAVITY LINE The Bleeding Gravity Line is made of MS Hot Dip Galvanized. The bleed line is having 100 x 12 mm flat rail. Size/Length: As per drawing.
MOTORIZED DRESSING LINE The bleed and dressing conveyor system shall be of flat rail type driven by an electric motor having variable speed control device. Total structure will be hot dip galvanized except chain. The bleed line is having 100 x 12 mm flat rail and dressing line will have 75 x 12 mm flat rail. All support of the flat rail should be 12 mm thick with 200 x 100 mm as the main support. It will be provided with VFD control system. Size/Length: As per drawing. 2.5 kw motor for dressing line
LEG CUTTING PLATFORM FIXED Platforms shall be of Aluminum checkered plate having SS-304 structure with SS railing with SS-304 wash basin and sterilizer. Size/Length: As per drawing.
LEG CHUTE Made of SS-304
FRONT HIDE & ANAL BUNGING PLATFORM FIXED Platforms shall be of Aluminum checkered plate having SS-304 structure with SS-304 railing. Size/Length: As per drawing.
HIDE PULLER PNEUMATIC Hide puller consist of two platforms and a rotary drum, the whole assembly goes down by pneumatic system, the drum motion is controlled by low voltage electric controls. All structure will be hot dip galvanized. The system is powered by Electrical Motor. 2.5 kw drum motor
HIDE PULLER CHUTE It is made of SS-304 with pneumatically control shutters.
VISCERA PLATFORM FIXED Platforms shall be of Aluminum checkered plate having SS-304 structure with SS railing. There will be a wash basin and sterilizer made of SS-304. Size/Length: As per drawing.
CARCASS SPLITTING PLATFORM PNEUMATIC & DR. INSPECTION PLATFORM Platforms shall be of Aluminum checkered plate having SS-304 structure with SS railing. There will be a wash basin and sterilizer made of SS-304. It will be pneumatically operated.
WASHING & TRIMMING PLATFORM PNEUMATIC Platforms shall be of Aluminum checkered plate having SS-304 structure with SS railing. Our two step design enables the butchers to perform trimming the entire carcass thoroughly. There will be a wash basin and sterilizer made of SS-304.
HEAD CHUTE Made of SS-304
WASHING SCREEN MANUAL Made of SS-304
LEG CHANGING SYSTEM It has quick pneumatic leg changing system from bleeding line to dressing line for further animal processing. This machine greatly reduces the human labor and improves productivity.
VISCERA BELT CONVEYOR It is food grade belt conveyor to carry and inspect the intestine and will be controlled by VFD and emergency stop. The frame will be carbon steel. Housing T-206, P-206 (2 Pcs. Each) Motor: Havells Make, 2 KW. RPM – 1410, Duty-S1.
DISPATCH GRAVITY LINE Custom designed Chiller line made of MS hot dip galvanized Chiller I Beam 1150X75 medium. MS Sheet 6 mm. Switch Assemble complete. All in lot.
QUARTERING STATION The half carcass is further split into two more pieces hence the term quartering. The quartering station may be used for chillers or deboning as per clients’ requirement. 1 kw motor
ANIMAL PRESSING SYSTEM It is designed to smoothly land hooks on bleeding conveyor. It is pneumatically operated.
SEQUENCE SYSTEM Sequence system is used for disciplined sequence of animal slaughter to the bleeding line. It is pneumatically operated.
VISCERA CHUTE It is made of SS – 304 with pneumatically operated shutter.
CHILLER LINE Whole chiller line, passage and ante rooms will be made of 150x75 ISMB and a flat of 75x12. The whole structure will be hot dip galvanized.
DRESSING HOOKS It will be made of SS-304 and will be used with dressing conveyor.
BLEEDING HOOKS It will be made of MS with hop dip galvanized and will be used with bleeding conveyor.
CARCASS SPLITTING BANDSAW (ELECTRIC) Standard Make • Used worldwide for splitting fat cattle, bulls,oxen and horses. • The largest Jarvis splitting saw; suited for thelargest carcasses. • Superior blade life: 400 - 600 carcasses per blade.
CARCASS SPLITTING BANDSAW BALANCER The Carcass Splitting Bandsaw Balancer will have: RANGE : 3 Meter / 1.5 Meter CAPACITY: 90 - 120 Kg. / 15 – 22 Kg. 2.5 kw motor
STERILIZER FOR CARCASS SPLITTER Made of SS-304
PRIMARY STRUCTURE FOR ABATTOIR & CHILLER This will hang the whole chiller line & refrigeration fan coil unit.
AIR COMPRESSOR WITH VERTICAL AIR RECEIVER FOR PNEUMATIC CONTROLS Hitachi or Equivalent make. 15 kw motor
HOT WATER LINE PIPING AND ITS CONNECTION WITH INSULATION Hot Dip galvanized pipe, Valves and Fitting of Zoloto make, Pipe of Jindal make.
COMPLETE PNEUMATIC LINES FROM AIR COMPRESSOR RECEIVER TO THE EQUIPMENT’S Pneumax or equivalent make
ELECTRICAL PANEL Schnider, ABV make.
ELECTRICAL CABLES TRAYS, CONTROL CABLES AND CABLE CONNECTIONS FROM MAIN ELECTRICAL PANEL TO THE EQUIPMENT. Schnider, ABV make. 2 kw motor
PNEUMATIC RESTRAINER JARVIS MAKE
ONE MT HOIST FOR EMERGENCY SLAUGHTER WITH COMPLETE ASSEMBLING Indef
EMERGENCY SLAUGHTER LINE TYPE GRAVITY Lot
ON LINE WEIGHING SCALE Martin make. 0.5 kw
SHEEP SLAUGHTERING MACHINERY (CAPACITY 25 HEADS/DAY)
SHEEP RESTRAINER Stainless steel – 304 pneumatic restrainer, is having SS Square Pipe 50X2000 mm to restrain sheep/goat. Teflon Sheet -10 mm, Conv. Length 2700 mm. Sq. Housing UCF 210, SS Sheet 8 mm tick. 4 kw Motor & Gear Box of Havells.
HALAL TABLE Non rotary Halal table is made of SS-304, SS Angle 50X3, SS Pipe 50X1.5 mm, SS Sheet 3mm & 2mm with suitable bleeding arrangement.
BLEEDING AND DRESSING MOTORIZED CONVEYOR It is made of MS (MS Angle 50X3 mm, MS Sheet 4mm thick) hot dip galvanized with fixed hook and chain 6” pitch, 2” dropper pipe at suitable pitch to ease the operation. The track will be Nut Bolting System and the chain will be alloy carbon steel. MS Square pipe 100X100X3 mm thick. Size/Length: As per drawing.
WORKING STATION Sterilizer With Wash basin Made of SS-304
CHILLER LINE Custom designed Chiller line made of MS hot dip galvanized Chiller I Beam 1150X75 medium. MS Sheet 6 mm. Switch Assemble complete. All in lot.
PRIMARY STRUCTURE FOR ABATTOIR & CHILLER This will hang the whole chiller line & refrigeration fan coil unit.
HOT WATER LINE PIPING AND ITS CONNECTION WITH INSULATION Hot Dip galvanized pipe, Valves and Fitting of Zoloto make, Pipe of Jindal make.
COMPLETE PNEUMATIC LINES FROM AIR COMPRESSOR RECEIVER TO THE EQUIPMENT’S Pneumax or equivalent make
ELECTRICAL PANEL Schnider, ABV make.
ELECTRICAL CABLES TRAYS, CONTROL CABLES AND CABLE CONNECTIONS FROM MAIN ELECTRICAL PANEL TO THE EQUIPMENT. Schnider, ABV make.
ON LINE WEIGHING SCALE Martin make 0.5 kw motor
RENDERING PLANT MACHINERY (CAPACITY 500 KG/HOUR)
RAW MATERIAL BIN CAPICITY: 4 M.T. It is made of Trough 8mm, 6mm. Screw Plate 12 mm thick, Screw Pitch 610 mm, Schedule Pipe ⏀200 NB with leg supporting stand. Conveyor Length as per design. Gear Box: Make-Power Build, 3.7 KW, Ratio 80.68 and O/P RPM – 18. Motor: Make -Crompton, 5.5 KW . O/P RPM – 1450 and the duty is S1. Capacity: 30 m3
CONVERYOR FROM RAW MATERIAL BIN TO BONE MEAT SHREDDER. It is made of Trough 6mm thick. Screw Plate 6 mm thick, Screw Pitch 230 mm, Schedule Pipe ⏀65 NB with leg supporting stand. Conveyor Length is as per design. Gear Box: Make-Power Build, 3.7 KW, Ratio 55.80 and O/P RPM – 26. Motor: Make -Crompton, 3.7 KW. O/P RPM – 1430 and the duty is S1.
BONE MEAT SHREDDER CAPICITY: 1 TON/HOUR It is made of MS Sheet 10 mm thick. Drum 10 mm thick, Blade 16 mm thick. Housing 2 Pcs. Gear Box: 3.7 KW. Motor: 5.5 KW
SCREW CONVERYOR FROM BONE MEAT SHREDDER TO BUFFER BIN It is made of Trough 6mm thick. Screw Plate 8 mm thick, Screw Pitch 300 mm, Schedule Pipe ⏀90 NB, MS Sheet 10mm with leg supporting stand. Conveyor Length is as per design. Motor: Make -Crompton, 3.7 KW. O/P RPM – 1415 and the duty is S1.
RAW MATERIAL BUFFER BIN CAPICITY: 3 M.T. It is made of Trough 6mm thick. Screw Plate 6 mm thick, Screw Pitch 188 mm, Schedule Pipe ⏀60 NB with leg supporting stand. Conveyor Length is as per design. Gear Box: Make-Power Build, 1.5 KW, Ratio 66.02 and O/P RPM – 21. Motor: Make -Crompton, 1.5 KW/ 2HP. O/P RPM – 1420 and the duty is S1.
SCREW CONVERYOR FROM RAW MATERIAL BIN TO COOKER It is made of Trough 6mm thick. Screw Plate 6 mm thick, Screw Pitch 230 mm, Schedule Pipe ⏀76 NB, MS Sheet 10 mm with leg supporting stand. Conveyor Length is as per design. Gear Box: Make-Power Build, 3.7 KW, Ratio 55.80 and O/P RPM – 26. Motor: Make -Crompton, 3.7 KW/ 5HP. O/P RPM – 1430 and the duty is S1.
BATCH COOKERCAPICITY: 1 TON PER BATCH The cooker will be made of mild steel and 20mm inner shall and 16 mm outer shall and both shaft cantered with plumber bearing. The Rotor will have the internal heating facility with the rotary joints and will have capacity of 1T capacity. It will have driven by helical gearbox andf 3 phase motor 1.5 kw
SCREW CONVERYOR FROM COOKER TO SCREW PRESS It is made of Trough 6mm thick. Screw Plate 6 mm thick, Screw Pitch 230 mm, Schedule Pipe ⏀65 NB, with leg supporting stand. Conveyor Length as per design. Gear Box: Make-Power Build, 3.7 KW, Ratio 55.80 and O/P RPM – 26. Motor: Make -Crompton, 3.7 KW/ 5HP. O/P RPM – 1430 and the duty is S1.
SCREW PRESS Capacity: 1.0 M.T. per Hour It has a three stage screw press to sqeeze the tallow from the cooked material. 30 kw motor
SCREW CONVEYOR FROM SCREW PRESS TO CAKE BIN To transfer the cake coming out from screw press to a cake bin collection tank. 2 kw motor
CAKE BIN Capacity: 6.0 M.T. In this bin the mateial coming out from press is stored and mixed before grinding so that the grinded material have uniform parameters. 3.7 kw motor
SCREW CONVEYOR FROM CAKE BIN TO HAMMER MILL To transfer the cake coming out from screw press to a cake bin collection tank
HAMMER MILL It is made of MS Sheet 6mm thick. In let – 300X300mm. Motor: Make – Crompton, 7 KW7. O/P RPM – 1460 and the duty is S1. Coupling & Housing.
SCREW CONVEYOR FROM HAMMER MILL TO MBM STORAGE SILO It is made of Trough 6mm thick. Screw Plate 6 mm thick, Screw Pitch 230 mm, Schedule Pipe ⏀65 NB, with leg supporting stand. Conveyor Length is as per design. Gear Box: Make-Power Build, 3.7 KW, Ratio 55.80 and O/P RPM – 26. Motor: Make -Crompton, 3.7 KW/ 5HP. O/P RPM – 1430 and the duty is S1.
VIBRATING SCREEN The material from raw tallow tank and press is pumped to vibro screen to remove bigger particles from tallow. Capacity: 500 Ltr./hour. 1 kw motor
TALLOW BUFFER TANK It is made of MS Sheet 6mm thick. Capacity is 3MT
TALLOW PUMP Pump of high capacity to suck tallow. 3 kw motor
TALLOW STORAGE TANK It is made of MS Sheet 6mm thick. Capacity is 3MT
CONDENSER FOR COOKER VAPORS It is made of MS Sheet 6mm thick. Condenser Length 3000 mm, ⏀1000mm X 6mm thick. 2” GI Pipe. Supporting tank. MS Sheet 8mm thick. 3.7 kw motor
WATER COOLING TOWER Standard Make
COOLING TOWER PUMPS Standard Make. 1.5 kw motor
ODOR VAPORS COLLECTION DRUM It is 4 cubic meter made of MS
EXTRACT FAN Havells make or equivalent
AIR PIPING FROM COOKER TILL BIO FILTER & SUCTION AIR FROM DIFFERENT POINTS - LOT Jindal or equivalent
COOLING TOWER VALVES, FITTINGS & PIPING - LOT Jindal or equivalent
TALLOW PIPE FITTINGS & VALVES Jindal or equivalent
MAIN ELECTRICAL PANEL Schnider, ABV make.
ELECTRICAL CABLES TRAYS, CONTROL CABLES AND CABLE CONNECTIONS FROM MAIN ELECTRICAL PANEL TO THE EQUIPMENT. Havells make or equivalent
BOILER (Wood Fired) Capacity: 1000.00 Kg./Hour. Ross make Steam Boiler type Horizontal Multi-tubular, 3 pass fully wet back, shell & tube type with integral furnace. Steam Boiler model RSW 1000 Steaming capacity 1000Kgs/hr f & at 100Deg C. Maximum working pressure 10.5 kg / cm2 maximum Hydraulic test pressure 15.75 Kgs/sqcm Steam quality Dry, saturated Dryness fraction of steam 0.98 Saturated steam temperature 185 deg C maximum Fuel Wood/Coal/Agrowaste pellets Fuel consumption 182 Kgs/hr. feed pumb motor 1.5 kw and ID fan 3.7 kw motor.
CHIMNEY (With Accessories) for Boiler. Chimney Type Self supporting Top Diameter 350 mm Height 30 mtrs Details Bottom diameter od 800 x top diameter od 350 Base Plate OD 1300 x 16 and 16 thk double plate as skirt with 10 mm gusset plates Ducting From unit to chimney –max. 4 mtrs Accessories Approach Ladder (ISA 40 x 5 thk ) Platform Sampling nozzle 4” NB Aviation lamp wiring with cable Lightening arrestor GI strip down conductor Canopy (Rain hood) at top Necessary foundation bolts
ELECTRICAL EQUIPMENTS
DISTRIBUTION PANEL It is custom designed (Schinider/ Telemechanic/ L&T)
COMPLETE ELECTRICAL CABLING, EARTHING, ETC. Havells make or equivalent
HYGIENE EQUIPMENTS FOR BOVINE & OVINE
AIR CURTAINS OF DIFFERENT SIZES. Made of SS - 304
FLY CATCHERS Specification: - Voltage: 220V/50HZ - Size: 19cm*55cm - Effective range: 50m²
LOCKERS FOR BUTCHERS Made of SS - 304
SHOE RACKS Made of SS - 304
HAND DRIER & BOOT WASH STATION Fully automatic with IR Sensor Size : H 265 x W 200 x D 115 mm Type : Single Blower Power : 1250 W Electrical Supply : 230VAC, 50Hz, Single Phase
Slaughter knifes
REFRIGIRATION EQUIPMENTS (CAPACITY AS PER DRAWING)
REFRIGERATION UNIT FOR BOVINE CHILLER WITH PU PANEL & DOORS Carrier, blizzard or equivalent make. 20 kw motor
REFRIGERATION UNIT FOR OVINE CHILLER WITH PU PANEL & DOORS Carrier, blizzard or equivalent make.
ELECTRICAL CONTROL PANEL WITH TEMPERATOR INDICATORS Schnider, ABV make.
ETP MACHINERY
Coarse Bar Screen GIES make
Raw Effluent Transfer Pump LUBI make
Coarse Bubble Grid GIES make
pH Booster Dosing System Chemi Dose make
Coagulant Dosing System Chemi Dose make
Flocculent Dosing System Chemi Dose make
Sludge Transfer Pump Kirloskar make
Aeration Tank Feed Pump Kirloskar make
Process Air Blower Blowacc make
Induction motor Kirloskar make
Fine Bubble Diffusers Scogen make
Tube Settler CFM Make
Sludge Recirculation Pump Kirloskar make
Hypo Dosing System Chemi Dose make
Filter Feed Pump Kirloskar make
Pressure Sand Filter GIES make
Activated Carbon Filter GIES make
Total Electrical cost by including the following MCC panel ( Components are of L & T make), No. of TOD Meter, Electrical cable
Others by including the following, Piping for Aeration ( MOC – GI of reputed make), Piping for transfer of waste water ( MOC- Sch 40), Ball Valves & Others, Chemicals for initial start up.
INSTRUMENTATION No. of Level Switch – 6 Nos, Sinicon make Pressure Gauge – 02 Nos, H Guru make Mechanical Flow Meter – 01 N
CCTV FACILITY
16 channel NVR with 2 Sata - - 200Mbps -Up to 8MP Resolution for Preview and Playback
2Megapixel Bullet IP Camera(30mtr)- Res:25fps@2MP - Lens:3.6mm
2Megapixel Domet IP Camera(30mtr)- Res:25fps@2MP - Lens: 3.6mm
24-Port unmanaged 10/100/1000 Base- T PoE Ethernet Switch (Net gear/HP)
19" 10U Metal Rack Including Full loaded Patch Panel, Cable Manager,Patch Code, Fan etc and Installation Charge
Dlink Connector
Harddisk 4 Tb WD
Fixing, testing Charge per Camera
Cable cat6 D-Link including Materials and laying Charge
FIRE FIGHTING EQUIPMENTS
ABC (Dry Chemical Powder) – Stored pressure – Fire Extinguisher – 4 Kg Capacity
Fire bucket
LABORATORY EQUIPMENTS
PH meter
Incubator
Laminar flow
Autoclave
Microscope-binocular
Chemical, Media and reagents
Glass wares
Electrification
1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
90.10.1.2 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
90.10.1.3 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
90.10.1.6 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.
od163485/2018_2019 : Supply and fixing of poly carbonate cable junction box having size 139x119x70 mm grey/black with terminal, for Cu /Al conductors with knockouts types suitable for 4 to 16 sq.mm range Cable Junction Boxes for outside applications, having IP 66 degree of protection , water-proof, UV-resistant and including suitable din rail or base etc for fixing MCB/isolator/Contractor etc if required , fixed on existing pole or pillar with necessary specials and accessories as required ( Make HENSEL/Equivalent )
od163499/2018_2019 : Supply and fixing of 300 x 450x170 mm size Opaque /transparent type with knockouts types sip IP 67 rated Boxes with including suitable din rail or base etc suitable for fixing MCB/ isolator/Contractor etc and water proof cable gland etc if required , fixed on existing pole or pillar with necessary specials and accessories as required ( Make HENSEL/Equivalent )
od163501/2018_2019 : Supply and fixing of 300x150x170 mm size Opaque /Transparent type IP 66 type water-proof and including suitable din rail or base etc for fixing SDU/MCB/isolator/Contractor etc if required , fixed on wall with necessary specials and accessories as required ( Make HENSEL/Equivalent
od163511/2018_2019 : Supplying and fixing 16 /20 amp, 230 V, 50 Hz male type 3 pin (2P+E) plug socket outlet suitable for surface mounting, water tight socket ( IP 67,) with suitable accessories and giving connections etc. as required (Hensel or its equivalent make)
od163513/2018_2019 : Supplying and fixing surface mounting type 16/20 A , 230 V , 50 HZ water tight female 3 pin ( 2P+E) socket IP 67 protection , including fixing the socket on wall using suitable accessories and giving connection as required (Hensel or equivalent make) .
Fittings
1.36 : Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit,aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and painting etc. as required.
1.40 : Providing and fixing plain 16/0.20 mm (0.50 sqmm) twin circular flexible FRLS PVC insulated, PVC sheathes copper cable direct on the wall with PVC clips etc as required.
1.51 : Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
1.48 : Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
1.43 : Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring with 2 X1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
od163362/2018_2019 : Supply, conveyance, installation, testing and commissioning of 35S LED well glass light fittings of Philips (BY200PLED 35S CW PSU S2PC) or its equivalent having lumen output not less than 3500 lumen as required with all accessories etc. and FIXED on the exiting rod /pipe (separate measurement and including fabrication nut and bolt etc with using standard flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. Philips / its equivalent.
od205695/2018_2019 : Supply Conveyance, installation, testing and commissioning of pre-wired light fitting of all types complete with all accessories and fluorescent lamps etc. directly to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.for Round LED down light fitting out put not less than 1200lumen efficiency not less than 105lu/watt steel/aluminum enclosure complete
od205697/2018_2019 : Supply conveyance, installation, testing and commissioning of all out door light fittings complete with all accessories in the existing GI pipe and giving connections as required. 40W LED fitting IP66 with lumen out put not less than 105 lumen/watt with LM79 /80 tests compliance from third party
od165826/2018_2019 : Supply and fixing of gate lamp aluminium and synthetic body integrated type 8 W LED lamp with RoHS complied , duly wired up for use on 230 V AC supply and giving connection etc.including making good the damages, colour washing etc as required. ( Model Robbin- 15472 Make -Philips or Equivalent)
90.3.20.3 : Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.24.3 : Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture
90.3.20.4 : Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 2X20W LED Lamp with box type fixture
90.3.24.4 : Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 2X20W LED Lamp with box type fixture
90.3.7 : Supplying and providing extra steel chain (16 SWG) 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
90.3.23.4 : Supply & installation of fittings suspended on steel chain Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet .5mm thick with all accessories and lamps etc. suspended from ceiling using 2 nos steel chain (16 SWG or nearest available size) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200mm 2X20W LED Lamp with box type fixture
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.2 : Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90.3.18.3 : Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
od201690/2018_2019 : Supply conveyance, installation, testing and commissioning of all out door light fittings complete with all accessories in the existing GI pipe and giving connections as required. 70W LED fitting IP66 with lumen out put not less than 105 lumen/watt with LM79 /80 tests compliance from third party
od205699/2018_2019 : Supply and errection of octoganal galvanized pole 7 mtr height complete with Double arm bracket 500mm projection, 200x200x12mm size base plate , 4Nos 20mm dia 600mm length foundation bolts and nuts space for mounting control switch box with inspection type door at a height of 550mm from the road level including fixing smart pack jungtion box with 6 A MCB and sted terminal (for mounting inside base compartment of pole) ( Bajaj BOP 7030/ or equlent make) etc as required on existing foundation
od205701/2018_2019 : Supply and errection of octoganal galvanized pole 7 mtr height complete with Single arm bracket 500mm projection, 200x200x12mm size base plate , 4Nos 20mm dia 600mm length foundation bolts and nuts space for mounting control switch box with inspection type door at a height of 550mm from the road level including fixing smart pack jungtion box with 6 A MCB and sted terminal (for mounting inside base compartment of pole) ( Bajaj BOP 7030/ or equlent make) etc as required on existing foundation
90.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.4.9 : Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
od157527/2018_2019 : Supply, Conveyance,Testing and Commissioning of 380 mm sweep, 1400 rpm working on 230 V A/C Heavy Duty Exhaust fan in the existing opening using suitable size anchor bolt / Screws etc and giving connection as reqquired.
od205689/2018_2019 : Supply, conveyance, installation , testing and commissioning of exhaust fans of size 300mm light duty 1300rpm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
od205691/2018_2019 : Supplying and fixing cast aluminium bulk head fitting with mesh guard with 7W LED bulb and giving connection etc. as required.
od205693/2018_2019 : Supplying and fixing PVC batten/ angle holder including 3 W LED Bulb and plastic shade and giving connection etc. as required.
od163384/2018_2019 : Supply, Conveyance,Testing and Commissioning of 400 mm sweep, 60 watt 1440 rpm 3 Nos metal blade with mesh guard working on 230 V A/C wall mounting fan in the existing wall using suitable size anchor bolt / Screws etc and giving connection as required (Almonard/Crompton/or its equivalent)
DB , MCB, MPCB, ACB and MCCB
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.23.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 8 way, Double door SPN MCBDB
2.23.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 6 way, Double door SPN MCBDB
2.23.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 10 way, Double door SPN MCBDB
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
od159581/2018_2019 : Supply and fixing 3 phase 3 pole 4 A , Rotary handle type MPCB rating and breaking capacity 100 KA Icu and including short circuit and overload protection (4-6.3 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or Equivalent make)
od157529/2018_2019 : Supply and fixing 3 phase 3 pole 19 A , Rotary handle type MPCB rating and breaking capacity 50 KA (Icu)and including short circuit and overload protection (19-25 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or its Equivalent make)
od157531/2018_2019 : Supply and fixing 3 phase 3 pole 11 A , Rotary handle type MPCB rating and breaking capacity 100 KA (Icu)and including short circuit and overload protection (11-16 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or its Equivalent make)
od157533/2018_2019 : Supply and fixing 3 phase 3 pole 9 A , Rotary handle type MPCB rating and breaking capacity 100 KA (Icu)and including short circuit and overload protection (9-13 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or its Equivalent make)
od157535/2018_2019 : Supply and fixing 3 phase 3 pole 6 A , Rotary handle type MPCB rating and breaking capacity 100 KA (Icu)and including short circuit and overload protection (6.3-10 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or its Equivalent make)
od159577/2018_2019 : Supply and fixing 3 phase 3 pole 45 A , Rotary handle type MPCB rating and breaking capacity 50 KA (Icu)and including short circuit and overload protection (45-63 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or its Equivalent make)
od159579/2018_2019 : Supply and fixing 3 phase 3 pole 24 A , Rotary handle type MPCB rating and breaking capacity 50 KA (Icu)and including short circuit and overload protection (24-32 A setting) in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required ( L&T or its Equivalent make)
od164239/2018_2019 : MPCB Accessories Supply and fixing rotary handle, External type in the existing MPCB of rating up to 63 A
90.14.10.3 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.10.14 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
od205121/2018_2019 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 160A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB withthermal magnetic release with overload setting of 80 - 100% having adjustable OL & SC
od205703/2018_2019 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 125A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB withthermal magnetic release with overload setting of 80 - 100% having adjustable OL & SC
od205705/2018_2019 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 200A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB withthermal magnetic release with overload setting of 80 - 100% having adjustable OL & SC
od170014/2018_2019 : Providing and fixing of 125 Amp,, 4 pole Switch dis connector fixed type MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. ( L& T or its equivalent make)
90.14.11.13 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
90.14.11.17 : MCCB AccessoriesSupply and fixing kastel interlock kit up to 250A.
2.1.1 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
2.1.2 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
2.1.3 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
od165284/2018_2019 : Providing and fixing 63 A TP -N Switch dis connector unit inside the existing panel board including drilling holes in cubicle panel, making connections, etc. as required.(L&T or its equivalent make)
od165286/2018_2019 : Providing and fixing 100 Amp TP -N Switch dis connector unit inside the existing panel board including drilling holes in cubicle panel, making connections, etc. as required. L&T or equivalent make
90.14.10.22 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.630A, 70 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.11.15 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A
90.14.11.18 : MCCB AccessoriesSupply and fixing kastel interlock kit 315 to 630A.
od157537/2018_2019 : Supply and fixing of 8 stage 440 V 5A/1A, Intelligent Power Factor Controllers (APFC unit fixed in panel board with all required accessories and giving connection as required.(L&T or its equivalent make)
od206344/2018_2019 : Providing and fixing following capacitor duty contactor 20 KVAR existing panel and giving connection complete
od206332/2018_2019 : Providing and fixing following capacitor duty contactor 7.5 to 10 KVAR existing panel and giving connection complete
od206334/2018_2019 : Providing and fixing following capacitor duty contactor 4 to7 KVAR existing panel and giving connection complete
90.14.24.31 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
90.14.24.34 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
90.14.24.37 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.20 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
od172029/2018_2019 : Supply, conveyance, installation, testing and commissioning of the Panel temperature controlled fan 100x100mm size 24V DC /240V AC with thermostat and giving connection as required.
Transformer and DG
od171713/2018_2019 : Supply, conveyance, Installation, Testing and Commissioning of indoor type USS, 11KV/433V,50Hz,315 KVA,3 Phase, Delta-Star,Vector DYN-11 Laser Scribed transformer with off circuit tapping from + 5% to -10% in step of 2.5%,changeable off circuit by tap links provided, with WTI & LV terminals suitable for 2 runs of XLPE cable and HV terminals connected to 11KV, 26.3KA,630A Load break switch, with incoming suitable for XLPE cable, with HT HRC fuses, 6Nos CTs, 2No PT, Ammeter. Voltmeter, Earth fault Relay, Over current relay, Master trip,4 window annunciation with hooter. copper bus bar, provision for fixing for TOD Meter and out put connected to 11KV seal off bushings to the transformer. The Transformer shall conform to IS 11171/1985 re-affirmed in 1991. The maximum alowable loss at full load is 2.07% and half load is 1.61%. H.T. PortionHT portion shall consists of:1No. 630A, 26.30 kA load break switch suitable for 3 phase, 3wire, 50 Hz system with HT HRC fuses of appropriate rating with earth switch inter lock with main switch and mechanical ON/OFF indication Shunt trip coil for the remote operation of the Load Break Switch(make T.O.D Metering facilities. For Clint3 Nos 30/5A (or suggested by KSEB)15 VA 0.2s Class accuracy cast resin C.T.1 No 3 Phase 3 limb 11 KV/110 V, 10 VA 0.2 accuracy class cast resin PT with protective fuses.Provision for 1 No. TOD Meter(rate not included).The TOD meter compartment and CT / PT unit compartment shall be fabricated so as to enable the KSEB authorities to seal it.L.T. Portion.The L.T. portion shall be provided Bus coupling /Cabling as per the direction of Engineer In charge with overload setting as per scheme. All inter connections from HT Load Break Switch to transformer and transformer to LT breaker shall be given using electrolytic copper bus bar insulated with heat shrink sleeves and tinned at the points of contacts. All internal earth connections are to be given as per standards. Necessary provision shall be made for giving cable connections on the HT side as well as LT side. Phase barriers and shrouding as per rules has to be given.The enclosure shall be fabricated from 2.00mm CRCA sheet, having minimum height same as top level of incomer LT panel complying of IP 20 standards and shall be powder coated over a coat of Zinc chromate primer after seven tank processing and phosphatising.The USS shall be installed as per the directions at site. (Make- Megawin/ Intrans / Crompton)
od205105/2018_2019 : Supply, conveyance, Installation, testing & commissioning of 250 KVA Diesel Generator set with integral acoustic enclosure as per CPCB norms with srandared acessories as per technical details given below. 1. Engine : a) Make of Engine - Kirloskar//Cummins/Leyland/Volvo b) Type of Engine - Diesel Engine c) No. of Cylinders - As per manufactures standards. d) Method of Cooling - Water cooled with radiator. e) Design - Suitable for generating set operation 2.Standard accessories with Diesel Engine a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fan provided with fan guard. e) Fuel Pump f) Fuel filter g) Lubricating oil filter h) Exhaust silencer i) Exhaust Muffler j) Battery Charger/Generator 3. Engine Instrument Panel with the following items a) Starting switch with key or button b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter e) Battery charging Ammeter 4. Safety Controls for Engine a) Trip for low lubricating oil pressure b) Trip for high water temperature. 6. Brushless Alternator a) Make - Kirloskar/KEL//Stanford/LS b) Type - Self exited and self regulated. c) Capacity - 40 KVA/32 K W @ 0.8PF d) System of Voltage - 3 phase, 415 V, e) Frequency - 50 Hz f) Insulation - Class F/H The Alternator should confirm to IS 4722. Operation and service manual, spares and tools shall be provided. 7. Fuel Tank Suitable size built in type integrated with the acoustic enclosure Fuel connection shall be done as per standards 8. Battery Suitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per Manufactures requirement. Automatic Battery charger Solid state phase indication lamp for supply ON/OFF with HRC protection. standard conrol panel as per kerala Electrical Inspectorate requirements, with 63A 4 pole MCB and accessaries such as Multi function metre and seperate Energy metre etc.Complete.
od205109/2018_2019 : Supply, conveyance, Installation, testing & commissioning of 62.5 KVA Diesel Generator set with integral acoustic enclosure as per CPCB norms with srandared acessories as per technical details given below. 1. Engine : a) Make of Engine - Kirloskar//Cummins/Leyland b) Type of Engine - Diesel Engine c) No. of Cylinders - As per manufactures standards. d) Method of Cooling - Water cooled with radiator. e) Design - Suitable for generating set operation 2.Standard accessories with Diesel Engine a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fan provided with fan guard. e) Fuel Pump f) Fuel filter g) Lubricating oil filter h) Exhaust silencer i) Exhaust Muffler j) Battery Charger/Generator 3. Engine Instrument Panel with the following items a) Starting switch with key or button b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter e) Battery charging Ammeter 4. Safety Controls for Engine a) Trip for low lubricating oil pressure b) Trip for high water temperature. 6. Brushless Alternator a) Make - Kirloskar/KEL//Stanford/LS b) Type - Self exited and self regulated. c) Capacity - 40 KVA/32 K W @ 0.8PF d) System of Voltage - 3 phase, 415 V, e) Frequency - 50 Hz f) Insulation - Class F/H The Alternator should confirm to IS 4722. Operation and service manual, spares and tools shall be provided. 7. Fuel Tank Suitable size built in type integrated with the acoustic enclosure Fuel connection shall be done as per standards 8. Battery Suitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per Manufactures requirement. Automatic Battery charger Solid state phase indication lamp for supply ON/OFF with HRC protection. standard conrol panel as per kerala Electrical Inspectorate requirements, with 63A 4 pole MCB and accessaries such as Multi function metre and seperate Energy metre etc.Complete.
od170658/2018_2019 : Supplying and fixing of exhaust pipe of 150 mm sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends, tees etc . adequately supported on rigid supports duly painted with heat resistant paint as per specification and as required complete in all respect.
od170660/2018_2019 : Supplying and fixing of exhaust pipe of 80 mm sizes of MS 'C' class along with necessary clamps, vibration ,isolators and fittings such as bends, tees etc . adequately supported on rigid supports duly painted with heat resistant paint as per specification and as required complete in all respect. -
od170662/2018_2019 : Supplying, and fixing, 65 mm thick resin bonded fiber glass wool /rock wool having density of 48kg/m3 fixed on DG Exhaust Muffler of DG set for the thermal insulation and each layer covered by a layer of chicken mesh and finally applying 0.63 mm aluminium sheet cladding complete as per specifications and as required .
od170664/2018_2019 : EXHAUST PIPE ( 150 MM )CLADDING: Supplying, and fixing, 65 mm thick resin bonded fiber glass wool having density of 48kg/m3 fixed on 150 mm pipe section for the thermal insulation and totally covered with a layer of chicken mesh and finally applying 0.63 mm aluminium sheet cladding complete as per specifications and as required on the existing MS pipe of DG exhaust.
od170668/2018_2019 : EXHAUST PIPE ( 80 MM )CLADDING: Supplying, and fixing, 65 mm thick resin bonded fiber glass wool having density of 48kg/m3 fixed on 80 mm pipe section for the thermal insulation and totally covered with a layer of chicken mesh and finally applying 0.63 mm aluminium sheet cladding complete as per specifications and as required on the existing MS pipe of DG exhaust.
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
od171346/2018_2019 : Charges for conducting load test of 62.5 KVA DG set at standardized Factory bed as per standard norms and condition. ie in various steps load up to full load for 3 hours & 10% over load for 20 minutes and the rate includes hire and rent of test bed equipment's, labour charges ,loading and unloading and fuel etc.The test certificate should be given the client in standard format.
od171348/2018_2019 : Charges for conducting load test of 250 KVA DG set at standardized Factory bed as per standard norms and condition. ie in various steps load up to full load for 3 hours & 10% over load for 20 minutes and the rate includes hire and rent of test bed equipment's, labour charges ,loading and unloading and fuel etc.The test certificate should be given the client in standard format.
Panel Fabrication
90.14.1.1 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.2.2 : Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.4 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 40 x 3mm heavy duty flat neoprene gasket in the panel board
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5 : Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7 : Supply and providing copper earth bus in the panel board
od205709/2018_2019 : Copying charges of Electrical/fire Drawing per A3 sheet additional copies
od205711/2018_2019 : Charges for preparation of Electrical/fire Drawing per A3 sheet first copy
CABLE /TRAY/PIPE/GLAND
90.12.1.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 50 sq mm
90.12.1.30 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 70 sq mm
90.12.1.34 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 185 sq mm
90.12.1.1 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 4 sq mm
90.12.1.2 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 6 sq mm
90.12.1.12 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 4 sq mm
90.12.1.13 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm
90.12.1.39 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 6 sq mm
90.12.5.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm
90.12.5.30 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 70 sq mm
90.12.5.34 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm
90.12.7.1 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp
90.12.7.2 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
90.12.7.16 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 25 sq mm with factory made clamp
90.12.7.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
90.12.7.12 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp
90.12.7.13 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp
90.12.7.15 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 16 sq mm with factory made clamp
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
90.12.7.34 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
90.12.7.36 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm
90.12.41.35 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.41.7 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp
90.12.41.32 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
od201692/2018_2019 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 11 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments
od201694/2018_2019 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 11 KV grade of the following sizes in the existing masonry open duct as required. 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments
od201696/2018_2019 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 11KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
9.1.9 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 25 sq. mm (25mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
14.15.1 : Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)
14.15.2 : Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal)
14.15.3 : Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal)
4.1.1 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.1.2 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.1.4 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.1.6 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness
4.1.7 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness
Contator /Meter/Indications/Relay/CT
od171060/2018_2019 : Supply and fixing of 9 A, 3 pole POWER CONTACTOR (For 5.5 HP motor), AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INCs etc as required.
od171076/2018_2019 : Supply and fixing of 25 A, 3 pole POWER CONTACTOR (For 15 HP motor), AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC and giving connections etc as required.
od171078/2018_2019 : Supply and fixing of 12 A, 3 pole POWER CONTACTOR (For 7.5 HP motor), AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC and giving connections etc as required.
od171080/2018_2019 : Supply and fixing of 40 A, 3 pole POWER CONTACTOR (For 25 HP motor), AC3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC and giving connections etc as required.
od171082/2018_2019 : Supply and fixing of 18 A, 3 pole POWER CONT ACTOR (For 10 HP motor), AC3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC and giving connections etc as required.
od171136/2018_2019 : Supply and fixing of 65 A, 3 pole POWER CONTACTOR (For 50 HP motor), AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC and giving connections etc as required.
od160413/2018_2019 : Supply and fixing 240/360/415V ON/Off delay Electronic timer suitable for motor starter ( L& T or equivalent make)
od159917/2018_2019 : Supply and fixing of Multi function meter to read: V, A, F, 3 phase accuracy class 1 LED
od164043/2018_2019 : Supply and fixing of Three Phase Ammeter accuracy class 1 and giving connection.
od165387/2018_2019 : Supply and fixing of Three Phase Voltmeter accuracy class 1 and giving connection.
od171142/2018_2019 : Supply & fixing HT TOD meter,3 phase, 4 wire, 110V(L-L), for 1A / 5A CT with out CT (Accuracy class 0.2s)
od171150/2018_2019 : Supply and Fixing of POWER CONTACTOR AC-1 rating , 160A , 4 Pole, 415 A, 50 HZ with 2No, NO/NC auxiliary contactors, mechanical interlock etc and fixing in the exising cubicle with all accessories and giving connection as required(L&T or its equivalent).
od171152/2018_2019 : Supply and fixing of Single phase preventer relay and giving connection etc (L& T or ts Equivalent make)
od160409/2018_2019 : Supply and Fixing of Flush head Push Button with 1 NO Block
od160411/2018_2019 : Supply and fixing of Flush head Push Button with 1 NC Block
od165312/2018_2019 : Supply and Fixing of Rotary switch 1P 2 way 6A Auto /Manul and giving connection etc as required.
od165314/2018_2019 : Supply and fixing of SP MCB below 1 to 4A 10KA 'C' Curve and giving connection as required.
od159921/2018_2019 : Supply and Fixing of Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia
od159923/2018_2019 : Supply and Fixing of Blue colour LED indicator, AC/DC, 22.5 mm cut out dia
od166558/2018_2019 : Supply and Fixing of Illuminated Flush head Actuator - Red with legend 'OFF', (Contact - 1 NC)
od166560/2018_2019 : Supply and Fixing of Illuminated Flush head Actuator - Green with legend 'ON', (Contact - 1 NO)
od172374/2018_2019 : Supply and fixing following rating Surge Protection Devices (3P+N) ,Conforms to IEC 61643-11, Type 1+2(Protection against direct and indirect lightning surges) , Maximum Discharge Current - Imax up to 100 kA in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (L&T or Equivalent Make)
od165268/2018_2019 : Supply and Fixing of PLA Relay 24V 5A 8/11 pin with base and Giving connection etc as required
od171364/2018_2019 : Supply and installation, testing and commissioning of AMF Relay and giving connections as required
od159925/2018_2019 : Supply and Fixing of 100/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT
od167992/2018_2019 : Supply and Fixing of 500/5 A, 15 VA, accuracy class 1, Resin Cast Metering CT
od164265/2018_2019 : Supply and Fixing of 400/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT
od164261/2018_2019 : Supply and Fixing of 200/5 A, 10 VA, accuracy class 1, Resin Cast Metering CT
od167996/2018_2019 : Supply and fixing of 70/5 A, 5 VA, accuracy class 10P 5, Protection CT (Tape wound)
od167998/2018_2019 : Supply and Fixing of 100/5 A, 10 VA, accuracy class 10P 5, Protection CT (Tape wound)
od166336/2018_2019 : EMERGENCY PUSH BUTTON:- Supply Installation, Testing and Commissioning of Manual Call Points of break glass type with hammer and chainM if required.
od166338/2018_2019 : Supply and Fixing of Mushroom headed Spring return/pull type ON -OFF switch 16A and giving connection as required
od166340/2018_2019 : Supply and Fixing of Bakelite Fuse Base 20A with HRC Fuse Link 2A and giving connection as required
od166692/2018_2019 : Supply & fixing the 32A, 2 Way neutral links mounted on DMC/SMC base
od166580/2018_2019 : Supply and fixing of 32 A HRC Fuse base with HRC link and 32 A 2 Way neutral link in the existing single phase metering cubicle etc as required
od166342/2018_2019 : Supply and Fixing of DC Ammeter Digital CL 0.5 0 to 30A and giving connection as required
od159941/2018_2019 : Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 2.50 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
od159943/2018_2019 : Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 1.50 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
od159945/2018_2019 : Supply, laying and clamping of 1 no. 2.5 sqmm 8 core PVC/ XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE with the cables, spacing of clamps with factory made clamp not exceeding 60cms, making good the damages , colour washing etc. as required.
od159947/2018_2019 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed 2.5 sqmm 2 core PVC / XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE , spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
od164163/2018_2019 : Supply and wiring with single core copper conductor cables 4 sq mm single run with required sockets.650/1100 V grade PVC insulated stranded conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment including providing suitable size sockets at the termination points, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
od165274/2018_2019 : Supply and wiring with single core copper conductor cables 6 sq mm single run with required sockets.650/1100 V grade PVC insulated stranded conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment including providing suitable size sockets at the termination points, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
od167422/2018_2019 : Supply and wiring copper conductor cables 16 sq mm single run with required sockets.650/1100 V grade PVC insulated stranded conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment including providing suitable size sockets at the termination points, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
od165276/2018_2019 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor control cable of 650V grade as required. 2 X 1.5/2.5sq. mm (16/19mm)
od165278/2018_2019 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor control cable of 650V grade as required. 8 X 1.5/2.5sq. mm (22/25mm)
od164213/2018_2019 : Supply and Fixing of Auto - Manual, 40 x 25 mm with 15 m hole aluminium anodised legend plates
od164215/2018_2019 : Supply and Fixing of Earth, 40 x 20 mm with 8 mm hole aluminium anodised legend plates
od164217/2018_2019 : Supply and Fixing of Cable alley, 100 x 40 mm aluminium anodised legend plates.
od164219/2018_2019 : Supply and fixing of Bus bar chamber, 100 x 40 mm aluminium anodised legend plates
od164221/2018_2019 : Supply and Fixing of Danger 415 V, 150 x 100 mm aluminium anodised legend plates
od164223/2018_2019 : Supply and Fixing of Danger 415 V, 200 x 150 mm aluminium anodised legend plates
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
EARTHING
od159836/2018_2019 : Supply and providing plate earthing with 1200x1200x12 mm GI/CI earth plate as per IS 3043, 50mm GI watering pipe, GI funnel with weld mesh, 25 x 3mm GI clamps, charcoal etc., including providing brick work masonry enclosure at the top (450 x 450 x 450 mm inside) and CI/MS cover plate hinged to FRL Same with Locking arrangement but excluding earth continuity conductor, test joint etc
od171190/2018_2019 : Supply and clamping the 32 x 3 mm sizes of COPPER STRIP tinned at the points of contacts and fixed on surface of wall/ parapet/ existing cable tray using factory made clamp , not exceeding 1m, making good the damages, colour washing etc. as required
od171192/2018_2019 : Supply and clamping the 25 x 3 mm sizes of COPPER STRIP tinned at the points of contacts and fixed on surface of wall/ parapet/ existing cable tray using factory made clamp , not exceeding 1m, making good the damages, colour washing etc. as required
od171296/2018_2019 : Providing and fixing 25 mm X 3 mm size COPPER STRIP tinned at the points of contacts , laying in the existing trench or along with the cable including connection/ Jointing with brass nut, bolt, spring, washer etc . as required.
od171298/2018_2019 : Providing and fixing 32mm X 3 mm size COPPER STRIP tinned at the points of contacts , laying in the existing trench or along with the cable including connection/ Jointing with brass nut, bolt, spring, washer etc . as required.
od164233/2018_2019 : supply of superior quality copper earth socket for 3.14mm (10SWG) of earth conductor including crimping etc. as required.
od167220/2018_2019 : 12SWG Bare copper conductor
od167222/2018_2019 : 14SWG bare copper conductor
od164235/2018_2019 : 10SWG bare copper condutor
od166272/2018_2019 : Supply and Laying of 8 SWG bare copper conductor
od164237/2018_2019 : Supply and Laying of 6 SWG Bare copper conductor and giving connection as required.
od167270/2018_2019 : Supply and Laying of 4SWG Bare copper conductor
od167280/2018_2019 : supply of superior quality copper earth socket for 2.00mm (14SWG) of earth conductor including crimping etc. as required.
od167282/2018_2019 : supply of superior quality copper earth socket for 2.65mm (12SWG) of earth conductor including crimping etc. as required.
od167284/2018_2019 : supply of superior quality copper earth socket for 3.14mm (10SWG) of earth conductor including crimping etc. as required.
od167286/2018_2019 : supply of superior quality copper earth socket for 4mm (8SWG) of earth conductor including crimping etc. as required.
od167288/2018_2019 : supply of superior quality copper earth socket for 4.75mm (6SWG) of earth conductor including crimping etc. as required.
od167290/2018_2019 : supply of superior quality copper earth socket for 6mm ( 4SWG) of earth conductor including crimping etc. as required.
od167393/2018_2019 : Supply and providing 25x3mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
od167416/2018_2019 : Supply and providing 25x6mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Miscellaneous /Civil
od160010/2018_2019 : Supply and providing 2.5mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength including fixing with suitable synthetic adhesive,
od172023/2018_2019 : Supply and providing 6mm MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for the cable trench covering.
od160012/2018_2019 : Supply and providing 2mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength including painting in ground with suitable synthetic adhesive.
od172035/2018_2019 : Fabrication, supply, conveyance and fixing frame work made out of suitable size angle iron/ flat cut and welded to shape of suitable size painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes to mount the switch gears/Cabel/machines for support , fixed to wall/floor using suitable size anchor bolts etc grouted to wall, making good the damages, colour washing etc as required
od165690/2018_2019 : Supply of Electrical safety hand Glows 2.9mm minimum thickness,withstanding 26 KV protection made by Natural Latex, off white colour ( Certification shall be attached) .
14.1 : Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9 : Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.10 : Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
od171991/2018_2019 : STEEL REINFORCEMENT- Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
14.11 : Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
14.12 : Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
od160016/2018_2019 : Supply and providing 6 Kg. ABC Fire Extinguisher with hose and clamps including fixing it to wall as required.
od160018/2018_2019 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. as per IS 2546
od160020/2018_2019 : Painting letters or figures of the 2.50 cm, 4 cm or 5 cm height sizes with enamel paint as identification mark to SB, DB, panel board etc as required
Bidder Name
KERALA ELECTRICAL AND ALLIED ENGG CO LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.12 MB
form83and84CE.pdf
Tender Documents • 0.95 MB
biddocumentslaughterH.pdf
Tender Documents • 1.95 MB
BOQ_446260.xls
BOQ • 0.69 MB
PRELIMINARYAGREEMENT.pdf
Tender Documents • 0.10 MB
DECLARATION.pdf
Tender Documents • 0.19 MB
epaymentform.pdf
Tender Documents • 0.05 MB
Download all tender documents and submit your bid