| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 CrAccepted-AOC JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | ₹23.2 Cr Quoted ₹23.4 Cr | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹25.0 CrRejected-Finance NO 2 GF AKSHAYRAJ APARTMENT JUBILEE CIRCLE BHUJ 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | ₹25.0 Cr | L2 | Rejected-Finance Not being lowest tenderer |
| 3 | L3₹28.3 CrRejected-Finance | ₹28.3 Cr | L3 | Rejected-Finance Not being lowest tenderer |
| 4 | L4₹30.3 CrRejected-Finance SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | ₹30.3 Cr | L4 | Rejected-Finance Not being lowest tenderer |
| 5 | L5₹31.3 CrRejected-Finance NOT SPECIFIED | ₹31.3 Cr | L5 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹21.7 Cr
EMD Value
₹14.1 L
Closing Date
29 Dec 2023, 6:00 pmClosed
CE (AF) GANDHINAGAR
Chief Engineer (Air Force) Lekhawada Patia, Chiloda PO CRPF Campus, Gandhinagar - 382042
COMPLETION OF INCOMPLETE WORK AND CERTAIN ADDITIONAL WORK FOR MODIFICATION OF FOUR DOUBLE ENTRY BLAST PENS AT AF STN JAMNAGAR (RISK AND COST)
2023_MES_630848_1
86255 RISK AND COST
Open Tender
Civil Works
545 days
GE (AF) JAMNAGAR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹3,000
Yes
₹14.1 L
Yes
8 Feb 2024
2 Dec 2023
30 Dec 2023
2 Dec 2023
29 Dec 2023
23 Dec 2023
3 Dec 2023 - 15 Dec 2023
Amount
Excavating in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth, for foundation, etc or manholes n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in hard/dense all as specified and as directed. R&C-1339.45 , Add -28.5
All as per item No 1 above, but getting out in soft/disintegrated rock. R&C-490.25 Cum, Add -Nil
Excavating over areas n. exc 1.5m deep and getting out as in soft/loose of soil all as specified and as directed. R&C-24039.00, Add -Nil
Excavating earth from the backside of existing traverse wall, any height, in any type of soil and getting out before demolition of traverse wall complete all as specified and directed R&C-Nil, Add -454.25
All as per item No 3 above but getting out in hard/ dense soil. R&C-619.04, Add -528+4691.06+11971.00=171190.06
All as per item No 3 above but exc 1.5m and n.exc 3m deep and getting out in hard/ dense soil. R&C-3559.20, Add -Nil
All as per item No 3 above but getting out in soft/disintegrated rock. R&C-87.69 Add - 432+2010.69+9028.62=11,471.31
All as per item No 6 above but exceeding 1.5m and n.exc 3m deep and getting out in soft/disintegrated rock. R&C-415.00, Add - 512
Rremoving excavated soil from existing Traverse wall and depositing the excavated material at a distance n exc 250m, spreading and levelling at new traverse wall at a level n exc 3.00m above the starting point all as specified and as directed. R&C-13936.00 Add - 454.25
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed (for soil). R&C-2342.74 Add - 138+4382.15=4520.15
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed (for soft/disintegrated rock). R&C-145.00, Add - Nil
Removing excavated material (soil) n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and as directed. R&C-283.75 Add - 28.51
Removing excavated material (soil) to distance exc 250m and n exc. 500 m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and as directed. R&C-11189.86, Add -390
Removing excavated material (rock) exc 250m but n exc 500m and depositing where directed. R&C-Nil, Add -944.00
Removing excavated material (soil) to a distance exceeding 1.50Km but not exceeding 5Km and depositng where directed at a level not exceeding 1.5m above the starting point all as specified and as directed. R&C-17136.72, Add -4691.06+5970.57=10661.63
Removing excavated material (rock) to a distance exc 1.5 Km but n exc 5Km and depositng where directed at a level not exceeding 1.5m above the starting point all as specified and as directed. R&C-237.74, Add -2010.69+9258.15=11268.84
Forming embankments including raising (or lowering) earth, spreading in layers n exc 30cm thick, watering/ramming/rolling and finishing to required size, shape, exc 3.00 and n exc 4.50m high from base etc all as specified and directed. R&C-5940.00, Add - Nil
All as per item No 15 above but height exc 4.5 m and n exc 6.0 m high from base R&C-4860.00, Add - Nil
All as per item No 15 above but height exc 6.0 m and n exc 7.5 m high from base R&C-3780.00, Add - Nil
All as per item No 15 above but height exc 7.5 m and n exc 9.0 m high from base R&C-2700.00, Add - Nil
All as per item No 15 above but height exc 9.0 m and n exc 10.5 m high from base R&C-1620.00, Add - Nil
Demolition of cement concrete (Reinforced Traverse wall) of any description and in any position not otherwise specially provided all as specified and as directed. R&C-1819.23, Add - Nil
Removing demolished material (concrete slab) to a distance exceeding 5 Km but n.exe 10 km and depositing where directed (for traverse wall and Taxi/Floor of Blast pen). Notes : - Measurement shall be carried out for net volume of RCC/PCC demilished under respective item of this BOQ. R&C-5678.21, Add - Nil
Separating, scraping and cleaning of reinforecement of steel all as directed. R&C-1297.60, Add - Nil
Dismantling mild steel work of any description (angle bracket /post etc) all as specified and as directed. R&C-27.41, Add - Nil
(B) DEMOLITION OF TAXI/FLOOR OF BLAST PEN
Demolition of cement concrete (unreinforced) in any position and any thickness not otherwise provided for ground floors, pavings, (below or above ground level) all as directed. R&C-3858.98, Add - Nil
(C) TRAVERSE WALL
M&L for cement concrete (1:4:8) type D2 using 40mm graded aggregate as in foundation, filling and mass concrete etc all as specified and as directed (for traverse wall, CCD work, Hume pipe culvert, Area drainage, Toe wall and Box culvert). R&C-552.33, Add -64.80
M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to better for flat rough finish surface all as specified and as directed (for traverse wall, CCD work & Box culvert). R&C-4480.04, Add -1726.05
M&L for form work to faces of walls, abutment, retaining walls and similar work, vertical or to better for flat rough finish surface all as specified and as directed (for traverse wall & Box culvert). R&C-11672.00, Add -572.80+4761.52=5334.32
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, exceeding 200mm thick (Horizontal of sloping) or to batter for flat rough finish surface. R&C-Nil, Add -256.32
M & L for mild steel CRS TMT bars, Fe-500 Gde, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS (annealed )wire not less than 0.9 mm dia or secuting with clips all as specified and as directed (for traverse wall, CCD Works, Toe wall and Box culvert) Note :- Main reinfrocement and stirrups shall be measured under this item R&C-502564.76, Add -46277.92+7313.28+44987.04=98578.24
M&L for RCC M-30 (Design Mix) (using 20mm graded aggregate) as in foundations, including raft, footings, foundation, beams, plinth beams, bases for columns etc and mass concrete all as specified and as directed (for traverse wall, toe wall, CCD works and Box culvert). R&C-4639.72, Add -156.80
M&L for RCC M-30 (Design Mix) (using 20mm graded stone aggregates) as in retaining walls, basements wall etc all as specified and as directed (for traverse wall and Box culvert). R&C-3831.80, Add -51.20
M&L for RCC M-30 (Design Mix) (using 20mm graded stone aggregates) as in slabs supported on walls, beams and columns and similar work etc all as specifed and as directed (For Box culvert). R&C-67.20, Add -98.40
M&L for RCC M-30 (Design Mix) (using 20mm graded stone aggregates) as in columns, pillars, piers, posts and struts etc all as specifed and as directed (For CCD works). R&C-69.92 Add -159.88
M&L for MS framed work as in weep hole covers made of flat iron frame with welded wire mesh etc complete with gussets conforming to Fe-410 - W (Gde E-250, quality B) etc all as specified and as directed. R&C-520.00 Add - Nil
S&F rolled mild steel Joist, channel, angle or tee sections, fixed independently, without connecting plates, etc (cut to oridnary lengths) indicated Gde Fe410 W (Gde E-250) qaulity A R&C-Nil, Add -12947.04
S&F PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints laid in floor or wall (1500 mm centre to centre for weep holes) etc complete all as specified and as directed (for traverse wall and Toe wall). R&C-1017.00, Add - Nil
S&F Grating round 140 mm size of PTMT. (Minimum weight 50gms) all as specified and as directed. R&C-1736.00, Add - Nil
M & L for filling loose coarse sand at back for invert filter all as specified and as directed. R&C-39.00, Add - Nil
M & L for filling loose aggregate of size 20 mm graded at back for invert filter all as specified and as directed. R&C-58.00, Add - Nil
M & L for filling loose aggregate of size 60 mm graded at back for invert filter all as specified and as directed. R&C-181.00, Add - Nil
M & L for mild steel CRS TMT bars, Fe-500 Gde 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc all as specified and as directed. (For CCD work) Note :- Main reinfrocement and stirrups shall be measured under this item R&C-6751.60, Add -172938.08
M&L for rendering 10mm thick on concrete surfaces in CM (1:4) finished even and smooth without using extra cement all as specified and as directed. R&C-4539.00, Add - Nil
M&L for Use and waste of form work to the sides of pillers, posts and columns, square, rectangular or polyguard, in rough finished surfaces of concrete etc all as specified and as directed (for Traverse wall, CCD work & Toe wall). R&C-2604.63, Add -1421.56
M&L for preparation of plastered surfaces of walls including pilasters/cornices etc and applying two coats of Acrylic emulsion (exterior weather coat) paint of any tint as approved over one coat of primer applied as per manufacturer's instruction complete all as specifed and as directed. R&C-4539.00, Add - Nil
(D) ROAD AND CULVERT
M & L for approved GSB (Granular Sub Base) type-II filling 150mm thick, new constructions of rigid pavement in two layers (75mm each) with coarse aggregate of grading II including spreading, watering rolled with 8 to 10 Tonne power Roller and compacting to required gradient and camber all as specified and directed. R&C-75.00, Add - Nil
M&L for approved GSB (Granular Sub Base) type-II filling 200mm thick new constructions of rigid pavement in single layer coarse aggregate of grading II including spreading, watering rolled, with 8 to 10 Tonne power Roller and compacting to required gradient and camber all as specified and directed. R&C-Nil, Add - 4468.00
M & L for 150mm thick (compacted thickness) Wet Mix Macadam in two layers of 75 mm each including, spread, rolled and consolidated to required gradient, camber and shape complete all as specified and directed (for Road & Taxi/Floor of Blast Pen). Note : WMM to be laid with mechanicl pave of appropriate width requird at site as directed by GE/Engr-in-charge. R&C-3354.15, Add - Nil
M&L for 150mm thick DLC, corresponding to strength equivalent to M-15 grade as in sub base all as specified and directed (for Road & Taxi/Floor of Blast Pen). R&C-2807.62, Add - Nil
M&L for applying evently tack coat of VG-10 @ 2.5 kg per 10 sq metre over DLC surface complete all as specified and directed. R&C-Nil, Add -2234.10
M&L for sand cushioning 10mm or 25 mm thick over WMM or DLC surface spreading and well ramming as in road/floor etc all as specified & as directed (for Road & Taxi/floor of Blast pen). R&C-5.00, Add - Nil
M & L for polythene film of 400 micron conforming to IS-2508, spread and laid below PQC including sealing all joints etc complete all as specified and directed (for Road & Taxi/floor of Blast pen). R&C-22361.00, Add - Nil
M&L for cement concrete work in pavements/hard standing of fluxtural strength 40 Kg/sqcm in field using 400 Kg of cement/Cum, thickness of concrete 25 cm thick or less including steel shuttering to concrete etc eomplete all as specified and as directed. R&C-100.00, Add - Nil
Note. (i) Constrction joints, dummy (contraction joints) and expansion joints shall be measured and paid separately under respective items. (ii) Deduction shall be made in computing concrete quantity for expansion joints. (iii) No price adjustment shall be applicable if excess quantity of cement content is used/approved in the execution of work under this item. However minus price adjustment shall be made for less quantity of cement used in the work based on rate Rs. 6/- per Kilogram.
Finishing surfaces of concrete road, pavement by floater, plate vibrator, niddle vibrator and marking with hand roller etc when the concrete is grean all as specified and as directed (for Road & Taxi/floor of Blast pen). R&C-2236.00, Add - Nil
M&L for forming construction joint 30mm deep x 10 mm wide filled with sealing compound grade 'B' all as specifed and as directed. R&C-12.00, Add - Nil
M&L for forming 20 mm thick expansion joints and filled with pre-formed bituminrus filler and top 30mm primed and sealed with sealing compound grade 'B' all as specified and as directed. R&C-2.00, Add - Nil
M&L for forming (Dummy) contraction joints 65mm deep x 10 mm wide, filled with sealing compound grade 'B' all as specified and directed. R&C-30.00, Add - Nil
M&L for cement concrete (1:3:6) type C2 (using 40 mm graded stone aggregate) as in concrete bed to 600mm dia drain pipes including packing under and completely surrounding pipes with concrete after they are laid & tested all as specified and directed. R&C-12.00, Add - Nil
M&L for 600mm dia Reinforced concrete pipes class NP-2, laid & jointed complete with collars all as specified and directed. R&C-12.00, Add - Nil
M & L for precast cement concrete block masonary (1:5:8) mix, solid blocks, exc 10 cm in width and setting in cement mortar (1:6) all as specified and as directed. R&C-79.00, Add -82.96
M&L for rendering 10mm thick in CM (1:4) on fair faces of brick work or concrete surfaces including surfaces finished even and smooth without using extra cement all as specified and directed. R&C-11.00, Add - Nil
M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping including necessary form work, including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and as directed (for Road and Area drainage). R&C-4.10, Add - Nil
M&L for preparation of new surfaces of plaster and applying 3 coats of white wash on (culvert) walls all as specified and directed. R&C-11.00, Add - Nil
(E) TAXI/FLOOR OF BLAST PEN
M&L for rolling and consolidation of formation surface with suitable compacting plant such as vibratory roller etc, under optimum moisture content to achive at least 98% of maximum dry density (Modified PROCTOR density) and to achive K valve of 3.15 all as specified and as directed. R&C-21861.00, Add - Nil
M&L for 320mm thick PQC design mix for pavement/hard standing of flexural strength 45Kg/Sqcm and minimum 400 Kg of cement per Cum, with non circular Synthetic Fiber @ 0.25% by weight of cement including necessary steel form work all as specified and directed. R&C-6121.08, Add - Nil
Supply only non circular synthetic fibers with circumcircle diameter 30-35 microns, design for melting point of 240-260 degree celcius and having specific gravity 1.34 to 1.40 etc Make : Recron 3 S or equivalent all as specified and as directed. R&C-6121.08, Add - Nil
M & L for mild steel round bar for moring ring as per the requirement of user and as directed by Engr-in-Charge. R&C-64.00, Add - Nil
M&L for forming 320mm depth and 25mm wide expansion joint filled with Compressive filler board HD-100, provision of closed cell polyurethane back up rod 30 mm dia and sealed with pitch free polyurethane grey sealant (minimum depth of sealant above back up rod shall be 12mm) confirming to BS-5212 (type FB) priming the surface as recommended by manufacturers instructions and applying masking tape on edge of joint to prevent accidental spillage of sealant on top of the surface to give a neat finish to the sealant and removing the masking tape after the sealant is applied, the sealant should have MAF (+) / (-) 30 and manufacturers warranty of 10 years as used in international Air port in India etc complete all as specified and as directed. R&C-46.00, Add - Nil
M&L for forming construction joint 8 mm wide and 25mm deep with diamond cutter and provision of closed cell polyurethane back up rod 10mm dia and sealed with pitch free polyurethane sealant (minimum depth of sealent above back up rod shall be 12 mm) confirming to BS-5212 (type FB) priming the surface as recommended by manufacturers instructions and applying masking tape on edge of joint to prevent accidental spillage of sealant on top of the surface to give a neat finish to the sealant and removing the masking tape after the sealant is applied, the sealant should have MAF (+) / (-) 30 and manufacturers warranty of 10 years as used in international Air Port in India etc. complete all as specified and as directed. R&C-86.76, Add - 393
M&L for forming construction/Dummy joint 8mm wide and 100mm deep with diamond cutter and provision of closed cell polyurethane back up rod 10mm dia and sealed with pitch free polyurethane sealant (minimum depth of swalent above back up rod shall be 12 mm) confirming to BS-5212 (type FB) priming the surface as recommended by manufacturers instruction and applying masking tape on edge of joint to prevent accidental spillage of sealant on top of the surface to give a neat finish to the sealant and removing the masking tape after the sealant is applied, the sealant should have MAF (+) / (-) 30 and manufacturers warranty of 10 years as used in international airport in India etc complete all as specified and as directed. R&C-1311.80 Add - Nil
M&L for painting lines, dashes, arrows, letters etc on roads, pavements and the like exc 10 cm wide with road marking paint, white or golden yellow all as specified and as directed. R&C-281.10, Add - 96
(F) AREA DRAINAGE
M&L extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds mitred/stopped ends etc complete all as specified and as directed (Inner girth only measured). R&C-250.00, Add - Nil
M&L for cement concrete (1:3:6) type C-1 (using 40mm graded crushed stone aggregate) as in surface channels and drains all as specified and as directed. R&C-5.00, Add - Nil
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces, finished surfaces fair and even without using extra cement all as specified and as directed. R&C-580.00, Add - Nil
M & L for 300mm bore reinforced concrete pipes, class NP 2, laid and jointed complete with collars, all as specified and as directed. R&C-344.00, Add - Nil
M&L for concrete bed to 300mm bore of drain pipe including packing under and completely surronding pipes with concrete after they are liad and tested in cement concrete (1:3:6) type C2 (using 40mm graded aggregate) complete all as specificed and as directed. R&C-344.00, Add - Nil
E/M WORKS (A) INTERNAL ELECTRIFICATION
M & L for point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including ERW mild steel conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm PVC insulated but unsheathed multi stranded copper conductor FRLS cable as earth continuity wire including modular metal flush box of suitable size as required on site all as specified and as directed:-
(a) One 5 pin 5 or 6 Amps socket outlet on independent board. R&C-16.00, Add - Nil
S & F socket outlet multipurpose, 6 pin, 6 Amps, 250 volts (ISI marked) flush type controlled by one piano type switch as specified & as directed R&C-16.00, Add - Nil
S & F modular switch 1 way, 6 Amps, 1 module all as specified and as directed R&C-16.00, Add - Nil
S & F modular cover plate with frame, 3 module all as specified and as directed R&C-24.00, Add - Nil
S & F modular metal flush box 3 module all as specified and as directed R&C-24.00, Add - Nil
M & L point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable, drawn through and including PVC concealed conduit heavy duty grade ISI marked 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part-I, ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board as specified including modular metal flush box of suitable size as requirement on site all as specified and as directed R&C-8.00, Add - Nil
Supply and fix modular socket, 6/16 Amps, 2/3 pin combined 2 module all as specified and as directed R&C-8.00, Add - Nil
Supply and fix modular switch 1 way, 16 Amps, 1 module all as specified and as directed R&C-8.00, Add - Nil
Supply and fix triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 20 Amps, 415V, 10KA all as specified and as directed R&C-8.00, Add - Nil
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 V, 10KA etc complete all as specified and as directed. R&C-8.00, Add - Nil
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps, 240 V, 10KA etc complete all as specified and as directed. R&C-Nil, Add - 4.00
M&F for Earthing complete with galvanised steel plate electrode of size 600x600x6.3mm thick buried directly in ground with earth pit not less than 2.25 metre deep below ground level with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4mm dia by means of nuts, bolts, check nuts, washeres of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC(1:1:5:3) type A-1 cover slab of size 42 x 42 x 10 cm thick reinforced with 8 mm dia TMT CRS bars @ 15cm CC both ways with 10mm dia mild steel round bar of 30cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all etc as specified and as directed (for Internal Electrifications & External water supply) R&C-24.00, Add - Nil
S & F MCB, 3 Pole, 415V, fixed type, 40 Amps with breaking capacity 16KA all as specified and as directed. R&C-12.00, Add - Nil
S & F MCB, 4 pole, 415 volts, fixed type 63 amps with breaking capacity 16 KA all as specified and as directed. R&C-8.00, Add - 4.00
M&L for sub main wiring with two runs of 2.5 Sqmm single core PVC insulated but unsheathed multstranded copper conductor FRLS 1100 Volts grade cable, drawn through and including ERW mild steel conduit on surface of wall/ceiling ISI marked 20 mm dia (external) with wall thickness not less than 1.8 mm with conduit accessories and one run of 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor complete all as specified and as directed. R&C-240.00 Add - Nil
M & L for sub main wiring with two runs of 4 Sqmm single core PVC insulated but unsheathed multstranded copper conductor FRLS 1100 Volts grade cable, drawn through and including ERW mild steel conduit on surface of wall/ceiling ISI marked 20 mm dia (external) with wall thickness not less than 1.8 mm with conduit accessories and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor complete all as specified and as directed. R&C-120.00, Add - Nil
M&L for submain wiring with 4 runs of 6 Sqmm single core PVC insulated but unsheathed multstranded copper conductor FRLS 1100 Volts grade cable, drawn through and including ERW mild steel conduit ISI marked 20 mm dia (external with wall thickness not less than 1.8 mm with conduit accessories on surface of wall/ceiling and 2 run of 4.00 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor complete all as specified and as directed. Note : for item No 86 to 88: All runs of cable and 1 run of conduit shall be measured and paid as one metre length of unit. R&C-120, Add - 120
Supply & fix distribution board (DB), double door type, made out of sheet metal enclouse (CRCA sheet) dust and vermin proof DB, TPN, 415 Volts, 04 way with neutral bar and copper connector on wall/in meter board and connecting etc complete all as specified and as directed. R&C-8.00, Add - Nil
Supply & fix distribution board (DB), double door type, made out of sheet metal enclouse (CRCA Sheet) dust and vermin proof DB, SPN-240 Volts, 08 way with neutral bar and copper connector on wall/in meter baord and connecting etc complete all as specified and as directed.R&C-Nil, Add - 4.00
S & F MCB, SP, 240 volts, 6 to 32 Amps, Breaking capacity 10 KA complete all as specified and as directed. R&C-48.00, Add - Nil
S & F MCCB, TPN, 415 volts, 63 Amps 'C' series, 10KA etc all as specified and as directed. R&C-1.00, Add - 4.00
S & F wall mounted air circulator fans 230 volts single phase, oscilating type, 750 mm sweep, aerodynamically designed blades for higher air delivery and minium noise level, 90 degree oscilation with latest technology gear box complete all as specified and directed. R&C-8.00, Add - Nil
S & F LED Flood Light fitting 240 to 250 watt, High Efficiency IP65 protection, consisting of high/low voltage cut off, maintenance free isolated Electronic driver circuits. Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting including taking down old light fitting of any description complete all as directed. Make : Crompton cat part No LSFO-250-CDL/60/Philips cat part No BRP410LED242CWHE-NB-FG-S3XT/Havells cat part No LHEPDFU7P46J240 or equivalant Cat No of make as specified in Appx 'B to partical specifications. R&C-24.00, Add - Nil
S & F LED Flood Light fitting 90 to 107 watt, High Efficiency IP65 protection, consisting of high/low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting including taking down old light fitting of any description complete all as directed. Make : Crompton cat part No LSFO-90-CDL/Philips cat part No BRP410LED107CWHE-NB-FG-S3XT/Havells cat part No LHEUACN7PN6K100 equivalant Cat No of make as specified in Appx 'B to partical specifications. R&C-36.00, Add - Nil
(B) EXTERNAL ELECTRIFICATION
Supply, laying & testing XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty), 1100V grade with stranded aluminium conductor etc complete all as specified and as directed for the following cross sectional area :-
(a) 50 Sqmm, 3.5 core R&C-110.00, Add - Nil
(b) 35 Sqmm, 3.5 core R&C-1135.00, Add - Nil
(c) 25 Sqmm, 4 core R&C145.00, Add - Nil
(d) 10 Sqmm, 2 core R&C-750.00, Add - Nil
Note : Cable cover, sand cushioning and cable protection pipe will be measured & paid seperately under respective items of this BOQ.
M&L for dry river sand as in sand cushioining to under ground PVC cable including punning down of sand in layer complete all as specified and as directed. Note :- Punned thicknees will be measured for payment purpose. R&C-153.09.00, Add - Nil
Supply & lay ISI marked & conforming to IS-5820-1970 unreinforced precast concrete cable cover Class LV type-1, flat, size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed. R&C-12193.00, Add - Nil
M&L for 50 mm dia galvanised steel tubing, light grade with all fittings/fixtures laid in trenches or fixed on wall for protection of cable/earth lead when crossing road all as specified and as directed (For External electrification & Lightning protection). R&C-71.00, Add - Nil
Supply and lay GI tubing 40 mm dia bore light grade laid in trenches floor/fixing on pole/wall/roof for cable protection/fixed on roof for fixing of sheet with necessary fittings etc & taking down old rubing complete all as specified and as directed. R&C-40.00, Add - Nil
M&L for Earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6.3mm as earthing lead burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead strip 32x6mm and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/ earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- Items includes the cost of 7.5 metre GI pipe for protection and GI earth lead strip. Any additional in length shall be measured & paid seperately under respective items of this BOQ. R&C-18.00, Add - Nil
M&L for boring hole under roads/pavement/hardstanding without disturbing the top surface by trench less technology using ultra sound technique and necessary machine in and including HDPE pipe of 90 mm dia suitable for 0.4 mpa working pressure for passing through the cables etc complete all as specified and as directed. Note : Necessary infrastructure reqd for boring shall be arranged by the Contractor at his own cost). R&C-50.00, Add - Nil
Supply, installation, commissioning and testing of LT Feeder pillar factory made (CPRI approved), outdoor cubical compartmental type, single door, both side openable with hinged doors & locking arrangement, outgoing cable chamber with same rated aluminium strip from cable chamber to MCCB output, made out of 3.15 mm thick CRCA steel sheet supported and fixed on structural frame of angle iron of size 60x60x6mm angle iron frame including painting to all internal & external exposed steel surfaces with powder coating paint (5 stage process) duly fixed in ground in PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, suitable for 3 phase 4 wire system 500 volts grade with necessary wiring with PVC sheathed stranded copper conductor of appropriate length & size with and including fixing lugs, bolts, screws etc complete after taking down old unserviceable panel board of any size incl mounting and comprising of the following accessories :- R&C-1.00, Add - Nil
(a) Aluminium bus bar of rated capacity 300 Amps covered with PVC insulated sleeves, including insulator, nuts, bolts etc incl connection complete - 01 Set INCOMING (b) MCCB, 100 Amps, 415V, 4 pole, 50Hz, breaking capacity 25 KA with adjustable and thermal magnetic setting - 01 No. OUTGOING (c) MCCB 63, Amps, 415V, 4 pole, 50Hz, breaking capacity 16 KA with fixed thermal and magnetic setting - 04 Nos (d) LED type indicator lamp (Yellow, Blue, Red) - 01 Set (Set of three) (e) Voltmeter digital type - 01 No (f) Ammeter digital type with CT's - 01 No
(C) LIGHTENING PROTECTION
S&F Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc for roof/down conductor above ground including jointing with rivets/ brazing etc all as specified and as directed R&C-640.00, Add - Nil
Supply and fix air termination, single pointed, aluminium rod 12mm dia with 300mm long with all fitting arrangement etc complete all as specified and as directed. R&C-36.00, Add - Nil
Supply and fix earth continuity conductor or main earthing lead of size 32x6 mm galvanised iron strip fixed to wall on batter or recess or chases or buried in ground 500 mm below ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for earthing etc. as required all as specified and as directed. R&C-80.00, Add - Nil
Supply and fix test point terminal block made of gun metal or phosphorus bronze size 75 x75x 25mm, drilled and screwed including 3 Nos, 8mm dia, 25mm long hexagonal head screw complete all as specificed and as directed. R&C-16.00, Add - Nil
Supply and fix porcelain made insulator suitable for copper strips including fixing with suitable size of screw and wooden gutties all as specified and as directed. R&C-720.00, Add - Nil
(D) EXTERNAL WATER SUPPLY
Supply and installed Non clog pump set dry motor submersible pump type of discharge 1050 LPM at 10 m head alongwith lifting chain 3 m, lifting chain ring, auto rail coupling, non return ball valve, pedestal coupling, duct foot bend, guide rail pipe 3 m, guide rail holder, submersible cable 20m, including DOL starter and control panel etc complete all as specified and directed. Note : Necessary foundation work including PCC & MS work for fixing of non clog pump set as recommended by Original Equipment Manufacturer for complete functioning of NC pump set is deemed included in rates quoted for the item. R&C-8.00, Add - Nil
Supply and fix reflex valve (non return) valve of size 80 mm bore ISI marked complete all as specified and directed. R&C-8.00, Add - Nil
Supply lay & fix and testing galvanised steel water tubing, ISI marked, medium grade laid in trenches with and including all fittings/fixtures ISI marked etc. complete all as specified and as directed of following sizes:-
(a) 100mm bore of tube R&C-980.00, Add - Nil
(b) 80mm bore of tube R&C-400.00, Add - Nil
M&L for boring hole under roads/pavement/hardstanding without disturbing the top surface by trench less technology using ultra sound technique and necessary machine in and including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for passing through the cables etc complete all as specified and as directed. (Note : Necessary infrastructure reqd for boring shall be arranged by the Contractor at his own cost). R&C180.00, Add - Nil
CCD WORKS
M&L for compound griders and stanchions, lattice griders, aerial masts, staging for water tanks and the like including caps, bases, splices etc, built up from two or more beam of channel sections or angles with plates including all lattice bars, stiffeners, gusset plates etc. Conforming to Fe-410-W (Gde-E-250) quality 'A' all as specified and as directed. R&C-9170.48, Add - Nil
M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pleces, cleats etc. Conforming to Fe-410-W (Gde-E-250) quality 'A' all as specified and as directed. R&C-36206.24, Add - Nil
S&F plates (plain or chequered) channels, square cut or nicthed of Fe-410-W (Gde-E-250) quality-B (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment all as specified and as directed. R&C-4506.00, Add - 180.88
S&F High Tension SWR 8 mm dia lockable made ends all as directed by Engr-in-charge. (Make : Usha/Martin) R&C-6880.00, Add - Nil
S&F 8mm dia plain mild steel wire galavnised class-3, (IR netting to make arrangement for CCD the wire should be placed in manner as their good be know sagging to take the load) in wire netting including strainig and fixing steel posts or to staining bolts including securing with and provision of galansied iron typing wire, galvanised iron staples or steel pins etc as directed. R&C-Nil, Add - 543.28
S&F U-Clamp of (EN-9 Grade) for 8mm dia SWR Rope all as directed by Engr-in-charge R&C-160.00, Add - Nil
S&F High Tension steel screw bolts (machine made) diameter of neck 16 to 20 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 45 cm long all as directed by Engr-in-charge. R&C-120.00, Add - 140.32
S&F chain link MS galvanised mesh made of , 3mm nominal dia of wire and average width of aperture 250mm, overall size 5 m x 5 m having outer periphery of 4mm GI wire and rings @ 1 m interval and every corner (made of 4mm dia wire and 25mm ring dia) all as directed by Engr-in-charge. R&C-400.00, Add - Nil
Provision of MS spool to wind SWR over it with following facility/features all as directed by Engr-in-charge:- R&C-160.00, Add - Nil
(a) Spool dia 200mm with capacity to hold at least 18 mtr of 8 mm SWR. (b) Shaft to be of machine grade steel En-9 fixed with four ball bearing between two cast iron pedestal fixed to MS column & Plates etc. (MS work shall be paid separately) (c) Device to allow only one way winding while tightening and when unlocked (by pressing lever) free to move in both directions. (d) Shaft having design provisions to make it capable to be coupled with portable gear system with motor. (e) A lever/rod 1.5 m long 16mm dia for manual application of requisite torque and facility to lock it.
Provision of portable winches having following features all as directed by Engr-in-charge :- R&C-8.00, Add - Nil
(a) Stainless steel tubular structure made out of minimum 25mm dia of tube as holding trolley with four wheels (6" dia) with hard rubber tyre around it having provision for handles at min 900 mm height with ruberised grip (similar to Airport trolly). (b) Capacity of winch shall be 1000 Kg in tension through spool and torque of 150 kgm, gear system having ratio 1:4 x 4 (c) Facility to couple with spool shaft and locking with fixed frame for application of force/torque. (d) Panel to provide ON/OFF/STOP and speed control knob/switches at handle height (900mm) (e) This shall be electrically operated with flexible electrical wire of suitable size (min 45m long) with top.
S&F pully of 100 mm dia with two ball bearing and 18mm fixed dia and support system to attach with MS columns for changing the direction of SWR all as directed by Engr-in-charge. R&C-8.00, Add - Nil
M & L for two coats of synthetic enamel paint of approved shade over red oxide primer on newly prepared steel surface etc all as specified and as directed R&C-2000.00, Add - 650.04
Schedule of Credit of Rs. 19,87,965.00
M/s. Ambabhai K patel
Jeet Construction
vijay infraprojects pvt ltd
United Sales Corporation
Hariom Projects Pvt Ltd
MAGO CONSTRUCTION PVT. LTD.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid