Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | ₹9.5 L Quoted ₹9.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹10.2 L+₹39,408.76 (4.02%)Rejected-Finance | ₹10.2 L+₹39,408.76 (4.02%) | L2 | Rejected-Finance Due to high rate |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | THE MALLHIAN WALA COOPERATIVE LABOUR AND CONSTRUCTION SOCIETY LTD L1 | THE NEW NATIONAL CO-OP. L&C SOCIETY LIMITED L2 |
|---|---|---|---|---|---|
| 1.00 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below | 12 | each | 240 ₹2,880 | 234 ₹2,808 Lowest |
| 2.00 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Windows of area 3 sqm and below | 9 | each | 154 ₹1,386 | 149 ₹1,341 Lowest |
| 3.00 | Dismantling brick or flagged stone flooring without concrete base | 149.25 | sqm | 31 ₹4,626.75 | 29 ₹4,328.25 Lowest |
| 4.00 | Terracing consisting of tiles 22.86x11.43x 3.83cm laid over 25mm mud plaster 7.5cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 kg/sqm top of RCC slab inclusing grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing | 190.39 | sqm | 770 ₹1,46,600.3 Lowest | 841 ₹1,60,117.99 |
| 5.00 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. | 94.98 | m | 70 ₹6,648.6 | 68 ₹6,458.64 Lowest |
| 6.00 | Laying of dry brick ballast 40mm gauge for flooring | 18.19 | cum | 1,600 ₹29,104 | 1,534 ₹27,903.46 Lowest |
| 7.00 | Providing and laying vitrified floor tiles ofdifferent sizes in light colour shades made using Double Charge technology (thickness to be specified by themanufacturer) with water absorption`sless than 0.08% and confirming to IS:15622of approved make in all colours ans shade, laid on 20mm thick cement mortar 1:4,complete Size 800x800mm | 149.25 | sqm | 1,290 ₹1,92,532.5 Lowest | 1,395 ₹2,08,203.75 |
| 8.00 | Grouting the joints of flooring tiles having joints of 3mm width, using epoxy grout mix of 0.70kg of organic coated filler of desired shade(0.10 kg of hardner and 0.20 kg of resin per kg) i/c filling/grouting and finishing complete as per directionof Engineer-in-charge. Size 800x800mm | 149.25 | sqm | 150 ₹22,387.5 | 147 ₹21,939.75 Lowest |
| 9.00 | Preparation of plastered or concrete surfaces for painting (i/c sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish | 914.17 | sqm | 90 ₹82,275.3 Lowest | 92 ₹84,103.64 |
| 10.00 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface | 914.17 | sqm | 25 ₹22,854.25 | 22 ₹20,111.74 Lowest |
Tender Value
₹9.6 L
EMD Value
₹19,206
Closing Date
23 Aug 2024, 10:00 amClosed
Executive Engineer,
Executive Engineer, Bathinda Canal and Ground Water Division, Bathinda.
Repairing and Painting of Ziledar Office at Dadhahur.
2024_WR_125486_1
12/22A/2024-25
Open Tender
Civil Works
Item Rate
Raikot
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹19,206
Yes
Bathinda
23 Aug 2025
13 Aug 2024
23 Aug 2024
13 Aug 2024
23 Aug 2024
13 Aug 2024
19 Aug 2024
Amount
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Windows of area 3 sqm and below
Dismantling brick or flagged stone flooring without concrete base
Terracing consisting of tiles 22.86x11.43x 3.83cm laid over 25mm mud plaster 7.5cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 kg/sqm top of RCC slab inclusing grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Laying of dry brick ballast 40mm gauge for flooring
Providing and laying vitrified floor tiles ofdifferent sizes in light colour shades made using Double Charge technology (thickness to be specified by themanufacturer) with water absorption`sless than 0.08% and confirming to IS:15622of approved make in all colours ans shade, laid on 20mm thick cement mortar 1:4,complete Size 800x800mm
Grouting the joints of flooring tiles having joints of 3mm width, using epoxy grout mix of 0.70kg of organic coated filler of desired shade(0.10 kg of hardner and 0.20 kg of resin per kg) i/c filling/grouting and finishing complete as per directionof Engineer-in-charge. Size 800x800mm
Preparation of plastered or concrete surfaces for painting (i/c sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Finishing walls with cement based water paint such as snowcem, robbiacem etc. two or more coats to give an even shade
Distempering withAcrylic washable oil bound distamper (of approved manufacture) two or more coats over one priming coat to give an even shade
Applying pink primer or aluminium priming coat on wood work i/c preparation of surface knotting and stopping etc.
Painting two or more coats with synthetic enamel paints in all shades on old wood work or metalic or plastered or concrete surface to give an even shade including rubbing down old paint
Recessed PVC conduit pipe wiring system with modular switches Wiring in pvc insulated copper conductor single core FR cable ISI marked overall 1.5sq.mm, 1100 volts grade to be laid in heavy gauge pvc conduit pipe 20mm/25mm dia. ISI marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes(1.6mm thick with brass lugs) required for suitable no of modules for having step type electronic fan regulators (two modules) 100watts, bell push, 6amp 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc and covered with frame plate etc. PVC connector (for fan box Bell), steel Hooks, sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes(four way PVC 1.5" deep for walls and CI 3" deep for ceiling), bonding to earth with pvc insulated copper conductor single core FR cable ISI marked 1sq.mm., 1100 volts grade(for 6amp wall socket and plug control point) and other petty material etc. i/c the cost of above material, cutting and filling up of chases(with finishing the surfaces):- 15.1 Wiring fan point (w/o fan box)
Wiring light point
Wiring 6Amp. Wall socket point
Recessed Computer Supply Terminal Points (Used for HGW, PVC Conduit and HDPE pipe wiring system with modular accessories): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable no of modules for having 6Amp. 2/3 universal socket (shuttered), 16/20 Amp. Combined/ universal socket(shuttered), 3/10/16/20Amp. awitches and blanking plate etc., and covered with frame plate and other petty material etc. i/c the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring computer terminal point having 3 nos. 6Amp. 2/3 universal socket(shuttered), 1no. 16/20Amp. Universal socket (shuttered), 2nos. 16/20 Amp. Switches with indicator and 2 nos. blanking plate
Recessed TV, Telephone and networking socket outlet points (used for HGW, PVC conduit and HDPE pipe wiring system with modular accessories): Supply and erection of TV socket, Telephone socket and networking socket point inpowder coated/anodized concealed metal boxes recessed in wall reqd. for suitable no of modules for having TV sockets, Telephone socket RJ11 and networking socket RJ45 one module, covered with frame plate and petty material etc. i/c the cost of above material, cutting and filling up of chases (with finishing the surfaces);- Wiring Telephone socket point RJ11 (one module)
PVC insulated FR copper conductor cables: Supply and erection of PVC insulated FR single core unsheathed copper conductor cable Isi marked suitable upto 1100 volts grade confirmto IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the engineer-in-charge:- (a) Overall size 2.5sq mm (un-sheated)
PVC, HDPE pipes and PVC Flexible Pipes: Supply and erection of PVC conduit pipes ISI marked as per IS 9537:part III and HDPE pipes ISI marked as per IS4984:1995 for wiring purposes i/c bends, junction boxes, steel hooks, M.S. saddle clamps and other petty materials rtc., as per pwd general specifications:- (a) Medium Gauge PVC conduit Pipe 25mm dia. (flushed)
Miniature Circuit Breaker: Supply and erection of MCB`s for circuit protection against overload and short circuit current fault suitable for 240/415 volts 50cycles AC supply with breaking capacity of 10Ka Curve c and low watt losess as per IS/IEC 60898-1, energy limitation class-3, true contact indication, labelholder facility inthe existing MCB distribution board as per PWD general Specifications i/c connections with suitable sizes of thimbles/lugs:- (a) MCB single pole 6-32amp. (10ka, curve-c)
Sheet Metal Double Door Distribution Board For MCB`s/RCBO`s/RCCB`s: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door as per IS 8623-1&3,IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, eath bars, cement spill protector, color coded interconnecting wire set, cable ties, blanking plates and circuit indentifications label and of reqd. no of ways for mounting MCB`s/RCBO`s/RCCB`s in the distribution board asper PWD General specifications i/c connections with suitable sizes of timbles and bonding to existing eartg etc:- (a) SP&N Double Door Distribution Board 12 way each
Over head Distribution Aluminium Cables, ACSR conductors, clamps, jumpes and joint kits: Wiring overhead line in PVC insulated and PVC sheathed two single core aluminium conductor cable overall 1100 volts grade binding with G.I. wire 2mm dia.(14SWG) with brass/aluminium link clips complete inall respect as approved and desired by the engineer-in-charge ar site. PVC insulted & PVC sheated aluminium conductor cable overall size 10mm2 (1/1.40mm) Twin core.
Sail wood chowkats i/c iron hold fasts iron hinges corner straps clears, stops wooden knobs fixed in position. (a) Double Rebate (60mm x 150mm)
Red meranti Normal Super (18 to 19 kg per cft approx.) doors shutter windows shutter i/c hinges, screw and cords etc. complete fixed in position 35 mm thick
Wire gauge Red meranti wood super (18 to 19 kg per cft approx.) door shutter w/o springs housed in chowkats. 35mm thick
Providing and fixing 6" stainless steel handles ISI marked on door and windows frame complete in all respect as per the directions of engineer in charge
Providing and fixing 8" stainless steel tower bolt ISI marked on door and windows frame complete in all respect as per the directions of engineer in charge
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete
THE NEW NATIONAL CO-OP. L&C SOCIETY LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .