Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAdmitted-Finance | ₹3.5 L | L1 | Admitted-Finance |
| 2 | L2₹4.1 L+₹64,200 (18.4%)Admitted-Finance BANIKHET NAVEEN KUMAR BANIKHET CHAMBA HIMACHAL PRADESH 176303 | CHAMBA | HIMACHAL PRADESH | 176303 | ₹4.1 L+₹64,200 (18.4%) | L2 | Admitted-Finance |
| 3 | L3₹4.3 L+₹80,200 (22.9%)Admitted-Finance VILLAGE GAWALTH P O KUINAL TEHSIL KOTKHAI DISTT SHIMLA H P | KOTKHAI | SHIMLA | HIMACHAL PRADESH | ₹4.3 L+₹80,200 (22.9%) | L3 | Admitted-Finance |
| 4 | L4₹4.4 L+₹90,200 (25.8%)Admitted-Finance | ₹4.4 L+₹90,200 (25.8%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Naveen Kumar L2 | HARNAM SINGH L1 | Vinod L3 | Ashwani L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Construction of RCC in M-25 design mix underground storage tank of 20000 Ltrs. Capacity comprising of inlet, scour & over flow pipes as per details given below including bends of required degrees,valves of required size conforming to relevant codes, steel ladder 45 cms. wide of usual height as per site requirement , SFRC manhole cover ( medium duty) of 500mm dia and weight of frame and cover should not be less than 58 kg. ventilator at top dome with minimum opening of 90x90cms. water level indicator including floats and measuring gauge, lightening conductor with earthing arrangement etc.The RCC underground reservoir shall include randering/plastering of the uneven expose surface, two coats of snowcem paint and any other component required for the completion of job. The offers shall also include detail structural drawing/ design calcualtions to be approved by the competent authority based on the raft foundation by taking seismic forces in the design calculation expension joints as required at site. The offer shall also include the cost of providing and fixing of Gms / MS pipes, and valves/ fittings complete, expansion joints etc. connecting with rising main & distribution main with required length and any other components required for the completion of job upto the entire satisfaction of the Engineer-in-Charge. | 20,000 | Litres. | 20.7 ₹4,14,000 | 17.49 ₹3,49,800 Lowest | 21.5 ₹4,30,000 | 22 ₹4,40,000 |
| 1.01Dia of piping arrangement :- | |||||||
| 1.02Inlet pipe = 100mm dia G.I. pipe Medium class | |||||||
| 1.03Outlet pipe = 100mm dia G.I. pipe Medium class | |||||||
| 1.04Scour pipe = Not less than 100mm dia G.I. pipe. | |||||||
Tender Value
₹4.0 L
EMD Value
₹8,020
Closing Date
20 Jul 2026, 11:00 amClosed
Executive Engineer
Jal Shakti Division Kangra
C/O RCC Storage Under Ground Tank 20000 liters Capacity at Village Janyankar (UNDER PDNA
2026_HPIPH_138711_1
EE/JSDK/NIT/2026- 3469-3519 Dt.10-07-2026
Open Tender
Civil Works
Item Rate
90 days
Kangra
Please refer Tender documents.
6 documents required · 6 mandatory
₹350
₹8,020
22 Jul 2026
10 Jul 2026
20 Jul 2026
10 Jul 2026
20 Jul 2026
10 Jul 2026
10 Jul 2026 - 20 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of RCC in M-25 design mix underground storage tank of 20000 Ltrs. Capacity comprising of inlet, scour & over flow pipes as per details given below including bends of required degrees,valves of required size conforming to relevant codes, steel ladder 45 cms. wide of usual height as per site requirement , SFRC manhole cover ( medium duty) of 500mm dia and weight of frame and cover should not be less than 58 kg. ventilator at top dome with minimum opening of 90x90cms. water level indicator including floats and measuring gauge, lightening conductor with earthing arrangement etc.The RCC underground reservoir shall include randering/plastering of the uneven expose surface, two coats of snowcem paint and any other component required for the completion of job. The offers shall also include detail structural drawing/ design calcualtions to be approved by the competent authority based on the raft foundation by taking seismic forces in the design calculation expension joints as required at site. The offer shall also include the cost of providing and fixing of Gms / MS pipes, and valves/ fittings complete, expansion joints etc. connecting with rising main & distribution main with required length and any other components required for the completion of job upto the entire satisfaction of the Engineer-in-Charge. | 20,000 | Litres. | - | - |
| 1.01 | Dia of piping arrangement :- | - | - | - | - |
| 1.02 | Inlet pipe = 100mm dia G.I. pipe Medium class | - | - | - | - |
| 1.03 | Outlet pipe = 100mm dia G.I. pipe Medium class | - | - | - | - |
| 1.04 | Scour pipe = Not less than 100mm dia G.I. pipe. | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.49 MB
Form6and8.pdf
Tender Documents • 0.71 MB
Termsandcondition.pdf
Tender Documents • 0.21 MB
BOQ_205464.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .