Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 CrAdmitted-Finance | ₹5.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹5.7 CrAdmitted-Finance GYAMDU HOUSE OLD ROAD SHANAM LEH LADHAKH UT PIN 194101 | LEH LADAKH | LADAKH | 194101 | ₹5.7 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically not viable |
| 4 | Rejected-Technical 4 D SHASTRI NAGAR JAMMU J K UT PIN 180004 | JAMMU | JAMMU | J K UT | 180004 | - | - | Rejected-Technical Technically not viable |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically not viable |
| Sl No | Description | Qty | Unit | M/S MASOOD AHMED CONTRACTOR L1 | Taru Enterprises Pvt Ltd L2 |
|---|---|---|---|---|---|
| 1.00RESURFACING WORKS BETWEEN BETWEEN KM 18.000 TO KM 35.000 ON NPD ROAD (ALTITUDE - 3301 to 3600 Mtr) | |||||
| 1.01 | Application of Tack Coat by mechanical means conforming to clause 503 of MORT&H (Fifth Revision) specifications as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract | 1,33,958 | Sqm | 49 ₹65.6 L | 23 ₹30.8 L |
| 1.02 | Providing and laying of DBM of 50 mm compacted thickness conforming to clause 505 of MoRT&H (Fifth Revision) specifications as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract. | 9,596 | Sqm | 350 ₹33.6 L | 500 ₹48.0 L |
| 1.03 | Providing and laying of Bituminous Concrete of 30 mm compacted thickness conforming to clause 507 of MoRT&H (Fifth Revision) specifications as specified in Particular Specifications or as directed by Engineer-In-Charge/ OC Contract. | 1,24,362 | Sqm | 339 ₹4.2 Cr | 350 ₹4.4 Cr |
| 1.04 | Providing and marking of Centre / Edge line with thermoplastic paint and glass beads with road marking machine conforming to clause 803 of MORT&H (Fifth Revision) specifications as specified in Particular Specifications or as directed by Engineer-In-Charge/ OC Contract. | 4,089 | Sqm | 550 ₹22.5 L | 550 ₹22.5 L |
| 1.05 | Earth work in embankment filling for earthen shoulders with earth free from roots etc. spreading in layers not exceeding 30 cm including watering and finishing to required slope & level not exceeding 1.5 m high above the base in ordinary soil in hill roads where cut & fill method is adopted mechanical/manual means conforming to clause 408 of MORT&H (5th Revision) specifications as specified in Particular Specifications and notes of Sch ‘A’ and as directed and approved by Engineer-in-Charge and OC Contract. | 1,015 | Cum | 350 ₹3.6 L | 650 ₹6.6 L |
| 1.06 | Providing and fixing of road stud 100x100 mm, diecast in aluminium, resistant to corrosive effect of salt and grit, fitted with lens reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973 and notes of Sch ‘A’ and as directed and approved by Engineer-in-Charge. | 4,236 | Nos | 300 ₹12.7 L | 390 ₹16.5 L |
| 1.07 | Supplying and installation of delineators (600 mm) (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100 mm rectangular or 75 mm dia circular refelectorised panels at the top, buried or pressed into the ground and conforming to IRC:79 and the drawings, all complete as per clause 805 of MoSRT&H specifications and notes of Sch ‘A’ and as directed and approved by Engineer-in-Charge. | 1,411 | Nos | 800 ₹11.3 L | 900 ₹12.7 L |
Tender Value
₹8.7 Cr
EMD Value
₹7.6 L
Closing Date
18 Mar 2026, 6:00 pmClosed
Chief Engineer Project Yojak
HQ CE Project Yojak Near Solang Valley Manali Distt Kullu Himachal Pradesh 175103
RESURFACING WORKS ON NIMMU-PADAM-DARCHA ROAD IN BETWEEN KM 18.000 TO KM 35.000 UNDER 114 RCC 13 BRTF UNDER PROJECT YOJAK IN LADAKH (UT) (2nd Call)
2026_BRO_747344_2
CE (P) YJK/12/2025-26
Open Tender
Civil Works - Roads
240 days
114 RCC 13 BRTF NPD Road
As per tender
8 documents required · 8 mandatory
₹0
₹7.6 L
Yes
15 Apr 2026
28 Feb 2026
19 Mar 2026
28 Feb 2026
18 Mar 2026
9 Mar 2026
2 Mar 2026 - 6 Mar 2026
RESURFACING WORKS BETWEEN BETWEEN KM 18.000 TO KM 35.000 ON NPD ROAD (ALTITUDE - 3301 to 3600 Mtr)
Application of Tack Coat by mechanical means conforming to clause 503 of MORT&H (Fifth Revision) specifications as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract
Providing and laying of DBM of 50 mm compacted thickness conforming to clause 505 of MoRT&H (Fifth Revision) specifications as specified in Particular Specifications or as directed by Engineer-In-Charge/OC Contract.
Providing and laying of Bituminous Concrete of 30 mm compacted thickness conforming to clause 507 of MoRT&H (Fifth Revision) specifications as specified in Particular Specifications or as directed by Engineer-In-Charge/ OC Contract.
Providing and marking of Centre / Edge line with thermoplastic paint and glass beads with road marking machine conforming to clause 803 of MORT&H (Fifth Revision) specifications as specified in Particular Specifications or as directed by Engineer-In-Charge/ OC Contract.
Earth work in embankment filling for earthen shoulders with earth free from roots etc. spreading in layers not exceeding 30 cm including watering and finishing to required slope & level not exceeding 1.5 m high above the base in ordinary soil in hill roads where cut & fill method is adopted mechanical/manual means conforming to clause 408 of MORT&H (5th Revision) specifications as specified in Particular Specifications and notes of Sch ‘A’ and as directed and approved by Engineer-in-Charge and OC Contract.
Providing and fixing of road stud 100x100 mm, diecast in aluminium, resistant to corrosive effect of salt and grit, fitted with lens reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973 and notes of Sch ‘A’ and as directed and approved by Engineer-in-Charge.
Supplying and installation of delineators (600 mm) (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100 mm rectangular or 75 mm dia circular refelectorised panels at the top, buried or pressed into the ground and conforming to IRC:79 and the drawings, all complete as per clause 805 of MoSRT&H specifications and notes of Sch ‘A’ and as directed and approved by Engineer-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_845365.pdf
techsummary_845365.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.86 MB
TenderResurf12.pdf
Tender Documents • 0.63 MB
IP_T12.pdf
Additional Documents • 3.00 MB
BOQ_845365.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid