Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-AOC | ₹3.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹3.4 LRejected-AOC | ₹3.4 L | L2 | Rejected-AOC L2 |
Tender Value
₹3.4 L
EMD Value
₹8,390
Closing Date
16 Feb 2026, 6:00 pmClosed
AEE
PWD Electrical Sub Division Tvpm
GENERAL-Govt Secretariat Tvpm-Renovation works for the Office of the Deputy Secretary,Scheduled Castes, Scheduled Tribes and Backward Classes Department in Room no 395, first floor, Main building-Electrical-General Electrical W
2026_PWD_835333_1
ESDT/ET-252/2025-26
Open Tender
Electrical Works
90 days
PWD Electrical Sub Division Tvpm
please refer tender documents
6 documents required · 6 mandatory
₹740
₹8,390
25 Jun 2026
10 Feb 2026
18 Feb 2026
10 Feb 2026
16 Feb 2026
10 Feb 2026
Part-1- Electrification
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
90.3.8:Supplying and providing extra steel chain (16 SWG) 4 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
OD167541/2025-2026:SITC 600 lumen round/ square(1X1) recessed fitting made of diecast aluminium body, polycarbonate diffuser, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea
OD167495/2025-2026:Supply, conveyance, installation, testing and commissioning of philips recessed corner (make Philips or tehcno commercial equivalent ).
OD167496/2025-2026:Supply, conveyance, installation, testing and commissioning of philips recessed Trimless 1m track (make Philips or tehcno commercial equivalent )
OD167497/2025-2026:Supply, conveyance, installation, testing and commissioning of philips recessed Trimless 2m track (make Philips or tehcno commercial equivalent )
OD167498/2025-2026:Supply, conveyance, installation, testing and commissioning of L connection (model no.582028) (make Philips or tehcno commercial equivalent )
OD167499/2025-2026:Supply, conveyance, installation, testing and commissioning of 1.5 meter connection kit for spot blade track light (make Philips /tehcno equivalent ).
OD167500/2025-2026:Supply, conveyance, installation, testing and commissioning of 18Wspot blade track light , efficiency not less than 110 l/w, pf greater than 0.95, THD less than or equal to 10%, properly placed in the table and giving connections etc. as required (make Philips /tehcno equivalent ).
OD167501/2025-2026:Supply, conveyance, installation, testing and commissioning of 100W driver for spot blade track light (make Philips /tehcno equivalent ).
OD165784/2025-2026:Supply, conveyance, installation, testing and commissioning of pre-wired 3600 lumen square (2ft X 2ft) recessed fitting made of CRCA sheet of thickness 0.5mm, having efficiency not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, (Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) suspended from ceiling properly hooked to steel hooks anchored to the ceiling and giving connections etc. as required.
OD165781/2025-2026:Supply and fixing 12W LED recess mounted 50mm aluminium extruded linear lighting luminaires with superior white powder coated finish. fixture having efficiency not less than 110 Lumens/w light output, pf greater than 0.95, THD less than or equal to 10%, length 60cm, mounted in ceiling and giving connection etc if required. (Philips-Pureline slim recessed/equivalent)
OD165775/2025-2026:Supply and fixing 1800 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, (Chip make: Cree/Osram/lumilled/Nichea) fixed in fall ceiling including cutting holes and giving connection etc if required.
OD165779/2025-2026:Supply and fixingrecessed mounted 36 degree adjustable 7W, 630lm LED spot light/ wall washer fitting white colour including cutting hole in the ceiling as required. Focus can be adjustable asper requirements.
OD165782/2025-2026:Supply and fixing -10 Watts LED Bulk head fitting with IK09 impact resistance, IP66 metal body fixed in to the existing wall or ceiling including giving connections with the required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire confirming to relevant IS/extending the original wiring and making good the surfaces as required.(Make: Philips/Equivalent)
OD165783/2025-2026:Supply, Conveyance, Installation, Testing and Commissioning of surface mounted 10W integrated LED bath room mirror lamp fitting including fixing ,making good the damages etc as required (Philips or equivalent make )
OD165774/2025-2026:Supply and fixing 10 Watts LED metal body Picture lamp fixed in wall and giving connection etc as required.
1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
19.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
OD165772/2025-2026:Supply and fixing metal body wall mounting fan of the following sizes using mounting brackets supplied along with the fan and giving connection etc. as required..- 450 mm sweep metal frame Wall Mounting fan
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
OD165776/2025-2026:Supply and fixing 20 mm dia PVC flexible conduit with accessories on surface of wall making good the damages etc as required.
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.14:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.9.2.2:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider
90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
90.9.2.4:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
90.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer
90.9.2.24:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat Tee
90.9.2.12:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box
90.9.2.13:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.4 to 5 module mounting box
90.9.2.14:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.8 module mounting box
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
OD165773/2025-2026:Charges for dismantling the tube lights, ceiling fans, wall fans and conveyance to section store.
OD165778/2025-2026:Charges for dismantling the PVC conduits with copper wire, network cables, telephone cables etc. and conveyance to section store.
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1405540.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1405540.xls
BOQ • 0.39 MB
viewsbd.pdf
Additional Documents • 3.72 MB
specialconditionsmodified.pdf
Other Document • 0.15 MB
mom1MAIN.pdf
Other Document • 0.73 MB
Download all tender documents and submit your bid