Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹30.9 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹44.8 L+₹12.3 L (37.6%)Rejected-AOC | L-2 | Rejected-AOC L-2 | |
| 3 | l-3₹48.4 L+₹15.8 L (48.6%)Rejected-AOC | l-3 | Rejected-AOC L-3 |
Tender Value
₹45.9 L
EMD Value
₹91,900
Closing Date
29 Feb 2024, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
CLEANING/REPAIR OF SEWAGE LINE AND DRAIN, PATHWAY AND OTHER MISC WORK AT RESIDENTIAL KWC AREA, PETTY REPAIR TO B/R NATURE WORKS JOINERY, PLUMBING WORK, ROOF TREATMENT ETC IN VARIOUS KWC LABS AND REPAIR/MAINT OF LT PANELS, LT UG CABLES AND CERTAIN ALL
2024_MES_638059_1
GE/RND-89/DLI/2023-2024
Open Tender
Civil Works
Item Rate
240 days
DELHI
Class-D, Cat-a(i), b(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹91,900
Yes
27 Mar 2024
18 Jan 2024
2 Mar 2024
18 Jan 2024
29 Feb 2024
10 Feb 2024
Amount
Cleaning & clearing manholes by taking off manhole covers and re-fixing the same after cleaning of any description, underground any depth by removing any type of blockage including de-silting and de-chocking and flushing after cleaning, clearing of manholes. Sludge/ sludge water shall be disposed off in closed container at authorized dumping site declared by local administration outside MoD land as directed by Engineer-in-Charge, upto 150mm dia sewage lines complete all as specified and directed.
Removal of blockage in between two manholes spacing upto 18 meters of underground sewage line of any type and size upto 200 mm dia by means of mechanical rodding with vibrations/drilling concept. A trolley mounted motorized sewer cleaning machine for the execution of item shall have to be provided by the contractor. Blocked material, slugging obtained during execution of this item shall be removed from the site through trolly mounted motor out of defence land. Sewage line between existing two manholes shall be flushed with combined high pressure water jetting cum suction (vaccum type machine suitably mounted on HCV having facilities of hydraulic applications with suitable size of nozzle pipes. Item shall be executed by the contractor upto satisfaction of the Engineer-in-Charge. No extra claim, whatsoever shall be entertained at any stage. Quoted rate shall be deemed to include complete all as specified and directed.
Desilting of septic tank any size including cleaning and taking out mud/ sludge, scum, silt (both organic and inorganic nature) from septic tanks by mechanical means of any depth, in foul conditions and confined places, getting out and removing the Sludge / Sludge water disposed off in closed container at authorized dumping site declared by local administration outside MD land complete all as specified and directed. Note:- Net contents of sludge shall be measured at the time of removal and paid. Quoted rate of tenderer is deemed to be inclusive of dewatering as required and nothing extra shall be admissible to the contractor on this account.
Maintenance of sewage system SGSW/PVC(SWR)/NP2 pipe including Nahani / floor traps, Soil / waste pipe running on external wall of building and in trenches with fittings, bends, junctions etc, Gully traps, manholes of all description and sewage lines of all sizes upto soak well/Municipal drain of sewage system complete in perfect running / flowing order without destruction by removing all blockage in the system including cleaning the floor trap, gully trap,IWC,EWC Wash basin, Urinal pots,bottle trap, in kitchen, lobby, bath room, toilets at any height of floor (Maximum G+7 Floor) including pipe line up to the first manhole including maintaining of drain (Bricks / PCC) in running condition by removing all surplus spoil in entire KWC residntial area (inside and outside area of all KWC area) under GE (I) R&D delhi, complete all as specified. Notes:- (i) Contractor shall deploy minimum 2 safaiwala solely for the maintenance of sewage system against this item alongwith necessary tools and will be required to report AGE B/R office KWC area to collect the complaint slip from concrened JE on normal working hours from 0900 hrs to 1700 hrs on all working days but on demand for Sundays, Holidays, additional working hours also, contractor shall provide the same to meet the requirements. These Safaiwala / Mazdoor shall not be deployed for any works other than the scope catered for in this item. For the work considered against other items of this Schedule the contractor shall deploy separate safaiwala / mazdoor in addition to the safaiwala /mazdoor deployed against this item. (ii) Rate also includes for necesary tools and plants which is required for execution of item i.e cleaning rod, buckets, bamboos sticks, Kashi etc (iii) Sludge slurry / sludge water shall be disposed off in closed container at authorized dumping site declared by local administration outside MD land. (iv) Solid waste / sludge / silt deposited in the manholes which can not be removed by rodding, shall be ordered under respective item of this schedule and paid accordingly.
Desilting and cleaning of open drains of any section manually including desilting soild/semi solid materials of any type vegetation growth and removal of sludge upto a distance exc 5.00 KM but n exc 10 KM from the edges of drains etc complete all as specified and directed.
Clearning of roofs i.e. removal of vegetables, roots, removal of blockage from mouth of rain water pipes and rubbish off from premises, brooming etc. up to height of (G+7) storey buildings complete all as specified and directed.
Cutting of bushes not exc 10cm girth and removing of unserviceable material to a distance not exc 50 m and cleaning site complete all as specified.
Excavation as in trenches in any type of soil not exceeding 1.5 metres wide and not exceeding 1.5 metres in depth and getting out complete all as specified and directed.
Returning, filling in any type of soil including spreading, levelling, watering and well ramming in layers n.exc. 25 cm complete all as specified and directed.
Removing excavated material/Malba to a distance exceeding 1.5 KM and not exceeding 20 KM depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
M&L Salt glazed stoneware drain pipe Grade 'A' 150 mm bore laid in trenches and jointed including taking down existing pipe complete all as specified and directed.
M&L Salt glazed stoneware drain pipe Grade 'A' 200 mm bore laid in trenches and jointed including taking down existing pipe complete all as specified and directed.
M&L in replacement 300mm Reinforced concrete pipes, class NP2, laid and jointed with collars complete all as specified and directed.
M&L for PVC (SWR) 150mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including demolition and breaking up existing unserviceable PVC pipe and removal of debris complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in bed drain pipes of 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested including demolition of existing concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in bed drain pipes of 200 mm bore including packing under and haunching against the sides of pipes after they are laid and tested including demolition of existing concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in bed drain pipes of 300 mm bore including packing under and haunching against the sides of pipes after they are laid and tested including demolition of existing concrete complete all as specified and directed.
S&F 75 mm internal dia PVC (SWR) pipes single socketed in any length with rubber led joint, laid in trenches including dismantling old unserviceable pipe complete all as specified and directed.
S&F 110mm internal dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to wall (upto a height of G+7) with MS clamps including taking down old unserviceable pipes complete all as specified and directed.
S&F 75 mm internal dia PVC (SWR) pipes single socketed in any length with rubber ring joint, fixed to wall (upto a height of G+7) with MS clamps including taking down old unserviceable pipes complete all as specified and directed.
S&F PVC (SWR) bends any radius 110 mm dia complete all as specified and directed.
S&F 75mm dia PVC (SWR) bends with rubber ring joints fixed as required complete all as specified.
S&F PVC (SWR) bends any radius 110 mm dia with oval access door including taking down old unserviceable complete all as specified and directed.
S&F in repair PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) floor trap/nahani trap, plain with grating including jointing with solvent cement and taking down old trap and necessary concrete work complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and as directed.
S&F in repair cast iron sand cast soil waste and vent pipes in any length with or without ear with cement joint 100 mm bore laid in trenches or in floor complete all as specified and directed.
S&F in repair cast iron sand cast soil waste and vent pipes in any length with or without ear with cement joint 100 mm bore fixed to walls complete all as specified and directed.
S&F in repair CI bend diminishing pieces or taper 100 mm bore complete all as specified and directed.
S&F in repair CI branch pieces 100 mm dia single (equal or unequal) ordinary or inverted or with parrallel branch complete all as specified and directed.
S&F in replacement wash hand basins, white colour,vitreous china,of size 550x400mm (flat back, or angle back type) including cutting for and pinning in ends of brackets or erecting stand inclusive of waste pipe,waste coupling etc complete all as specified and directed.
S&F in repair Vitreous China wash down water closet pan EWC (pedestal pattern), white colour (excluding fixing bolts, flushing cistern & flush pipe)incl Plastic water closet seat, white, closed pattern with flat bottom, & cover & mild steel CP or aluminised hinging device complete all as specified and directed
Supply and fixing as in repair vitreous china squatting pan "Orissa" pattern size 580 x 440mm, white, with integral footrest (excluding flushing cistern) including connection to trap,and to flushing pipe, anti-syphonage pipe,etc. complete including making good to floor, set with cement concrete, fixed as in repairs complete all as specified and directed.
S&F in repairs Viterious China urinals, bowl type(back or corner wall type) ofsize 465X355X265 mm,complete including providing and fixing plugs,bedding urinal against wall in Cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws,pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe,grating and Union for discharge pipe complete all as specified and directed.
S&F in repair sensor kit assembly with infrared sensor for detecting movement and battery capable of automatic flushing of water in urinal suitable for sensor type urinal pot of required size for proper functioning complete all as specified and directed.
S&F in repairs vitreous china Urinal, Half stall type white (excludign flushing cistern, flush pipe and waste pipe) including connections to flushing pipe and outgoing pipes fixed in repairs complete all as specified and directed.
S&F in repair urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimun weight 60 gms) complete all as specified and directed.
S & F in repairs10 ltrs capacity PVC flushing cistern, low or high level, with inlet, ball valve, syphonic action type, float and handle, PVC Flush pipe , pull or push type including brackets complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for water proofing treatment to sunken slab complete all as specified and as directed in the following operations:- (a) Clean the surface with mechanical grinding for remove the dust ,debris and oil deposits, remove all the loose material, like cement slurry, mortar, plaster and other unwanted particles clean the surface with soft brush to make it clean and dust free. (b) Providing and laying of a 75x75mm coping with polymer modified mortar at floor wall joints wherever necessary. (c) Providing and applying one coat of Asian paint smart care repair polymer or equivalent in Pidilite/fosroc/sika mixed with cement in ratio of 1:2 over the entire clean and prepared surface as a sealer coat. (d) Supplying and applying two component of asian paints smart care ultra block 2k or equivalent in pidilite/fosroc/sika acrylic polymer modified high performance coating system, brush applied, membrane with an elongation of >220% and tensile strength of 1.72MPa as per ASTM D 2370:2016,crack bridging ability of 3mm as per EN 1062-7:2004,no leakage upto a 5 bars of water pressure. The system includes final base preparation, applying the coating in two coats with a total consumption of 2.25kg/sqm.(e) providing and laying 25mm thick cement sand plaster admixed with integral water proofing compound @200ml per bag of cement(1cement:4sand) flollwed by neat cement punning. Note: Water pounding test shall be carried out for 48 hrs.
M&L PCC 1:2:4 type B 0 (using 12.5 mm graded stone aggregate) 25 mm thick mixed with WPC as in bedding in sunken portions etc complete all as specified and directed.
M&L Plain cement concrete 1:5:10 mix, type E-2 (using 40mm graded stone aggregate) as in filling of sunken portion complete all as specified and directed.
S&F in repairs 40mm dia GI Tubing as in spout pipe of medium grade including cutting in any length as required and fixed to wall & floor etc complete all as specified and directed.
S&F repair GI tubing 15mm bore medium grade with all fittings & fixed complete to walls /ceiling or laid in floors complete all as specified and directed.
S&F In repair 20 mm dia GI steel tubing medium grade galvanised with all fittingsand fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Cutting chases, pining in making good to facings where required & pointing in cement mortar1:3 to ends etc or edges of landings, steps cills,sunshades, shelves,lintels,etc and cutting chases for concealed water tubing and making good,cutting n.exc. 10cm girth in brick walls all asdirected.
Demolition of brick work or stone/ boulder masonary built in cement mortar including all quoins arches, pillers etc but excluding ashler facings dressed stone work and precast concrete articles complete all as specified and as directed.
M&L for brick work straight or curved on plan exc 6m mean radius in cement mortar (1:6) with Sub class ‘B’ brick including manhole raising, footpath, etc complete all as specified and directed.
All as per item No. 48.00 above here-in-before but except bricks complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in benching for manholes and haunching around manholes frame for setting, , holdfast fixing etc including use of necessary form work and finishing exposed surfaces even and smooth using extra cement complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) as in surface channels and drains,coping incl finshing of exposed surfaces even & smooth with using extra cement complete all as specified and directed
Taking down cement plaster, pointing, on brick or stone/concrete walls, drain surfaces etc including racking out joints, hacking for key, scrubing down with water etc in any position (upto a height of G+7 storey) complete all as specified and directed.
M&L for 15 mm thick Rendering plaster on brick work or concrete surfaces in CM (1:4) mixed with WPC as per manufactures instructions finished even and fair without using extra cement (upto a height of G+7 storey) complete all as specified and directed.
Supply only Liquid Water proofing compound PIDIPROOF LW+ of Dr FIXIT or equivalent as approved complete all as specified and directed
M&L rendering 15 mm thick plaster in CM (1:6) on brick walls or concrete surface, finished even and fair without using extra cement complete all as specified and directed.
M&L rendering 15 mm thick plaster in CM (1:4) on brick walls or concrete surface, finished even and fair without using extra cement complete all as specified and directed.
Preparation of newly plastered outer wall surfaces and applying two coats of cement base paint. complete all as specified and directed.
Preparation of newly plastered inner wall surfaces and applying two coats of OBD over 1mm thick wall care putty complete all as specified and directed.
S&F in repair vertical veniation blind consisting of alum head rail, vanes/louvers 4” wide of approved tint and traverse cord complete fixed in position all as spd, complete all as specified and directed.
Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for PCC type B1 1:2:4 (using 20mm graded agg) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelersm apexstone, bed plates, including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for 75mm thick cement concrete type D-2,1:4:8 (40mm graded stone aggregate) as in sub base concrete all as specified & directed.
Material and labour for Precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slabs of manholes, gully traps etc set in cement mortar (1:4) complete all as specified and directed.
M&L for PCC 50 mm thick (1:4:8), type D2 (using 40 mm graded mechanically crushed stone aggregate) as in sub base of floor complete all as specified and directed.
M&L for Prepainted Chequered cement concrete tiles 30cmx30cmx22 to 25mm thick, set, jointed and pointed in neat cement slurry in floors using with grey cement and pigment, over 20mm thick rendering in CM 1:6 and cement concrete coping type B-0 1:2:4 using 12.50 graded store aggregate on all sides as edging all as specified.
M&L for PCC (1:4:8), type D2 (using 40 mm graded mechanically crushed stone aggregate) as in foundation, filling, mass concrete and sub base of floor complete all as specified and directed.
Demolition of reinforced cement concrete as in RCC slabs, beams, etc drains or manhole covers of any description and in any position not otherwise specifically provided for complete all as specified and directed.
S&F Factory made precast heavy duty drain/ manhole covers including MS frame and including reinforcement as per IS 12592 : 2002 with specified thickness complete all as specified and directed.
M&L for Precast RCC work (Nominal Mix) (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in slabs supported on walls, man hole cover ,drain covers ,Shelves etc and like complete all as specified and directed.
M&L for TMT bars of 10mm dia and over, cut to lenght bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortor bedding (but not backing), removing rubbish off the premises complete all as specified and as directed.
M & L non skid coloured tiles 400mm X 400mm X 7mm thick as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick cement screeding in CM (1:6) complete all as specified and directed.
M&L glazed ceramic tiles 300x450x7to8mm thick coloured tiles in vertical surfaces etc set and jointed in neat cement slurry and pointed in white or colour cement to match as in dado over 15mm thick cement plaster in CM (1:4) complete all as specified and directed.
M&L for light shade coloured vitrified light shade tiles (600x600mm size) 8 to 9mm thick (Sqm/ rectangular) polished, in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20mm thick cement screed bed in CM (1:6) complete all as specified and directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exc. 0.11 Sqm but n.exc 0.18 Sqm in floor set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles laid over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L glazed ceramic tiles 300x200x7mm thick coloured tiles in vertical surfaces skriting dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile over 10mm thick cement plaster in CM (1:4) complete all as specified and directed.
Supply and fixing factory made chequered cement concrete coloured tiles 200mm x 200mm x 25mm thick, set jointed and pointed in neat cement slurry with grey cement mixed with pigment to match the colour of tiles, laid over and including 20mm thick screed bed in CM 1:4 and PCC 1:2:4 type B-0 (12.50 mm stone aggregate on all sides as edging, complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Supply & fixing framed work conforming to FE-290 Gde E-165 as in door, grill railing, cattle trap/drain covers on open drains using mild steel angle iron, MS flats of sizes as directed with and including provision of MS hings and MS Hold fast fixed complete all as specified and directed.
M&L for preparation of newly steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F grating doom of size 100/125/140 mm CP in round or square shape for out let of water etc complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar,or laid dry complete all as specified and directed.
M&L for Granite 16 to 18 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking plateforms and like in cemen mortor (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. Including 20mm thick screed bed or bedding lay in CM 1:6 complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over 20mm thick screed bed or bedding layer in CM 1:6. complete all as specified and directed.
M & L for machine made Rubber moulded precast concrete interlocking paver block (coloured),pre polished of any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness M-35 Grade, laid over and including 25mm average thickness sand cushioning complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from water tanks, capacity exceeding 250 litre but not exceeding 500 litre and from mouths of circulating pipes etc. by emptying, drying, cleaning by scrubbing the dust with wire brush from tank by removing inlet and outlet pipe and refixing inlet and outlet pipe with new tank connection fitting in the same position after cleaning complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from water tanks, capacity exceeding 500 litre but not exceeding 1000 litre and from mouths of circulating pipes etc. by emptying, drying, cleaning by scrubbing the dust with wire brush from tank by removing inlet and outlet pipe and refixing inlet and outlet pipe with new tank connection fitting in the same position after cleaning complete all as specified and directed.
S&F in repair 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod &high density plastic ball screwed for iron pipe and fixed for 20 mm bore pipe, complete all as specified and directed.
S&F as in repairs Plastic water closet seat cover, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F as in repairs PVC internal syphone kit with handle suitable for low level flushing cistern having10 ltrs capacity, white, valveless, syphonic action type complete all as specified.
S&F in repairs flush pipe/L bend for PVC low level flushing cistern as suitable for EWC/ Orissa pattern pan including jointing to WC complete all as specified and directed.
S&F as in repairs soap dish chromium plated of size 100 x 100 mm any type, fixed with chromium plated brass screws complete all as specified.
Supply and fixing 15mm dia PVC connection with brass nut, of length 450mm,fixed as in repairs, complete all as specified and directed.
S&F as in repair 15mm bore pillar tap long/Swan neck,cast copper alloy, with capstan heads, chromium plated, screwed down high pressure,with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and directed.
S&F in repair long body Bib taps,chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, suitable for pipe, fixed as in repair complete all as specified and directed.
S&F in repair 15 mm bore angle stop valve, chromium plated,screwed down, high pressure with crutch or butterfly handle screwed for iron pipe or for union, suitable for pipe, fixed as in repair complete all as specified and directed.
S&F in repair 15 mm dia stop valve concealed type cast copper alloy screwed down high pressure chromium plated with long shank including dismantling porting of the wall as required including making good to match with existing complete all as specified and directed.
S&F in repair in 15mm dia ball valve high pressure of PTMT complete with aluminum rod with polyplast ball complete all as specified and directed.
S&F as in repair Chromium plated shower rose 125 mm size fixed with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed.
S&F in repair Toilet paper holder with flat recessed type stainless steel box type fixed to wall,with chromium plated brass screws, complete all as specified & directed.
S&F as in repairs 100 mm dia mild steel chromium plated grating complete all as specified and directed.
S&F as in repairs chromium plated waste coupling fitting 100mm / 75mm bore pipes to kitchen sinks complete all as specified and directed.
S & F as in repair 32mm dia CP waste coupling, for WHB, with long screwed shanks and fly nuts, flange and based in red lead cement complete all as specified and directed.
S & F as in repair 40mm dia CP waste coupling, for WHB, with long screwed shanks and fly nuts, flange and based in red lead cement and complete all as specified and directed.
S&F in repair PVC lid for water tanks of 500/1000 Ltr capacity screwed type with locking arrangments complete all as specified and directed.
S/F in repair PVC waste pipe 32mm/40mm dia 60 CM long fixed complete all as specified and directed.
Removing building materials etc.to a distance of upto 20 km, outside defence land beyond the lead, including loading, unloading and stacking at the destination complete all as specified and directed.
Taking down and Adjusting / repairing of Aluminium door/windows shutters, for easy closing/opening tightning of hinges or changing the position of hinges, tighetning of Glass/ Particle board by replacing rubber beading and clip packing, adjustments of floor machine for smooth opening and closing and refixing the same complete all as specified and directed.
Taking down and refixing of PVC door shutter (after taking down) loosened at joints of styles, by let in for making good and where hinges etc have been removed/loosened from chowkhets or frames and easing etc for complete functional complete all as specified and directed.
S&F in repair door closer hydraulically regulated, aluminium body designation No 3, universal type, suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stailess steel cover, governing pivot made of brass, other parts made of mild steel heavy duty fixed complete complete all as specified and directed.
Dismantling AC sheet/CGI sheet/PGI Sheet/tensile fabric sheet (corrugated, semi corrugated, etc) in roof covering complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Repairing of rolling shutter push type with necessary repair work of defective parts i.e, re posting of laths, riveting to old defective rivets, tightning nuts and bolts, replacement of spring, greasing to movable parts and at guide channel, greasing the sides of the rolling shutter, including taking out and re-fixing rolling shutter for smooth functioning size of rolling shutter n.exc 25 sqm each all as directed.
Taking down and Adjusting / repairing of steel window shutters for smooth opening/closing including greasing, welding and adjustment of projecting type friction hinges in any position make fully functioning complete all as specified and directed.
Supply & fixing as in repair aluminium alloy body floor door stopper of size 75m having double round legs for better grip ,with rubber base fixed to door shutters with countersunk screws complete all as specified and directed.
S&F in repairs 250 mm long aluminum alloy anodised sliding door bolt hasp staple (bolt type) and fixed clips of sheet cast or extruded section fixing bolts and sliding bolts of extruded section complete all as specified and directed.
M&L securing glass of any description in existing steel frame with putty including removing of old putty complete all as specified and directed.
S&F in repairs extruded aluminium alloy handles, fabricated type, anodised 150 mm size complete all as specified and directed.
S&F in repairs 200 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F in repair 100 mm hinges MS Butt hinges medium weight cold rolled. complete all as specified and directed.
S&F in repair 75 mm hinges MS Butt hinges medium weight cold rolled. complete all as specified and directed.
S&F in repair 100 mm long aluminium handles, cast type anodied for alluminum windows complete all as specified and directed.
S&F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staple etc in wooden/steel frames complete all as specified and directed.
S&F in repair 4 mm thick sheet glass in squares/rectangle in each pane fixed with wooden beads or putty (in metal/wooden frames etc) complete all as specified and directed.
S&F in repair 5.5mm thick sheet glass of any colour, ordinary quality and glazing with snap beading and gasket, neoprene packing etc. for aluminium door & window exc 0.5 Sqm in each pane. complete all as specified and directed.
S&F in repair 500 litres capacity rotational moulded polythene water storage tank triple layered (Cylindrical vertical with closed top ) hoisted and fixed in position 500 ltrs capacity including disonnecting and refixing the GI pipe and fittings complete all as specified and directed.
All as per Srl Item No 128.00 above but 1000 ltrs capacity of tank. complete all as specified and directed.
M&L two coats of synthetic enamel paint over a coat of zinc chrome/red oxide primer including preparation of old steel surfaces over 10 cm in width or girth complete all as specifeid and directed
S&F in repair dead lock, verticle type of brass complete size 100mm and 4 levers complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutters from the frame) of size exc 1.5 sqm but not exc 4 sqm and making good to distrubed surface without any extra cost complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not exc 1.5sqm and making good to distrubed surface without any extra cost complete all as specified and directed.
S & F pressed steel frames for doors with one or more rebates of size 105x60 mm including necessary fixing lugs, lock strike plate etc complete made out of 1.25 mm thick MS sheet all as spd and directed.
S&F pressed steel frames for doors of size 125 x 60 mm for doors with one or more rebate incl necessary fixing lugs, hinges, lock, strike plates welded with frame and making arrangement for fixing of door spring etc complete all as specified.
S&F in repair mortice lock with both side handle set, verticle type of brass with cylindrical lock of suitable size compmlete all as specified and directed.
S&F factory made solid PVC door frame size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube as per spacification and directed.
PCC 1:3:6 type C1 using 20mm graded stone aggregate as in filling hollow of pressed steel frame.
S & F factory made solid pannel PVC door shutter 30mm the style consisting of frame made out of MS tube, for top & bottom rail, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, bottom rail & lock rail on either side & as gep insert for top rail and bottom rail. panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement as per spacification and directed.
S&F 30mm thick flush shutter solid core construction with block board core and ply wood face panels commercial type on both sides all as spd and directed.
Material & Labour prepapration of new or previously untreated surfaces of wood or based materials of any description not otherwise described, over 10cm width or girth & applying two coats of synthetic enamel paint coat complete all as spd and as directed.
S&F 100mm size butt hinges, medium weight cold rolled mild steel all as spd and directed
S&F 150 mm long aluminum anodized barrel tower bolt of extruded section all as spd and directed
S&F 150mm size aluminum handles cast type, anodized all as spd and directed
S&F 250mm long aluminum alloy anodized sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminum alloy all as spd and directed
S&F 50 micron thick podwer coated aluminium grill 6x 45mm thick section 10cm center to center spacing complete with U-channel all around fixed in windows with screws complete all as per specified and as directed.
S&F anodised aluminium powder coating aluminium section weighing not less than 0.55Kg/m (minimum thickness of powder coating 50 micron)frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified
S&F anodised aluminium Powder coating door shutters aluminium section weighing not less than 0.55Kg/m {minimum thickness of powder coating 50 micron) including necessary joining cleats, glazing clips, ruber neoprene packing , hinges,anodised aluminium snap beading screws,all necessary builders hardware etc complete all as specified.
S&F anodised aluminium Powder coating window and ventilator shutters, side hung type without sash bars aluminium section weighing not less tha 0.55Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150mm long (1no), hinges type B-21 100mm long(2 no.) suitable handle(1 no) including all necessary builders hardare complete all as specified.
S&F 12mm thick particle board exterior grade with decorative prelaminated both sides of approved shades fixed to aluminium shutters/ partitions complete all as specified and directed.
S&F 4.8mm thick sheet glass ordinary quality in Squre/rectangle exc 0.5 sqm each pane coloured and fixed with glazing pins and rubber beading etc in alum door/partion etc complete all as specified and directed.
S&F in repair aluminium anodised fully glazed partly panelled partitions and fixed glazing made out of anodized alum section 63.50x 38.10 x 1.60mm including necessary jointing cleats glazing clips, rubber packing anodised alum snap beading screws etc, frame work fixed to walls , floor and ceiling with rawl plug wherever required complete all as spd and as directed by Engineer-in-Charge (Sheet glass and particle board shall be measured and paid for separately) Note : area of each panel shall not be exc 01 sqm
S&F in repair Stainless steel sink, 1.00mm thick for kitchen or laboratory with plug waste pipe, washers including cantilever cast iron brackets connecting union etc. overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Dismantling boarding, any description, fixed in any positioin with nails complete all as specified
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking GI metal grid of hot dipped galvanized steel sections consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture having 8 to 10 mm thick square edge PVC Laminated Gypsum board Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed.
M&L for decorative wall panelling with WPC louvered/Fluted/Plain 2D/3D wall panels with plastic and silicate mixture as the core material with inand surface with PVC foil on the top with thickness of panel 10mm to 20mm, width of 150mm to 200mm and length of 2.74/3.05 (9' or 10') meters of POLYWOOD or equivalent brand Wt of PVC pannel is 4.5 kg/sqm and PVC percentage in wall panels is more than 40% including necessary L/H/U corner profile and fillets. WPC Wall panel are termite proof , water proof and usable on the damp walls, fixed to wall/ ceiling surface as per manufacturer instruction complete all as specified and directed by Engr-in-charge.
M&L for decorative solid Wooden Flooring classic series having HDF (high density fiberboard) wood Plank rectangular shape with interlocking pannels with plastic and silicate mixture as the core material with Plank size 1215 x 195 x 8 mm kiln dried and finished with UV coating for durable finish of approved wooden texture and shade over and including laying of necessary form/fiber on floor fixed as per manufacturer instruction complete all as specifed and directed by Engr-in-charge.
S&F L/H/U profile and corner profile molding with fillet at top ,bottom and corner to hold the wooden flooring and wall panelling with exactly the same shade as that of the flooring planks as per manufracturer instruction complete all as specified and directed.
S&F in repair double rolling type vertical venetian blinds with decorative designs and color consisting of Aluminium head rail with flip cover of approved tint/shade and traverse coard complete as per manufacturer instruction fixed in position complete all as specified and directed.
Complete removal of existing roof treatment of brick tiles/ brick cowa including Mud phuska in up to depth of original roof slab and removing entire rbbish off the premises, and applying Water proofing treatmnet as under:-(i) Applying bitumen primer @ 0.30 ltr/Sqm (ii) Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per Sqm including cleaning surfaces. (iii) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified.The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (iv) Machine pressed plain cement concrete tiles 25cm x 25 cm x 22 mm thick, set and jointed in neat cement slurry in floor, roofs cut and polished with grey cement and no pigment and pointed in cement to match the shade of tile over 20 mm thick screed bed or bedding layer in cement mortar 1:3 Note : (i) The cost of w.p.c includes in the unit rate of item.
M&L for taking down existing treatment and applying Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels made by wooden beads with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately) including using white cement inplace of grey cement for grit wash complete all as directed.
Dismantling and surface preparation : Dismantling of plaster,cleaning and preparation of surface with the help of wire brush or grinder,remove all the loose concrete,grease,oil using wire brush and scrubber.All visible horizontal and vertical cracks in concrete more than 0.50mm width should be cut and open upto 6-10mm in U shape and fill with GP2,micro concrete,etc,admixed with SBR Polymer modified mortar. The concrete should be completely cured(concrete curing takes typically 28 days) and surface moister content should not be more than 8%.Injection and grouting :-Providing and applying injection grout additive Dr fixit pidicrete AM of M/s Pidilite Industries ltd or equivalent in fosroc/sika the product is to be dispensed in water & added to 50kg of cement at a water cement at a water cement ratio of 0.40-0.45. The mixture thus batched is to be used for injection grouting.Dr fixit Pidictere AM or equivalent in fosroc/sika has a bulk density of 0.7- 0.8gm/cc.storing and application to be done strictly in accordance with the manufacturer's instructions.Applicator to ensure complete surface preparation of steel substrate prior to applying the pidicrete AM or equivalent in/fosroc/sika. Application :All crevices and holes in concrete shall be fixed with Dr Fixit Polyplus CP powder or equivalent in fosroc/sika mixed with water in a ratio of 5 parts powder: 1 part water over a concrete substrate in a SSD condition.Apply two caots of Dr fixit Poly plus CP or equivalent in fosroc/sika at the rate (0.7-0.8kg/m2).Apply first coat of Dr fixit Polyplus CP or equivalent in fosroc/sika mixed in a ratio 5 parts powder : 2parts clean water with a clean brush.Use an aggressive circular motion of the brush or wooden float with Dr. Fixit Polyplus CP slurry or equivalent in fosroc/sika.Apply a second coat after 3 to 6 hours.Dr Fixit Polyplus CP or equivalent in fosroc/sika treated surface shall be left cure for 2-3 days as mentioned above and protect from direct sunlight for this initial period .For full cure give 28 days along with concrete complete all as specified and directed.
Starter joint/Construction Joint : Cleaning the surafce using compressed air system to ensure that the substrate is free from dust,laitance,debris,etc.Repairing cracks by cutting and making V groove in 25x25mm with SBR polymer modified mortar fliing the groove with cement:sand CM(1:3) mixed with polymer Dr fixit pidicrete URP or equivalent in fosroc/sika 10% by weight of cement,angle fillet made with SBR polymer modified filling the groove with cement:sand CM(1:3) mixed with polymer Dr Fixit Pidicrete URP or equivalent in fosroc/sika 10% by weight of cement complete all as specified and directed.
S&F as in repairs CP Health faucet with 1.50 Mtr flexible chromium plated tube and hook fixed to angle valve 15mm bore with accessories complete all as specified and directed.
S&F as in repairs Chromium plated jet spray with CP connection pipe for EWC, 15mm bore with fittings, complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail 20mm dia 60 cm long between flanges, fixed to walls with necessary screws complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel ring having dia of ring not less than 150mm fixed to walls with necessary screws complete all as specified and directed.
S&F in repairs CP brass bottle trap 32 mm dia including joining to waste fitting and waste pipe complete all as specified and directed.
Taking down carefully copper/Aluminium point wiring for light,Fan,Socket or power point complete including fittings and fixures such as switches, ceiling rose, pendents, regulators, sockets, light fittings etc. Removing materials to store to keeping in safe custody or taking credit (credit for above item should be made as per conditions separately) and making good disturbed surface of wall, floor etc.
M&L Point wiring with multistranded copper conductor PVC Insulated and unsheathed cable in PVC concealed conduit with 1.5 SQMM FRLSH cable with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Moduler fittings including acessories as moduler surface cover plate with frame, metal flush box, for one light/Fan/Exhaust Fan point complete and making good the existing disturbed surface.
Ditto as per item Ser No 171.00 but 5 Amp socket point indipendent complete all as specified and directed.
M&L for one point wiring of any length as per site requirment with PVC insulated FR LS unsheathed copper conductor cable of size 2.5 sqmm including earth wire of size 1.5 Sqmm in and including concealed PVC conduit including MS bos suitable of modular fittings ,inner and outer modular top sheet top cover, for one 3 pin socket outlet 15 Amps independent complete all as specified and directed.
S&F modular socket 6 amp-2/3 pin combined 2 module complete all as specified and directed.
S&F Modular switch 1 way 6 Amp 1 Module complete all as specified and directed.
S&F Modular socket 1 way 16 Amp 2 Module complete all as specified and directed.
S&F Modular switch 1 way 16 Amp 1 Module complete all as specified and directed.
S&F in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 4 core & cross-sectional area 16 sqmm complete all as specified and directed.
S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 3.5 core & cross-sectional area 25 sqmm complete all as specified and directed.
S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 3.5 core & cross-sectional area 50 sqmm complete all as specified and directed.
Supply and fixing in replacement of TPN DB 4 ways with 200 amps rated busbar 415 volt double door complete Make: Havells/Scheinider/Legrand complete all as specified and directed.
Supply and fixing in replacement of TPN DB 8 ways with 200 amps rated busbar 415 volt double door complete Make: Havells/Scheinider/Legrand complete all as specified and directed.
Supply and fixing in replacement of vertical TPN DB 12 ways with 200 amps rated busbar 415 volt double door complete Make: Havells/Scheinider/Legrand complete all as specified and directed.
S&F Isolator of 04 pole 100 amp 50 Hz 415 volts with rupturing capacity 16 KA complete all as specified and directed.
S&F MCB SP, C-curve, 230 V 6-32 Amps 10 KA complete all as specified and directed.
S&F in replacement MCB TPN, 32 Amp, C curve 50 Hz, 415 V with rupturing capacity 10 KA complete all as specified and directed.
S&F in replacement MCB TPN, 63 Amp, C curve 50 Hz, 415 V with rupturing capacity 10 KA complete all as specified and directed.
S&F in replacement 3 Pole MCCB, 125 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
S&F in replacement 4 Pole MCCB, 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
S&F in replacement 4 Pole MCCB, 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
S&F in replacement 4 Pole MCCB, 125 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
S&F in replacement 4 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
M&L for circuit/submain wiring for industrial socket alongwith earth wire of FRLSH PVC insulated copper conductor, single core cable in surface/recessed of size 2x6 Sqmm + 1x6 Sqmm earth wire including 25mm dia of PVC conduit concealed and lugs/thimble with nuts, bolts and washers etc complete all as specified and directed. Note :- 3 run of 6 Sqmm cable and one run of PVC conduit shall be measured one unit (RM)
Taking proper shutdown & Isolate the HT electric supply and taking out the trolley of VCB HT 11KV 630 Amps and servicing of all minor/major parts of the VCB by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber, spout, gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts of entire trolley, inserting the trolley, testing the complete HT electric supply and puting on supply on load complete all as specified & directed. Note:- (i) All cleaning /testing equipment/material shall be provided by the contractor and rate for the same are deemed to be included in quoted rates. (ii) The complete test report shall be submitted by the contractor to GE(I)/Engineer-in-Charge.
Taking shut down from main substation and drain out the transformer oil and to be collected in barrel by opening the transformer cover of capacity 1250 KVA by unscrewing the nuts/bolts and washers and kept in safe custody and reuse the same, and checking the any type of leakage from both HT and LT side including cleaning the sludge etc depositing in the core and tank by using soft brushes and clean with old transformer oil, refilling of transformer oil including refixing of top cover including nut/bolts etc and testing the input & output voltage and adjustment of the voltage through tape changer if required inculding providing & fixing monoplast putty at HT/LT cable connection of transformer complete for entire satisfaction of Engineer- in-charge.
Dehydration and filtration of transformer oil with proper dehydration machine to achieve dielectric strength between 45 to 60 KV including testing/recording of dielectric strength result before and after of dehydration complete all as specified and as directed. Note:- Test report shall be submitted by the contractor to the Engineer-in-Charge.
Supply and topping up transformer oil having dielectric strength not less than 45 KV - 60 KV complete all as specified and directed.
Taking shut down from main substation and M&L for painting to Transformer 1250 KVA with spray gun with two coats of synthetic enamel heat resistant grey paint over a coat of red oxide primer including preparation of old painted surfaces/removing old faded/rust/ cemented material of surface of transformer including base frame, connected LT panels, duct covers of including writing MES/SM No of existing size/surface complete all as specified & directed.
Supply and Fix in replacement of Dehydrating breather assembly complete with silica gel grains in the breather assembly suitable for transformers 1250 KVA complete as per matching to existing all as specified and directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed Note: Old fan shall be deposted to E/M store yard.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 m sweep with, blades, and frame and louvers complete all as specified and directed. Note: Old Exhaust fan shall be deposited to E/M store yard.
Taking down unserviceable ceiling 1200/1400 mm of any make dismantling cutting and removing of old burnt windings and rewinding with super enamelled copper winding wire of required size including allied insulation material, varnishm sleeves, etc greasing, oiling, re-assembling testing and refixing in the same position, complete all as specefied and directed.
All as per description of serial item No 200.00 above but wall mounted fans of any size and any make complete all as specified and directed.
All as per description of serial item No 200.00 above but exhaust fans of any size and any make complete all as specified and directed.
S&F in replacement capacitor of 3.15 Mfd including fixing complete and including necessary items such as sleeves etc complete all as specified and directed.
S&F in replacement step type electronic fan regulator AC 220 V Single phasecomplete all as specified and directed.
S&F in replacement bush / bearing of suitable size in ceiling fans of any size complete all as specified and directed.
S&F in replacement bush / bearing of suitable size in wall fans of any size complete all as specified and directed.
S & F in replacement bush / bearing of suitable size in exhast fans of size any size complete all as specified and directed.
S & F in replacement Metallic clamps for hanging of ceiling fans with bolts & nuts,, split pin etc complete all as specified and directed.
S & F in replacement Stator of ceiling fans of any size complete all as specified and directed.
S & F in replacement Rotor of ceiling fans of any size complete all as specified and directed.
S & F in replacement PVC canopy for ceiling fan (upper & lower) of any size complete all as specified and directed.
S & F in replacement Blade set for ceiling fans of any size with bolts etc. complete all as specified and directed.
S & F in replacement Blade set for wall mounted fans of any size with bolts etc. complete all as specified and directed.
S & F in replacement Metallic Blade set for Exhaust fans of any size with bolts etc. complete all as specified and directed.
S & F in replacement cast Aluminium Body cover for ceiling fans of any size with bolts etc. complete all as specified and directed.
S & F in replacement MS down rod of length 450/600 mm for ceiling fans of any size and make complete all as specified and directed.
S & F in replacement Metallic louvers for Exhaust fans of any size with bolts etc. complete all as specified and directed.
Removing existing hot & cold water copper/PVC flexible pipe connection from geyser and S&F new brass chromium plated water pipe with brass nut and washers of good quality about 45cm long in hot & cold water connections and connecting complete all as specified and directed.
Replacement of heating elements spiral /circular type 1.5 kW for 25ltrs capacity geyser, the heating element should be as per specified geyser any type ISI marked complete all as specified and directed.
Replacement of thermo static switch of geyser complete all as specified and directed. Make : Bajaj/Theta or equivalent as approved by GE.
Supply and fixing Fancy type Bib tap of cast copper alloy with crutch screwed down, screwed for iron pipe of 15mm bore complete all as specified and directed.
S&F in repair PVC insulated copper (flexible) conductor 2.5 Sqmm 3 core and connected to geyser complete all as specified and directed.
Welding with new brass studs for holding of heating element with replacement of suitable element holding clamps-3 nos complete all as specified and directed.
Detecting the leakage from geyser and arresting the same by brazing/soldering etc complete all as specified and directed.
Supply and fix NRV of 15mm dia cast iron all as directed at site complete all as specified and directed.
S&F Anchor fastning of suitable size for fixing geyser after dismantling old one complete all as specified and directed.
S&F water heater outer cover suitable for 25ltrs. Capacity of existing make including taking out old unserviceable complete all as specified and directed.
S&F water heater inner tank suitable for 25ltrs. Capacity of existing make including taking out old unserviceable complete all as specified and directed.
M&L for chemical earthing complete including earth work in any type of soil with clamp SITC of copper bounded Rod / Earthing termination bonded steel earth rods of 3 mtrs minimum length, 17.2 mm dia, interconnected with copper bonded flanges (Minimum copper bonding shall be 0.25 mm) along with Rod-to-Conductor connectors, and other accessories as per IS 3043, NBC 2016, IEEE 80, UL 467. CPRI tested at 25KArms along with 30 Kg pure carbon-based Earth Enhancement compound tested by NABL accredit lab for RDHS complying IEC 62561-7 in a sealed bag and inspection pit covers. Including copper strip 25x5mm not more than 7.5 meters complete all as specifeid and testing on completion with & including followings :- (a) PCC earth pit 30x30x30 cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15 mm thick plaster in CM 1:6 including RCC pit cover 25mm thick reinforced with 6mm dia TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (b) Angle iron frame made of 40x40x4 mm angle iron for 30x30cm PCC pit for holding the pit cover. (c) Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw - 02 Nos.
Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
Material and Labour for earthing complete with copper earth plate electrode 600mmx600mmx3.15mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. Copper plate connected with copper strip of 20x3 mm by means of Copper nuts, bolts and washers. Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) Copper strip of size 25mm x 3mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
S&F Earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases or burried in ground or drawn in coduit/pipe or any other indicated situation for loop earthing etc. as required 20x3 mm copper strip complete all as specified and directed.
S&F Earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases or burried in ground or drawn in coduit/pipe or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip complete all as specified and directed.
S&F DLP U-PVC trunking system size 100x50mm with all accessories for fittings including flexible cover complete all as specified and directed.
V.V CONSTRUCTIONS
m/s Kailash Chander
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .