Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹7.3 L+₹61,075 (9.08%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹7.4 L+₹63,705 (9.47%)Rejected-AOC YADIPORA PHALHALLAN TEH PATTAN DISTT BARAMULLA J K | PATTAN | BARAMULLA | JAMMU AND KASHMIR | 193121 | L3 | Rejected-AOC Rejected | |
| 4 | L-4₹7.4 L+₹67,800 (10.1%)Rejected-AOC | L-4 | Rejected-AOC Rejected | |
| 5 | L5₹7.4 L+₹70,020 (10.4%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
4 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 969 EWS
GE 969 EWS c o 56 APO
PROVN OF DESLUDGING CLEANING AND REPAIR TO SEWAGE LINE SOKAGE WELL SEPTIC TANKS AT PATTAN UNDER GE 969 EWS
2020_MES_384038_1
CANO 969/WS- /2020-21
Open Tender
Civil Works
Item Rate
240 days
Pattan
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹16,000
Yes
14 Jan 2021
6 Oct 2020
6 Nov 2020
6 Oct 2020
4 Nov 2020
20 Oct 2020
60 days
Amount
Demolition of brickwork or stone masonary or block masonary etc built in cement mortar of any description including Excavation and removal where ever required for embeded portion. Complete all as specified and directed by Engineer-In-Charge.
Taking down cement plaster on brick or stone walls etc from drain, walls and Manholes etc. including raking out joints, hacking for key, scrubbing down with water etc. Complete all as specified and directed by Engineer-In-Charge.
M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in as in mass concrete. Complete all as specified and directed by Engineer-In-Charge.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6. Complete all as specified and directed by Engineer-In-Charge.
All as per item No. 5 above but except stones incld dismantling. Complete all as specified and directed by Engineer-In-Charge.
M&L for brick work with sub class 'B' bricks (Old size) straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6. Complete all as specified and directed by Engineer-In-Charge.
M&L for PCC (1:2:4) type B1 (using 20 mm gradedsone aggregate) as in copings etc including all necessary form works. Complete all as specified and directed by Engineer-In-Charge.
M&L for rendering 15 mm thick in CM 1:4 over stone wall surfaces and finished even & smooth without using extra cement. Complete all as specified and directed by Engineer-In-Charge.
All as per in item No 9 above but on brick or concrete surfaces. Complete all as specified and directed by Engineer-In-Charge.
Demolition of concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level). Complete all as specified and directed by Engineer-In-Charge.
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregates as in bed to drain pipes including packing under and haunching against the sides of pipes after these are laid tested for 150 mm bore of pipes. Complete all as specified and directed by Engineer-In-Charge.
Taking out (desilting) silt brick bats, debries, liquid waste sludge in solid/semi solid state from manholes/soakage well including pumping out sludge water wherever necessary, plugging diverting the flow in the drain, if necessary and stacking the removed silts in depots away from the edge of manholes as directed including use of safety belts and taking similar precautionary measures and removing the sludge etc. to a distance exc 250 mtr. but n.exc 500m & levelling the manhole cleaned and flushed with water, incl excavation and filling in after desludging etc. all as specified /directed manholes upto the depth of 1.00 mtr. Complete all as specified and directed by Engineer-In-Charge.
Desludging of septic tanks and manholes any capacity , size and depth including disposal of waste water and sludge mechanically/Using honey sucker machine and dividely store in covered container etc complete and removing the sludge in covered van/trolly inside the defence land and taking off the manhole cover and placing in the same position after taking out sludge and covering pit with minimum 30 cm thick layer of earth work etc Complete all as specified and directed by Engineer-In-Charge. NOTES :- The unit rate for desludging using Honey sucker Machine including hiring rate from any sources, Its operator, Hose required(at least 50 mtr) and Fuel etc. Per Trip of Truck shall deemed to include full capacity of Tank of the Truck i.e 3.0 to 4.0 Cum and the cost of dewatering shall also be included in the unit rate. Contractor has to excavate 2 mtr dia and at 3.00 mtr depth desludging well whereever shown by Engr-in-Charge for delivery point of desludging in side of Defence land at any distance as required also included in the rates. Desdging point has to returning filing after use and spread bleaching powder for hygeininc point of view. Contractor concern will liaise with the sources of Honey Sucker Machine and during working any defects raised contractor will be responsible in all respect. Complete all as specified and directed by Engineer-In-Charge.
M&L for cleaning of blockage of sewage lines, manholes of any dia & any depth in any situation by way of cleaning of manholes sewage as well as rodding to and fro, flushing with watering in sewage lines between successive manholes and keeping the systen functional connecting from floor traps, water closerts, soil waste and vent pipes, gully traps upto final drop/outlet into septic tanks/central sewage system by removing all blockages of any description in any situations manually or mechanically including cleaning of blockage of vents/solid/waste RWP of any description and any dia at Pattan by employing daily one sweeper only along with T&P as required. Complete all as specified and directed by Engineer-In-Charge.
Demolition and breaking up drain pipe (AC,saltglazed, PVC or RCC pipes ) set in CM or any description incl Excn of Earthwork , RFR, removal and making good of any dia. Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors fixed complete using PVC solvent and necessary testing including taking out etc. Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs 110 mm bore PVC (SWR) bends/Tee etc. Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors fixed complete using PVC solvent and necessary testing etc. Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs 75 mm bore PVC (SWR) bends/Tee etc fixing complete. Complete all as specified and directed by Engineer-In-Charge.
M/S GHULAM RASOOL LONE AND SONS
M/S MANZOOR AHMAD YATOO
M/S GHULAM MOHD LONE AND CO
M/S ALTAF HUSSAIN KHUROO
M/S ABDUL MAJID LONE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .