Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2 Cr
EMD Value
₹10 L
Closing Date
16 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Medial Superintendent,
surgical implants P.D.U. Hospital, Rajkot (Part- 1 of 6)
267761
2026-2028
Open
Health
Supply
Rajkot
4 documents required · 2 mandatory · 2 optional
₹15,000
Medical Superintendent, P.D.U. Hospital, Rajkot ( Tender fee common for (Part- 1 of 6) )
₹10 L
23 Jan 2026
23 Jan 2026
23 Jan 2026
16 Feb 2026
23 Jan 2026
## Neuro Implants 1
Sr. No. Item Name Item Specification
1 Cranial Mesh 100 x 100mm -
2 Cranial Mesh 120 x 120mm -
3 Cranial Mesh 120 x 150mm -
4 Cranial Mesh 120 x 180mm -
5 Cranial Mesh 40 x 40mm -
6 Cranial Mesh 60 x 60mm -
7 Cranial Mesh 60 x 80mm -
8 YASARGIL TI TEMP MINI-CLIP STR 7MM FT220T The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
9 YASARGIL TI PERM STD-CLIP STR 7MM FT740T The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
10 YASARGIL TI PERM STD-CLIP STR 9MM FT750T The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
11 YASARGIL TI PERM STD-CLIP STR 11MM FT760T The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
12 YASARGIL TI PERM STD-CLIPSLT-CVD 8.3MM FT752T The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
13 YASARGIL TI PERM STD-CLIPSLT-CVD10.2MM FT762T The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
14 YASARGIL TI PERM STD-CLIP CVD 8MM FT764T The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
15 YASARGIL TI PERM STD-CLIP LAT-ANG 7MM FT746T The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
16 YASARGIL TI PERM STD-CLIP BAYO 7MM FT748T The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
17 YASARGIL TI PERM STD-CLIP BAYO 9MM FT758T The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
18 Yasaragil TI PERM STD-CLIP Fenestrated Forward angle 135 The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
19 Yasaragil TI PERM STD-CLIP Fenestrated Right angle 7MM The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
20 Yasaragil TI PERM STD-CLIP Fenestrated Side angle 135 The aneurysm clip should be made of Titanium alloy Ti6Al4V according to ISO 5832-3 . The clip should ne MRI safe up to 3 Tesla and Aneurysm clip can produce moderate MRI artifacts. Depending on the MR pulse. frequency, the size of the artifacts can vary considerably. The clip should have box lock joint to avoid Scissoring affect. The blade profile should have pyramid like impression. It should be atraumatic. The clip should be supplied in sterile pack. The clip should be colour coded. It should be non-magnetic. All clip applicator should be autoclavable at 134deg. Instruments should meet the International Certification as per DIN EN ISO 13845:2001.
21 Disposable Perforator 11 mm It should be easy to use, like no assembling required and should fix easily to Hudson driver brace., It should have dura-sensor., It should be pre-tested for proper function., It should have thermoform packing which should be sterile and see-through.
22 Disposable Perforator 09 mm It should be easy to use, like no assembling required and should fix easily to Hudson driver brace., It should have dura-sensor., It should be pre-tested for proper function., It should have thermoform packing which should be sterile and see-through.
23 Dural Graft Implant 1"X1" It should have superior handling in wet or dry surface., It should not stick to instruments and gloves., Easily trimmed and applied to the dura., It should be able to placed over other suturable dural substitutes., It should be easily able to stuck under the dura., It should be highly anatomical and should maintain its position well at closure., It should be able maintain its position with stay suturing., It should be fully reabsorbed and get replaced by normal dural tissue., It should to resistant to CSF leakage., It should be made of collagen-based biocampatiable material that exhibits tensile strength. It should also obtained the BSE risk level I., It should be made of collagen-based biocampatiable material that exhibits tensile strength.
24 Dural Graft Implant 1"X3" It should have superior handling in wet or dry surface., It should not stick to instruments and gloves., Easily trimmed and applied to the dura., It should be able to placed over other suturable dural substitutes., It should be easily able to stuck under the dura., It should be highly anatomical and should maintain its position well at closure., It should be able maintain its position with stay suturing., It should be fully reabsorbed and get replaced by normal dural tissue., It should to resistant to CSF leakage., It should also obtained the BSE risk level I.
25 Dural Graft Implant 2"X2" It should have superior handling in wet or dry surface., It should not stick to instruments and gloves., Easily trimmed and applied to the dura., It should be able to placed over other suturable dural substitutes., It should be easily able to stuck under the dura., It should be highly anatomical and should maintain its position well at closure., It should be able maintain its position with stay suturing., It should be fully reabsorbed and get replaced by normal dural tissue., It should to resistant to CSF leakage., It should be made of collagen-based biocampatiable material that exhibits tensile strength., It should also obtained the BSE risk level I.
26 Dural Graft Implant 3"X3" It should have superior handling in wet or dry surface., It should not stick to instruments and gloves., Easily trimmed and applied to the dura., It should be able to placed over other suturable dural substitutes., It should be easily able to stuck under the dura., It should be highly anatomical and should maintain its position well at closure., It should be able maintain its position with stay suturing., It should be fully reabsorbed and get replaced by normal dural tissue., It should to resistant to CSF leakage., It should be made of collagen-based biocampatiable material that exhibits tensile strength., It should also obtained the BSE risk level I.
27 Dural Graft Implant 4"X5" It should have superior handling in wet or dry surface., It should not stick to instruments and gloves., Easily trimmed and applied to the dura., It should be able to placed over other suturable dural substitutes., It should be easily able to stuck under the dura., It should be highly anatomical and should maintain its position well at closure., It should be able maintain its position with stay suturing., It should be fully reabsorbed and get replaced by normal dural tissue., It should to resistant to CSF leakage., It should be made of collagen-based biocampatiable material that exhibits tensile strength., It should also obtained the BSE risk level I.
28 Intracranial Pressure Monitoring System cable Intracranial Pressure Monitoring System Transducer cable
29 Intracranial Pressure Monitoring System Parenchymal sensor The catheter should be inbuilt with micro sensor and ventricular catheter for the drainage of the CSF and monitor ICP at the same time., It should have 38cm clear ventricular catheter with preloaded stylet., The transducer should consists of a miniature strain gauge pressure sensor mounted in a titanium case at the tip of a 100cm flexiblenylon tube., It should come with 7-guage tunneling trocar for placement., The information should be relayed electronically rather than hydrostatic or fiberoptics., It should be made of strain gauge mechanism, It should have high fidelity of greater than 10000Hz to facilitate excellent wave form analysis., The drift in ICP over 9 days period should be maximum of 1mmhg or less., The system should be capable of monitoring Parenchymal ICP., The drift in ICP over 9 days period should be maximum of 1mmhg or less., The system should be capable of monitoring Subdural ICP.
30 Intracranial Pressure Monitoring System Subdural sensor The catheter should be inbuilt with micro sensor and ventricular catheter for the drainage of the CSF and monitor ICP at the same time., It should have 38cm clear ventricular catheter with preloaded stylet., The transducer should consists of a miniature strain gauge pressure sensor mounted in a titanium case at the tip of a 100cm flexible nylon tube., It should come with 7-guage tunneling trocar for placement., The information should be relayed electronically rather than hydrostatic or fiberoptics., It should be made of strain gauge mechanism, It should have high fidelity of greater than 10000Hz to facilitate excellent wave form analysis.
31 Intracranial Pressure Monitoring System Ventricular sensor The catheter should be inbuilt with micro sensor and ventricular catheter for the drainage of the CSF and monitor ICP at the same time., It should have 38cm clear ventricular catheter with preloaded stylet., The transducer should consists of a miniature strain gauge pressure sensor mounted in a titanium case at the tip of a 100cm flexible nylon tube., It should come with 7-guage tunneling trocar for placement., The information should be relayed electronically rather than hydrostatic or fiberoptics., It should be made of strain gauge mechanism, It should have high fidelity of greater than 10000Hz to facilitate excellent wave form analysis., The drift in ICP over 9 days period should be maximum of 1mmhg or less., The system should be capable of monitoring Ventricular ICP.
32 Antimicrobial Impregnated Low Pressure Shunt The Shunt catheters should impregnated by patented Advanced Impregnation Process (AIP) throughout the silicone matrix., It’s should have a combination of powerful antibiotics – 0.15percent Clindamycin and .054percent Rifampicin., The anti-microbial should help in preventing bacterial colonization on inner lumen and exterior catheter wall.
33 Antimicrobial Impregnated Medium Pressure Shunt The Shunt catheters should impregnated by patented Advanced Impregnation Process (AIP) throughout the silicone matrix., It’s should have a combination of powerful antibiotics – 0.15percent Clindamycin and .054percent Rifampicin., The anti-microbial should help in preventing bacterial colonization on inner lumen and exterior catheter wall.
34 Antimicrobial Impregnated High Pressure Shunt The Shunt catheters should impregnated by patented Advanced Impregnation Process (AIP) throughout the silicone matrix., It’s should have a combination of powerful antibiotics – 0.15percent Clindamycin and .054percent Rifampicin., The anti-microbial should help in preventing bacterial colonization on inner lumen and exterior catheter wall.
35 Disposable Raney Scalp Clip scalp clips; box of 100
36 Raney Scalp Clip applicator applicator for scalp clips
37 Intracranial Pressure Monitoring system Display Unit Stand alone Monitor should display mean Systolic and Diastolic Intra cranial Pressure as Digital Display; the display should be as Digital Data rather than through Hydrostatic Column or Fibreoptics with one touch zero function for disposable transducers; it has user friendly setings for Alarm Function with battery back-up facility for 2-3 hours. should be used for both Adult and Paediatric CSF pressure monitoring
38 Intracranial Pressure Monitoring system with Direct link Stand alone Monitor should display mean Systolic and Diastolic Intra cranial Pressure as Digital Display; the display should be as Digital Data rather than through Hydrostatic Column or Fibreoptics with one touch zero function for disposable transducers; it has user friendly setings for Alarm Function with battery back-up facility for 2-3 hours. should be used for both Adult and Paediatric CSF pressure monitoring
39 Disposable Cable For Isocool Active Heat Transfer Bipolar Forceps Bipolar forceps cable to be used with isocool forceps and tip which is specially designed for Neuro surgery procedures which requires critical and precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage
40 Isocool Active Heat Transfer Bipolar Forceps Bipolar forceps specially designed for isocool golden tips which is designed for critical surgery procedures which requires critical and precise temperature control to reduce sticking and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
41 Isocool Active Heat Transfer Bipolar Tip Size1mm, Total length 10.5", working length 4.5" Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
42 Isocool Active Heat Transfer Bipolar Tip Size1mm, Total length 8.5", working length 3.5" Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
43 Isocool Active Heat Transfer Bipolar Tip Size1mm, Total length 10.5", working length 4.5" Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
44 Isocool Active Heat Transfer Bipolar Tip Size1mm, Total length 9.5", working length 4.5" Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
45 Isocool Active Heat Transfer Bipolar Tip Size2mm, Total length 8.5", working length 3.5" Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
46 Isocool Active Heat Transfer Bipolar Tip Size2mm, Total length 9.5", working length 4.5" Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
47 Isocool Bipolae Forcep Handls Bipolar forceps handle specially designed for critical surgery procedures which are designed for precise temperature control to reduce sticking and charring for Minimum peripheral tissue damage; should be use with ISO Cool bipolar golden tips
48 Isocool Active Heat Transfer Bipolar Tip Size5mm, Total length 8.5", working length 3.5" Bipolar forceps Tip specially designed for critical surgery procedures which requires precise temperature control to reduce stickng and charring for Minimum peripheral tissue damage with Active Heat Transfer technology where the heat dispersed beyond tips of the forceps
49 Intracranial Pressure Monitoring System Parenchymal sensor with Scull bolt The catheter should be inbuilt with micro sensor and ventricular catheter for the drainage of the CSF and monitor ICP at the same time., It should have 38cm clear ventricular catheter with preloaded stylet., The transducer should consists of a miniature strain gauge pressure sensor mounted in a titanium case at the tip of a 100cm flexiblenylon tube., It should come with 7-guage tunneling trocar for placement., The information should be relayed electronically rather than hydrostatic or fiberoptics., It should be made of strain gauge mechanism, It should have high fidelity of greater than 10000Hz to facilitate excellent wave form analysis., The drift in ICP over 9 days period should be maximum of 1mmhg or less., The system should be capable of monitoring Parenchymal ICP., The drift in ICP over 9 days period should be maximum of 1mmhg or less., The system should be capable of monitoring Subdural ICP. It should be available with Scull bolt to reduce the movement of implanted sensor
50 Intracranial Pressure Monitoring System Subdural sensor with Scull bot The catheter should be inbuilt with micro sensor and ventricular catheter for the drainage of the CSF and monitor ICP at the same time., It should have 38cm clear ventricular catheter with preloaded stylet., The transducer should consists of a miniature strain gauge pressure sensor mounted in a titanium case at the tip of a 100cm flexible nylon tube., It should come with 7-guage tunneling trocar for placement., The information should be relayed electronically rather than hydrostatic or fiberoptics., It should be made of strain gauge mechanism, It should have high fidelity of greater than 10000Hz to facilitate excellent wave form analysis. It should be available with Scull bolt to reduce the movement of implanted sensor
## Neuro Implants 2
Sr. No. Item Name Item Specification
51 Vetriculo Peritoneal Medium Pressure shunt with antibiotic impregnated ventricular and petonial catheter Impregnated with Rifampicin and Clindamycin to avoid infection for 28 days
52 Vetriculo Peritoneal Low Pressure shunt with antibiotic impregnated ventricular and petonial catheter Impregnated with Rifampicin and Clindamycin to avoid infection for 28 days
53 Self Tapping Screw Size : 1.6 x 3mm 3 mm titanium screws
54 Self Tapping Screw Size : 1.6 x 4mm 4 mm titanium screws
55 Self Tapping Screw Size : 1.6 x 5mm 5 mm titanium screws
56 Screw Driver Handle with Screw Driver Bit. -
57 Self drilling Screw Size : 1.6 x 3mm 3 mm titanium screws
58 Self drilling Screw Size : 1.6 x 4mm 4 mm titanium screws
59 Self drilling Screw Size : 1.6 x 5mm 5 mm titanium screws
60 Self drilling Screw Size : 1.6 x 6mm 6 mm titanium screws
61 Cranial-Plate 1.6 straight w/centre-space 2 2 Hole Titanium Plate
62 Cranial-Plate 1.6 straight w/centre-space 4 4 Hole Titanium Plate
63 Adapt Plate 1.6 20ho thick0.5 Ti 20 Hole Plate
64 Mesh-Pl 1.6 38*45 thickness 0.4 contourable T Small Mesh
65 Mesh-Pl 1.6 100*100 thickness 0.6 contourable Big Mesh
66 X-Plate-1.6 4ho thick0.5 Ti x shape titanium plate with 4 holes and 0.5mm thickness
67 Self Tapping Screw Size : 1.6 x 3mm 3 mm SS screws
68 Self Tapping Screw Size : 1.6 x 4mm 4 mm SS screws
69 Self Tapping Screw Size : 1.6 x 5mm 5 mm SS screws
70 Screw Driver Handle with Screw Driver Bit. 1mm,1.5mm,2mm,2.5mm
71 Self drilling Screw Size : 1.6 x 3mm 3 mm SS screws
72 Self drilling Screw Size : 1.6 x 4mm 4 mm SS screws
73 Self drilling Screw Size : 1.6 x 5mm 5 mm SS screws
74 Self drilling Screw Size : 1.6 x 6mm 6 mm SS screws
75 Cranial-Pl 1.6 straight w/centre-space 2 2 Hole SS Plate
76 Cranial-Pl 1.6 straight w/centre-space 4 4 Hole SS Plate
77 A all human protien, bovine free sealant with double viral inactivation/removal process, should have two package system - fibronectin,plasminogen. thrombin, application device. Should come with triple lumen applicator device, should come in both dip or spray with NA
78 A synthetic formulation containing 75percentage 2-octyl cyanoacrylate, 25percentage butyl lactolyl cyanoacrylate with no animal or human derivatives, should completely polymerise in with 2 mins, should come in applicator form. The sealant should form a flexible film and bo NA
79 Abso Mops plyboth sides non- woven radio opeque 8" x 8"
80 Abso. gelating spong BP Size-80x50x10mm pkt.pkt of 2 NA
81 absorbable gelatin sponge, sterile, fda approved NA
82 Absorrable gelatin powder, 1gm in sterile bottle without NA
83 Adson Bayonet Shaped Dissection Forceps, serrated, 8" length
84 Adson Bayonet Shaped Dissection Forceps, serrated, 1x2 teeth 8" length
85 ADSON cerebellar retractors, self retaining Total Opening: 4 1/2" (114mm),4X4 blunt prongs, straight shaft Blade Width: 5/8" ,Blade Depth: 7/8" ,Length: 7 1/2"
86 ADSON cerebellar retractors, self retaining Total Opening: 4 1/2" (114mm),4X4 sharp prongs, straight shaft Blade Width: 5/8" ,Blade Depth: 7/8" ,Length: 7 1/2"
87 adson cranial rongeur single action, angular jaw 7mm, 8" long
88 Adson Rectangular dural Hook sharp, fine, 8 in.
89 Adson Rectangular dural Hook blunt, fine, 8 in.
90 Adson Skull Drill-guide and Brain- protection Forceps, NA
91 Adson's Dissecting forceph bayonet 1x2 teeth NA
92 Adson's Dissecting forceph bayonet serrated 191 mm length
93 Adson's Dural Forceps fine 1x2 teeth 127mm length
94 Adson's Dural Forceps fine micro tip 127 mm length
95 Adson's Hypophyseal forceps bayonet with cup jaws serrated 229mm length
96 Adson's Hypophyseal forceps bayonet with cup jaws serrated 229mm length
97 Adson's Periosteal Elevator curved 5mm width 165mm length
98 Adson's Periosteal Elevator curved 7mm width 165mm length
99 Adson's Periosteal Elevator curved 10mm wide 165mm length
100 Adson's Periosteal Elevator straight 5mm width 191mm length
## Neuro Implants 3
Sr. No. Item Name Item Specification
101 Air Metress All Size NA
102 Aneurysm Clip applicator round handle ,flexible, with rotation, bayonet NA
103 Aneurysm Clip applicator round handle ,rigid, without rotation, bayonet NA
104 AUSTIN, Micro Suture Tying Forceps Tips 0,8 mm 140 mm,
105 B.P. handle no. 4
106 B.P. handle no. 7 long
107 B.P. handle no.3 long
108 B.P. handle no. 4 long
109 B.P. handle no. 4 long angled
110 B.P. handle no. 3 long angled
111 B.P. handle no. 4 round handle
112 B.P. handle no. 3round handle
113 Bayonet Probe, teardrop tip:3mm, 15° Angle Whole Length :205.5mm Working Length :98mm NA
114 Bayonet Probe, teardrop tip:3mm, 45° Angle Whole Length : 202.5mm Working Length :97.5mm NA
115 Bayonet Probe, teardrop tip:3mm, 80° Angle Whole Length :203.5mm Working Length :100.5mm NA
116 Bayonet Probe, teardrop tip:3mm, straight Whole Length :203mm Working Length :98mm NA
117 Bayonet Probe, teardrop tip:3mm, straight Whole Length :219mm Working Length :114mm NA
118 BIEMER, Vessel Spreader 160 mm, 6 1/4" NA
119 Bipolar cord, reuseable, 3m, NA
120 Bipolar Forceps, non stick, insulated, Baonet specification attached as doc file 12"
121 Bipolar Forceps, non stick, insulated, Baonet specification attached as doc file 4"
122 Bipolar Forceps, non stick, insulated, Baonet specification attached as doc file 7"
123 Bipolar Forceps, non stick, insulated, Baonet specification attached as doc file 7" tip: 0.25mm
124 Bipolar Forceps, non stick, insulated, Baonet tip down specification attached as doc file 7" tip: 0.25mm
125 Bipolar Forceps, non stick, insulated, Baonet tip up specification attached as doc file 7' tip: 0.25mm
126 Bipolar Forceps, non stick, insulated, Baonet, with irrigation specification attached as doc file 7"
127 Bipolar Forceps, non stick, insulated, straight specification attached as doc file 4"
128 Bipolar Forceps, non stick, insulated, straight specification attached as doc file 7"
129 Bipolar Forceps, non stick, insulated, straight specification attached as doc file 7", tip: 0.25mm
130 bone curette angled down, 81/2" long hollow handle size 1
131 bone curette angled down, 81/2" long hollow handle size 2
132 bone curette angled down, 81/2" long hollow handle size 3
133 bone curette angled down, 81/2" long hollow handle size 5
134 bone curette angled down, 81/2" long hollow handle size 6
135 bone curette angled down, 81/2" long hollow handle size 8
136 bone curette bayonet shape, 250mm length size 1
137 bone curette bayonet shape, 250mm length size 2
138 bone curette bayonet shape, 250mm length size 4
139 bone curette bayonet shape, 250mm length size 6
140 bone curette bayonet shape, 250mm length size 8
141 bone curette straight, 81/2" long hollow handle size 1
142 bone curette straight, 81/2" long hollow handle size 2
143 bone curette straight, 81/2" long hollow handle size 3
144 bone curette straight, 81/2" long hollow handle size 4
145 bone curette straight, 81/2" long hollow handle size 5
146 bone curette straight, 81/2" long hollow handle size 6
147 bone curette straight, 81/2" long hollow handle size 7
148 bone curette straight, 81/2" long hollow handle size 8
149 bozeman Needle HolderTungsten carbide jaws,gold plated bows box joint 7" length
150 bozeman Needle HolderTungsten carbide jaws,gold plated bows box joint 8'' length
## Neuro Implants 4
Sr. No. Item Name Item Specification
151 brain spatula flat malleable, uniform width, 8" long 6mm wide
152 brain spatula flat malleable, uniform width, 8" long 8mm wide
153 brain spatula flat malleable, uniform width, 8" long 10mm wide
154 brain spatula flat malleable, uniform width, 8" long 12mm wide
155 brain spatula flat malleable, uniform width, 8" long 14mm wide
156 brain spatula flat malleable, uniform width, 8" long 16mm wide
157 brain spatula flat malleable, uniform width, 8" long 18mm wide
158 brain spatula flat malleable, uniform width, 8" long 20mm wide
159 brain spatula flat malleable, uniform width, 8" long 22mm wide
160 brain spatula flat malleable, uniform width, 8" long 25mm wide
161 Bruening modified VPS septum forceps in crocodile action with large mouth opening, 190mm, 7 1/2" (four size) NA
162 bull dog clamp curved jaw jaw 25mm,
163 bull dog clamp curved jaw jaw 35mm,
164 bull dog clamp straight jaw jaw 25mm,
165 bull dog clamp straight jaw jaw 35mm,
166 bur hole protection forcep 8" length
167 Cairns artery forceps, straight, box-joint, 146mm (5 ¾”)
168 CASPAR Curette, toothed, 250mm, 10", 5mm NA
169 CASPAR Type retractor, 240mm, 9 ½” 10mm wide
170 CASPAR Type retractor, 240mm, 9 ½” 6mm wide
171 CASPAR Type retractor, 240mm, 9 ½” 8mm wide,
172 CASTROVIEJO, Micro Needle Holder with catch curved 145 mm, 5 3/4"
173 CASTROVIEJO, Micro Needle Holder with catch straight 145 mm, 5 3/4"
174 CLOWARD Depth Gauge Length 8 3/8” (213mm) NA
175 CLOWARD Lamina Spreader, 6 1/4", Blade opening 18 mm NA
176 CLOWARD Lumbar Lamina Spreader 1, Arm length 3 1/2" (89mm), Total Opening 2 1/8" (53 mm) NA
177 CLOWARD Lumbar Lamina Spreader 2, Arm length 4 1/4" (108 mm), Total Opening 2 1/8" (53 mm) NA
178 cloward vertebral spreader with rachet,total opening 11/2" casper vertebral body distractor with pins & drill guide NA
179 clowards cervical retracto rwith single hing arm 10" long with set of 8 blades of blunt & sharp 4 prongs NA
180 Cobb Spinal Elevator Lenght 279 mm each 13MM
181 Cobb Spinal Elevator Lenght 279 mm each 19 MM
182 Cobb Spinal Elevator Lenght 279 mm each WIDTH 10 MM
183 collagen sponge, sterile NA
184 Cone Hami-Laminectomy Retractor, hinged arms, 254 mm. (10 in.) NA
185 Cone Hemi-Laminectorny Retractor, hinged arms, 165 mm. (6 ½ in.) NA
186 Cone Laminectomy retractor, hinged arms, 3 x 4 prong blades, (8”) with ratchet NA
187 Cone Laminectomy retractor, hinged arms, 3 x 4 prongs, 254mm (10”) NA
188 Cone retractor, hinged arms, 3 x 4 prong blades, (8”) with ratchet.
189 Cone retractor, hinged arms, 3 x 4 prong blades, 10' with cam grip rack
190 Cone retractor, hinged arms, 3 x 4 prong blades, (6”) with ratchet.
191 Cone retractor, self-retaining with hinged arms, 165mm (6 ½”).
192 Cone Skull punch adult size Shaft 210mm,for skull thickness 12mm
193 Cone Ventricular Drainage Cannula with Stilette Nickel, Silver gift with two lateral eye's graduated in cm 8.9mm to Shoulder. 18 swg
194 Cone Ventricular Drainage Cannula with Stilette Nickel, Silver gift with two lateral eye's graduated in cm 8.9mm to Shoulder. 16 swg
195 Cone Ventricular Drainage Cannula with Stilette Nickel, Silver gift with two lateral eye's graduated in cm 8.9mm to Shoulder. 14 swg
196 Cottle dissector, 200mm, 8" NA
197 Cottle osteotomes, with depth markings, 180mm, 7", 4 mm wide, 7 mm wide, 9 mm wide, 12 mm wide NA
198 COTTLE, Mallet with flat and round end; 8 1/4 oz. 180 mm, 7" NA
199 cranial perforator drill for standard adult skull 3mm thick 14/11mm
200 cranial perforator drill for standard adult skull 3mm thick 13/9mm
## Neuro Implants 5
Sr. No. Item Name Item Specification
201 cranial perforator drill for standard adult skull 3mm thick 7/3.5mm
202 craniotomy set all instruments should be CE approved B.P. handle no. 3
203 Crile wood Needle HolderTungsten carbide jaws,gold plated bows box joint 8'' length For 3-0 to 6-0 sutures
204 Crile wood Needle HolderTungsten carbide jaws,gold plated bows box jointv 6'' length For 3-0 to 6-0 sutures
205 Crutchfield brace with bevel grer chromium plated Shaft Length 203mm
206 Crutchfield guarded drill to fit any drill 3mm deep
207 Crutchfield guarded drill to fit any drill 4mm deep
208 Crutchfield skull traction tong large
209 Crutchfield skull traction tong small
210 Cup Curette 1.0 mm x 1.5mm Angle Up Whole Length: 194.5mm Working Length: 109.5mm NA
211 Cup Curette 1.5 mm x 2.0mm Angle Up Whole Length: 195.5mm Working Length: 110.5mm NA
212 Cushing Artery Forceps,box- joint, curved-to-side, fine serrated jaws 146 mm. (5 3/4 in.)
213 Cushing silver clips mounted on pvc holder Large
214 Cushing silver clips mounted on pvc holder Medium
215 Cushing Type Elevators, sharp, wide Rounded edge, Blade 5/8”(16mm),width Length 7 ¼”,
216 Cushing Type Elevators, sharp, wide square edge, Blade 5/8”(16mm),width Length 7 ¼”,
217 CUSHING-LANDOLT, Specula For, Transsphenoidal hypophysectomy, , 90x15mm, NA
218 DANDY Scalp Hemostatic Forceps curved on side, 5 1/2" (140mm), serrated
219 DANDY Scalp Hemostatic Forceps curved on side, 5 1/2" (140mm), 1x2 teeth
220 DANDY Scalp Hemostatic Forceps curved on side, 412" (120mm) serrated
221 dass trephine, sharp centre pin,dura guard 35 mm
222 dass trephine, sharp centre pin,dura guard 50mm
223 dass trephine, sharp centre pin,dura guard 75mm
224 De Vilbiss Skull channeling forceps with spare blade 225mm Lenght
225 Debakey with 3 pairs of blades (30 x 30mm, 40 x 40mm, 50 x 50mm), NA
226 diamond rossen burr long 1.5mm dia
227 diamond rossen burr long 2.5mm dia
228 diamond rossen burr long 2mm dia
229 diamond rossen burr long 3.5mm dia
230 diamond rossen burr long 3mm dia
231 Dissecting suction tube, fiat, 5 mm wide, sharp 200 mm, 8" NA
232 Dissector, sharp, 2.4mm Sharp: slightly cvd Whole Length :190mm Working Length :90mm NA
233 Dissector, sharp, 3.5mm Slightly cvd.Whole Length :190mm Working Length :90mm NA
234 Dissector, sharp, 5mm Slightly cvd. Whole Length :190mm Working Length :90mm NA
235 DOYEN, for adults, 240 mm, 9 ½”, rib raspatories. Right and Left each NA
236 DOYEN, for children, 180 mm, 7", rib Raspatories NA
237 dura patch 10x12cm
238 dura patch 15x20cm
239 dura patch 8x10cm
240 Duraform 1x1 sponge NA
241 Duraform 1x3 sponge NA
242 Duraform 2x2 sponge NA
243 Duraform 3x3 sponge NA
244 Duraform 3x5 sponge NA
245 Dural Scessors straight rounded ends 203mm length
246 Extension Piece to use with Hudson brace 125mm (5")
247 external c.s.f collection bag N.A.
248 external c.s.f drainage kit adult
249 external c.s.f drainage kit child
250 external c.s.f drainage kit infants
## Neuro Implants 6
Sr. No. Item Name Item Specification
251 external lumbar drainage kit adult
252 external lumbar drainage kit child
253 external lumbar drainage kit infants
254 FERRIS-SMITH-KERRISON 1mm pituitary punch, 180mm, 40 Deg. Upward cutting.
255 FERRIS-SMITH-KERRISON 2mm pituitary punch, 180mm, 40 Deg. Upward cutting
256 FERRIS-SMITH-KERRISON 3mm pituitary punch, 180mm, 40 Deg. Upward cutting
257 FERRIS-SMITH-KERRISON 4mm pituitary punch, 180mm, 40 Deg. Upward cutting
258 FERRIS-SMITH-KERRISON 5mm pituitary punch, 180mm, 40 Deg. Upward cutting
259 FERRIS-SMITH-KERRISON pituitary punch, 180mm, 7", 45 Deg. Downward cutting 1mm.
260 FERRIS-SMITH-KERRISON pituitary punch, 180mm, 7", 45 Deg. Downward cutting 2mm.
261 FERRIS-SMITH-KERRISON pituitary punch, 180mm, 7", 45 Deg. Downward cutting 3mm
262 FERRIS-SMITH-KERRISON pituitary punch, 180mm, 7", 45 Deg. Downward cutting 4mm
263 FERRIS-SMITH-KERRISON pituitary punch, 180mm, 7", 45 Deg. Downward cutting 5mm
264 FERRIS-SMITH-KERRISON pituitary punch, 180mm, 7", 90 Deg downwards cutting 2mm
265 FERRIS-SMITH-KERRISON pituitary punch, 180mm, 7", 90 Deg downwards cutting 3mm
266 FERRIS-SMITH-KERRISON pituitary punch, 180mm, 7", 90 Deg downwards cutting 5mm
267 FISCH, Sharp Hook 90°. Angled, 185 mm, 71/4" NA
268 fish grasping forcep squeeze handle NA
269 fish micro scissor squeeze handle NA
270 fish neurectomy scissor squeeze handle NA
271 forcep tissue boney 1x2 teeth 7" length
272 forcep tissue boney 2x3 teeth 7" length
273 forcep, debakey, micro tip 1.5mm 6'' length
274 forcep, debakey, micro tip 1.5mm 8" length
275 forcep, tungsten carbide tipped 6'' length
276 forcep, tungsten carbide tipped 8" length
277 forceps gemini right angled 6'' length
278 forceps gemini right angled 8" length
279 forceps gemini right angled 10" length
280 forceps mini-gemini right angled 6'' length
281 forceps mini-gemini right angled 8" length
282 forceps mini-gemini right angled 10" length
283 forceps, gillies serrated tip fine 8" length
284 forceps, gillies toothed tip fine 1x2 8" length
285 FORCEPS, LIGHT PATTERNS, FINE TIPS, 0.5mm,7 1/4"
286 Formalin Chamber 50x20x30cm NA
287 FRYKHOLM, bone Rongeur. 230 mm, 9",
288 GIERTZ-STILLE rib shears, 250 mm, 10" NA
289 Gigli Saw guide & Protator malleable 305mm length each 4 MM
290 Gigli Saw guide & Protator malleable 305mm length each 6 MM
291 Gigli Saw handle (pair of 2) 54mm
292 Gigli Saw wires double strand 50 cm Length
293 greenberg tapered brain spatula 9' long 6mm x 19mm
294 greenberg tapered brain spatula 9' long 4mm x 16mm
295 greenberg tapered brain spatula 9' long 3mm x 112mm
296 greenberg tapered brain spatula 9' long 2.5mm x 10mm
297 greenberg tapered brain spatula 9' long 1.5mm x 6mm
298 HARDY Curette, malleable, 260 mm, 10 ¼”, Ø 6mm NA
299 HARDY Curette, malleable, 260 mm, 10 1/4" Ø 4 mm NA
300 Hardy Curettes, bayonet. Working Distance 4 3/4" (120mm), Total Length: 9 1/2" (241mm), Type: 45 degree right, Tip Width: 3mm NA
## Neuro Implants 7
Sr. No. Item Name Item Specification
301 Hardy Curettes, bayonet. Working Distance 4 3/4" (120mm), Total Length: 9 1/2" (241mm), Type: 45 degree right, Tip Width: 5mm NA
302 Hardy Curettes, bayonet. Working Distance 4 3/4" (120mm), Total Length: 9 1/2" (241mm), Type: 90 degree left, Tip Width: 3mm NA
303 Hardy Curettes, bayonet. Working Distance 4 3/4" (120mm), Total Length: 9 1/2" (241mm), Type: 90 degree left, Tip Width: 5mm NA
304 Hardy Curettes, bayonet. Working Distance 4 3/4" (120mm), Total Length: 9 1/2" (241mm), Type: Angled Down, Tip Width: 3mm NA
305 Hardy Curettes, bayonet. Working Distance 4 3/4" (120mm), Total Length: 9 1/2" (241mm), Type: Angled Down, Tip Width: 5mm NA
306 Hardy Curettes, bayonet. Working Distance 4 3/4" (120mm), Total Length: 9 1/2" (241mm), Type: Angled up, Tip Width: 3mm NA
307 Hardy Curettes, bayonet. Working Distance 4 3/4" (120mm), Total Length: 9 1/2" (241mm), Type: Angled up, Tip Width: 5mm NA
308 Hardy Curettes, bayonet. Working Distance 4 3/4" (120mm), Total Length: 9 1/2" (241mm), Type: curved left, Tip Width: 5mm NA
309 Hardy Curettes, bayonet. Working Distance 4 3/4" (120mm), Total Length: 9 1/2" (241mm), Type: curved right, Tip Width: 5mm NA
310 Hardy dissectors sharpened, inner edge 245mm, 9 3/4", left. NA
311 Hardy dissectors sharpened, inner edge 245mm, 9 3/4", right. NA
312 Hardy implant fork, 245mm, 9 3/4" NA
313 Hardy, Enucleators, blunt, 245 mm, 9 3/4", Right NA
314 Hardy-Fahlbusch, dissector sharpened inner edge 245mm, 9 3/4" left. NA
315 Hardy-Fahlbusch, dissector sharpened inner edge 245mm, 9 3/4" right. NA
316 hegar - olsen combined neddle holder and scissors tungston carbide 6'' length
317 hegar - olsen combined neddle holder and scissors tungston carbide 7" length
318 heifetz brain spatula, mounted on 3mm rod,155mm length 8mm wide
319 heifetz brain spatula, mounted on 3mm rod,155mm length 11mm wide
320 heifetz brain spatula, mounted on 3mm rod,155mm length 14mm wide
321 heifetz brain spatula, mounted on 3mm rod,155mm length 17mm wide
322 HEIFETZ, Vessel Spreader 100 mm, 4" NA
323 high pressure V.P.SHUNT adult
324 high pressure V.P.SHUNT child
325 high pressure V.P.SHUNT infants
326 Hudson Brace Stainless steel Made of non- rusted stainless steel ,screw tightening
327 Hudson Brace Stainless steel Made of non- rusted stainless steel ,Snap chuck system
328 Hudson conical burr hard edge standard brace fitting Length 92mm (3 3/4") for each Diameter 9mm 11mm,13mm,16mm,20mm
329 Hudson conical burr hard in Titanium Nitrate,Golden Or Black finish fitting Length 92mm (3 3/4") for each Diameter 9mm 11mm,13mm,16mm,20mm
330 Hudson Perforator Hard edge original model,Standard brace fitting Length 108mm (4 1/4") for each Width 10mm,12mm, 15mm,17mm,20mm
331 Hudson Perforator Hard edge original model,Standard brace fitting Standard brace fitting Length 108mm (4 1/4") for each Width 10mm,12mm, 15mm,17mm,20mm
332 INSTRUMENTS FOR CEREBELLAR PONTINE ANGLE TUMOR OPERATIONS ,SAMII Knives for tumor tissue 200 mm, 9" 1,0 mm
333 INSTRUMENTS FOR CEREBELLAR PONTINE ANGLE TUMOR OPERATIONS ,SAMII Knives for tumor tissue 200 mm, 9" 1,5 mm
334 INSTRUMENTS FOR CEREBELLAR PONTINE ANGLE TUMOR OPERATIONS ,SAMII Knives for tumor tissue 200 mm, 9" 2,0 mm
335 INSTRUMENTS FOR CEREBELLAR PONTINE ANGLE TUMOR OPERATIONS ,SAMII Knives for tumor tissue 200 mm, 9" 2,5 mm
336 INSTRUMENTS FOR CEREBELLAR PONTINE ANGLE TUMOR OPERATIONS ,SAMII Knives for tumor tissue 200 mm, 9" 3,0 mm
337 INSTRUMENTS FOR CEREBELLAR PONTINE ANGLE TUMOR OPERATIONS ,SAMII Knives for tumor tissue 200 mm, 9" 3,5 mm
338 INSTRUMENTS FOR CEREBELLAR PONTINE ANGLE TUMOR OPERATIONS ,SAMII Knives for tumor tissue 200 mm, 9" 4,0 mm
339 INSTRUMENTS FOR CEREBELLAR PONTINE ANGLE TUMOR OPERATIONS ,SAMII Knives for tumor tissue 200 mm, 9" 5,0 mm
340 intervertebral disc biopsy forcep down 2mm x 10 mm
341 intervertebral disc biopsy forcep left 2mm x 10 mm
342 intervertebral disc biopsy forcep right 2mm x 10 mm
343 intervertebral disc biopsy forcep straight 1mm x 10 mm
344 intervertebral disc biopsy forcep straight 2mm x 10 mm
345 intervertebral disc biopsy forcep straight 3mm x 10 mm
346 intervertebral disc biopsy forcep straight 4mm x 10 mm
347 intervertebral disc biopsy forcep up 2mm x 10 mm
348 JACOBSON probe with ball tip 185mm, 7 1/4" DIA 1mm
349 JACOBSON probe with ball tip 185mm, 7 1/4" DIA 1.5mm
350 JACOBSON, Micro Needle Holder straight, without catch 185 mm, 7 1/4"
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SURGICAL IMPLANTS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .