Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.3 LAccepted-AOC 2 158 VAIKKAKARA HOUSE AKALOOR PO OTTAPALAM PALAKKAD 679302 | OTTAPALAM | PALAKKAD | KERALA | 679302 | L1 | Accepted-AOC L1 | |
| 2 | L2₹79.9 L+₹77,576 (0.98%)Rejected-Finance VADAKKEMANNIL PUTHUR AKALUR PALAKKAD 679302 | AKALUR | PALAKKAD | KERALA | 679302 | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical not qualified |
Tender Value
₹94.4 L
EMD Value
₹50,000
Closing Date
11 Jan 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HOD INFRA
KERALA STATE INDUSTRIAL ENTERPRISES
Setting up of Eye OT Laminar Flow Operation Theatre at THQH Kanjirappally
2022_KSIE_541578_2
CP/INFRA/NHM/01
Open Tender
Civil Works - Others
Item Rate
120 days
Kanjirapally Kottayam
as per tender document
8 documents required · 8 mandatory
₹2,950
Yes
₹50,000
Yes
15 Feb 2023
4 Jan 2023
13 Jan 2023
4 Jan 2023
11 Jan 2023
4 Jan 2023
Amount
OPERATION THEATRE
Wall Cladding : Supply & installation of Pre Fabricated Modular /Laminar Operation Theatre Wall using 0.8mm 304 grade SS sheets on both sides of the 50mm thick Puff Panel.Filling of all joints and cavities with high quality silicone to provide a seamless finish as per detailed specification and as directed by the Engineer incharge
Ceiling Cladding : Supply & installation of Pre Fabricated Modular/Laminar Operation Theatre Ceiling using 0.8mm 304 grade SS sheets on both sides of the 50mm thick Puff Panel.Filling of all joints and cavities with high quality silicone to provide a seamless finish as per detailed specification and as directed by the Engineer incharge.
OT Flooring: Supply and installation of Imported Vinyl Floor: Seamless antistatic conductive ESD vinyl flooring system, 2mm thick, after self levelling the floor to avoid undulations, with perfectly curved flush covings and copper strips for earthing, all joints welded properly including wall skirting etc. as per detailed specification and as directed by the Engineer incharge. ( MAKE: TARKETT, GERFLOR )
Complete Plenum System with Hepafilters-Indigenous : Laminar Air Flow : Supply, Installation, Testing & Commissioning of laminar station and Aluminium plenum as follow: Laminar flow diffuser essentially should consists in: A plenum, constituting the pressurization chamber,entirely constructed of 1 mm-thick 304 grade Stainless steel sheet, with smooth finish to prevent dust collection. Four square flanges are mounted to connect the plenum to air distribution ducts. External stiffening ribs and anticondensation insulation. Filtering unit consisting of absolute filters with efficiency > 99.97%. Classification: CEN EN 1822 - H14. Sealed, stainless steel central component for connection of the surgical lamp. Lower component should consists of 1mm-thick SS panels with conveniently sized slots to assure the requested flow. The special system allows the perforated panels to be locked in and fully opened for easy and safe servicing and replacing of filters. SS mounting frame, constructed so as to assure sealed connection to the suspended ceiling, and perfect separation from the controlled work area by means of synthetic rubber seals. Diffuser Size: 2400x2400mm etc. as per detailed specification and as directed by the Engineer incharge.
Automatic Hermetically sealing Sliding Door : SITC of Automatic Hermatically Sealed Sliding Door size H2100 x W 1500MM X 45MM , having SS 304 Sheet on both sides filled with high quality Puff injected between two panels with viewing window of 300 x 300mm etc.as per detailed specification and as directed by the Engineer incharge. Size : (1500 x 2100 ) ( MAKE : METAFLEX/ ALANTA )
SS 304 Surgical Scrub Sink -Manual-Indigenous : Providinng and fixing "1 bay " Surgical Scrub Sink made out of 304 Stainless Steel & seamless welded construction polished to a satin finish having front acess panel with following features : --Foot Operation etc asper specification and as directed by the Engineer incharge
Surgeon Control Panel with Electrical Distribution Board - Indigenous : Providing, Fixing, Supply, Installation, testing and Commissioning of Membrane type Surgeon Control Panel( 6 services ) ,mounted flush in the theatre wall alongwith Distribution Board as per the specification Day Time Clock & Elapsed Time clock Peripheral/OT Light Control Temp/ Humdity Controller Medical Gas Alarm Differntial Pressure Indicator Handsfree Telephone etc as per specification and as directed by the Engineer incharge.
2 Plate Dimmable X Ray - Indigenous : Providing, Fixing, Supply, Installation, Testing and Commissioning of Two Plate dimmable X-Ray viewing screen (948mm x 648mm) designed to provide a high level of control luminance without flicker. (Dimming Range 3-100%) etc asper specification and as directed by the Engineer incharge
Hatch Box with Electronic Interlocking and UV Light - Indigenous : Providing, fixing, supply and installation of dirty hatch box made out of SS 304 for dispoasl of dirty linen /waste.Each Hatch will be equipped with two doors and the door will be operated electronically .The Hatch will be designed in such a way that only one door will be opened at one time.The UV light wiil be so installed that it is kept on while both the doors are closed ,this UV light has to be automatically turned off in case of opening of either of the doors. There shall be indicators on both sides of the OT so that door open/close status can be monitored from both ends etc. asper specification and as directed by the Engineer incharge
Peripheral Lights: Recess mounted IP54 protocol, non-hygroscopic peripheral lights for clean room application each set having (2x36 W ) compact flurecent lamps and digital ballast with dimmer control (Suitable for Clean room Class 100 application) etc. asper specification and as directed by the Engineer incharge ( MAKE: ALTOS/ PHILLIPS/ WIPRO )
Single Arm Pendant - Indigenous : Single Arm moveable pendant with 1000mm long arm with Horizontal movements having weight carrying capacity of the arm will not be less than 100 Kgs, one monitor shelf and provision for six electrical sockets 5/15 Amp and gas outletsasper specification and as directed by the Engineer incharge
Distribution Board for Electrical Wiring of Operation Theatre : Providing and Installing of Distribution Board with MCB and ELCB for electrical wiring inside Operation Theatre incuding wiring, sockets and switches etc.asper specification and as directed by the Engineer incharge
OT Light - Indegenous: Supply and Installation of Double Dome LED OT Lights with each dome having capacity of 160000. asper specification and as directed by the Engineer incharge
Semi-Electric OT Table: Supply and Installation of Semi-Electric OT Table made of 304 graded SS with up and down electric operation and other manual.asper specification and as directed by the Engineer incharge
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) as directed by the Engineer incharge
Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete as directed by the Engineer incharge
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides as directed by the Engineer incharge
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.0 mm thickness asper specification and as directed by the Engineer incharge
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.asper specification and as directed by the Engineer incharge
AC UNITS - AHU : Supply, Installation, Testing and Commissioning of Double Skinned Air Handling Units as per specification complete 40mm thick with 0.6mm GI on each side, 40kg/m3 PUF, with Fan section with Backward curved Fans, suitable rated TEFC motor, necessary drive arrangements , coil section with 6 row deep DX cooling coil , filter section with 10 micron pre filters and 5 micron Fine filters with insulated drain pan and all other standard accessories including all necessary supports et as directed by Engineer incharge . Horizontal Ceiling Suspended /Floor Mounted AHU 8.5 TR/ 2800 CFM/ 6 RD/ 125 mm TSP
DX SPLIT OUTDOOR UNITS: Supply Installation, Testing & Comissioning of DX Split Outdoor unit similar to item a with Filter Drier ,Condensing Coil,Expansion device & Connectors having following nominal capacity complete with channel supports, vibration isolators as directed by Engineer incharge ( Make :CARRIER/BLUESTAR/VOLTAS ) 8.5 TR
SHEET METAL WORK : Supply Installation, Testing & Comissioning of Aluminium Ducting for Supply and Return Air AC Ducting ALUMINIUM 0.8mm Etc. as directed by Engineer incharge
Supply Installation, Testing & Comissioning of Aluminium Ducting for Supply and Return Air AC Ducting ALUMINIUM 0.6mmetc. Etc. as directed by Engineer incharge
GRILLERS & DIFFUSERS : SITC of Powder Coated Extruded Aluminium return Air Grill with horizontalfixed bars and end flanges Etc. as directed by Engineer incharge
SITC of Fresh Air arrangements with bird screen and VCD Etc. as directed by Engineer incharge
SITC of Extract Air arrangements with Louvers, back draft dampers and VCD's Etc. as directed by Engineer incharge
VOLUME CONTROL DAMPERS : SITC of Powder Coated Extruded Aluminium Volume Control Dampers complete with flanges, channels & control levers suitable for duct mounting
DUCT THERMAL INSULTION : SITC of Thermal Insulation of ducts using Closed cell Anti Microbial Nitrile Rubber Insulation with recommended Adhesives and sealed with black self adhesive tape of same material ; 9 mm thick Anti Microbial Nitrile Rubber
ACOUSTIC INSULATION: SITC of Acoustic Insulation of ducting using 10mm thick open cell Nitrile Rubber insulation with recommended adhesives and adhesive tape
SITC of Flexible Connection made out of fire resistant flexible double canvas sleeve.
PIPING : Supply ,Installation ,Testing & Commissioning of suitable Hard drawn Copper refrigerant piping with 13mm nitrile rubber insulation for both Suction & Liquid line interconnecting outdoor and indoor unit etc. as directed by Engineer incharge . 8.5 TR SUCTION LINE
Supply ,Installation ,Testing & Commissioning of suitable Hard drawn Copper refrigerant piping with 13mm nitrile rubber insulation for both Suction & Liquid line interconnecting outdoor and indoor unit etc. as directed by Engineer incharge . 8.5 TR LIQUID LINE
Supply,Laying and Fixing of Power and Control cabling between indoor and outdoor units with required specification etc. as directed by Engineer incharge
SITC of PVC drain pipe of required dia with 9mm thick rubber sleeve to the nearest drain point.
Supply, Installation Testing and Commissioning of Duct Inline Exhaust Fans 700cfm, 10mm static.etc.as directed by Engineer incharge
Refrigerant Gas-R410
SITC of Control panel for AHU including bypass switch
Humidity Controller: SITC of electric strip heaters in supply air plenum complete with fixing arrangements, thermostats and safety thermostat including all power and control wiring and required accessories etc.as directed by Engineer incharge .
MEDICAL GAS PIPE LINE
Supply, Installation, Testing and commissioning of Surface mounted front loading Oxygen outlets as per HTM/ EN / NFPA (first and second fix assembly) Etc. as directed by Engineer incharge
Supply, Installation, Testing and commissioning of Surface mounted front loading Air 4 bar outlets as per HTM/ EN / NFPA (first and second fix assembly) Etc. as directed by Engineer incharge
Supply, Installation, Testing and commissioning of Surface mounted front loading double locked Air 7 bar outlets, as per HTM/ EN / NFPA (first and second fix assembly) Etc. as directed by Engineer incharge
Supply, Installation, Testing and commissioning of Surface mounted front loading double locked NITROUS OXIDE outlets, as per HTM/ EN / NFPA (first and second fix assembly) Etc. as directed by Engineer incharge
Supply, Installation, Testing and commissioning of Surface mounted front loading double locked Vacuum out lets, as per HTM/ EN / NFPA (first and second fix assembly) Etc. as directed by Engineer incharge
Supply, Installation, Testing and commissioning of Copper Pipe as per HTM/ EN / NFPA for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. 28 mm OD x 0.9 mm thick etc as directed by Engineer incharge
Supply, Installation, Testing and commissioning of Copper Pipe as per HTM/ EN / NFPA for medical gas services. Pipes shall be priced for all necessary supports, standard fittings 22 mm OD x 0.9 mm thick Etc. as directed by Engineer incharge
Supply, Installation, Testing and commissioning of Copper Pipe as per HTM/ EN / NFPA for medical gas services. Pipes shall be priced for all necessary supports, standard fittings 15 mm OD x 0.9 mm thick etc. as directed by Engineer incharge
PIPELINE DISTRIBUTION SYSTEM Supply, Installation, Testing and commissioning of Isolation Valve assembly as per HTM/ EN / NFPA for medical gas services. All valve should be gas specific.Make: RB/RN/conex 28mm Etc. as directed by Engineer incharge
PIPELINE DISTRIBUTION SYSTEM Supply, Installation, Testing and commissioning of Isolation Valve assembly as per HTM/ EN / NFPA for medical gas services. All valve should be gas specific.Make: RB/RN/conex 22mm etc. as directed by Engineer incharge
Supply and installation of AVSU box (valve boxes) with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover.5 gas services etc. as directed by Engineer incharge
Providing and fixing alarm system for Medical gas ALARM system complete consisting of pressure sensors, panel and the control cabling, all wiring shall be within 1mm sq multi core data cable, PVC pipe for data cable. Panel shall be self contained low voltage (less than 24 V); 5 gas services etc. as directed by Engineer incharge
Supply , Installation and testing of Theater vacuum Unit. It shall be trolley mounted. The unit shall include one regular having gauge and mounted on the trolley stand, having two reusable each 2000 ml plastic collection bottles mounted on the base of trolley unit and connected with regulator & low pressure tube inter-connections etc as directed by Engineer incharge
V GOPI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .