| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC | L1 | Accepted-AOC Due to lowest accepted | |
| 2 | L2₹9.8 L+₹7,150 (0.73%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹10.2 L+₹46,804 (4.81%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹10.7 L+₹91,725 (9.42%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹12.1 L+₹2.3 L (24.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
2 Sept 2021, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Service Near Jagraon Bridge Ludhiana
REPAIR /MAINT TO GEYSERS, SOLAR WATER HEATER AND MISC E/M ITEMS UNDER GE LUDHIANA
2021_MES_464173_1
GE/LDH-22/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Under GE Ludhiana
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹30,000
Yes
13 Sept 2021
31 Jul 2021
3 Sept 2021
31 Jul 2021
2 Sept 2021
12 Aug 2021
1 Aug 2021 - 11 Aug 2021
Amount
Taking down geyser of capacity 25/ 35/ 50 litre after disconnecting water supply and electric connection and re-connecting the same after repairs complete all as specified & directed by Engineer-in-charge.
M&L for opening electric geyser of capacity 25/ 35 litre, taking out the inner tank, glass wool, geyser assembly, heating element and thermostat etc., cleaning, painting the complete geyser using iron brush/ iron rod and taking out the dirt & other deposits, re-assembling the geyser after replacing the defective parts and refilling the glass wool etc. complete all as specified & directed by Engineer-in-charge.
All as per item No. 2 above but capacity of geyser 50 litre.
Supply and replacement of heating element single phase 230 volts with rubber gasket; push type round shape of capacity 2 KW all as specified & directed by Engineer-in-charge.
All as per item No. 4 above but capacity of element 1.5 KW for solar water heater compelete all as Specifeid
All as per item No. 4 here-in-before above but element of triangular shape of capacity 2.0 KW.
Supply and replacement of thermostat single phase 230 volts with setting range 0° C to 85° C all as specified & directed by Engineer-in-charge.
Supply and replacement of geyser assembly having copper base and piping with 9/8/6 holes all as specified & directed by Engineer-in-charge.
Supply and replacement of worn out/ leaking inner steel/iron body water tank for 25 litre capacity geyser all as specified & directed by Engineer-in-charge.
Supply and replacement of worn out/ leaking steel/iron body water tank for 35 litre capacity geyser all as specified & directed by Engineer-in-charge.
Supply and replacement of worn out/ leaking inner steel/iron body water tank for 50 litre capacity geyser all as specified & directed by Engineer-in-charge.
Supply and replacement of phase indicator button type round shape all as specified & directed by Engineer-in-charge.
Supply and replacement of fusible plug of existing shape and size all as specified & directed by Engineer-in-charge.
Supply and replacement of base plate in two parts of existing size all as specified & directed by Engineer-in-charge.
Supply and replacement of air/pressure release valve all as specified & directed by Engineer-in-charge.
Supply and filling in glass wool for packing between inner & outer geyser assembly all as specified & directed by Engineer-in-charge.
Supply and replacement of old/ rusted and worn out geyser outer cover for 50 litre capacity geyser all as specified & directed by Engineer-in-charge.
Supply and replacement of old/ rusted and worn out geyser outer cover for 25 litre capacity geyser all as specified & directed by Engineer-in-charge.
Supply and replacement of PVC connection 15mm size with brass nuts of length 600mm all as specified and directed by Engineer-in-charge.
Taking down Solar water heater of capacity 100 ltrs/200 ltrs/500 ltrs and repair /maint of unsv items and re-fixed in original position (Spare items will be paid in respective items ,complete all as specified and directed by Engineer-in-Charge
S&F for solar tube suitable for 100/200/500 Ltrs capacity all as specified and directed by Engineer-in-Charge.
Taking down of GI pipe medium grade of size 20 mm dia complete all as specified and directed by Engineer-in-Charge.
Taking down of GI pipe medium grade of size 25 mm dia complete all as specified and directed by Engineer-in-Charge.
Refixing old 20mm bore steel tubing and connections in new/ old location using new fittings fixed complete to walls and ceiling or laid in floors/ concealed in walls complete, all as specified & directed by Engineer-in-charge.
Refixing old 25mm bore steel tubing and connections in new/ old location using new fittings fixed complete to walls and ceiling or complete, all as specified & directed by Engineer-in-charge.
Supply & fixing in replacement bib tap cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge.
Supply & fixing in replacement stop valve cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for unions suitable for size 15mm bore complete, all as specified & directed
Supply & fixing for steel water tubes of size 25mm bore (medium grade) galvanised with all fittings and fixed complete to walls and ceiling or laid in floors/ concealed in walls
Supply & fixing for steel water tubes of size 20mm bore (medium grade) galvanised with all fittings and fixed complete to walls and ceiling or laid in floors/ concealed in walls
S&F for heating element single phase 230 V complete with rubber gasket push type round shape all as specified & directed of capacity 3.0 KW suitable for solar water heater back up complete, all as specified & directed.
Taking down Exhaust fan 250/300mm sweep of any make/ model and repairing by removing burnt / heated copper winding from stater and rewinding the stater coils with super enamelled copper wire of suitable size including providing insulation material, varnishing, painting and provision of cotton tape, re-assembling and testing including replacement of spring washer and two core flexible wire of size 23/.0076 with copper conductor of suitable length from fan terminal to ceiling rose and refixing in in same or or other position as directed complete all as specified and directed. Make of winding wire: DEVIDAYAL/ NATIONAL.
All as per item No.31 here-in-before but exhaust fan of sweep 380mm.
All as per item No. 31 here-in-before but exhaust fan of sweep 450mm.
Supply and replacement of unserviceable ball bearings of exhaust fan 300mm/ 380mm sweep complete all as specified and directed. Make: NBC/ SKF.
Supply and replacement of gun metal bush for exhaust fan 300mm/ 380mm sweep including lath work etc complete all as specified and directed.
Supply and replacement of condenser 2.5/3.15 mfd oil filled type all as specified and directed.Make: Unistar/ Crompton/ Sharda/ Epcos.
Supply and replacement of condenser 4.0 mfd oil filled type all as specified and directed. Make: Unistar/ Crompton/ Sharda/ Epcos.
Supply and replacement of rubber reel set with nuts, bolt and washer etc. complete all as specified and directed.
Supply only HT imprignated insulation tape 15mm wide of length 15 mtr complete all as specified and directed by Engineer-in-Charge.
Supply only LT insulation tape 15mm wide of length 25 mtr complete all as specified and directed by Engineer-in-Charge.
S & F for FRLS PVC insulated & unsheathed stranded copper conductor single core cable 1100 volts grade of size 1.5 sqmm conforming to IS 694 Make Plaza/Havells/National
Supply and fix for non return valve ( NRV) GM alloy screwed of size 15 mm bore. Make : BIR/ VARUNA/SANT/VENUS/Zoloto
S & F for steel wire gauge Connection pipe suitable for 25/35/50 ltrs capacity length of pipe 600mm for geysers complete all as specified and directed by engr in charge
S & F for FRLS PVC insulated & unsheathed stranded copper conductor single core cable 1100 volts grade of size 2.5 sqmm conforming to IS 694 Make Plaza/Havells/National
Supply and fix in replacement of socket 15 Amps three pin, 240 volt flush type complete all as specified and directed by Engineer-in-Charge. Make- Anchor/Havells/Indo-Asian/ Hager
Supply and fix in replacement of switch 15 Amps flush type complete all as specified and directed by Engineer-in-Charge. Make- Anchor/Havells/Indo-Asian/ Hager
Supply and fix in replacement of double pole one way switch 240 volt 20 Amps with indicator lamp complete all as specified and directed by Engineer-in-Charge. Make- Anchor/Havells/Indo-Asian/ Hager
Supply and fix in replacement of of plug top 15 amps three pin complete all as specified and directed by Engineer-in-Charge. Make- Anchor/Havells/Indo-Asian/ Hager
M & L in replacement of for galvanised steel tubing 15mm dia medium grade (ISI marked) including fitting and fixing arrangements on wall/ceiling complete all as specified and directed .
Supply and fix in replacement of of Bell AC 230 volts single pole complete all as specified and directed.Make- Anchor/Havells/Indo-Asian
Supply and fix in replacement of of Bell push, flush type , 5 amp 230 volts single pole complete all as specified and directed.Make- Anchor/Havells/Indo-Asian
Supply and fix in replacement of switch 5 Amp one way ,240 volt flush type complete all as specified and directed .
S & F for FRLS PVC insulated & unsheathed stranded aluminium conductor two core cable 1100 volts grade of size 10.0 sqmm conforming to IS complete all as specified and directed .
Supply and fix in replacement of stepped type electronic fan regulator flush type on the existing phenolic laminated steel etc as required.complete all as specified and directed .
M & L in replacement sub main wiring complete with 2 runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 2.5 Sqmm single core PVC insulated FR cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc all as specified and as directed Note : 2 runs of 4 sqmm, 1 run of 2.5 sqmm earth conductor and 1 run of PVC conduit shall be measured as one unit length
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .