Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | INTIMATE REFRIGERATION AND AIR CONDITIONS L1 |
|---|---|---|---|---|
| 1.00Air Conditining | ||||
| 1.00 | OD9663/2026-2027:All-Inclusive Comprehensive Maintenance Contract for Air Conditioning /Other Equipment with model no.JRUV160LTE5 -LG make 16 HP VRF, Packaged and ducted systems, along with all accessories, including 1 TR/1.5 TR/ 2TR/3TR Four-way Cassette/Hiwall type Indoor units. Service of the plant 12 times per year 1. The compressor shall be checked for its proper functioning and if any defect is found,the same will be repaired. 2. Safety controls such as pressure cut-outs will be tested for proper functioning, and in case of any malfunctioning, they will be either repaired or replaced accordingly. 3. Air filters shall be inspected and cleaned or replaced, if necessary 4. The cooling/Condensing coil should be inspected and cleaned, if necessary. 5. The blower motor shall be checked and any defects noticed shall be attended to. 6. The driver set of the blower section shall be inspected, belt tension adjusted, and belts changed, if necessary. 7. Any defects in the electrical items and control wiring shall be attended to. 8. Refrigerant gas shall be topped up in the systems as and when necessary. 9. Repairs to refrigerant piping due to system problems shall be attended to. | 4 | each | 99,801.6 ₹3,99,206.4 Lowest |
| 1.00 | OD9666/2026-2027:All inclusive Comprehensive maintenance contract of the following air conditioner units including replacement of defective accessories, refrigerant controls, pressure testing of the system, vacuuming, oil charges,gas charging,replacing defective single phase preventer,three pole contractor etc. as required and excluding the replacement of defective compressor, electrical Mains witches and Civil works.11 TR Air Cooled Inverter Duct able Split AC units service of the plant 12 times per year | 2 | each | 68,613.6 ₹1,37,227.2 Lowest |
Tender Value
₹5.4 L
EMD Value
₹13,411
Closing Date
7 Nov 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer
Assistant Executive Engineer,PWD Electrical sub division,Tvpm
GENERAL-Annual Maintenance contract of AC units in Stroke ICU cath lab at MCH Tvpm-Annual Maintenance contract of VRF and Inverter Type Ductable AC units installed in Stroke ICU ,stroke theatre and Cath Lab for one year-Electrical AC Work
2026_PWD_878486_2
ESDT/ET-132/2026-27
Open Tender
Electrical Works
Item Rate
365 days
PWD Electrical sub division Thiruvananthaouram
please refer tender documents
6 documents required · 6 mandatory
₹1,185
₹13,411
10 Nov 2026
31 Oct 2026
9 Nov 2026
31 Oct 2026
7 Nov 2026
31 Oct 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Air Conditining | |||||
| 1.001 | OD9663/2026-2027:All-Inclusive Comprehensive Maintenance Contract for Air Conditioning /Other Equipment with model no.JRUV160LTE5 -LG make 16 HP VRF, Packaged and ducted systems, along with all accessories, including 1 TR/1.5 TR/ 2TR/3TR Four-way Cassette/Hiwall type Indoor units. Service of the plant 12 times per year 1. The compressor shall be checked for its proper functioning and if any defect is found,the same will be repaired. 2. Safety controls such as pressure cut-outs will be tested for proper functioning, and in case of any malfunctioning, they will be either repaired or replaced accordingly. 3. Air filters shall be inspected and cleaned or replaced, if necessary 4. The cooling/Condensing coil should be inspected and cleaned, if necessary. 5. The blower motor shall be checked and any defects noticed shall be attended to. 6. The driver set of the blower section shall be inspected, belt tension adjusted, and belts changed, if necessary. 7. Any defects in the electrical items and control wiring shall be attended to. 8. Refrigerant gas shall be topped up in the systems as and when necessary. 9. Repairs to refrigerant piping due to system problems shall be attended to. | 4 | each | - | - |
| 1.002 | OD9666/2026-2027:All inclusive Comprehensive maintenance contract of the following air conditioner units including replacement of defective accessories, refrigerant controls, pressure testing of the system, vacuuming, oil charges,gas charging,replacing defective single phase preventer,three pole contractor etc. as required and excluding the replacement of defective compressor, electrical Mains witches and Civil works.11 TR Air Cooled Inverter Duct able Split AC units service of the plant 12 times per year | 2 | each | - | - |
stage.html
html • 0.02 MB
finance_1507192.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1507192.xls
BOQ • 0.30 MB
sbd.pdf
Tender Documents • 1.66 MB
mom.pdf
Tender Documents • 14.33 MB
scac.pdf
Tender Documents • 0.85 MB
nit.pdf
Tender Documents • 0.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .