Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC | ₹2.9 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹3.0 Cr+₹7.0 L (2.41%)Rejected-Finance | ₹3.0 Cr+₹7.0 L (2.41%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹3.0 Cr+₹8.1 L (2.79%)Rejected-Finance | ₹3.0 Cr+₹8.1 L (2.79%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹3.1 Cr+₹21.7 L (7.50%)Rejected-Finance | ₹3.1 Cr+₹21.7 L (7.50%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹3.1 Cr+₹24.0 L (8.32%)Rejected-Finance | ₹3.1 Cr+₹24.0 L (8.32%) | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹3 Cr
EMD Value
₹3.8 L
Closing Date
27 Jul 2022, 6:00 pmClosed
CHIEF ENGINEER COAST GUARD VISAKHAPATNAM
CHIEF ENGINEER COAST GUARD VISAKHAPATNAM-530007
PROVISION OF GIRLS HOSTEL AND ALLIED INFRASTRUCTURE FOR CADETS IN KORUKONDA
2022_MES_519487_2
CE (CG) /VIZ/KORU/TOKEN 05 OF 2022-23
Open Tender
Civil Works
Lump-sum
365 days
KORUKONDA
As per tender documents
8 documents required · 8 mandatory
₹2,000
AGE I CG Vizag
₹3.8 L
Yes
10 Aug 2022
28 Jun 2022
29 Jul 2022
28 Jun 2022
27 Jul 2022
7 Jul 2022
Amount
Schedule "A" Part – I to Schedule "A" Part – XIV: NOTE: Schedule "A" Part – I to Part – XII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lump Sum price worked out by the contractor for "BUILDINGS & STRUCTURES", for the lumpsum price of Rs. 1,80,68,000.00 inserted by MES as listed in Schedule 'A' Part - I on Serial Page No. 32
Price worked out by the contractor for "EARTH WORK, SITE CLEARANCE AND AREA DEVELOPMENT ", against the price of Rs. 6,56,419.21 inserted by MES as listed in Schedule 'A' Part - II on Serial Page No. 33
Price worked out by the contractor for "INTERNAL WATER SUPPLY", against the price of Rs. 93,201.44 inserted by MES as listed in Schedule 'A' Part - III on Serial Page No. 35
Price worked out by the contractor for "INTERNAL ELECTRIC SUPPLY", against the price of Rs. 2,25,404.21 inserted by MES as listed in Schedule 'A' Part - IV on Serial Page No. 37
Price worked out by the contractor for "EXTERNAL WATER SUPPLY", against the price of Rs. 90,680.22 inserted by MES as listed in Schedule 'A' Part - V on Serial Page No. 38
Price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY", against the price of Rs. 1,99,201.00 inserted by MES as listed in Schedule 'A' Part - VI on Serial Page No. 39
Price worked out by the contractor for "SEWAGE DISPOSAL", against the price of Rs. 2,54,596.33 inserted by MES as listed in Schedule 'A' Part - VII on Serial Page No. 41
Price worked out by the contractor for "AREA DRAINAGE", against the price of Rs. 13,36,446.08 inserted by MES as listed in Schedule 'A' Part - VIII on Serial Page No. 43
Price worked out by the contractor for "ROAD/PATH/HARDSTANDING/CULVERT WORK", against the price of Rs. 22,44,302.14 inserted by MES as listed in Schedule 'A' Part - IX on Serial Page No. 46
Price worked out by the contractor for "LIGHTENING PROTECTION WORK", against the price of Rs. 33,952.00 inserted by MES as listed in Schedule 'A' Part - X on Serial Page No. 47
Price worked out by the contractor for "SOLAR HEATING AND HOT WATER SUPPLY", against the price of Rs. 35,479.20 inserted by MES as listed in Schedule 'A' Part - XI on Serial Page No. 48
Price worked out by the contractor for "RAIN WATER HARVESTING AND RECHARGE PIT", against the price of Rs. 4,08,416.88 inserted by MES as listed in Schedule 'A' Part - XII on Serial Page No. 51
Schedule "A" Part - XIII [ARBORICULTURE]
Item No 1 :Supply and filling with general planting soil mix (Topsoil) to areas defined as soft cape comprising of Red earth (including fertilizers such as neemcake, cocopeat, DAP, termite control etc.), FYM and compost in the ratio 3:1:1 (3 parts sweet earth: 1 parts FYM: 1parts compost) as indicated in technical specifications, placed over the free draining sub-soil, flood with water till saturation, filling more earth as necessary after settlement, watering and finally fine dressing, leveling etc complete all as directed.
Item No 2 :Supplying and laying Neelgiri/Mexican grass/Korean grass turf with earth 50 mm to 60mm thickness of existing ground prepared with tools wooden (Dhurmos) and then rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and naintenance for 30 days or more till the grass establish properly, complete all as directed.
Item No 3 :Supply, plantation and developing of Foxtail Palm plant [height of plant not less than 2 metre above ground level and of age 30 Days] with proportional girth (25cm to 35 cm) , evergreen and shaddy species including preparation of ground upto 600mm deep and of size 600 X 600mm and filling of good earth [3 Parts], Cow dung and Vermi-Compost [1 Part] and watering etc. complete all as directed.
Item No 4 : Supply and planting of Day queen jasmine of height, spread and growth as per specifications, for planting (low hedge 50cm to boundary of planter) in 20cm container size and >30cm height, plants must be healthy showing multiple branches with consistent signs of growth and free from disease. Apply a slow release fertilizer at time of planting complete all as directed.
Schedule "A" Part - XIV [Miscellaneous Items]
INTERNAL ELECTRIFICATION
Item No 5 : M & L for concealed point wiring on wall/floor/ ceiling etc with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC-FRLS insulated unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing after cutting the chases and making good the surface all as specified and directed by Engineer-in-Charge for the following :-
(a) One light point/security light/ceiling/exhaust/wall mounted fan controlled by one switch
(b) One 3 pin socket outlet , 5 Amps on an independent board controlled by one switch .
(c) One 3 pin socket outlet , 5 Amps on same board controlled by one switch .
(d) One light point controlled by two switches single pole two way
Item No 6 : M & L for concealed point wiring on wall/floor/ ceiling etc with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 4.0 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC-FRLS insulated unsheathed copper multi-stranded conductor of size 2.5 Sqmm, 1100 volts grade for continuous earthing after cutting the chases and making good the surface all as specified and directed by Engineer-in-Charge.
Item No 7 : M&L for 1 X 20 watt LED ceiling/wall mounted lighting fixture with Lamp Lumen not less than 2100 lumen polycarbonate body ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed. MAKE :- Cat-Part No. BN021CLED20S-PSUCWGRS2 of PHILIPS or equivalent as approved by AGE(I) as per makes given in the list of makes.
Item No 8 : M&L for 1 X 8/10 watt LED ceiling/wall mounted lighting fixture with Lamp polycarbonate body ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed. MAKE :-Cat-Part No. BN021CLED10S-6500-SUCWGRS1 of PHILIPS or equivalent as approved by AGE(I) as per makes given in the list of makes.
Item No 9 : M&L for 1 X 35 watt decorative ultra slim square profile liner LED lighting fixture with Lamp polycarbonate body ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed. MAKE :- Cat-Part No. SM251CLED35S-6500PSUWH of PHILIPS or equivalent as approved by AGE(I) as per makes given in the list of makes.
Item No 10 : S&F LED Security light fitting with driver of 1X40W, with HF electronic driver pre wired with 1.5 Sqmm copper conductor cable upto connector suitable for 40mm dia pole of GI tubing Med grade bend to shape fixing on wall with suitable MS brackets and clamps complete all as specified and as directed. MAKE :- Cat-Part No. BRP409LED40CWHOMRFGPSUGR of PHILIPS or equivalent as approved by AGE(I) as per makes given in the list of makes.
Item No 11 : S& F LED bulb 9 Watt pin type system lumen not less than 770 Lumen complete all as specified and directed.
Item No 12 : S& F ceiling fans AC single phase 230 V of size 1200mm sweep with complete set with fixtures. BEE 5 star rating, metallic body including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose/point wiring to ceiling fan complete all as specified and directed.
Item No 13 : S& F Modular Fan step regulator, 120W - 2 module complete all as specified and as directed.
Item No 14 : M&L for exhaust fan metallic body with louver, heavy duty 300mm sweep 900 RPM with 230 V including connecting up with three core twisted flexible copper conductor cable of suitable size complete.
Item No 15 : MCB single pole neutral (SPN), 32-40 amps, 240 volts, 10 KA, 'C' curve with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed. Note:(i) Cost of copper lugs shall be included in the unit rate.
Item No 16 : MCB single pole (SP), 6-10 amps, 240 volts, 10 KA, 'B' curve with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed. Note:(i) Cost of copper lugs shall be included in the unit rate.
Item No 17 : Sub main wiring with 02 runs of 4.0 sqmm and 01 run of 4.0 sqmm , FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, ISI Marked, drawing through and including concealed PVC rigid conduit not less than 20mm dia. complete with necessary fittings such as junction boxes couplings, unions bends reducers, inspection elbows, plugs, sealing conduits etc complete all as specified and directed . ( Note: 3 runs of 4.0 Sqmm cable with one run of conduit will be measured as one unit i.e RM). [INCLUDING 180 RM FOR HOT WATER SUPPLY] Note (i): Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii)Three runs of cable and one run of conduit with necessary accessories will be measured as one unit length. (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
INTERNAL WATER SUPPLY
Item No 18 : S& F Angle Stop valves, 15mm bore, cast copper alloy, screwed down, high pressure, chromium plated screwed for iron pipe or for unions and fixed complete all as specified and directed.
Item No 19 : S& F two way bib cock 15mm bore with flung cast copper alloy chromium plated fancy type screwed for iron pipes brass ferrule etc complete all as specified and directed.
Item No 20 : S& F Brass wall mixer 15 mm bore dia for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
HOT WATER SUPPLY
Item No 21 : S& F of Geyser 25 Ltrs capacity vertical type 25 KW 230 Volts 50 Hz , 02 KW heating element, 5 star rated including fixing arrangement by providing holding tank, nut bolt and connecting up electric cable and water supply connection alongwith 02 Nos 16mm UPVC connecting pipes, stop valve, HOT water 15mm pipe and COLD water 15mm pipe with CP nuts and bolts, bib taps CP fancy type 15mm, connecting wires and 3pin plugtops, complete all as specified and directed.
Item No 22 : BLANK
COOLING APPLIANCES
Item No 23 : Supply,Connecting & Install storage water cooler water cooling, electric driven having approx storage capacity of 80 Ltrs & nominal cooling capacity of 40 Ltrs per hour 5/4 star complete all as specified and directed. Make : Blue star/Voltas/Daikin
Item No 24 : Supply and fix Voltage stabilizer for automatic operation ,single phase naturally air cooled indoor type & designed for input variation between 170V to270V and output voltage stabilized between 215V to 240V with accuracy of +/-2.5% and of capacity 1 KVA (for water coolers and refrigerators) complete all as directed and specified. Make : Blue Bird/ V Guard/Capri
ROAD/ PATH/ CULVERT/HARD STANDING
Item No 25 : S & F Solar Road Studs [Bi-Directional] made of Aluminium Die cast matt finish of size 125 X 125 X 25mm [Approximately], working on High Efficiency Mono-Crystalline Solar Panel 2.4 V / 0.3 Watt, One Ni-Mh or NI-cd Rechargeable Battery [1.2V / 1600 MA] with Six Super Bright LEDs with 10,000 to 18,000 mcd [Millicandela], with a minimum Operating time of 3-4 consecutive days with full charge, viewing distance / visibility not less than 800m with 2 Hz Flash Rate, Self operated from Dusk to Dawn, anti twist ribs on the bottom anchor / shank with high intensity reflective grade polymer sticker and conforming to IS - 12063, of Colour yellow or red or blue or green or white as approved by GE complete all as specified and as directed.
Item No 26 : S & F Road Stud, Two way reflective of size 100mm X 110mm X 20 mm [Approximately], ABS body with retro reflective panel of Amber, Red or White colour complete all as specified and as directed.
Item No 27 : M&L including preparation of new/old road surfaces and applying road marking paint 2 to 2.5mm thickness (white), bead not exceeding 10 cm/15cm with retro-reflective hot thermoplastic road marking paint conforming to BS 3262:Part-I 1989 with 20% glass width (Inter mixed) spread & laid by automatic mechanical machine Engine drive as in centre line, side line road marking of 150/100 mm width using HOT MARK by indigenous modern propelled road marking machine as directed including ingredients such as blinders, glass bends titanium dioxide calcium carbonate inter filler, thermoplastic requirments foer glass bends shall be the table no.800.4 of MOST specifications including spraying of glass etc all as manufacture's instructions complete all as specified and directed.
Item No 28 : S & F Poly Carbonate Convex Mirror outdoor type 800mm dia made out of fibre along with bracket, Pole mounted and fixed to 80mm bore Medium Grade MS Pipe of required length complete and embedded in PCC 1:3:6, Type C1, including necessary earth work required for post holes complete all as specified.
Item No 29 : BLANK
SEWAGE DISPOSAL
Item No 30 : 150 mm dia double wall corrugated pipe (SN4) laid in trenches and jointed incl coupler with rubber rings complete all as directed. Make: ASTRAL
EXTERNAL ELECTRIFICATION
Item No 31 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 3.5 core, 35 sqmm cross-sectional area, complete all as specified and as directed.
Item No 32 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 2 core, 6 sqmm cross-sectional area, complete all as specified and as directed.
Item No 33 : Supply ,fixing, testing and connecting LED Security light fittings 65 Watts , IP-65 cast aluminium housing in grey hammer tone stove enamelled finish outside with electric connection of Electronic driver and LED panel with suitable size of copper cable with base plate and complete all as specified and as directed. Make - Philips Cat Part No. BRP062 LED 65CW SLA S1 PSU or equivalent in Havells/ Crompton Greaves
Item No 34 : S&F bracket made of medium grade GI tubing bracket of size 40 mm dia, 1.2 Mtr long , bend in 120 degree for mounting of street light fittings with MS clamp, nuts and bolt complete all as directed by Engr-in-charge.
Item No 35 : Supply and fix Polycarbonate cable looping box of size 130 x 130 x 77 mm With connector block 4 Way , including provision for copper shorting strips etc including suitable stainless steel gland, including provision for connecting earth continuity conductor etc. all as specified and directed. Make :Hensel Cat No DK 0600 G or equivalent as approved by AGE(I).
Item No 36 : Supply and fixing post top lantern LED type 20 watt 230 volts AC out door type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lampo complete with driver and lamp complete all as specified and directed.
SOLAR WATER HEATER
Item No 37 : Design,supply, installation,testing and commissioning of Roof TOP solar photo voltaic power plant 15KWp on Girls Hostel and allied Infrastructure for Girl Cadets in Sainik School Korukonda Visakhapatnam with power evacuation at 415V, 3 Phase 4 Wire system including connected civil works such as foundation, structural frame work etc. complete all as per guidelines / norms issued by MNRE & Indian Meteorological Deptt viz solar radiation data, direct normal irradiance, global horizontal irradiance etc complete in all respect comprising the following:- (A) SOLAR PHOTO VOLTAIC MODULES: Each solar PV modules shall be poly crystalline type, of wattage minimum 335 Wp. The module efficiency shall be more than 16.99% at standard test conditions. Modules will be with anti reflective coating and anti dust coating. These will confirm to IEC 61215-Edition II ,IEC-61730 (Part I & II) and IEC-61701 and all other applicable IEC/IS standards. Note:(i) Solar module and SPV cells used in the module will essentially be indigeneously manufactured in India (ii). PV modules shall be warrented for minimum 25years (iii) PV modules must be warranted for their output peak watt capacity not less than 90 % at the end of 10 years and not less than 80% at the end of 25 years. (iv) PV module shall be tested by any MNRE approved laboratory. (Solar PV modules- Maximum - 45 Nos) Make :TATA/PANASONIC/EMMVEE/ADANI/VIKRAM SOLAR /RENEWSYS
(B) RFID : Each PV module must use a RF identification tag mandatorily placed inside the module laminate, which must contain the following information :- (i) Name of the manufacturer of PV Module (ii) Name of the Manufacturer of Solar cells (iii) Month and year of the manufacture(separately for solar cells and module) (iv) Country of origin (separately for solar cells and module) (v) I-V curve for the module (vi) Peak Wattage, Im, Vm and FF for the module (vii) Unique Serial No and Model No of the module (viii) Date and year of obtaining IEC PV module qualification certificate (ix) Name of the test lab issuing IEC certificate (x) Other relevant information on traceability of module as per ISO 9000 series.
(C) Solar PV module GI frame work and Dead Weight : Modular mounting structure(MMS), fabricated from pre coated mild Steel / hot dipped Galvanized Iron section of suitable size with oppropriate & optimum tilt angle according to site requirment to achieve maximum benefit of solar energy and suitable to withstand total 200 KM/Hr wind speed with sufficient quantum of Dead Load Fly Ash/PCC Brick/Block of total weight of Minimum 2700 Kg as per Structural deign data complete all as specifed and as directed. Note:- (a). Module mounting structure may require to be customized with respect to the site availability. (b)The contractor shall submit structural design on Stad- Pro based on Wind load of 200 kmph on the surface of the panel, live load and dead load of structure with solar panel & seismic zone of Chennai. Any deflection to the mounting structure shall be as per IS 800:2007 (c) Minimum thickness of galvanization should be at least 600 gsm. Test certificate of galvanization shall be submitted by contractor. (d) The structure will not be grouted on the roof and roof will not be damaged in any way during the installation, Any unintended damage done to water proofing/roof structure during installation shall be made good by the contractor at no extra cost as directed by GE.
(D) Inter connection of Solar PV modules, Connection from Solar PV Modules to DC Control Box and Connection from DC Control Box to Inverter : DC cable single core 6 sqmm copper, XLPE insulated, flexible conductor cable conforming to relevant IS code, weather proof, UV resistant, rated voltage 1100V grade including suitable type of copper lugs, suitable required qty of male & female MC4 connectors (M-10, F-10) & joints etc including Aluminim raceway for cable all complete as specifed and directed. MAKES: POLYCAB, FINOLEX,HAVELLS
(E) DC Control Box - 01 Nos .Supply, fix, laying and testing of DC control box/junction box, with mounting holes, Mounting Screws of required qty, suitable for 15 KWp plant ,weather proof (IP - 65) suitable for outdoor duty with and including suitable rating of MCB breakers, string fuses with base ,copper bus bar, voltage grade 1100V etc for combining solar PV module output complete all as specifed and as directed. MAKE : LEGRAND/L&T/SIEMENS/SCHNEIDER/HAVELLS
(F) String Grid Invertor - 01 Nos: Grid tied Solar string Invertor unit suitable for SOLAR PV plant of capacity 15KWp (DC to AC 415 volt at given load condition, Three phase system), wall mounted, with efficiency not less than 97% conforming to IEC 61673 , IEC 62109 and equivalent IS standards with multifunctional LED indications with alarm LED/LCD digital display system with following specification complete :- (i) Nominal voltage: 415V, +/- 5% 3 phase 50Hz (ii) Microprocessor / DSP micro controller system (iii) IP65 (outdoor) Protection enclosure (iv) Grid frequency synchronization +/- 2% range (v) No load losses<1% of rated power (vi) Ambient temperature 4°C to 60°C. (v) Conforms to IEC 62116 for Anti Islanding protection. (vi) Internal protection features againt any fault in feeder line and lightening fault in feeder. (vii)Protection features- Inverter should have following protections (a) Anti islanding (b) Over voltage protection (c) Over current protection (d) Over temperature protection (e) Reverse polarity Protection (f) Surge protection (g) Short Circuit (g) Frequency change (viii) MPP Trackers (ix) No. of Inputs: minimum 6 (x) Total Harmonic Distortion < 3%. (xi) Power Factor >90%. (xii) Inverter should be capable of synchronisation with grid supply and DG set supply. (xiii) Should have necessary support for Online Remote Monitoring System (RMS) Data logging system complete in-built with inverter (RJ45 port).
(xiv) Cable RS 485 for Monitoring device complete all as specified. Make of cable :- LAPP/DIGILINK/TOP/LEONE/SMA (xv) Cable CAT 6- Cable of suitable lenghth for Monitoring device complete all as specified. Make of RMS :- LAPP/DIGILINK/TOP/LEONE/SMA Make of cable :- LAPP/DIGILINK/TOP/LEONE Make of Invertor :- DELTA/SMA/SCHNEIDER/ABB/POWERONE/SURYALOGIX
(G) A data logging system for plant shall be provided to measure the following data through web based application with cloud storage :- (i) Solar irradiance : Solar Irradiance an integrating sensor (Pyranometer) mounted in the plane of the array. Read out should be integrated with data logging system (ii) Wind speed: Wind Speed:An integrated wind speed measurement unit be provided. (iii) Amb temperature and Module surface temp : Temperature Sensor : Integrated temp, sensors for measuring the ambient temp and module surface temp and to be provided complete with read outs integrated with the data logging system. (iv) Module surface temp (v) Total output Voltage & Current. (vi) Generation data KWh (per inverter and cumulative) (vii) Instantaneous generation in KW (Each invertor and cummulative) Note: Facility of Remote Monitoring to be installed on existing PC at Principal office and mobile app facility to be provided with 05 years of Web Charges included.
(H) Connection from Invertor to AC control box : Supply and laying 4core 10sqmm 1100V grade copper flexible cable required qty as per site requirment complete all as specifed. MAKE: POLYCAB, HAVELLS, FINOLEX. (J) AC Control Box - 01 Nos :- Supply, fix and testing of AC control box, Weather proof (IP65), suitable for outdoor duty. Enclosure with mounting holes, Multifunctional Meter, 415V rating copper Bus bar- 3 Phase, Mounting Screws, AC Surge Protection Device -01 No. (SPD Class 2 as per IEC 60364-5-53, Input 5KV) MCCB 4P 100 A, 415V, 36 KA- 01 No.,ON/OFF indication lamps , connections ,lugs or glands etc complete all as specifed and as directed. MAKE OF MCCB: LEGRAND/L&T/SIEMENS/SCHNEIDER/HAVELLS (K) GI strip Earthing connection: Supply and Laying/fixing of GI earth flat strip of size 25x3mm of required length with FRP saddles & fixing screws as per site requirment for connection to earthing grid with Four no.s down conductors from roof, complete all as specifed and as directed.
(L) Solar panel earth wire connection: Supply, laying & testing required qty as per site requirment of single core 6 sqmm copper conductor cable conforming to relevant IS weather proof, rated voltage 1100V grade with and including suitable type of copper lugs, all as specifed and as directed to connect all the PV modules structurees to earthing grid of GI 25x3 mm. MAKE: POLYCAB/HAVELLS/FINOLEX (M) Earth wire connection of DC control box, Invertor & AC control box & : Supply, laying & testing of required qty as per site requirment of single core 6 sqmm copper conductor cable conforming to relevant IS weather proof, rated voltage 1100V grade with including suitable type of copper lugs for earth wire connection of DC control box, Invertor & AC control box MAKE: POLYCAB/HAVELLS/FINOLEX (N) Protection Pipe for single core 6 sqmm copper cable [Inter connection of Solar PV modules, connection from Solar PV Modules to DC Control Box and Connection from DC Control Box to Inverter (Item 1.04) , Solar panel earth wire connection (Item L), Earth wire connection of DC control box, Invertor & AC control box (Item (M)] : M&L High density polyethylene pipes (HDPE) of min 20 mm dia and pressure rating 6 kgf/cm2 required qty as per site requirment for protection of copper cables as said above, laid / fixed on wall with necessary GI support, complete all as specifed and directed.
(O) MCCB enclosure: Floor/Wall mounted vermin proof, MCCB enclosure with suitable capacity MCCB with space for mounting at least 2 meters . Fabricated out of CRCA sheet not less than 3.15 mm thick. (P) M&L for civil works required for SPV panel supports , control box, invertor fixing etc complete all as specifed and directed. NOTES:- (i) The contractor will have 5 year Defect Liabillity period after completion of the work. During the DLP of 05 years the contractor will ensure generation of Minimum Average units (4 Units/KW/Day). Contractor rep and GE rep will make a joint inspection of plant on monthly basis and monthly summary of plant production will be jointly signed. (ii) The rate quoted by the tenderer is deemed to be inclusive of Registration fees and commissioning charges to State Electricity supplying agency Including to take licence of Chief Electrical Inspectorate of SEB and CEA (Central regulatory authority) including all other connected misc charges i.e APEPDCL for obtaining no objection certificate for commissioning 15KW solar power plant at Sainik School Korukonda Visakhapatnam., if any. (ALL costs of SEB & CEA Registrations and approvals are deemed to be included in the contract rates)
(iii) Qualifying Criterion : The Bidder should have the following experience;- (a) Successfully completed Installation , Testing and commissioning of cumulative capacity of 100 KW solar plant. (b) Certificates of Client satisfaction. (c) Bidder should have valid registration as Electrical Contractor. (iv) The contractor shall carry out Shadow Analysis at the site and accordingly design strings & arrays layout considering optimal usage of space, material and labour. The contractor should submit the array layout drawings along with Shadow Analysis Report to AGE(I) for approval. (v) Drawings : The Contractor shall furnish the following details for approval prior to the commencement of the work :- (a) General arrangement and dimensioned layout. (b) Schematic drawing of the plant showing the SV panels, Power conditioning inverter, Junction Boxes, AC and DC Distribution Boards, meters etc. (c) Structural drawing of the mounting structure. (d) Layout of solar Power Arrays and strings (e) Shadow analysis of the roof
(vi) On completion of project contractor shall provide Two sets of following : (a) Structural drawings. (b) Electrical drawings. (c) O&M manuals of each equipment showing complete technical data sheet including deatils of specifications and makes. (d) Details of synchronization equipment and protection equipment. (vii) Design of solar power plant to be vetted by NISE or independent agency approved by MNRE. (viii) Display Board: The contractor to put up a display board of suitable size and type of material at the project site mentioning the following: Plant Name, Capacity, Location, Date of commissioning, Warranty details, CA no., MES Office, Power generation, Name of the contractor, Contact number for Maintenanace, etc. (ix) Test Reports / Certificates of PV Modules, Solar cells and Invertor to be submitted by the contractor.
Item No 65 : Supply and laying of 4 Core 10 sqmm XLPE insulated armoured heavy duty 1100 V grade UG cable with multistranded aluminium conductor in trenches/wall/pipe/floor with suitable cable glands,aluminium lugs etc complete all as specified with Modifications of existing LT Panel for connection complete for input from Solar PV plant all as specified and directed by Engineer in charge.
EXTERNAL WATER SUPPLY
Item No 38 : Construction of Valve Chamber of size 450 X 450 X 600 mm internal size suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 5 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as directed.
EARTHINGS
Item No 39 : Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
Item No 40 : Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
EARTH WORK
Item No 41 : Supply only Moorum/red bajri, good earth (from outside MoD land) and bringing to the site filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering. complete all as specified. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
M/s.Raghava Enterprises
P Govinda Reddy Infrastructure
Ruchira Associates
CIVILEC ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .