Executive Engineer Ukai Division No.1, Ukai
Providing and Erecting to High mast Tower for Down Stream Area of Spillway Side at Keliya Dam
342847
E tender Notice No.18 of 2026-27
Open
Electrical - All
Works
Tapi
9 documents required · 9 mandatory
₹900
Executive Engineer Ukai Division No.1,Ukai
₹9,000
7 Sept 2026
7 Sept 2026
7 Sept 2026
21 Sept 2026
7 Sept 2026
Name of Work : Providing and Erecting to high mast Tower for Down Stream Area of Spillway Side at Keliya Dam
Qty Description Item Rate Per Amount
Supplying and erecting Flexible PVC insulated multi strand
1 multi core 1.1 kv grade ISI marked copper wires of following
size to be erected as directed.
(h) 2.50 Sq.mm 3 core round PVC sheathed
Rupees NinetySeven Paise
NinetySeven Only
Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate
optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,Power
2 Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)
(B) Flood Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over-voltage
Rupees Nine Thousand One Ea
20 (vii) 200 to 250 watts cat-III 9196.05 Hundred NinetySix Paise Five
Providing & erecting 415 V MCB Four Pole for Motor &
Inductive Load (C Curve) having 10KA breaking capacity
3 & confirms to IS :8828 in existing box having following
(b) 40 Amp. Cat.- III Ea
Rupees Seven Hundred
ThirtySix Paise TwentyNine Only
Providing and erecting XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
4 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables
(a) 4 core 16 Sq. mm Rupees One Hundred Mtr
350 184.83 EightyFour Paise EightyThree
Supplying & erecting in earthpit of minimum bore dia.
225mm size approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having Outer
pipe dia of 80 mm having 80-200 Micron galvanising,
Inner pipe dia of 40 mm having 200-250 Micron
galvanising, connection terminal dia of 14 mm with
constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for
following type of applications with chamber and heavy
duty cover (A)(approved make OEM has to submit test
certificate including value of earth resistance of installation
duly stamped and signed by agency and officer Incharge
has to ensure the value of earthing resistane mentioned in
test Certificate) & having back filling compound of (B)
Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm /
meter testing as per IEC 62561-2017, Voltage drop:- <
volt at no load & dry form, Sulphar content:- <2%(C) Back
fill Compound :- Earthing compound should be capable to
retain moisture for long time Necessary test report must
be submitted by Agency.
[A] For electrical installation up to 440 V
Rupees Five Thousand Eight
Length of Pipe - 1 Mtr
4 5842.85 Hundred FourtyTwo Paise Ea
Back filling compound - 1 Nos. of Bag of 15 Kgs.
EightyFive Only
Making trench in Hard Murrum / Tar Road of suitable width
of 90 cm or required depth for laying any size of cable or
Rupees SeventyFour Paise
6 341 locating the fault all over the run and back filling the same 74.74 Mtr
SeventyFour Only
and making the surface as normal ground.
(B) If additional machinery like hammer driller or JCB use
Rupees Three Hundred
FiftySeven Paise FiftyFour Only
Providing & laying approved make Double walled
corrugated pipes (DWC) of polyethylene(conforming to
IS 14930 II )with necessary connecting accessories of
8 same material at required depth in existing trench for
laying of cable. below ground / road surface for enclosing
Rupees SixtyTwo Paise
340 (A)50 mm outer dia 62.62 Mtr
Solder less crimping type Aluminium lugs conforming to
IS suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals
9 with brass/cadmium plated nut bolts in an approved
Rupees Fifteen Paise Fifteen
Supplying & erecting approved make time switch with
single pole airbreak contacts suitable for
V.15/16A.complete with self starting motor driven clock Rupees Two Thousand Three
10 2 ‘ON’ &’ OFF’ automatic arrangement at any predetermined 2354.31 Hundred FiftyFour Paise Ea
time during each 24 hours,With nickel cadmium ThirtyOne Only
rechargeable battery backup erected as directed.
Supplying, erecting, testing, commissioning approved
make M.S. Polygonal High Mast Pole having following
general Specification.
(a) Polygonal Section fabricated from M.S. Plate confirms
BSEN 10025 & Hot deep galvanized minimum 65/86
micron (as per IS 2629 /1985) Lantern carriage with ring
and rubber lines for erection of luminaries of suitable site.
(b) Maximum telescopic section not more than four
(c) Double drum gear pipe motorized winch with 6mm dia
S.S. Rod (For 16 mtr and above size)
11 . (d) Approved make L.E.D. aviation light = 1 No. Lightening
arrestor = 1 No. with necessary wiring of 2.5 sq.mm 5 core
ISI copper cable Unarmoured.
(e) Bottom most section suitable for mounting reversible
motor and switchgears having door not more than
1400mm x 300mm with waterproof gasket & hinges &
locking arrangement.
(f) Pole structure comprises suitable size of reversible
motor, cable and necessary switchgears with control
[4] High Mast 16 Mtr. TOP A/F 150 Mm, BOTTOM A/F
Mm, No. of Sec. No. - 2, Bottom Thickness - 4 mm, Top
Sec. - 3 mm, Size Base Plate - dia.630 mm x 20 mm thick, Rupees Two Lakh Twelve
2 Foundation Bolt Size M24 x 870 mm, Qty - 12 Nos., 212104.04 Thousand One Hundred Four Ea.
Suitable for mounting Fitting of Light - 10 Nos. Paise Four Only
Providing and erecting AC-3 duty 3 pole power contactor
with 2 NO & 2 NC aux contacts complete with 415V/220V
operating coil suitable for (L&T, BCH,T.C., Siemens, C&S
(B) for 40 A rating Rupees Four Thousand Seven Ea
4 4793.46 Hundred NinetyThree Paise
I/We am/are willing to carry out the work at …………………………………………………………………% above/below percent (shouldbe written in
figured and words) of the estimated rates mentioned above. Amount of my/our tender works out as under.
Estimated amount Estimated amount
Put to tender Rs______________ Put to tender Rs______________
Deduct : ___________ % Above RS__________ Deduct : ___________ % Below RS__________
*(Please strike out whitchever is not applicable).
Note 1 – All work shall be carried out as per public works department handbook and other specification of Division ot as directed.
Note 2 – All the columns is schedule should be filled in ink and the total of the entries in the last column should be struck by the contractor
under his signature.
Note 3 – Rates quoted include clearance of site (prior commencement of work and at its close ) in all respects and hold good for work under all
conditions, site, moisture,weather etc.
Note 4 – To be continued on additional sheets, if found necessary.
Note 5 - The rates quoted by the Contractor must be inclusive of all taxes prevailing on due date of bid submission except GST.
However, any subsequent changes in the tax structure by Government after due date of bid submission will be compensated (+/-) on
availability or submission of actual documentation. Contractor will have to intimate Engineer regarding changes occurred in the tax
structure after bid submission. If the contractor fails to provide such information and if any financial obligation may arise due to
change in tax structure, same will be recovered from the contractor. GST will be paid separately on the bills. Hence, it is the
responsibility of the contractor to pay the GST to the concerned Authority.
Deputy Executive Engineer Executive Engineer
Electrical Sub Division Ukai Division No.1
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD HM Tower DS Spillway Keliya.pdf
SCH B 2.pdf
2.0 Special condion Electric (5).pdf
Make List 2.pdf
5.0 Approved make list 2013 2014 Part 1.pdf
6.0 Approved make list 2013 2014 Part 2.pdf
E-Tender Notice No.18 of 2026-27.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .