| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | ₹32.5 L Quoted ₹34.3 L | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹40.0 L+₹5.7 L (16.5%)Rejected-Finance | ₹40.0 L+₹5.7 L (16.5%) | L2 | Rejected-Finance Being not L1 bidder |
| 3 | L3₹45.0 L+₹10.6 L (31.0%)Rejected-Finance D NO 9 2 1 1 VUDA QUATERS PITHAPURAM COLONY VISAKHAPATNAM PIN 530 003 | VISAKHAPATANAM | ANDHRA PRADESH | 530003 | ₹45.0 L+₹10.6 L (31.0%) | L3 | Rejected-Finance Being not L1 bidder |
| 4 | L4₹47.2 L+₹12.8 L (37.4%)Rejected-Finance | ₹47.2 L+₹12.8 L (37.4%) | L4 | Rejected-Finance Being not L1 bidder |
| 5 | L5₹48.5 L+₹14.2 L (41.2%)Rejected-Finance | ₹48.5 L+₹14.2 L (41.2%) | L5 | Rejected-Finance Being not L1 bidder |
| Sl No | Description | Qty | Unit | MSN ENGINEERING WORKS L1 | Jessica Engineering Works L9 | ALPHA ENGINEERING CONSTRUCTIONS L3 | MONITOR ENGINEERING WORKS L10 | RATNA ENTERPRISES L4 | SATYAM ENGINEERS L8 | SVG SUPPLIES L7 | RAHITHI INFRA L6 | SONI ENGINEERS CONTRACTORS L2 | PNR CONSTRUCTIONS L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00NOTES / INSTRUCTIONS FOR STRICT COMPLIANCE :- (a) The contractor shall obtain sample approval for all materials incorporating in the work as per condition 10 of IAFW-2249 and Special Condition 11 of tender document mentioned here-in-after. (b) The Engineer-in-charge may direct the contractor in writing to procure and deposit up to 50% quantity of the material with in 30 days from the date of commencment as required at site out of quantity to complete the scope of work. Remaining 50% shall be procured as per site requirement during progress of work.The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material to the store of concerned subdivision within 30 days from the receipt of written direction. Failing which contractor shall liable to pay a penal recovery of Rs. 5000/- per week, levied on the dues of contractor, subject to maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as Electrician / FGM / Technician etc., readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge. (e) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery etc., as per site requirement. | |||||||||||||
| 2.00 | Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; laying of cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil complete all as specified and directed. | 503 | Cum | 180 ₹90,540 | 280 ₹1,40,840 | 180 ₹90,540 | 263 ₹1,32,289 | 210 ₹1,05,630 | 150 ₹75,450 | 180 ₹90,540 | 180 ₹90,540 | 120 ₹60,360 Lowest | 220 ₹1,10,660 |
| 3.00 | Returning, filling in trenching with soil and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. | 300 | Cum | 100 ₹30,000 | 250 ₹75,000 | 100 ₹30,000 | 43 ₹12,900 | 80 ₹24,000 | 70 ₹21,000 | 125 ₹37,500 | 35 ₹10,500 Lowest | 50 ₹15,000 | 45 ₹13,500 |
| 4.00 | Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed. | 231 | Cum | 70 ₹16,170 | 250 ₹57,750 | 110 ₹25,410 | 53 ₹12,243 | 180 ₹41,580 | 90 ₹20,790 | 125 ₹28,875 | 40 ₹9,240 Lowest | 40 ₹9,240 Lowest | 45 ₹10,395 |
| 5.00 | M&L sand cushioning with River sand in trenches for protection of UG cable and including punning down complete all as specified and directed.
Note:- Punned thickness of sand coushioning shall only measured and paid. | 164 | Cum | 650 ₹1,06,600 | 1,400 ₹2,29,600 | 600 ₹98,400 | 973 ₹1,59,572 | 800 ₹1,31,200 | 850 ₹1,39,400 | 650 ₹1,06,600 | 600 ₹98,400 | 500 ₹82,000 Lowest | 650 ₹1,06,600 |
| 6.00 | Taking out existing un-serviceable XLPE Cable of any size in underground / alongwith pole or in any positon complete all as specified and as directed.
Note:- Excavation and earthwork (if required) shall be measured and paid separately. | 2,540 | RM | 31 ₹78,740 | 80 ₹2,03,200 | 20 ₹50,800 | 23 ₹58,420 | 12 ₹30,480 | 3 ₹7,620 Lowest | 5 ₹12,700 | 79 ₹2,00,660 | 50 ₹1,27,000 | 80 ₹2,03,200 |
| 7.00 | Laying only old existing serviceable bricks as cable protection laying in cable trenches complete all as specified and directed by Engr-in-Charge.
Note :- (i) Serviceable bricks obtained from taking down shall be re-used.
(ii) Sand cushioning will measured and paid separately. | 4,000 | Each | 2 ₹8,000 | 5 ₹20,000 | 1 ₹4,000 | 5 ₹20,000 | 2 ₹8,000 | 1 ₹4,000 | 0.5 ₹2,000 Lowest | 5 ₹20,000 | 2 ₹8,000 | 5 ₹20,000 |
| 8.00 | Supply & laying sub class 'B', class designation 75 bricks of old size, laid over sand cushioning along alignment of cable as protection to cable in trenches including taking out old bricks complete all as specified and directed.
Notes : (i) Sand cushioning will measured and paid seperately.
(ii) Serviceable brick shall be used for laying only, un-serviceable bricks will be issued to contractor under Schedule of Credit. | 14,288 | Each | 6.5 ₹92,872 | 11 ₹1,57,168 | 5 ₹71,440 | 9 ₹1,28,592 | 5 ₹71,440 | 12 ₹1,71,456 | 7 ₹1,00,016 | 8 ₹1,14,304 | 3 ₹42,864 Lowest | 7 ₹1,00,016 |
| 9.00 | S&F 100 mm bore dia galvanised steel tubing, light grade galvanised, laid under road crossing, for cable protection or fixed to poles, walls or laid under floors including taking down existing un-serviceable GI pipe complete all as specified and directed. | 40 | RM | 700 ₹28,000 | 850 ₹34,000 | 1,000 ₹40,000 | 1,813 ₹72,520 | 580 ₹23,200 | 450 ₹18,000 Lowest | 650 ₹26,000 | 1,000 ₹40,000 | 500 ₹20,000 | 950 ₹38,000 |
| 10.00 | All as per Sl item No. 8.00 here in before but 40 mm bore | 65 | RM | 400 ₹26,000 | 400 ₹26,000 | 400 ₹26,000 | 673 ₹43,745 | 280 ₹18,200 | 250 ₹16,250 Lowest | 280 ₹18,200 | 450 ₹29,250 | 400 ₹26,000 | 425 ₹27,625 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
8 Dec 2025, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINT OF DISTR FEEDER PILLAR BOXES, LT UG CABLES AND CONNECTED WKS OF LT DISTR SYS INCL ATTENDING FUSE OFF CALL AT NCB, 32 WEU/HF/DF, CE OFFC COMPLEX, NIRMAN PARK, 104, SVN COLONY AND MGEDDA AREAS UNDER AGE E/M-II OF GE(U-I) VISAKHAPATNAM
2025_MES_740184_1
8800/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Utility-I
₹98,000
Yes
5 Feb 2026
17 Nov 2025
10 Dec 2025
17 Nov 2025
8 Dec 2025
2 Dec 2025
Amount
NOTES / INSTRUCTIONS FOR STRICT COMPLIANCE :- (a) The contractor shall obtain sample approval for all materials incorporating in the work as per condition 10 of IAFW-2249 and Special Condition 11 of tender document mentioned here-in-after. (b) The Engineer-in-charge may direct the contractor in writing to procure and deposit up to 50% quantity of the material with in 30 days from the date of commencment as required at site out of quantity to complete the scope of work. Remaining 50% shall be procured as per site requirement during progress of work.The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material to the store of concerned subdivision within 30 days from the receipt of written direction. Failing which contractor shall liable to pay a penal recovery of Rs. 5000/- per week, levied on the dues of contractor, subject to maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as Electrician / FGM / Technician etc., readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge. (e) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery etc., as per site requirement.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; laying of cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in trenching with soil and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with River sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness of sand coushioning shall only measured and paid.
Taking out existing un-serviceable XLPE Cable of any size in underground / alongwith pole or in any positon complete all as specified and as directed. Note:- Excavation and earthwork (if required) shall be measured and paid separately.
Laying only old existing serviceable bricks as cable protection laying in cable trenches complete all as specified and directed by Engr-in-Charge. Note :- (i) Serviceable bricks obtained from taking down shall be re-used. (ii) Sand cushioning will measured and paid separately.
Supply & laying sub class 'B', class designation 75 bricks of old size, laid over sand cushioning along alignment of cable as protection to cable in trenches including taking out old bricks complete all as specified and directed. Notes : (i) Sand cushioning will measured and paid seperately. (ii) Serviceable brick shall be used for laying only, un-serviceable bricks will be issued to contractor under Schedule of Credit.
S&F 100 mm bore dia galvanised steel tubing, light grade galvanised, laid under road crossing, for cable protection or fixed to poles, walls or laid under floors including taking down existing un-serviceable GI pipe complete all as specified and directed.
All as per Sl item No. 8.00 here in before but 40 mm bore
M&L earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cmx 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point including dismantling existing un-serviceable earthing complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:2:4 type B1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 400 Sqmm x 3.5 Core, laid in trenches / passing through pipe / duct / on wall including taking down existing un-serviceable cable complete all as specified and directed.
All as per Sl item No. 16.00 here in before but cross sectional area 300 Sqmm x 3.5 Core
All as per Sl item No. 16.00 here in before but cross sectional area 240 Sqmm x 3.5 Core
All as per Sl item No. 16.00 here in before but cross sectional area 185 Sqmm x 3.5 Core
All as per Sl item No. 16.00 here in before but cross sectional area 150 Sqmm x 3.5 Core
All as per Sl item No. 16.00 here in before but cross sectional area 120 Sqmm x 3.5 Core
All as per Sl item No. 16.00 here in before but cross sectional area 95 Sqmm x 3.5 Core
All as per Sl item No. 16.00 here in before but cross sectional area 70 Sqmm x 3.5 Core
All as per Sl item No. 16.00 here in before but cross sectional area 50 Sqmm x 3.5 Core
All as per Sl item No. 16.00 here in before but cross sectional area 25 Sqmm x 4 Core
All as per Sl item No. 16.00 here in before but cross sectional area 16 Sqmm x 4 Core
M&L straight through joint kit, heat shrinkable type complete with jointing materials and accessories, suitable for 1.1 KV, 4 core LT XLPE aluminium conductor cable of size 6 to 16 Sqmm including taking down existing un-serviceable joint complete all as specified and directed. Note:- The cost of earth work & excavation shall deemed to included in the unit rate quoted against this item.
All as per Sl Item No. 3.00 here in before but suitable for cable of size 25 to 50 Sqmm
All as per Sl Item No. 3.00 here in before but suitable for cable of size 70 to 120 Sqmm
All as per Sl Item No. 3.00 here in before but suitable for cable of size 150 to 185 Sqmm
All as per Sl Item No. 3.00 here in before but suitable for cable of size 240 to 300 Sqmm
M&L for preparation of external surfaces of old existing LT panels indoor/outdoor type by scraping down old dusted paint by steel brush, brooming, rubbing and cleaning including spray painting with One coat of synthetic enamel paint and marking feeders complete all as specified and as directed by Engineer-in-Charge.
M&L with replacement of canopy, door, body angle iron support etc. of existing LT panel board, body made out of 2 / 3.15 mm thick CRCA sheet and support of angle sections as per existing, duly power coated with one coat of synthetic enamel paint over a coat of primer with removable door hinges, neoprone gasket and locking arrangement, including welding work for fixing the door complete all as directed. Note:- Unit rate quoted shall be considered to include hinges, locking arrangement, neoprone gasket etc reqd for LT panel. Contactor shall quote their rates accordingly.
S&F PVC Connector / terminal Post type/ strip type upto 400A capacity suitable for Metal/Polycarbonate feeder pillar including connection including taking down complete all as specified and directed.
M&L copper busbar of suitable size including taking down existing un-serviceable busbar complete all as specified and as directed
S&F in wiring Single core stranded copper conductor FRLSH of size 50 Sqmm including copper lugs at both ends.
All as per Sl item No. 34.00 here in before but size 25 Sqmm
All as per Sl item No. 34.00 here in before but size 16 Sqmm
All as per Sl item No. 34.00 here in before but size 10 Sqmm
S&F aluminium lugs to cable end suitable for cable of size of 06 to 16 sqmm including taking down existing un-serviceable lugs complete all as specified and directed.
All as per Sl item No. 38.00 here in before but suitable for cable of size of 25 to 50 sqmm
All as per Sl item No. 38.00 here in before but suitable for cable of size of 70 to 95 sqmm
All as per Sl item No. 38.00 here in before but suitable for cable of size of 120 to 240 sqmm
All as per Sl item No. 38.00 here in before but suitable for cable of size of 300 to 400 sqmm
S&F 800 Amps ACB (Air Circuit Breaker), 4 Pole, 415 V with microprocessor release (manual drawout type), breaking capacity 50kA including taking down old un-serviceable ACB complete all as specified and directed.
S&F MCCB 4 pole 630 Amps, breaking capacity 50 kA, Ics = 100% Icu, thermal magnetic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 lr) including necessary modification in the panel & taking down existing un-serviceable MCCB complete all as specified and as directed.
All as per Sl Item No. 44.00 above but 400 Amps breaking capacity 36 KA
All as per Sl Item No. 44.00 above but 320 Amps breaking capacity 36 KA
All as per Sl Item No. 44.00 above but 250 Amps breaking capacity 36 KA
All as per Sl Item No. 44.00 above but 200 Amps breaking capacity 36 KA
All as per Sl Item No. 44.00 above but 160 Amps breaking capacity 36 KA
All as per Sl Item No. 44.00 above but 100 Amps breaking capacity 16 KA
All as per Sl Item No. 44.00 above but 63 Amps breaking capacity 16 KA
All as per Sl Item No. 44.00 above but 3 Pole 400 Amps breaking capacity 50 KA
All as per Sl Item No. 44.00 above but 3 Pole 320 Amps breaking capacity 50 KA
All as per Sl Item No. 44.00 above but 3 Pole 250 Amps breaking capacity 36 KA
All as per Sl Item No. 44.00 above but 3 Pole 200 Amps breaking capacity 36 KA
All as per Sl Item No. 44.00 above but 3 Pole 160 Amps breaking capacity 36 KA
All as per Sl Item No. 44.00 above but 3 Pole 100 Amps breaking capacity 16 KA
All as per Sl Item No. 44.00 above but 3 Pole 63 Amps breaking capacity 16 KA
Boring holes horizontally under road, manually, in soft / loose soil, without cutting / disturbing the existing road surface, suitable for inserting HDPE pipe of n exc. 150 mm bore at a depth 0.75 m to 1.0 m from road surface for passing of UG cable, getting out and disposal of soil to a distance not exceeding 50 m complete all as specified and as directed. Note:- 150 mm HDPE pipe rates are deemed to be included in qouted rate.
S&F in repairs for cable route indicator for LT UG cable, 1100 Volt grade made out of 4mm thick MS sheet in round shape of dia not less than 200mm, embossed with LT Cable on it, bolted with 2 nut of suitable size at top of 40 x 6 mm MS flat iron of length not less than 1 meter, complete metal surfaces painted with 2 coats of synthetic enamel paint over a coat of primer & bottom of flat iron embedded in PCC 1:3:6 type C2 of size 200mm x 200mm x 500mm (400mm below ground level and 100mm above ground level), exposed surface of concrete painted with 3 coats of white wash including necessary earth work complete all as specified and directed. Note:- Rate qouted shall deemed to be inclusive of cable route indicator, earth work, excavation and concrete complete.
M&L for cutting the tarmac / hard standings in road and excavating trenches across the road in size not exceeding 0.45 m wide and 0.6 m depth for laying cable including refilling earth & making good top surface of the disturbed portion with 100mm thick PCC 1:3:6 or bituminous mix as per existing & matching with the surroundings complete all as specified and directed. Note : Rate quoted shall deemed to inclusive of road cutting of any description, earth work excavation and making good on top with 100 thick PCC complete.
M&L for brick in CM 1:4 rendering using sub class B bricks straight or curved on plan exceeding 6 Mtr mean radius including dismantling old structure complete all as specified and directed.
M&L 15 mm thick rendering in CM 1:6 on stone masonry surfaces or surface other than fair face of brick work or on one side of lathing, finished even and smooth without using extra cement complete all as specified and directed.
S&F Metal Rotary type locks for CRCA Sheet Panels including taking down existing un-serviceable locks complete all as specified and directed.
S&F Current transformer, for Amps not exceeding 400 Amp for suitable ratio 400/5A as existing including wiring with Ammeter complete all as specified and directed.
M&L for detecting LT UG cable faults located in any stretch / depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave receiver, cable identification instrument , cable tracer for exact location of under ground cable routes complete all as directed. Note:- The rate quoted deemed to be inclusive of arrangement of necessary fault locator equipment, transportation of equipment& charges for service engineer.
M&L aluminium busbar of suitable size including taking down existing un-serviceable busbar complete all as specified and as directed
S&F cubical type LTPanel Board, outdoor type, factory made from CPRI approved factory, made out of 3.15 mm thick CRCA steel sheet and including MS angle iron 50 x 50 x 6 mm frame work, legs 0.6 m long, MC 100 channel base, totally enclosed, dust & vermin proof using neoprene rubber gasket (IP-54), double leaf door shutter in front side and double leaf shutter in rear side fixed with hinges having necessary locking arrangement in both front and rear door including handles, with four side projected slanting roof, provided with louvers for ventilation / heat dissipation, danger notice plate, duly painted with seven tank treatment process and including mounting on PCC platform made out of PCC (1:3:6) type C1 (20 mm graded stone aggregate), 150 mm thick (100 mm below & 50 mm above GL) and including necessary form work, earth work and excavation (Contd...)
S&F cubical type LTPanel Board, outdoor type, factory made from CPRI approved factory, made out of 3.15 mm thick CRCA steel sheet and including MS angle iron 50 x 50 x 6 mm frame work, legs 0.6 m long, MC 100 channel base, totally enclosed, dust & vermin proof using neoprene rubber gasket (IP-54), double leaf door shutter in front side and double leaf shutter in rear side fixed with hinges having necessary locking arrangement in both front and rear door including handles, with four side projected slanting roof, provided with louvers for ventilation / heat dissipation, danger notice plate, duly painted with seven tank treatment process and including mounting on PCC platform made out of PCC (1:3:6) type C1 (20 mm graded stone aggregate), 150 mm thick (100 mm below & 50 mm above GL) and including necessary form work, earth work and excavation (Contd...)
S&F cubical type LTPanel Board, outdoor type, factory made from CPRI approved factory, made out of 3.15 mm thick CRCA steel sheet and including MS angle iron 50 x 50 x 6 mm frame work, legs 0.6 m long, MC 100 channel base, totally enclosed, dust & vermin proof using neoprene rubber gasket (IP-54), double leaf door shutter in front side and double leaf shutter in rear side fixed with hinges having necessary locking arrangement in both front and rear door including handles, with four side projected slanting roof, provided with louvers for ventilation / heat dissipation, danger notice plate, duly painted with seven tank treatment process and including mounting on PCC platform made out of PCC (1:3:6) type C1 (20 mm graded stone aggregate), 150 mm thick (100 mm below & 50 mm above GL) and including necessary form work, earth work and excavation (Contd...)
SONI ENGINEERS CONTRACTORS (BID ID -3492332)
ALPHA ENGINEERING CONSTRUCTIONS (BID ID -3492046)
RATNA ENTERPRISES (BID ID -3492431)
PNR CONSTRUCTIONS (BID ID -3491425)
RAHITHI INFRA (BID ID -3498501)
SVG SUPPLIES (BID ID -3496808)
SATYAM ENGINEERS (BID ID -3497352)
Jessica Engineering Works (BID ID -3492027)
MONITOR ENGINEERING WORKS (BID ID -3492089)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
8800Tender.pdf
Tender Documents • 0.76 MB
BOQ_828811.xls
BOQ • 1.79 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .