Executive Engineer, Elect. Divn. PWD B and R Br., Ambala Cantt.
Const. of Sub Health Centre at Village Sunheri Khalsa in Distt. Kurukshetra (Pdg. Internal EI only) (Recall).
2020_HRY_120879_5
PWD/Elect-KNL/Elect-AMB/17062
Open Tender
Construction Works
Works
60 days
Ambala Cantt
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
E.E., Elect. Division PWD B and R Br.,
₹2,360
17 Mar 2021
7 Aug 2020
19 Aug 2020
7 Aug 2020
18 Aug 2020
7 Aug 2020
Amount
Main Switches Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections. Double pole switch 32 amp. 415 Volts, HSR No. 31.12(a)(v)Cat-B
Moulded case Circuit breakers. Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 15 amp.to 60 amp. 415 V ,10 KA 3-phase. HSR No. 31.12c(i)
100 amp.to 220 amp.415 V,10 KA 3-phase. HSR No. 31.12c(ii)
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. Size 50 mm x 50 mm x 6 mm. HSR No. 31.13(I)
M.S.Sheet . Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide. HSR No. 31.14(i)
Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp. HSR No. 31.17a)(ii)
TP MCB of 9 KA breaking capacity 6 amp. to 32 amp. HSR No. 31.17(a)(ii)
TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp. HSR No. 31.17(a)(iii)
(M)Supply and erection of Fittings and Accessories. Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point. HSR No. 31.18(xxiv)
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job. HSR No. 31.18(xxvi)
Bakelite angle / straight button holder large size. HSR No. 31.18(xi)
Switch 5 amp. On existing sheet. HSR No. 31.18(xii)
Wall socket 5 amp. On existing sheet. HSR No. 31.18(xiii)
(O)Erection and carriage of fans.. Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work. HSR No. 31.20(i)
Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work. HSR No. 31.20(iii)
Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep. HSR No. 31.20(vi)
(P)Pipe Laying. Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed. HSR No. 31.21(xxi)
Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed. HSR No. 31.21(xxii)
Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. PVC pipe 65 mm dia. HSR No. HSR No. 31.21(xxx)(c)
(Q) Earthing Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required . HSR No. 31.22(i)
Extra for using salt and charcoal / coke for pipe earth electrode as required. HSR No. 31.22(ii)
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required . HSR No. 31.22(xvi)
Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material. HSR No. 31.22(xv)
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. 1.5 sqmm to 2.5 sqmm. HSR No. 31.35(ix)(a)
4 sqmm to 6 sqmm. HSR No. 31.35(ix)(b)
10 sqmm . HSR No. 31.35(ix)(c)
PVC Insulated wiring in recessed conduit. Wiring in 1.5 sqmm PVC insulated copper conduct cable in 1.6 mm thick conduit pipe. Fan Point Fan Point - Medium . HSR No. 31.36
Fan Point- Long. HSR No. 31.36
Light point -Short. HSR No. 31.36(ii)
Light Point - Medium. HSR No. 31.36
Light Point- Long. HSR No. 31.36
3 pin 5 amp. plug point including earthing the 3rd. pin etc. - Short point. HSR No. 31.36(vii)a
3 pin 5 amp plug point including earthing the 3rd. pin etc. - Medium point. HSR No. 31.36(vii)b
3 pin 5 amp. plug point including earthing the 3rd. pin etc.- Long point. HSR No. 31.36(vii)c
3 pin 15 amp plug point including earthing the 3 rd. pin etc.with 4 sq mm PVC insulated Al.conductor cable - Long point. HSR No. 31.36(viii)c
Call bell point including M.S Box of size 180mmx100mmx60mm deep for call bell - Long point HSR No. 31.36(vi)c
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Size 1.5 sqmm (3 / 0.81mm). HSR No. 31.40(i)
Size 4 sqmm (7 / 0.85mm). HSR No. 31.40(iii)
Size 10 sqmm ( 7 / 1.35mm). HSR No. 31.40(v)
S/E of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. 4-way, SP & N (Horizontal) HSR No. 31.41(i)
8-way, TP & N (Horizontal) (8+24) HSR No. 31.41(vi)
S/E of PVC conduit pipe ISI marked (Medium) recessed in wall/ ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of the work. 20 mm dia HSR No. 31.44(a)
25 mm dia HSR No. 31.44(b)
Supply and erection of MS sadles and clamps on wall / RCC parapit for fixing underground cable at at distance of 0.60 metre centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect. HSR No. 31.48
Supply and erection of Socket size rotary step type electronic regulator for A.C. ceiling fan Anchor make Deluxe model No.50440 ISI/SSK make PC 561 operated on 120/280 V A.C. supply complete including cutting of existing bakelite sheet and making necessary connection etc up to the entire satisfaction of Engineer-in-Charge of work. HSR No. 31.55
Supply & erection of enclosure for MCCB 32/63 Amp. (Indo asian make) Complete with labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. (similar make of L&T, Havells & Standard). HSR No. NS-1
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .